all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manual | photos | labels |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users Manual | Users Manual | 5.06 MiB | ||||
1 |
|
Internal Photos | Internal Photos | 1.76 MiB | ||||
1 |
|
External Photos | External Photos | 1.60 MiB | ||||
1 |
|
Label | ID Label/Location Info | 122.61 KiB | ||||
1 |
|
Label Location | ID Label/Location Info | 485.07 KiB | ||||
1 |
|
Authorization letter | Cover Letter(s) | 318.49 KiB | ||||
1 | Block Diagram | Block Diagram | September 23 2015 | confidential | ||||
1 |
|
Declaration on Model Differences | Cover Letter(s) | 14.91 KiB | ||||
1 |
|
LTC letter | Cover Letter(s) | 21.39 KiB | ||||
1 | Operational Description | Operational Description | September 23 2015 | confidential | ||||
1 |
|
RF Exposure Report | RF Exposure Info | 105.23 KiB | ||||
1 | Schematics | Schematics | September 23 2015 | confidential | ||||
1 |
|
Test Report | Test Report | 4.42 MiB | ||||
1 |
|
Test Setup photos | Test Setup Photos | 425.94 KiB |
1 | Users Manual | Users Manual | 5.06 MiB |
Bluetooth Boombox with Rubberized Finish Model:CR-S308 / ITSB-352 FCC ID: 2AFHW-ITSB352 IC ID: 9557A-ITSB352 installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. RF warning statement:
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. CANADA STATEMENT:
" This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device."
Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil nedoit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compro mettre le fonctionnement."
5 FCC STATEMENT :
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
1 | Internal Photos | Internal Photos | 1.76 MiB |
Figure 8 The EUT-Inside View Figure 9 The EUT-Inside View Figure 10 PCB of the EUT-Front View Figure 11 PCB of the EUT-Back View Figure 12 PCB of the EUT-Front View Figure 13 PCB of the EUT-Back View Antenna
1 | External Photos | External Photos | 1.60 MiB |
Figure 1 The EUT-Overall View Figure 2 The EUT-Top View Figure 3 The EUT-Bottom View Figure 4 The EUT-Front View Figure 5 The EUT-Back View Figure 6 The EUT-Right View Figure 7 The EUT-Left View
1 | Label Location | ID Label/Location Info | 485.07 KiB |
nr MTT ti F
3 pee o 3 SS 4 3 =
4 s =
2 a
$ s4 3
<4 cd a 3 c= ; Z 2 I : :
s ee ee reer TTR a ON A OA
=. ee Ce Te Ya ele
, Te OR RR ROR Ca i oe Ma TTT lia AMINA PUPP MM MPY ITO MMMIAMRY UTR UTMROUTEUUTLNNOUUATTNU TT PLACEMENT Centered on the Front Bottom Panel Front of Seaker innovative technology. Manufactured / Fabriqu: 082015 MADE IN CHINA/ FABRIQUE EN CHINE Model / Modle: ITSB-352 CAN ICES-3 (B) / NMB-3 (B) Bluetooth Boombox with Rubberized Finish / Serial No / NDe Srie. 150900001 Boombox Bluetooth avec Finition Caoutchoute eee oe om avr ne . FCC ID: 2AFHW-ITSB352 PE Cla esr Cy o This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device 2015 innovative technology must accept any interference received, including interference that may cause undesired www. ithomeproducts.com operation / Cet appareil est conforme a la partie 15 des rgles de la FCC. Son Cc iz en . fonctionnement est soumis aux deux conditions suivantes : (1) Cet appareil ne doit pas ee NS causer dinterfrences nuisibles. (2) Cet appareil doit accepter toute interfrence regue, Port Washington, NY 11050 y compris des interfrences qui peuvent provoquer un fonctionnement non dsir Bottom of Seaker
1 | Authorization letter | Cover Letter(s) | 318.49 KiB |
y) 775 Montague Expressway Milpitas, CA 95035 EMIC el a Email: TCB@siemic.com rn }
S Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept-25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (current) 4.0 5.0 Sept 16 2014 SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 5.0
(Innovative Technology Electronics Corp.)
(2015-09-16) To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, Innovative Technology Electronics Corp. ____hereby authorize SIEMIC, Inc. to act as a Certification Body for certifying for the following project(s):
Product description: Bluetooth Boombox with Rubberized Finish Model name: ITSB-352, CR-S308 FCC ID: 2AFHW-ITSB352 Sincerely, Client's signature Martha Park / COO Company Name: Innovative Technology Electronics Corp. Address: 1 Channel Drive, Port Washington, NY 11050, USA Email: Martha.Park@|ITHomeProducts.com SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 5.0
1 | Declaration on Model Differences | Cover Letter(s) | 14.91 KiB |
Innovative Technology Electronics Corp. Declaration on Model Differences We, Innovative Technology Electronics Corp. 1 Channel Drive, Port Washington, NY 11050, USA Declare that the following product(s):
Product Name: Bluetooth Boombox with Rubberized Finish Model Number: ITSB-352, CR-S308 FCC ID: 2AFHW-ITSB352 Utilize the identical circuit design, PCB layout, shielding and interface with (ITSB-352), only the model number and colour are difference. Therefore this application can be regarded as identical in performance to the submitted test sample. The manufacturer would take all the responsibilities for the above product(s). For and on behalf of Authorized person Location Port Washington, NY, USA Name: Martha Park Position: COO Date of issue: 2015-09-16
*I hereby declare that I am entitled to sign on behalf of the applicant and that the information supplied is correct and complete.
