submitted | available | document details (if available) | source link |
---|---|---|---|
September 25 2009 | September 25 2009 | Report template Ingenico Acrobat Distiller 8.1.0 (Windows) |
various | Manual | Users Manual | 1.13 MiB | September 25 2009 |
Productname:iCT220/iCT250 Range:COUNTERTOP e d i u G r e s U INGENICO192avenueCharlesdeGaulle92200NeuillysurSeineFRANCE Tl.33(0)146258200Fax33(0)147725695 www.ingenico.com Contents 1. Introduction __________________________________________________3 2. Unpacking____________________________________________________3 3. Recommendations ____________________________________________ 4 3.1. Security _____________________________________________________________4 3.2. Telephoneemergency,hangingup _______________________________________4 3.3. Securityofyourterminal _______________________________________________5 3.4. ECstandardcompliancemarking_________________________________________5 3.5. Networkcompatibilitydeclaration _______________________________________6 3.6. FCCcompliance _______________________________________________________6 3.7. MainCharacteristics ___________________________________________________7 4. Installationandconnection_____________________________________ 8 4.1. Positioningtheterminal ________________________________________________8 4.2. Connections__________________________________________________________8 4.3. InstallingtheiCT220/iCT250Cablefixing__________________________________8 4.3.1. Openingthecablecover_________________________________________________________ 8 4.3.2. Connectcables ________________________________________________________________ 9 4.3.3. Closecover __________________________________________________________________ 10 4.4. KitMagicBoxinstallation(optional) _____________________________________ 10 4.4.1. InstallationoftheMagicBox _____________________________________________________ 11 4.5. InstallingSAM(Secureaccessmodule) ___________________________________ 12 4.6. InstallingMicroSDCard(optional)_______________________________________ 13 4.7. InstallingSIMforGPRS(optional) _______________________________________ 13 5. Installingapaperroll __________________________________________ 14 6. Dailyuse ____________________________________________________ 15 6.1. Keypadfunctions ____________________________________________________ 15 6.2. Adjustingthecontrast ________________________________________________ 15 6.3. Cardinsertion _______________________________________________________ 16 6.3.1. Swipingacard________________________________________________________________ 16 6.3.2. Insertingachipcard ___________________________________________________________ 16 6.3.3. Insertingachipcardinsecondreader(Optional)____________________________________ 16 6.3.4. ReadingContactless(Optional) __________________________________________________ 16 7. Maintenance_________________________________________________ 17 7.1. Paperroll ___________________________________________________________ 17 7.2. Cleaningoftheterminal _______________________________________________ 18 7.3. Transportandstorage ________________________________________________ 18 7.4. Troubleshooting _____________________________________________________ 18 7.5. ___________________________________________________________ 19 Endoflife Productname:iCT220/iCT250 9000002509R1100002/935 2/20 Copyright2009Ingenico Allrightsreserved 1. Introduction ThankyouforchoosinganIngenicopaymentterminal. Werecommendyoutoreadcarefullythisuserguide:Itgivesyouthenecessaryinformation aboutsafetyprecautions,unpacking,installation,andmaintenanceofyourterminal. CAUTION Tobenefitfromtheguaranteerelatedproduct,andtorespectthesecurity,weaskyouto use only the power supply delivered in box with the product, entrusting maintenance operationsonlytoanauthorizedperson. Failuretocomplywiththeseinstructionswillvoidthemanufacturersresponsibility. 2. Unpacking ADVICE Carefully preserve the packaging of the iCT220/iCT250. It must be reused whenever the terminalisshipped. According to the model, the following items are included in the iCT220/iCT250 box
(includingoptionalaccessories):
TheiCT220/iCT250terminalequippedwithitspaperroll Themainpowersupplywithitscableconnection(accordingtothenationalneeds). Thecableconnectionforthetelephonenetwork Thisinstallationguide Userguide iCT220/iCT250 terminal Wallmounted powersupplyunit Cableconnectionforthe telephonenetwork CAUTION The power supply unit provided with your equipment is specially designed for Ingenico iCT220/iCT250terminals.Donotuseanyotherpowersupply. Desktoppowersupplyunit provided(mandatory)with iCTequippedwiththe followingoptions:
GPRSmodel Contactlessmodel Productname:iCT220/iCT250 9000002509R1100002/935 3/20 Copyright2009Ingenico Allrightsreserved 3. Recommendations 3.1. Security Poweron/Powerdown To power on or power down the iCT220/iCT250 connect or disconnect the power supply fromtheelectricoutlet. Lithiumbattery TheiCT220/iCT250isfittedwithalithiumbatterywhichisnotaccessibletotheuser.Onlya qualifiedtechnicianmaybeauthorizedtoopentheunitandchangethiscomponent. Electricalpowersupplynetwork Provideanelectricaloutlet:
locatedneartheequipmentandeasilyaccessible whichmeetsthestandardsandregulationsinthecountryofuse. Telephonenetwork Provideaphonejackcomplyingwithstandardsandregulationsinthecountryofuse. SAM/SIMorSDMemoryCardcompartmentcover Locatedundertheterminal,itmustbeinplaceduringnormaloperationoftheterminal. Cablecompartmentcover The cable compartment cover is located under the terminal, it must be in place during normaloperationoftheterminal. 3.2. Telephoneemergency,hangingup Youhaveanurgentcalltomake,wheniCT220/iCT250hangsontheline. Inordertogetadialtone Placethehandsetinthehanguppositionand:
or or presstheredkey(=cancel) disconnectthepowersupplyfromthemainsnetwork disconnecttheiCT220/iCT250telephoneconnectorfromthetelephonecallsocket, andplacethetelephoneconnectorintothetelephonewallsocket. Youwillhaveadialtonewithin6seconds. Productname:iCT220/iCT250 9000002509R1100002/935 4/20 Copyright2009Ingenico Allrightsreserved 3.3. Securityofyourterminal Uponreceiptofyourterminalyoushouldcheckforsignsoftamperingoftheequipment.It is strongly advised that these checks are performed regularly after receipt. You should check,forexample:thatthekeypadisfirmlyinplace;thatthereisnoevidenceofunusual wiresthathavebeenconnectedtoanyportsonyourterminalorassociatedequipment,the chipcardreader,oranyotherpartofyourterminal.Suchcheckswouldprovidewarningof any unauthorised modifications to your terminal, and other suspicious behaviour of individualsthathaveaccesstoyourterminal.Yourterminaldetectsanytamperedstate. In this state the terminal will repeatedly flash the message Alert Irruption! and further useoftheterminalwillnotbepossible.IfyouobservetheAlertIrruption!message,you shouldcontacttheterminalhelpdeskimmediately. Youarestronglyadvisedtoensurethatprivilegedaccesstoyourterminalisonlygrantedto staffthathavebeenindependentlyverifiedasbeingtrustworthy. CAUTION NEVERaskthecustomertodivulgetheirPINCode.Customersshouldbeadvisedtoensure thattheyarenotbeingoverlookedwhenenteringtheirPINCode. 3.4. ECstandardcompliancemarking ECstandardcompliancemarkingcertifiesthattheproductstipulatedbelow:iCT220/iCT250 complies with the basic requirements of European Directive 1999/5/CE, known as the R&TTE Directive concerning Radio Frequency equipment and telecommunications terminalswithrespectto:
Healthandsafetyprotectionoftheuserandallotherpersons EMCprotection conformstothefollowingharmonizedstandards:
IEC/EN 609501: Electrical safety of data processing equipment including electrical officeequipment.Issuedec2001 EN 55022: Data processing equipment Radioelectric disturbance characteristics Limitsandmeasurementmethods.Issue1998/A12000/A22003 EN 55024: Data processing equipment Immunity characteristics Limits and measurementmethods.Issue1998+A12001+A22003
/122001
/082000
/122000 Accordingto 73/23/EEC Accordingto 89/336/EEC Accordingto iCT220/250GPRS
(LowVoltageDirective) EN609501
(EMCDirective) EN3014897 EN301511
(R&TTEDirective) EMFAccordingto1999/519/ECRecommendation iCT250CLESS EN609501 EN3014893 EN3003302/062001 Accordingto1999/5/EC(R&TTEdirective) Accordingto 73/23/EEC Accordingto 89/336/EEC
(LowVoltageDirective)
(EMCDirective)
/122001
/082000 1999/5/EC complieswiththefollowingspecification:
ETSI ES 203021: Harmonized basic attachment requirements for Terminals for connectiontoanalogueinterfacesoftheTelephoneNetworks;
Productname:iCT220/iCT250 9000002509R1100002/935 5/20 Copyright2009Ingenico Allrightsreserved 3.5. Networkcompatibilitydeclaration Theproduct:iCT220/iCT250 areinconformitywiththefollowingharmonisedstandardsortechnicalrules:
ETSIES203021ETSITR103000 are designed to interwork with the following European analogue Public Switched Telephone Network (PSTN) networks : Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Liechtenstein, Luxembourg, The Netherlands, Norway,Portugal,Spain,Sweden,Switzerland,UnitedKingdom.
