C3I-W WIRELESS MODEM INSTALLATION MANUAL THE C3IW IS A WIRELESS VERSION OF THE C3I FAMILY OF PRODUCTS WHICH IS DESIGNED TO REMOTELY READ ELECTRICAL, GAS, AND WATER METERS AS WELL AS PERFORM LOAD MANAGEMENT FUNCTIONS. THE C3IW USES TELEMETRY FREQUENCIES IN THE VHF BAND TO ACCOMPLISH THIS. THE C3IW CAN READ UP TO 4 METERS AND CONTROL UP TO 3 APLLIANCES. Load Management WHEN AN ELECTRICAL PEAK IS DETECTED AT A SUBSTATION, A DESIGNATED CODE IS SENT OUT TO A GROUP OF C3I GATEWAYS. IN TURN, THE GATEWAYS WILL SHUT OFF A DESIRED ELECTRICAL APPLIANCE FOR A SHORT PERIOD OF TIME VIA THE ONBOARD RELAY CONTROL CIRCUIT. Meter Reading THE C3I GATEWAY CAN ALSO READ DATA FROM ELECTRICAL, WATER, GAS, OR ANY OTHER TYPE OF METERING WITH CORRECT INTERFACING. WHEN METERS ARE TO BE READ, THE SPECIFIC GATEWAY WILL BE POLLED BY THE BASE UNIT, REQUESTING ITS METER READING DATA. THE GATEWAY WILL THEN SEND ITS DATA BACK IN THE FORM OF DATA PACKET. THE C3IW COMES INSTALLED IN WEATHERPROOF ENCLOSURE. T1 BAR CONNECTOR CONTAINS ALL INPUTS AND RELAY OUTPUTS ALONG WITH DC INPUT. ALL POSITIONS ARE CLEARLY MARKED FOR EASY INSTALLATION AS SHOWN BELOW:
R
1 R E D O C N E G
1 R E D O C N E B
1 R E D O C N E R
2 R E D O C N E G
2 R E D O C N E B
2 R E D O C N E T 2 S M E T S Y S Y G R E N E T E N R E T N I 4 0 0 2 T H G R Y P O C I Y A W E T A G S S E L E R I W I 3 C S M E T S Y S Y G R E N E T E N R E T N I 1 2 V RX A GND PT T MX 42 9A IC3 Q U2 Q U3 Q U5 IC8 S TA T US P 0 1 E L B A C R-
1 N O C I G N M M A R G O R P 1 T 1 IC1 K 1 K 2 K 3
C D V 2 1
C D V 2 1
1 T U P N I
1 T U P N I
2 T U P N I
2 T U P N I
3 T U P N I
3 T U P N I
4 T U P N I
4 T U P N I M O C 1 R O
N 1 R C
N 1 R M O C 2 R O
N 2 R C
N 2 R M O C 3 R O
N 3 R C
N 3 R 12 VDC + : CONNECTS TO POWER SOURCE 10 TO 25 VOLTS 12 VDC - : POWER SOURCE GROUND INPUT 1 + : TO METER 1 PULSE ENCODER INPUT 1 - : TO METER 1 PULSE ENCODER INPUT 2 + : TO METER 2 PULSE ENCODER INPUT 2 - : TO METER 2 PULSE ENCODER INPUT 3 + : TO METER 3 PULSE ENCODER INPUT 3 - : TO METER 3 PULSE ENCODER INPUT 4 + : TO METER 4 PULSE ENCODER INPUT 4 - : TO METER 4 PULSE ENCODER R1 COM : RELAY 1 COMMON R1 N/O : RELAY 1 NORMALLY OPEN R1 N/C : RELAY 1 NORMALLY CLOSED R2 COM : RELAY 2 COMMON R2 N/O : RELAY 2 NORMALLY OPEN R2 N/C : RELAY 2 NORMALLY CLOSED R3 COM : RELAY 3 COMMON R3 N/O : RELAY 3 NORMALLY OPEN R3 N/C : RELAY 3 NORMALLY CLOSED WARNING: This device may only be installed and serviced by authorized utility personnel. Access to consumers should be denied with an appropriate utility lock or seal. NOTICE: This equipment complies with the FCC RF Exposure Limits. A minimum of 20 centimeters (8 inches) separation between the device and the user and all other persons should be maintained. This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. SPECIFICATIONS FREQUENCY COVERAGE 154.390, 154.45625, 154.46375, 154.47125, 154.47875, 173.20375, 173.21, 173.2375, 173.2625, 173.2875, 173.3125, 173.3375, 173.3625, 173.39, 173.39625 INPUT VOLTAGE MIN 10V MAX 25V MAX CURRENT DRAW 300MA PULSE INPUT VOLTAGE MIN 2.5V MAX 20V APPROXIMATE CPU EPROM WRITE LIFE 10 YEARS RECEIVER IF FREQUENCY SINGLE CONVERSION 455KHZ SENSITIVITY 12DB SINAD @ 1.4UV TRANSMITTER OUTPUT POWER 90MW DEVIATION
+- 2.5KC MAX