1 | LTC letter | Cover Letter(s) | 21.39 KiB |
775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: TCB@siemic.com Confidentiality Request Letter Reason for Amendment (current / obsolete) Initial Release (obsolete) Adding CFR 2.459 (obsolete) Updated company template & Added text box
(obsolete) Added IC confidentiality letter form (current) Revision History From 1.0 1.0 2.0 3.0 To 1.0 2.0 3.0 4.0 Approved Date Nov-14-2006 August 11 - 2008 Jan-31-2012 March-26-2015 SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 4.0
(Innovative Technology Electronics Corp.)
(2015-09-16) To:
Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: 2AFHW-ITSB352 We hereby request confidential treatment of information accompanying this application as outlined below:
- Block Diagram
- Schematics
- Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Martha Park / COO Company Name: Innovative Technology Electronics Corp. Address: 1 Channel Drive, Port Washington, NY 11050, USA SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 4.0
1 | RF Exposure Report | RF Exposure Info | 105.23 KiB |
RF EXPOSURE EVALUATION FCC ID2AFHW-ITSB352 According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency(RF) Radiation as specified in 1.1307(b):
Routine SAR evaluation refers to that specifically required by 2.1093, using measurements or computer simulation. When routine SAR evaluation is not required, portable transmitters with output power greater than the applicable low threshold require SAR evaluation to qualify for TCB approval. Mode: BDR The maximum output power for low channel is: 2.009dBm= 1.588mW Tune up tolerance is: 2.0091 dBm The Max. Tune up Power =3.009dBm= 1.999mW The calculation results= 1.999/5*2.402 =0.620 3 The maximum output power for middle channel is: 2.202dBm= 1.660mW Tune up tolerance is: 2.2021 dBm The Max. Tune up Power =3.202dBm= 2.090mW The calculation results= 2.090/5*2.441=0.653 3 The maximum output power for high channel is: 2.615dBm= 1.826mW Tune up tolerance is: 2.6151 dBm The Max. Tune up Power =3.615dBm= 2.299mW The calculation results= 2.299/5*2.480=0.724 3 Mode: EDR The maximum output power for low channel is: 1.891dBm= 1.546mW Tune up tolerance is: 1.8911 dBm The Max. Tune up Power =2.891dBm= 1.946mW The calculation results= 1.946/5*2.402 =0.603 3 The maximum output power for middle channel is: 1.483dBm= 1.407mW Tune up tolerance is: 1.4831 dBm The Max. Tune up Power =2.483dBm= 1.771mW The calculation results= 1.771/5*2.441=0.553 3 The maximum output power for high channel is: 1.795dBm= 1.512mW Tune up tolerance is: 1.7951 dBm The Max. Tune up Power =2.795dBm= 1.903mW The calculation results= 1.903/5*2.480=0.599 3 Test Results: PASS.
1 | Test Report | Test Report | 4.42 MiB |
Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 1 of 51 Report No.: R011508417I FCC TEST REPORT for Innovative Technology Electronics Corp. Bluetooth Boombox with Rubberized Finish Model No.: ITSB-352, CR-S308 Prepared for Address Innovative Technology Electronics Corp.
:
: 1 Channel Drive, Port Washington, NY 11050, USA Prepared By Address
: Shenzhen Anbotek Compliance Laboratory Limited
: 1/F., Building 1, SEC Industrial Park, No.0409 Qianhai Road, Nanshan District, Shenzhen, Guangdong, China Tel: (86) 755-26066544 Fax: (86) 755-26014772 Report Number Date of Test Date of Report
: R011508417I
: Aug. 13~ 28, 2015
: Aug. 31, 2015 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 2 of 51 Report No.: R011508417I TABLE OF CONTENTS Page Description Test Report 1. GENERAL INFORMATION......................................................................................................5 1.1 Description of Device (EUT).................................................................................................................5 1.2 Auxiliary Equipment Used during Test................................................................................................. 6 1.3 Description of Test Facility................................................................................................................... 6 1.4 Measurement Uncertainty......................................................................................................................6 2. TEST PROCEDURE....................................................................................................................7 3. CONDUCTED EMISSION......................................................................................................... 8 3.1 Block Diagram of Test Setup.................................................................................................................8 3.2 Power Line Conducted Emission Measurement Limits (15.207)..........................................................8 3.3 Configuration of EUT on Measurement................................................................................................ 8 3.4 Operating Condition of EUT................................................................................................................. 8 3.5 Test Procedure....................................................................................................................................... 9 3.6 Power Line Conducted Emission Measurement Results....................................................................... 9 4. RADIATION INTERFERENCE.............................................................................................. 14 4.1 Requirements (15.247, 15.209):...........................................................................................................14 4.2 Test Procedure..................................................................................................................................... 14 4.3 Test Configuration............................................................................................................................... 15 4.4 Test Results..........................................................................................................................................16 5. CHANNEL SEPARATION TEST............................................................................................25 5.1 Measurement Procedure.......................................................................................................................25 5.2 Test SET-UP........................................................................................................................................ 25 5.3 Test Equipment.................................................................................................................................... 