Intellion AG Schuppisstrasse 10 9016 St. Gallen Switzerland T 0041-71-280 81 81 E info@intellion.com www intellion.com User Manual LeanOrder detectionShelf Version Nr.:
Date:
Author:
2.0 03.05.2018 Raphael Carigiet, Intellion AG Intellion AG 2018 Seite 1/8 Table of Contents 1. LeanOrder detectionShelf ............................................................................................ 3 1.1 Identify the LeanOrder detectionShelf ...................................................................... 3 1.2 Set-up for the LeanOrder detectionShelf .................................................................. 4 1.3 Use cases for different users .................................................................................... 5 1.4 Scanning modes of the LeanOrder detectionShelf ................................................... 6 2. Compliance information ............................................................................................... 7 2.1 USA Notification ....................................................................................................... 7 2.2 Canada Certification ................................................................................................ 8 Intellion AG 2018; User Manual detection Shelf Seite 2/8 1. LeanOrder detectionShelf The LeanOrder detectionShelf is used in different types of racks to identify empty bins and trig-
ger a replenishment message for the articles linked to these bins. 1.1 A LeanOrder detectionShelf (see Figure 1) can be identified by a unique barcode label at the front of the LeanOrder detectionShelf (see Figure 2). Identify the LeanOrder detectionShelf Figure 1: LeanOrder detectionShelf Figure 2: LeanOrder detectionShelf and the barcode label Intellion AG 2018; User Manual detection Shelf Seite 3/8 1.2 Set-up for the LeanOrder detectionShelf The LeanOrder detectionShelf has a battery compartment for nine AA lithium batteries. The batteries can be inserted after the battery cover has been removed using a screwdriver for the two screws (Figure 3).
+ positive pole
- negative pole LED Figure 3: LeanOrder detectionShelf and the barcode label The AA lithium batteries (3.6V / 2.4Ah) have to be inserted correctly, see Figure 3. The polari-
zation of the battery compartment is for each battery the same. Intellion AG 2018; User Manual detection Shelf Seite 4/8 1.3 Use cases for different users The LeanOrder detectionShelf is used to detect bins with passive UHF RFID labels (see Figure 4; two black bins with a UHF RFID label). There are two users for the LeanOrder detectionShelf:
The manufacturing operator, working in the manufacturing facility where the detection-
Shelf is integrated in racks, has to place empty bins on top of the LeanOrder detection-
Shelf in order to enable the detection and the transmission of a replenishment infor-
mation to the central server. Empty bins are read using the automatic scanning mode
(see explanation in chapter 1.4);
A replenishment operator clears the LeanOrder detectionShelf by taking all accumu-
lated empty bins off the detectionShelf. In order to ensure that all empty bins are read by the detectionShelf using RFID, the replenishment operator can perform the manual scanning mode (see explanation in chapter 1.4). Figure 4: LeanOrder detectionShelf with two RFID-labeled empty bins Intellion AG 2018; User Manual detection Shelf Seite 5/8 1.4 Scanning modes of the LeanOrder detectionShelf The detection Shelf has two scanning modes to detect empty bins:
Automatic scanning mode Manual scanning mode The automatic scanning mode is the default-scanning mode. In this mode, the LeanOrder detectionShelf scans every predefined time period (e.g. all four hours) sequentially over all an-
tennas integrated in the detectionShelf. After an automatic scan round, the detection Shelf sends automatically the RFID ePC codes of all detected empty bins to a central LeanOrder Controller in the manufacturing facility. The manual scanning mode is activated using a magnet that triggers a hall sensor within the LeanOrder detectionShelf. The magnet has to be placed on top of the detection Shelf directly above the LED (see Figure 5). During the manual scan, the LED next to the barcode will flash. After an automatic scan round, the detection Shelf sends automatically the RFID ePC codes of all detected empty bins to a central LeanOrder Controller in the manufacturing facility. Figure 5: A magnet on the LeanOrder detectionShelf to trigger the manual scanning mode Intellion AG 2018; User Manual detection Shelf Seite 6/8 2. Compliance information Model:
detectionShelf Region/Country Organization Marking USA:
Canada:
FCC 2ANAA-LODSHELF01 Industry Canada 23043-LODSHELF01 2.1 USA Notification This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Class B: (Section 15.105) FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the follow-
ing measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/ TV technician for help. CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. RF exposure warning This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provide with antenna installation in-
structions and transmitter operating conditions for satisfying RF exposure compliance. Intellion AG 2018; User Manual detection Shelf Seite 7/8 2.2 Canada Certification This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the Following two conditions :
(1) this device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage Radio Frequency (RF) Exposure Information The radiated output power of the Wireless Device is below the Industry Canada (IC) radio fre-
quency exposure limits. The Wireless Device should be used in such a manner such that the potential for human contact during normal operation is minimized. This device has also been evaluated and shown compliant with the IC RF Exposure limits under mobile exposure conditions. (antennas are greater than 20cm from a person's body). Informations concernant l'exposition aux frquences radio (RF) La puissance de sortie mise par lappareil de sans fil est infrieure la limite d'exposition aux frquences radio d'Industry Canada (IC). Utilisez lappareil de sans fil de faon minimiser les contacts humains lors du fonctionnement normal. Ce priphrique a galement t valu et dmontr conforme aux limites d'exposition aux RF d'IC dans des conditions d'exposition des appareils mobiles (antennes sont suprieures 20 cm partir du corps d'une personne). Intellion AG 2018; User Manual detection Shelf Seite 8/8