INID ISO14443 readers 2.4 inch 1.2 inch Mifare ISO card 60 mm 30 mm Specifications Typical read range Model INID ISO14443 AC INID ISO14443 Power Supply 7 - 24 Volt DC (12 VDC recommended) Power consumption model INID ISO14443 AC INID ISO14443 AC PIN INID ISO14443 INID ISO14443 PIN Current consumption @12 VDC1) model INID ISO14443 AC INID ISO14443 AC PIN INID ISO14443 INID ISO14443 PIN 1) Use Ohm's law to calculate current at different voltages. average 1300 mW 1300 mW 500 mW 500 mW average 110 mA 110 mA 42 mA 42 mA peak 1750 mW 2050 mW 950 mW 1250 mW peak 146 mA 171 mA 79 mA 105 mA Interface Inputs type and protection specifics Outputs type and protection specifics Dimensions 143 x 50 x 25 mm / 5.63 x 2 x 1 inch Material UL94-V0 rated LEXAN 925U Operating temperature
-25 to 65 C / -15 to 150 F Protection class IP54 Complete protection against contact, protection against dust deposit. Protection from splashed water. Cable specifications (non-shielded) interface Wiegand Clock/Data TTL serial RS232 RS485/RS422
(cable power) RS485/RS422
(local power) CAN bus meters maximum cable length feet 200 300 500 80 5 8 200 500 4000 61 91 152 25 1.5 2.4 61 152 1220 min.conductor size with 12 V supply2) AWG mm2 24 0.25 0.34 22 0.25 0.34 0.25 24 22 24 system / speed dependent 2) With a 24V supply, minimum conductor size is AWG 24 for all interfaces and lengths. Features INID readers have a slim mullion mountable design and are designed for both in- and outdoor use. The INID reader can be mounted on any surface without significant performance degradation. For mounting to a metal surface however, a non-metallic spacer is advised. The switch mode power supply of the reader accepts a wide range input from 7 - 24 VDC. Higher input voltages result in lower current consumption and allow for cost effective wiring with a smaller conductor diameter. Reader output formats are determined by the personalization of the card and/or configuration of the reader. Separate models are available for card-only and card+PIN; for Access Control with a larger read range and low power with a smaller read range. Electrical interface options for WG/C&D/TTL serial, RS485/RS422, RS232 and CAN bus are available with separate models. PIN code INID PIN readers provide extensive options for PIN data formats and output protocols. The card and PIN code data is sent separately and independently allowing host system determined operation for card-
only, PIN-only and card and PIN usage. Indications User feedback is provided by a single LED bar and a multi-tone sounder. User feedback is controllable by the host system. PIN models are equipped with back lighting of the PIN code digits for usage in dark environments. Operation When a proximity card is read successfully the card associated code is send to the Host system, the LED bar lights briefly and the sounder sounds a short tone. When a PIN is entered the data is transmitted; at each key press a click sound is produced and the LED bar lights briefly. The back light of the PIN code lights up after a successful card read or at the first key press. The LED bar or individual LED bar segments and the buzzer are also controllable by the Host system. INID ISO14443 readers - installation and operation manual version 1.06; February 2nd, 2011 Connector Assignments Wiegand / Clock and Data / TTL serial 500-5000 INID ISO14443 AC reader WG/C&D/TTL 500-5040 INID ISO14443 AC PIN reader WG/C&D/TTL 500-5100 INID ISO14443 reader WG/C&D/TTL 500-5140 INID ISO14443 PIN reader WG/C&D/TTL 1 LED 1 - Green 2 LED 2 - Amber 3 D1 DATA TXD 4 D0 CLOCK TXE RS485 / RS422 RXD 5 BUZZER 6 TAMPER 7 GND 8 POWER 500-5010 INID ISO14443 AC reader RS485/RS422 500-5050 INID ISO14443 AC PIN reader RS485/RS422 500-5110 INID ISO14443 reader RS485/RS422 500-5150 INID ISO14443 PIN reader RS485/RS422 1 LED 1 - Green 2 LED 2 - Amber 3 RS485 TRX+ RS422 TX+ 7 GND 4 RS485 TRX- RS422 TX- 8 POWER Caution: floating communication lines may cause spurious emissions. Ensure all communication lines are properly biased and terminated. RS232 5 RS485 n.c. RS422 RX-
6 RS485 n.c. RS422 RX+
500-5020 INID ISO14443 AC reader RS232 500-5060 INID ISO14443 AC PIN reader RS232 500-5120 INID ISO14443 reader RS232 500-5160 INID ISO14443 PIN reader RS232 5 RTS 6 RXD 7 GND 8 POWER 1 LED 1 - Green 2 LED 2 - Amber 3 CTS 4 TXD CAN bus 500-5030 INID ISO14443 AC reader CAN bus 500-5070 INID ISO14443 AC PIN reader CAN bus 500-5130 INID ISO14443 reader CAN bus 500-5170 INID ISO14443 PIN reader CAN bus 5 n.c. 1 LED 1 - Green 6 n.c. 2 LED 2 - Amber 7 GND 3 CANL 4 CANH 8 POWER Parts list 1 Reader front 2 Terminal connector 3 Mounting backplate 4 Enclosure screw 5 Installation sheet Installation instructions 1 Determine an appropriate position for the reader qty: 1 qty: 1 qty: 1 qty: 1 qty: 1 and drill two holes for mounting the backplate and one hole for the cable, see diagram for measurements. Do not mount readers less than 20 cm (8 inches) apart. 2 Pull the cable trough the hole in the backplate and mount the backplate. Protect the cable against sharp edges and any damage from chafing. 3 Remove the terminal connector from the front of the reader. Prepare the end of the cable and wires, eliminate any loose or frayed strands. Keep the wire ends as short as practical. 4 Connect the wires to the connector according to the reader type. Wire ends, termination resistor leads and optional permanent links shall be kept as short as possible. 5 Place the connector on the reader pins. 6 Place the reader front over the hinge of the backplate and close the reader (see diagram), keeping the wiring in the lower part of the reader housing. DO NOT use excessive force, retract the cable if necessary. For mounting, use only flat head screws with a maximum shank size of 4 mm (5/32, #7) 7 Test the reader: apply power and present a valid card. The LED bar should flash and the sounder should produce a short tone indicating a successful read. If the Host system is connected to LED bar and sounder inputs these should follow the functionality of the Host system. 8 The reader front should now be secured to the backplate using the supplied enclosure screw. Certifications CE, FCC FCC ID: YAB-ISOACRDR (model 50XX)
(model 51XX) YAB-ISORDR Compliance statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Warning (part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This in particular is applicable for the antenna which has been delivered with the reader. Consult your National Authority if any authorization is needed for this product. INID BV Kollenbergweg 78c 1101AV Amsterdam Zuidoost The Netherlands Phone: +31 (0)20 6967 441 Web: www.inid-readers.com INID ISO14443 readers - installation and operation manual version 1.06; February 2nd, 2011