25 5.4 Test Results..........................................................................................................................................26 6. 20DB BANDWIDTH TEST.......................................................................................................28 6.1 Measurement Procedure.......................................................................................................................28 6.2 Test SET-UP........................................................................................................................................ 28 6.3 Test Equipment.................................................................................................................................... 28 6.4 Test Results..........................................................................................................................................28 7. QUANTITY OF HOPPING CHANNEL TEST...................................................................... 30 7.1 Measurement Procedure.......................................................................................................................30 7.2 Test SET-UP........................................................................................................................................ 30 7.3 Test Equipment.................................................................................................................................... 30 7.4 Test Results..........................................................................................................................................30 8. DWELL TIME TEST................................................................................................................ 32 8.1 Measurement Procedure.......................................................................................................................32 8.2 Test SET-UP........................................................................................................................................ 32 8.3 Test Equipment.................................................................................................................................... 32 8.4 Test Results..........................................................................................................................................32 9. MAX IMUM PEAK OUTPUT POWER TEST.......................................................................34 9.1 Measurement Procedure.......................................................................................................................34 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 3 of 51 Report No.: R011508417I 9.2 Test SET-UP........................................................................................................................................ 34 9.3 Test Equipment.................................................................................................................................... 34 9.4 Test Results..........................................................................................................................................35 10. BAND EDGE TEST................................................................................................................. 37 10.1 Measurement Procedure.....................................................................................................................37 10.2 Test SET-UP...................................................................................................................................... 37 10.3 Test Equipment.................................................................................................................................. 38 10.4 Test Results........................................................................................................................................38 11. ANTENNA APPLICATION....................................................................................................42 11.1 Antenna requirement..........................................................................................................................42 11.2 Result................................................................................................................................................. 42 12. PHOTOGRAPH....................................................................................................................... 43 12.1 Photo of Power Line Conducted Emission Measurement................................................................. 43 12.2 Photo of Radiation Emission Test......................................................................................................43 APPENDIX I (EXTERNAL PHOTOS)........................................................................................45 APPENDIX (INTERNAL PHOTOS)....................................................................................... 49 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 4 of 51 Report No.: R011508417I TEST REPORT Applicant Manufacturer EUT Model No. Serial No. Trade Mark Rating Innovative Technology Electronics Corp.
:
: CROSBY LIMITED
: Bluetooth Boombox with Rubberized Finish
:
: N.A.
:
: DC 5V, 1.0A (With DC 3.7V, 2000mAh Battery Inside) Innovative Technology ITSB-352, CR-S308 Measurement Procedure Used:
FCC Part15 Subpart C 2014, Paragraph 15.207, 15.247 & 15.209 The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these measurements. Also, the EUT (Equipment Under Test) is technically compliant with the FCC Part 15 Subpart C requirements. This report applies to above tested sample only and shall not be reproduced in part without written approval of Shenzhen Anbotek Compliance Laboratory Limited. this report shows that Date of Test :
Aug. 13~ 28, 2015 Prepared by :
Reviewer :
(Tested Engineer / Kebo Zhang)
(Project Manager / Amy Ding) Approved & Authorized Signer :
(Manager / Tom Chen) Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 5 of 51 Report No.: R011508417I 1. GENERAL INFORMATION 1.1 Description of Device (EUT) EUT
: Bluetooth Boombox with Rubberized Finish Model Number
: ITSB-352, CR-S308
(Note: All samples are the same except the model number and colour, so we prepare ITSB-352 for test only.) Test Power Supply : AC 120V, 60Hz for adapter/
AC 240V, 60Hz for adapter/
DC 3.7V Battery inside Frequency
: 2402~2480MHz Antenna Specification
: PCB Antenna: 1.9dBi Modulation
: GFSK, /4DQPSK, 8DPSK Applicant Address
: Innovative Technology Electronics Corp.