(Forothercountries,pleasecontactus) NOTE Compliancewithotherforeignstandardsisverifiedbyalocaltypeapprovalonrequest. 3.6. FCCcompliance FCC ID : XKB-ICT220availableonthefollowingsequipments:
ICT22001T1052 This equipment as been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonableprotectionagainstharmfulinterfaceinaresidentialinstallation.Thisequipment generates uses and can radiate radio frequency energy and, if not installed and used in accordancewithinstruction,maycauseharmfulinterferencetoradiocommunications. However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.If thisequipmentdoescauseharmfulinterferencetoradioortelevisionreceptionwhichcan bedeterminedbyturningtheequipmentoffandontheuserisencouragedtotrytocorrect interfacebyonemoreofthefollowingmeasures:
Reorientorrelocatethereceivingantenna. Connecttheequipmentintoaoutletoncircuitdifferentfromthattowhichthereceiver Increasetheseparationbetweentheequipmentandreceiver. isconnected. Consultthedealeroranexperienceradio/TVtechnicianforhelp. Part68ofFCCRules US : IEOMM01BICT220availableonthefollowingsequipments:
ICT22001T1052 ThisequipmentcomplieswithPart68oftheFCCrulesandtherequirementsadoptedby the ACTA. On the bottom of this equipment is a label that contains, among other information, a product identifier in the format US: AAAEQ##TXXXX. If requested, this numbermustbeprovidedtothetelephonecompany. ThisequipmentusesthefollowingUSOCjacks:(RJ11C). A plug and jack used to connect this equipment to the premises wiring and telephone networkmustcomplywiththeapplicableFCCPart68rulesandrequirementsadoptedby theACTA.Acomplianttelephonecordandmodularplugisprovidedwiththisproduct.Itis designed to be connected to a compatible modular jack that is also compliant. See installationinstructionsfordetails. TheRENisusedtodeterminethenumberofdevicesthatmaybeconnectedtoatelephone line.ExcessiveRENsonatelephonelinemayresultinthedevicesnotringinginresponseto Productname:iCT220/iCT250 9000002509R1100002/935 6/20 Copyright2009Ingenico Allrightsreserved anincomingcall.Inmostbutnotallareas,thesumofRENsshouldnotexceedfive(5.0).To becertainofthenumberofdevicesthatmaybeconnectedtoaline,asdeterminedbythe totalRENs,contactthelocaltelephonecompany. Ifthisequipmentcausesharmtothetelephonenetwork,thetelephonecompanywillnotify youinadvancethattemporarydiscontinuanceofservicemayberequired.Ifadvancenotice isnotpractical,thetelephonecompanywillnotifythecustomerassoonaspossible.Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of this equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modificationstomaintainuninterruptedservice. If trouble is experienced with this equipment, please contact INGENICO, or your local INGENICOdistributororservicecenterintheU.S.A.forrepairand/orwarrantinformation. Ifyourhomehasspeciallywiredalarmequipmentconnectedtothetelephoneline,ensure the installation of this equipment does not disable your alarm equipment. If you have questionsaboutwhatwilldisablealarmequipment,consultyourtelephonecompanyora qualifiedinstaller. CAUTION TheuseriscautionedthatanychangesormodificationnotapprovedbyINGENICOcould voidusersauthoritytooperatetheequipment. 