INID XS readers Installation Manual Certifications CE, FCC, IC, UL, ULC FCC ID: YAB-MSXSRDR YAB-SPXSRDR YAB-SRXSRDR 8908A-MSXSRDR (MultiSmart XS readers) 8908A-SPXSRDR
(SmartProx XS readers) 8908A-SRXSRDR
(SmartReader XS readers)
(MultiSmart XS readers)
(SmartProx XS readers)
(SmartReader XS readers) IC:
Consult your National Authority if any authorization is needed for these products. Warning (part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Compliance statement This device complies with part 15 of the FCC Rules and with the Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Information to the User (Part 15.105 (b)) Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Complies with: CAN ICES-3 (B)/NMB-3(B) Operation When a credential is read successfully, the LED bar lights briefly, the sounder sounds a short tone and the credential associated code is sent to the Host system. The LED bar and sounder are also controllable by the Host system. When a PIN is entered the data is sent to the Host system; at each key press a click sound is produced and the LED bar lights briefly. The backlight of the PIN code lights up after a successful credential read, or at the first key press. Reader output formats are determined by the personalization of the credential and/or configuration of the reader; on SmartReader and MultiSmart readers the behaviour of the LED bar and sounder can be modified through configuration. When the reader detects a tamper status, the LED bar flashes red and the tamper output is activated; on SmartReader and MultiSmart readers this behaviour can be modified through configuration. INID BV Overweg 5 1713 HX Obdam The Netherlands Phone: +31 (0)226 450 009 Web: www.inid-readers.com Models interfaces number name 5040C INID SmartReader XS PIN WG/C&D/TTL + RS485 WG/C&D/TTL + RS485 5000C INID SmartReader XS WG/C&D/TTL + RS485 5045C INID MultiSmart XS PIN WG/C&D/TTL + RS485 5005C INID MultiSmart XS WG/C&D/TTL + RS485 5240C INID SmartProx XS PIN 5200C INID SmartProx XS WG/C&D/TTL + RS485 article number 500-5040C 500-5000C 500-5045C 500-5005C 500-5240C 500-5200C Classifications UL 294:
ULC S319:
destructive attack level IV, line security level I, endurance level IV, standby power level I class III Specifications Dimensions 143 x 50 x 25 mm / 5 x 2 x 1 inch Operating temperature
-25 to 65 C / -15 to 150 F Protection class IP54 Complete protection against contact, protection against dust deposit. Protection from splashed water. Power Supply All models 7.0 - 24 Volt DC mA at Vmin at 12 VDC models Watts at Vmax avg peak avg peak avg peak avg peak 65 100 5000C INID SmartReader XS 1,50 2,35 215 340 125 200 65 110 5040C INID SmartReader XS PIN 1,50 2,55 215 365 125 215 5005C INID MultiSmart XS 1,50 2,35 215 340 125 200 65 100 65 110 1,50 2,55 215 365 125 215 5045C INID MultiSmart XS PIN 85 40 75 170 0,85 2,00 125 290 5200C INID SmartProx XS 5240C INID SmartProx XS PIN 0,85 2,00 125 290 75 170 40 85 Note: Ohms Law may be used to estimate current at other voltages. Parts included (1 each) Reader front Mounting backplate Enclosure screw (Torx #8) Installation manual Document 100.14.IS.01 v1.30, effective from SN1632-0001 page 1 of 2 printed on Aug 8, 2016 INID XS readers Installation Manual Cable specifications Shielded cable is required for ULC S319 compliance. The use of stranded conductors cable is highly recommended. Restrict oversizing the cable to a maximum of two sizes. interface Wiegand max. cable length min. conductor size1) meters AWG 61 91 152 25 1.5 61 152 1220 feet 200 300 500 80 5 200 500 4000 mm2 0.25 0.34 0.25 0.25 0.34 0,16 Clock / Data TTL serial RS485 (cable power) RS485 (local power) 1) With a 12 V supply. With a 24 V supply, minimum conductor size is AWG 24 (0.25mm2) for all interfaces and lengths. For locally powered readers the minimum conductor size is AWG 25 (0.16mm2) for all interfaces and lengths. 24 22 24 24 22 25 Connector Assignments connector position interface Wiegand Clock/Data TTL serial 3 D1 4 D0 1 2 5 6 7 8 LED1-green LED2-red BUZZER TAMPER GND POWER LED1-green LED2-red DATA CLOCK BUZZER TAMPER GND POWER TAMPER GND POWER LED1-green LED2-red TAMPER GND POWER TXE TRX-
RXD N.C. INPUT 3 TXD RS485 standard LED1-green LED2-red TRX+
Caution INPUT 1 INPUT 2 OSDP Floating communication lines may cause spurious emissions, invalidating certification. Ensure all communication lines are properly biased and terminated. 3. Pull the cable trough the hole in the backplate; protect the cable against sharp edges and any damage from chafing. 4. Mount the backplate using flat head screws with a shank size of 4mm (5/32, #7) or smaller; other screw types or sizes may cause irrepairable damage to the reader. 5. Prepare the end of the cable and wires, eliminating any loose or frayed strands; for stranded conductors, the use of ferrules is highly recommended. Keep the wire ends as short as practical. 6. Connect the wires to the connector according to the interface type. Wire ends, termination resistor leads and optional permanent links shall be kept as short as possible. Use an appropriate sized screwdriver and do not over-tighten the connector screws. 7. Place the reader front section over the hinge of the backplate (see drawing) and close the reader, keeping the wiring in the lower part of the reader housing. DO NOT use excessive force, retract the cable if necessary. 8. Test the reader: apply power and present a valid credential. The LED bar should flash and the sounder should produce a short tone indicating a successful read. If the Host system is connected to the LED bar and sounder inputs these should follow the functionality of the Host system. Note:
The reader must be fully closed or the tamper circuit will activate, indicated by a flashing LED bar. 9. The reader front can now be secured to the backplate using the supplied enclosure screw. SmartProx XS DIP switch settings 1 2 3 4 5 6 7 PIN card type factory default:
all switches off. output format format1) off off off on on off on on H-PX & A-PX EM4102 PX light QKEY off off off off off on off on off off on on on off off on off on on on off on on on off off off on on off on on AUTO (H-PX & A-PX only) WG 26 WG 32 WG 34 WG 37 WG 40 WG 42 ABA 10 WG 4 WG 8 WG 4+4 CLK/DTA trk2 ABA Note Selecting AUTO format for cards EM4102, PX light or QKEY will cause unpredictable behaviour. 1) Not functional in readers without PIN pad. Installation instructions All wiring shall be in accordance with appliccable codes and regulations
(USA: ANSI/NFPA70; Canada: CSA C22.1) use ONLY flat head screws, maximum shank size 4mm (5/32, #7) 1. Determine an appropriate position for the reader; a height of 140 cm (55 inches) above floor level on the doorjamb at the lock side of the door is recommended. Observe applicable building codes and safety regulations in determining the reader position. Notes:
Mounting readers in close proximity of each other wil reduce performance. The minimum recommended mounting distance side-by-side or back-to-back is 125mm (5). Closer mounting will reduce performance, or cause unintentional reads on the other reader; magnetic shielding may be necessary in that case. Mounting the reader on a metal surface will reduce performance, See Application Note AN100.14001 on the INID website for more a plastic separator of at least 6mm () is recommened. details. 2. Drill two pilot holes for mounting the backplate and one hole for the cable, see drawing for measurements. Document 100.14.IS.01 v1.30, effective from SN1632-0001 page 2 of 2 printed on Aug 8, 2016