: 1 Channel Drive, Port Washington, NY 11050, USA Manufacturer Address
: CROSBY LIMITED
: Room 201B Floor 2, Lee Wai Commercial Building, 1-3 Hart Avenue, T.S.T., Kowloon, Hong Kong Factory Address
: CROSBY LIMITED
: Room 201B Floor 2, Lee Wai Commercial Building, 1-3 Hart Avenue, T.S.T., Kowloon, Hong Kong Date of receipt
: Aug. 13, 2015 Date of Test
: Aug. 13~ 28, 2015 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 6 of 51 Report No.: R011508417I 1.2 Auxiliary Equipment Used during Test Adapter
: Manufacturer: Samsung M/N: ETA-U90CBC S/N: RT6FB17ZS/B-E Input: AC 100-240V, 50-60Hz, 0.35A Output: DC 5V, 2A 1.3 Description of Test Facility The test facility is recognized, certified, or accredited by the following organizations:
CNAS - LAB Code: L3503 Shenzhen Anbotek Compliance Laboratory Limited., Laboratory has been assessed and in compliance with CNAS/CL01: 2006 accreditation criteria for testing laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of Testing Laboratories. FCC-Registration No.: 752021 Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration 752021, July 10, 2013. IC-Registration No.: 8058A-1 Shenzhen Anbotek Compliance Laboratory Limited., EMC Laboratory has been registered and fully described in a report filed with the (IC) Industry Canada. The acceptance letter from the IC is maintained in our files. Registration 8058A, February 22, 2013. Test Location All Emissions tests were performed at Shenzhen Anbotek Compliance Laboratory Limited. at 1/F., Building 1, SEC Industrial Park, No.0409 Qianhai Road, Nanshan District, Shenzhen, Guangdong, China 1.4 Measurement Uncertainty
:
Radiation Uncertainty Ur = 4.1 dB (Horizontal) Ur = 4.3 dB (Vertical) Conduction Uncertainty
:
Uc = 3.4dB Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 7 of 51 Report No.: R011508417I 2. Test Procedure GENERAL: This report shall NOT be reproduced except in full without the written approval of Shenzhen Anbotek Compliance Laboratory Limited. The EUT was transmitting a test signal during the testing. RADIATION INTERFERENCE: The test procedure used was ANSI STANDARD C63.10-2013 using a spectrum analyzer with a pre-selector. The analyzer was calibrated in dB above a microvolt at the output of the antenna. The resolution bandwidth was 100KHz and the video bandwidth was 300KHz up to 1.0GHz and 1.0MHz with a video BW of 3.0MHz above 1.0GHz. The ambient temperature of the EUT was 74.3oF with a humidity of 69%. FORMULA OF CONVERSION FACTORS: The Field Strength at 3m was established by adding the meter reading of the spectrum analyzer (which is set to read in units of dBuV) to the antenna correction factor supplied by the antenna manufacturer. The antenna correction factors are stated in terms of dB. The gain of the Preselector was accounted for in the Spectrum Analyzer Meter Reading. Example:
Freq (MHz) METER READING + ACF = FS 20 dBuV + 10.36 dB = 30.36 dBuV/m @ 3m ANSI STANDARD C63.10-2013 10.1.7 MEASUREMENT PROCEDURES: The EUT was placed on a table 80 cm high and with dimensions of 1m by 1.5m. The EUT was placed in the center of the table (1.5m side). The table used for radiated measurements is capable of continuous rotation. When an emission was found, the table was rotated to produce the maximum signal strength. At this point, the antenna was raised and lowered from 1m to 4m. The antenna was placed in both the horizontal and vertical planes. Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 8 of 51 Report No.: R011508417I 3. Conducted Emission 3.1 Block Diagram of Test Setup 3.1.1. Block diagram of connection between the EUT and simulators Test Receiver AC mains L.I.S.N Adapter EUT 3.2 Power Line Conducted Emission Measurement Limits (15.207) Frequency MHz 0.50 0.15 ~
0.50 ~
5.00 5.00 ~ 30.00 Limits dB(mV) Quasi-peak Level 66 ~ 56*
56 60 Average Level 56 ~ 46*
46 50 Notes: 1. *Decreasing linearly with logarithm of frequency. 2. The lower limit shall apply at the transition frequencies. 3.3 Configuration of EUT on Measurement The following equipments are installed on Power Line Conducted Emission Measurement to meet the commission requirement and operating regulations in a manner which tends to maximize its emission characteristics in a normal application. 3.4 Operating Condition of EUT 3.4.1. Setup the EUT and simulator as shown as Section 3.1. 3.4.2. Turn on the power of all equipment. 3.4.3. Let the EUT work in test mode (Charging) and measure it. Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 9 of 51 Report No.: R011508417I 3.5 Test Procedure The EUT system is connected to the power mains through a line impedance stabilization network (L.I.S.N.). This provides a 50ohm coupling impedance for the EUT system. Please refer the block diagram of the test setup and photographs. Both sides of AC line are checked to find out the maximum conducted emission. In order to find the maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed according to FCC ANSI C63.10-2013 on Conducted Emission Measurement. The bandwidth of test receiver (ESCI) set at 9KHz. The frequency range from 150KHz to 30MHz is checked. The test results are reported on Section 3.6. Item 1. Test Equipment Equipment Two-Line V-network Manufacturer Model No. Serial No. Last Cal. Cal. Interval Rohde & Schwarz ENV216 2. EMI Test Receiver Rohde & Schwarz 3. RF Switching Unit Compliance Direction ESCI RSU-M2 38303 Apr. 17, 2015 100055 Apr. 17, 2015 100627 Apr. 17, 2015 1 Year 1 Year 1 Year 3.6 Power Line Conducted Emission Measurement Results PASS. The frequency range from 150KHz to 30 MHz is investigated. Please refer the following pages. Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 10 of 51 Report No.: R011508417I CONDUCTED EMISSION TEST DATA Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Charging AC 120V, 60Hz for adapter Live Line Tem.:25 Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 11 of 51 Report No.: R011508417I CONDUCTED EMISSION TEST DATA Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Charging AC 120V, 60Hz for adapter Neutral Line Tem.:25 Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 12 of 51 Report No.: R011508417I CONDUCTED EMISSION TEST DATA Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Charging AC 240V, 60Hz for adapter Live Line Tem.:25 Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 13 of 51 Report No.: R011508417I CONDUCTED EMISSION TEST DATA Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Charging AC 240V, 60Hz for adapter Neutral Line Tem.:25 Hum.:50%
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 14 of 51 Report No.: R011508417I 4. Radiation Interference 4.1 Requirements (15.247, 15.209):
Field Strength 4.1.1. Test Limits (< 30 MHZ) Frequency
(MHz) 0.009-0.490 0.490-1.705 1.705-30.0 2400/F(kHz) 24000/F(kHz) 30
(microvolts/meter) Measurement Distance
(meter) 300 30 30 4.1.2. Test Limits ( 30 MHZ) FIELD STRENGTH of Fundamental:
@3M 902-928 MHZ 2.4-2.4835 GHz 94 dBV/m @3m FIELD STRENGTH of Harmonics 54 dBV/m @3m S15.209 30 - 88 MHz 40 dBuV/m 88 - 216 MHz 216 - 960 MHz ABOVE 960 MHz 43.5 46 54dBuV/m For range 9KHz~30MHz, The measured value is really too low to be recorded. Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general radiated emission limits in 15.209, whichever is the lesser attenuation. 4.2 Test Procedure For below 1GHz: The EUT is placed on a turntable, which is 0.8m above the ground plane. For above 1GHz: The EUT is placed on a turntable, which is 1.5m above the ground plane. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The antenna can be moved up and down from 1 to 4 meters to find out the maximum emission level. Rotated the EUT through three orthogonal axes to determine the maximum emissions, both horizontal and vertical polarization of the antenna are set on test. The EUT is tested in 9*6*6 Chamber. The device is evaluated in xyz orientation. For 30MHz to 1000MHz:
Set the spectrum analyzer as:
RBW = 100kHz, VBW =300kHz, Detector= Quasi-Peak Trace mode= Max hold. Sweep- auto couple. For Above 1GHz:
Set the spectrum analyzer as:
RBW = 1MHz, VBW =3MHz, Detector= Peak Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 15 of 51 Report No.: R011508417I Trace mode= Max hold. Sweep- auto couple. Set the spectrum analyzer as:
RBW =1MHz, VBW =10Hz Detector= Average Trace mode= Max hold. Sweep- auto couple. Test Equipment Item 1. Spectrum Analysis Equipment 2. Preamplifier Manufacturer Model No. Serial No. Last Cal. Cal. Interval E4407B US39390582 Apr. 17, 2015 Agilent Instruments corporation EMC01183 0 980100 101604 351600 VULB 9163-289 186860 Apr. 17, 2015 Apr. 17, 2015 Apr. 20, 2015 Apr. 20, 2015 Apr. 17, 2015 N/A N/A 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year N/A 3. EMI Test Receiver Rohde & Schwarz ESPI Double Ridged 4. Horn Antenna 5. Bilog Broadband Pre-amplifier 6. Antenna 7. EMI Test Software EZ-EMC Instruments corporation GTH-0118 Schwarzbeck VULB9163 SONOMA SHURPLE 310N N/A 4.3 Test Configuration 4.3.1. 9k to 30MHz emissions:
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 16 of 51 Report No.: R011508417I 4.3.2. 30M to 1G emissions:
4.3.3. 1G to 40G emissions:
4.4 Test Results PASS. The EUT was tested on (Charging, BT Mode) modes, only the worst data of (BT Mode) is attached in the following pages. Only the worst case (x orientation). Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 17 of 51 Report No.: R011508417I Job No.:
Standard:
Test item:
011508417I Polarization:
(RE)FCC PART 15C _3m Power Source:
Horizontal DC 3.7V Radiation Test (30~1000MHz) Temp.(C)/Hum.(%RH):
24.3(C)/55%RH Test Mode:
BT Mode Distance:
3m Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 18 of 51 Report No.: R011508417I Job No.:
Standard:
Test item:
011508417I Polarization:
(RE)FCC PART 15C _3m Power Source:
Vertical DC 3.7V Radiation Test (30~1000MHz) Temp.(C)/Hum.(%RH):
24.3(C)/55%RH Test Mode:
BT Mode Distance:
3m Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 19 of 51 Report No.: R011508417I Job No.:
Standard:
Test item:
Test Mode:
011508417I Polarization:
(RE)FCC PART 15C_Class B_3m Power Source:
Horizontal DC 3.7V Radiation Test (Above 1GHz) Temp.(C)/Hum.(%RH):
24.3(C)/55%RH TX(2402 MHz) Distance:
3m Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 20 of 51 Report No.: R011508417I Job No.:
Standard:
Test item:
Test Mode:
011508417I Polarization:
(RE)FCC PART 15C_Class B_3m Power Source:
Vertical DC 3.7V Radiation Test (Above 1GHz) Temp.(C)/Hum.(%RH):
24.3(C)/55%RH TX(2402 MHz) Distance:
3m Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 21 of 51 Report No.: R011508417I Job No.:
Standard:
Test item:
Test Mode:
011508417I Polarization:
(RE)FCC PART 15C_Class B_3m Power Source:
Horizontal DC 3.7V Radiation Test (Above 1GHz) Temp.(C)/Hum.(%RH):
24.3(C)/55%RH TX(2441 MHz) Distance:
3m Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 22 of 51 Report No.: R011508417I Job No.:
Standard:
Test item:
Test Mode:
011508417I Polarization:
(RE)FCC PART 15C_Class B_3m Power Source:
Vertical DC 3.7V Radiation Test (Above 1GHz) Temp.(C)/Hum.(%RH):
24.3(C)/55%RH TX(2441 MHz) Distance:
3m Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 23 of 51 Report No.: R011508417I Job No.:
Standard:
Test item:
Test Mode:
011508417I Polarization:
(RE)FCC PART 15C_Class B_3m Power Source:
Horizontal DC 3.7V Radiation Test (Above 1GHz) Temp.(C)/Hum.(%RH):
24.3(C)/55%RH TX(2480 MHz) Distance:
3m Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 24 of 51 Report No.: R011508417I Job No.:
Standard:
Test item:
Test Mode:
011508417I Polarization:
(RE)FCC PART 15C_Class B_3m Power Source:
Vertical DC 3.7V Radiation Test (Above 1GHz) Temp.(C)/Hum.(%RH):
24.3(C)/55%RH TX(2480 MHz) Distance:
3m Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 25 of 51 Report No.: R011508417I 5. CHANNEL SEPARATION TEST 5.1 Measurement Procedure The EUT must have its hopping function enabled. Using the following spectrum analyzer settings:
1. Span= Wide enough to capture the peaks of two adjacent channels 2. Set the RBW = 30 kHz. 3. Set the VBW = 100 kHz. 4. Sweep time = auto couple. 5. Detector function = peak. 6. Trace mode = max hold. 7. Allow trace to fully stabilize. 5.2 Test SET-UP EUT Spectrum analyzer 3. EMI Test Receiver Rohde & Schwarz 5.3 Test Equipment Item 1. Spectrum Analysis Equipment 2. Preamplifier Double Ridged 4. Horn Antenna 5. Bilog Broadband Pre-amplifier 6. Antenna 7. EMI Test Software EZ-EMC Manufacturer Model No. Serial No. Last Cal. Cal. Interval E4407B US39390582 Apr. 17, 2015 Agilent Instruments corporation Instruments corporation EMC01183 0 ESPI GTH-0118 Schwarzbeck VULB9163 SONOMA SHURPLE 310N N/A 980100 101604 351600 Apr. 17, 2015 Apr. 17, 2015 Apr. 20, 2015 VULB 9163-289 Apr. 20, 2015 186860 Apr. 17, 2015 N/A N/A 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year N/A Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 26 of 51 Report No.: R011508417I 5.4 Test Results Test Item Test Voltage Test Result Frequency Separation
:
: DC 3.7V
:
PASS Test Mode Temperature Humidity
: CH Low ~ CH High
: 24
: 55%RH Channel Low Mid High Low Mid High Frequency
(MHz) 2401 2441 2480 2401 2441 2480 Separation Read Value (kHz) 1005 1005 1005 1005 1005 1005 Limit
(kHz) 927.7 931.3 932.1 841.3 828.0 828.0 Modulation Mode BDR BDR BDR EDR EDR EDR Remark:
1. The limit of mode (EDR) is 2/3 of 20dB BW;
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 27 of 51 Report No.: R011508417I Test Mode: BDR---Low Test Mode: BDR---Mid Test Mode: BDR---High Test Mode: EDR---Low Test Mode: EDR---Mid Test Mode: EDR---High Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 28 of 51 Report No.: R011508417I 6. 20DB BANDWIDTH TEST 6.1 Measurement Procedure Using the following spectrum analyzer settings:
1. Span= approximately 2 to 3 times the 20dB bandwidth, centered on a hopping channel. 2. Set the RBW = 30 kHz. 3. Set the VBW = 100 kHz. 4. Sweep time = auto couple. 5. Detector function = peak. 6. Trace mode = max hold. 7. Allow trace to fully stabilize. 6.2 Test SET-UP EUT Spectrum analyzer 6.3 Test Equipment Same as the equipment listed in 5.3. 6.4 Test Results Test Item Test Voltage Test Result
:
20dB BW
: DC 3.7V
:
PASS Test Mode Temperature Humidity
: CH Low ~ CH High
: 24
: 55%RH Channel Low Mid High Low Mid High Frequency
(MHz) 2401 2441 2480 2401 2441 2480 20dB Down BW(kHz) Modulation Mode 927.7 931.3 932.1 1262.0 1242.0 1242.0 BDR BDR BDR EDR EDR EDR Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 29 of 51 Report No.: R011508417I Test Mode: BDR---Low Test Mode: BDR---Mid Test Mode: BDR---High Test Mode: EDR---Low Test Mode: EDR---Mid Test Mode: EDR---High Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 30 of 51 Report No.: R011508417I 7. QUANTITY OF HOPPING CHANNEL TEST 7.1 Measurement Procedure The EUT must have its hopping function enabled. Using the following spectrum analyzer setting:
1. Span= the frequency band of operation 2. Set the RBW = 1 MHz. 3. Set the VBW = 1 MHz. 4. Sweep time = auto couple. 5. Detector function = peak. 6. Trace mode = max hold. 7. Allow trace to fully stabilize. 7.2 Test SET-UP EUT Spectrum analyzer 7.3 Test Equipment Same as the equipment listed in 5.3. 7.4 Test Results Test Item
: Number of Hopping Test Mode
: CH Low ~ CH High Test Voltage Test Result Frequency
: DC 3.7V
:
PASS Temperature Humidity
: 24
: 55%RH Hopping Channel Frequency Range 2402-2480 Quantity of Hopping Channel 79 Quantity of Hopping Channel 15 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 31 of 51 Report No.: R011508417I Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 32 of 51 Report No.: R011508417I 8. DWELL TIME TEST 8.1 Measurement Procedure The EUT must have its hopping function enabled. Use the following spectrum analyzer settings:
1. Span= zero span, centered on a hopping channel 2. Set the RBW = 1 MHz. 3. Set the VBW = 1 MHz. 4. Sweep time = as necessary to capture the entire dwell time per hopping channel. 5. Detector function = peak. 6. Trace mode = max hold. 7. Allow trace to fully stabilize. 8.2 Test SET-UP EUT Spectrum analyzer 8.3 Test Equipment Same as the equipment listed in 5.3. 8.4 Test Results Test Item Test Voltage Test Result Time of Occupancy
:
: DC 3.7V
:
PASS Test Mode Temperature Humidity
: CH Low ~ CH High
: 24
: 55%RH Package Type Pulse width
(ms) Time slot length(ms) DH1 DH3 DH5 0.362 1.625 2.858 time slot length *1600/2 /79 * 31.6 time slot length *1600/4 /79 * 31.6 time slot length *1600/6 /79 * 31.6 Dwell time
(ms) 115.84 260.00 304.85 Limit (s) 0.4 0.4 0.4 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 33 of 51 Report No.: R011508417I DH1 DH3 DH5
/
/
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 34 of 51 Report No.: R011508417I 9. MAX IMUM PEAK OUTPUT POWER TEST 9.1 Measurement Procedure a. Check the calibration of the measuring instrument(SA) using either an internal calibrator or a known signal from an external generator. b. Turn on the EUT and connect it to measurement instrument. Then set it to any one convenient frequency within its operating range. Set a reference level on the measuring instrument equal to the highest peak value. c. The center frequency of the spectrum analyzer is set to the fundamental frequency and using proper RBW and VBW setting. d. Measure the captured power within the band and recording the plot. e. Repeat above procedures until all frequencies required were complete. Using the following spectrum analyzer settings:
1. Span= approximately 5 times the 20dB bandwidth, centered on a hopping channel 2. Set the RBW = 3 MHz. 3. Set the VBW = 3 MHz. 4. Sweep time = auto couple. 5. Detector function = peak. 6. Trace mode = max hold. 7. Allow trace to fully stabilize. 9.2 Test SET-UP EUT Spectrum analyzer 9.3 Test Equipment Same as the equipment listed in 5.3. Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 35 of 51 Report No.: R011508417I 9.4 Test Results Test Item Test Voltage Test Result
: Max. peak output power Test Mode
: DC 3.7V
:
Temperature Humidity PASS
: CH Low ~ CH High
: 24
: 55%RH Channel Frequency
(MHz) 2402 2441 2480 2402 2441 2480 Peak Power output(mW) Peak Power output(dBm) Peak Power Limit(mW) Results Modulation 1.588 1.660 1.826 1.546 1.407 1.512 2.009 2.202 2.615 1.891 1.483 1.795 1000 1000 1000 125 125 125 PASS PASS PASS PASS PASS PASS BDR BDR BDR EDR EDR EDR Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 36 of 51 Report No.: R011508417I Test Mode: BDR---Low Test Mode: BDR---Mid Test Mode: BDR---High Test Mode: EDR---Low Test Mode: EDR---Mid Test Mode: EDR---High Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 37 of 51 Report No.: R011508417I 10. BAND EDGE TEST 10.1 Measurement Procedure A) Conducted Emission method:
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal from an external generator. 2. Position the EUT without connection to measurement instrument. Put it on the Rotated table and turn on the EUT and make it operate in transmitting mode. Then set it to low Channel and High Channel within its operating range, and make sure the instrument is operated in its linear range. 3. Set both RBW and VBW of spectrum analyzer to 100kHz with a convenient frequency span including 100kHz bandwidth from band edge, 4. Measurement the highest amplitude appearing on spectral display and set it as a reference level. Plot the graph with marking the highest point and edge frequency. 5. Report above procedures until all measured frequencies were complete. B) Radiated Emission method:
The EUT is placed on a turn table which is 1.5 meter high above the ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The antenna can be moved up and down from 1 to 4 meters to find out the maximum emission level. Rotated the EUT through three orthogonal axes to determine the maximum emissions, both horizontal and vertical polarization of the antenna are set on test. The EUT is tested in 9*6*6 Chamber. for Radiated emissions restricted band RBW= 1 MHz, VBW= 3 MHz. 10.2 Test SET-UP EUT Spectrum analyzer Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 38 of 51 Report No.: R011508417I 10.3 Test Equipment Same as the equipment listed in 5.3. 10.4 Test Results Pass. Please refer the following data. Test Item Test Voltage Test Result