3.7. MainCharacteristics Terminal Weight Size about325gto350gfulloption 185x83x63mm(lxwxh) approx115g(withoutmainscable) approx77x25x89mm(Lxwxh) ClassIIequipment 220230V50Hz/120V60Hz(accordingtocountry) 210mA/400mA Powersupplyunit(wallmounted) Weight Size Class Inputvoltage Maxconsumption Thepowersupplyunitisespeciallydesignedbythemanufacturerforitsterminalsandso mustbeused. Desktoppowersupplyunit Weight Size Class Inputvoltage Maxconsumption approx230g(withoutmainscable) approx98x50x30mm(Lxwxh) ClassIIequipment 100240VCA5060Hz 800mA Cablelength Powerblockcable approx1,8m Telephonecable approx3m Productname:iCT220/iCT250 9000002509R1100002/935 7/20 Copyright2009Ingenico Allrightsreserved 4. Installationandconnection 4.1. Positioningtheterminal Installtheterminalonaflatsurface,withaneasyaccesstoanelectricaloutletandtelephone line. Place the terminal away from any heat source and protected from dust, vibrations and electromagneticradiations(awayfromvideoterminals,PC,antishopliftingbarriers,...). Operatingconditions Ambienttemperature Maxrelativehumidity from+5Cto+45C 85%at+40C Storageconditions Storagetemperature Maxrelativehumidity 20C,+55C 85%at+55C 4.2. Connections Allconnectionsareontherearoftheterminalprotectedbyacover. Telephone
*accordingtothemodel PowerSupply SerialLinkRS232 USBSlave EthernetLink(Optional)*
USBHost SecondSerialLinkRS232
(Optional)*
4.3. InstallingtheiCT220/iCT250Cablefixing 4.3.1. Openingthecablecover Unclipthecoverbypushingsimultaneouslyontheclips1withyournailsfingeras shownonthefigureherebelow. Liftthecoverrearwardtoremoveit,asshownbyarrowsonthefigure. 1 Productname:iCT220/iCT250 9000002509R1100002/935 8/20 Copyright2009Ingenico Allrightsreserved 4.3.2. Connectcables Performthefollowingoperations:
Plugtelephoneline1,equippedifnecessarywithusercountryspecificconverter2,to thetelephonenetwork3.Connecttheotherendtotheterminaltelephoneconnection 4. Ifnecessary,connectthetelephone(Telephoneisnotrequiredfortheterminaltooperate) Plug power lead5intothe power socket6,connecttheotherendtotheterminal powerconnection7. 7 4 Installbetweentheribs:
Powerleadcable Telephonecable Ethernetcable(optional) Installintheleadthrough(optional):
USBHostcable USBSlavecable Rs232cable. 3 7 4 6 2 Forinstance, possible configurationfor France Plug:TNV3circuit:TelecommunicationNetworkVoltage,aspersafetystandardEN60950. 5 1 Productname:iCT220/iCT250 9000002509R1100002/935 9/20 Copyright2009Ingenico Allrightsreserved 4.3.3. Closecover To close the cover, start by inserting the clips 1 of the cover in their housing respectivelyfirst,asshownonthefigureherebelow,andclosethecover. 4.4. KitMagicBoxinstallation(optional) 1 WARNING Connectingistobemadewhentheterminalisoff. ThekitMagicBoxofyouriCT220/iCT250isshippedwithaspecialcover. Followtheinstallationinstructionsshownbelow:
Plug:
1 Powerlead 2 Telephoneline 3 Ethernetcable 4 SeriallinkRS232cable 1 2 caps 4 3 Install caps in the leadthrough (as indicated on thefigure). Close the compartment with the special cover providedinthekit,liketheproceduredescribedat chapter4.3.3. Productname:iCT220/iCT250 9000002509R1100002/935 10/20 Copyright2009Ingenico Allrightsreserved 4.4.1. InstallationoftheMagicBox ADVICE ItisstronglyrecommendedtoattachtheMagiccabletoterminalsworkareainorder toreducestressontheterminalandconnection. 1 23 ExamplesofsecuringtheMagicCableareasillustrated:
1 Usingthesuppliedcabletietoattachtoatableleg(orsimilar) 2 Usingthesuppliedcabletieandselfadhesivesupport 3 Usingacountersunkscrew(notsupplied)toanappropriatesurface TheMagicCableshouldbereadilyaccessibleforsupportandterminalhelpdesk diagnosispurposes. Note:TheconnectionMagicBoxcanalsobeattachedusingaVELCROorothersystem. Productname:iCT220/iCT250 9000002509R1100002/935 11/20 Copyright2009Ingenico Allrightsreserved InstallingSAM(Secureaccessmodule) 4.5. CAUTION:
Beforestarting,switchofftheterminalbydisconnectingthepowersupply. InordertoaccesstheSAMcardyoumustfirstremovetheSAMcompartmentcoverlocated atthebackofyourterminal. Pressdownfirmlyinthemiddleofthecoverandslideitasindicatedbyarrowon thefigurebelow. PRESSHERE Insert the SAM Card into the slot marked (1) or(2). Take caretoensurethattheSAMCardisinsertedinthecorrect manner. The cut corner must be positioned as indicated onthefigure. To remove SAM card, we suggest you to use a piece of adhesive previously pasted on both sides of the SAM as shownherebelow Cutcorner SAM CAUTION:
DonotuseanytoolswheninstallingorremovingtheSAMCard. Adhesive Cutcorner Replacethecoverasillustratedbytheprocedurebelow:
Productname:iCT220/iCT250 9000002509R1100002/935 12/20 Copyright2009Ingenico Allrightsreserved 4.6. InstallingMicroSDCard(optional) CAUTION:
Beforestarting,switchofftheterminalbydisconnectingthepowersupply. Openthecoverasindicatedatchapter4.5 InsertcompletelytheMicroSDCardintothe slotmarked(MicroSD)asindicatedonthe figure. TakecaretoensurethattheMicroSDCardis insertedinthecorrectmanner.The insertionpositionCardisengravedonthe terminal. ToremovetheMicroSDCardpushonitwith yourfingernails. 4.7. InstallingSIMforGPRS(optional) CAUTION:
Beforestarting,switchofftheterminalbydisconnectingthepowersupply. Openthecoverasindicatedatchapter4.5 InserttheSIMGPRSintotheslotmarked(GPRS)asindicatedonthefigure.Donot forceattheinsertion. TakecaretoensurethattheSIMGPRSisinsertedinthecorrectmanner.Theinsertion positionisengravedontheterminal. ToremovetheSIMGPRSpushonitwithyour fingernails. Productname:iCT220/iCT250 9000002509R1100002/935 13/20 Copyright2009Ingenico Allrightsreserved 5. Installingapaperroll Yourterminalissuppliedwithonepaperroll.Whenthepaperrollisnearingtheend,ared linewillappearonthepaper,thisindicatesthatthepaperrollmustbereplaced. CAUTION Useonlypaperapprovedbythemanufacturer(diameter40mm).Useofunsuitablepaper islikelytodamagetheprinterofyourterminal(seecharacteristicsatthechapter7.1). Open the paper compartment by lifting the catch located at the rear of the iCT220/iCT250andpullsthecovertotherearoftheterminal. ATTENTION Donotforcethecoveragainstthecables. LIFT Insert the paper roll in the compartment following the directions shown on the figurebelow. Pullthepaperuptothetopoftheterminalandholditinthisposition. Maintainthepaperandclosethelid. Pressthetopofthelidinthecentreasshownbyarrow,untilitclipsintoposition. ADVICE Ifyouareinsertinganewroll,tearoffthefirstlength(onecompleteturn). Productname:iCT220/iCT250 9000002509R1100002/935 14/20 Copyright2009Ingenico Allrightsreserved 6. Dailyuse 6.1. Keypadfunctions 1 2 3 6 5 1 NAVIGATIONkeysinthemenusInteractivekeysforusebetweenthescreen 2 FUNCTIONkeysF 3 CANCELkey(red) 4 CLEARkey(yellow)/Feedpaper(longpress) 5 VALIDATIONkey(green) 6 DotKey 4 6.2. Adjustingthecontrast NocontrastmanagementfortheColordisplay Thescreenofyourchartis128x64pixels,illuminatedwithwhitelight. Ifyouwishtoincreaseortodecreasethecontrastofthecharactersdisplayedonscreen, press simultaneously on the
(dot key) and key in order to decrease the contrast,orthe
(dotkey)and keyinordertoincrease. Keeppressingthekeysaslongasnecessary. Productname:iCT220/iCT250 9000002509R1100002/935 15/20 Copyright2009Ingenico Allrightsreserved 6.3. Cardinsertion 6.3.1. Swipingacard Insert the card manually in the driver, magstripefacingright. Swipe the card with constant speed, not too slow not too fast, to maximize the readingandavoidannoyingrepetitions. 6.3.2. Insertingachipcard Chip Cards should be inserted into your illustrated with the chip terminal as facingupandintothecardreader 6.3.3. Insertingachipcardinsecondreader
(Optional) Islocatedonbackoftheterminal. Insertthecardupsidedown,magneticstripe visible.(chipnovisible) 6.3.4. ReadingContactless(Optional) Bringthecardfirmlyuptotheactivezoneabovethedisplay(atabout1cm).Keep thecardclosetothedisplayduringthetransaction Yourcontactlessterminalhasarowoffourstatuslightsthatarevisibleondisplay. Whenacontactlesstransactionisstartedthefirst(lefthand)statuslightwillbelit steadily;thisindicatesthatthecontactlessdisplayisinusebutacardisnotbeing read. Green lights Whenacontactlesscardispresentedto thecontactlessactivezoneduringa transactionthesecond,thirdandfourth statuslightswillbelitinturn.Thecard readissuccessfulwhenallfourstatus lightsarelitandtheconfirmationtone isheard. Contactless ActiveZone Productname:iCT220/iCT250 9000002509R1100002/935 16/20 Copyright2009Ingenico Allrightsreserved 7. Maintenance ATTENTION Beforemakinganyoperationsofmaintenanceintheterminal,makesurethat thepowersupplyisdisconnected. 7.1. Paperroll Characteristics Colour Width Diameter Precisions White 58mm 40mmmax. The thermal paper can be deteriorated by poor storage conditions, so we recommendyoutoavoid:
storageinhotwetplaces(neartoairconditioner,humidityhigherthan85%) exposuretosunlightorultravioletforlongperiods contactwithorganicsolvents(solventtypeadhesive) direct contact with materials containing plasticizers (PVC transparent foldersorenvelopes) directcontactwithdiazopapers directcontactwithwater Rubbingorpressingthepapertoostrongly CAUTION Inordertobenefitfromthecompleteguaranteeoftheproduct,onlyheatsensitizedpaper approvedbythemanufacturercanbeused. Productname:iCT220/iCT250 9000002509R1100002/935 17/20 Copyright2009Ingenico Allrightsreserved 7.2. Cleaningoftheterminal Firstofall,unplugallthewiresfromtheterminal. Goodrulesforpropercleaningoftheterminalare:
Useasoftcloththatisveryslightlysoakedwithsoapywatertocleantheoutsideof theterminal. Donotcleantheelectricalconnections. Donotuseinanycase,solvents,detergentsorabrasiveproducts:
Thosematerialsmightdamagetheplasticorelectricalcontacts. Avoidexposingtheterminaltothedirectraysofthesun. Donotputanythingintotheslotofthesmartcardreader 7.3. Transportandstorage Usetheoriginalpackagingforanyunitorstored. Disconnectallcablesfromtheterminalduringthetransport. 7.4. Troubleshooting Theterminaldoesnotturnonordoesnotconnecttothetelephoneline Checkthepowersupplyandtelephonelinecables Checkforelectricalpowernetwork Theterminalfailstoestablishatelephoneconnection Checkthatthetoneofthephonelineisfree Checktheconfigurationofthephonelineandnumbertocall Getsupportfromtechnical Cardsarenotread Checkthatthemagneticcardispassedcorrectly(withmagneticband directedtotheinterioroftheterminal) Swipeagainthecardwiththemagneticstripemovementconstantandrapid Verifythatthemagneticstripisnotdamaged,groovedorcracked Make sure you have inserted correctly the smart card into the smart card reader andremovedthecardonlyafterthetransaction Theticketisnotprinted Checkthepresenceandproperpositioningofthepaperroll. Possiblyadjustthepaperrollfollowinginstructionspresentinthismanual Checkthetypeofpaperused(thermalpapermustbeused) Productname:iCT220/iCT250 9000002509R1100002/935 18/20 Copyright2009Ingenico Allrightsreserved 7.5. Endoflife Theproductbelongstothefamilyofelectricalandelectronicequipment.Therefore,itis subjectedtotheWEEEdirectivewhichrequiresthecollectionandtherecyclingattheend oflifeproduct. TheIngenicoproductspresentthesymbolforthemarkingofelectricalandelectronic equipmentasrequiredbytheWEEEDirective. Thecrossedoutwheeledbinprintedontheproductgivestheinformationabout therequirementnottodisposeofWEEEasunsortedmunicipalwasteandto collectsuchWEEEseparately. Toassurethattheproductiscollectedandrecycledwithrespecttotheenvironment,you mustcontactyoursupplier(indefect,contacttheIngenicolocalofficeorthecommercial headofficeinchargeofyourcountryonwww.ingenico.com,contactuspage). Theabandonmentoruncontrolleddisposalofwastecancauseharmtoenvironmentandto humanhealth.So,byrecyclingyourproductinaresponsiblemanner,youcontributetothe preservationofnaturalresourcesandtotheprotectionofhumanhealth. Productname:iCT220/iCT250 9000002509R1100002/935 19/20 Copyright2009Ingenico Allrightsreserved ThisDocumentisCopyright2009byINGENICOGroup.INGENICOretainsfullcopyrightownership, rights and protection in all material contained in this document. The recipient can receive this documentontheconditionthathewillkeepthedocumentconfidentialandwillnotuseitscontents inanyformorbyanymeans,exceptasagreedbeforehand,withoutthepriorwrittenpermissionof INGENICO.Moreover,nobodyisauthorizedtoplacethisdocumentatthedisposalofanythirdparty withoutthepriorwrittenpermissionofINGENICO.Ifsuchpermissionisgranted,itwillbesubjectto the condition that the recipient ensures that any other recipient of this document, or information containedtherein,isheldresponsibletoINGENICOfortheconfidentialityofthatinformation. Care has been taken to ensure that the content of this document is as accurate as possible.INGENICO however declines any responsibility for inaccurate, incomplete or outdated information.Thecontentsofthisdocumentmaychangefromtimetotimewithoutpriornotice,and do not create, specify, modify or replace any new or prior contractual obligations agreed upon in writingbetweenINGENICOandtheuser. INGENICO is not responsible for any use of this device, which would be non consistent with the presentdocument. Alltrademarksusedinthisdocumentremainthepropertyoftheirrightfulowners. Yourcontact Ingenico 192avenueCharlesdeGaulle 92200NeuillysurSeineFrance Tl.:+33146258200Fax:+33147725695 www.ingenico.com
*
B A 9 7 0 1 1 0 5 9 2
*
Productname:iCT220/iCT250 9000002509R1100002/935 20/20 Copyright2009Ingenico Allrightsreserved
This product uses the FCC Data API but is not endorsed or certified by the FCC