: Band eadge
: DC 3.7V
:
PASS Test Mode Temperature Humidity
: CH Low ~ CH High
: 24
: 55%RH For Hopping Mode:
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 39 of 51 Report No.: R011508417I Test Mode: BDR Test Mode: BDR Test Mode: EDR Test Mode: EDR Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 40 of 51 Report No.: R011508417I Test Item Test Voltage Test Result
: Band eadge
: DC 3.7V
:
PASS Test Mode Temperature Humidity
: CH Low ~ CH High
: 24
: 55%RH For Non-Hopping Mode:
1. Conducted Test Frequency Peak Power Output(dBm)
(MHz)
<2400
>2483.5 1.617 1.187 2.174 1.748 2. Radiated emission Test Frequency
(MHz)
<2400
>2483.5 Antenna polarization
(H/V) V V V V Emission read Value(dBm) Result of Band edge(dBc) Band edge Limit(dBc) Modulation
-37.074
-28.346
-51.842
-49.868 38.691 29.533 54.016 51.616
>20dBc
>20dBc
>20dBc
>20dBc BDR EDR BDR EDR Emission
(dBuV/m) Band edge Limit
(dBuV/m) Modulation PK 54.26 51.55 53.69 50.87 AV 38.25 35.36 37.92 34.60 PK 74.00 74.00 74.00 74.00 AV 54.00 54.00 54.00 54.00 BDR EDR BDR EDR Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 41 of 51 Report No.: R011508417I Test Mode: BDR Test Mode: BDR Test Mode: EDR Test Mode: EDR Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 42 of 51 Report No.: R011508417I 11. ANTENNA APPLICATION 11.1 Antenna requirement The EUTS antenna is met the requirement of FCC part 15C section 15.203 and 15.247. FCC part 15C section 15.247 requirements:
Systems operating in the 2402-2480MHz band that are used exclusively for fixed, point-to-point operations may employ transmitting antennas with directional gain greater than 6dBi provided the maximum peak output power of the intentional radiator is reduced by 1dB for every 3dB that the directional gain of the antenna exceeds 6dBi. 11.2 Result The EUTs antenna used a PCB Antenna, The antennas gain is 1.9dBi and meets the requirement. Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 43 of 51 Report No.: R011508417I 12. PHOTOGRAPH 12.1 Photo of Power Line Conducted Emission Measurement 12.2 Photo of Radiation Emission Test Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 44 of 51 Report No.: R011508417I Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 45 of 51 Report No.: R011508417I APPENDIX I (EXTERNAL PHOTOS) Figure 1 The EUT-Overall View Figure 2 The EUT-Top View Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 46 of 51 Report No.: R011508417I Figure 3 The EUT-Bottom View Figure 4 The EUT-Front View Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 47 of 51 Report No.: R011508417I Figure 5 The EUT-Back View Figure 6 The EUT-Right View Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 48 of 51 Report No.: R011508417I Figure 7 The EUT-Left View Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 49 of 51 Report No.: R011508417I APPENDIX (INTERNAL PHOTOS) Figure 8 The EUT-Inside View Figure 9 The EUT-Inside View Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 50 of 51 Report No.: R011508417I Figure 10 PCB of the EUT-Front View Figure 11 PCB of the EUT-Back View Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2AFHW-ITSB352 Page 51 of 51 Report No.: R011508417I Figure 12 PCB of the EUT-Front View Figure 13 PCB of the EUT-Back View Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066544 Fax:(86)755-26014772 www.anbotek.com
1 | Test Setup photos | Test Setup Photos | 425.94 KiB |
1 Photo of Power Line Conducted Emission Measurement 2 Photo of Radiation Emission Test
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2015-09-24 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2015-09-24
|
||||
1 | Applicant's complete, legal business name |
INNOVATIVE TECHNOLOGY ELECTRONICS LLC
|
||||
1 | FCC Registration Number (FRN) |
0024780371
|
||||
1 | Physical Address |
1 CHANNEL DRIVE
|
||||
1 |
PORT WASHINGTON, NY
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@siemic.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AFHW
|
||||
1 | Equipment Product Code |
ITSB352
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
G**** M****
|
||||
1 | Title |
Supply Chain Director
|
||||
1 | Telephone Number |
1-516********
|
||||
1 | Fax Number |
1-516********
|
||||
1 |
s******@ithomeproducts.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Bluetooth Boombox with Rubberized Finish | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is the maximum conducted output power. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen Anbotek Compliance Laboratory Limited
|
||||
1 | Name |
D****** z********
|
||||
1 | Telephone Number |
86-75********
|
||||
1 |
D******@anbotek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0018300 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC