Installation Guide INVIXIUM ACCESS Table of Contents Glossary and Definitions ..............................................................................................................................................................3 Earth Ground .............................................................................................................................................................................4 Device Handling and Cleaning ......................................................................................................................................................5 IXM INSTALL KIT Contents.........................................................................................................................................................6 IXM MYCRO ...........................................................................................................................................................................7 IXM SENSE .............................................................................................................................................................................9 IXM TOUCH ........................................................................................................................................................................... 11 I/O Cable: Top Connector Pin Out ............................................................................................................................................... 13 I/O Cable: Bottom Connector Pin Out .......................................................................................................................................... 14 Hardware Tools Required For Installation .................................................................................................................................... 15 Hardware Installation Steps ....................................................................................................................................................... 16 Connections for Power ............................................................................................................................................................... 20 Connections for Communication ................................................................................................................................................. 22 Connections for Operation ......................................................................................................................................................... 26 Electrical Specifications ............................................................................................................................................................. 28 Software Installation System Requirements ................................................................................................................................. 29 Software Installation Steps ........................................................................................................................................................ 30 Notices ................................................................................................................................................................................... 32 Support ................................................................................................................................................................................... 36 INVIXIUM Copyright 2016 2 invixiumaccess Glossary ACP COM DAC DOS EGND ESD GND IXM LED NC NO OTG RLY RX SGND SPI SPO TX USB WDATA WGND VDC VIN+
VIN-
INVIXIUM Copyright 2016 Access Control Panel Common Door Access Control Door Open Schedule Earth Ground Electrostatic Discharge Ground INVIXIUM Light Emitting Diode Normally Closed Normally Open On-the-Go Relay Receive Signal Ground Specific Purpose Input Specific Purpose Output Transmit Universal Serial Bus Wiegand Data Wiegand Ground Volts Direct Current Power Positive (12-24 VDC) Power Return Metal Mounting Plate Wired Back Cover Temporary Back Cover 3 invixiumaccess Earth Ground For protection against ESD, which may cause damage or malfunction to the IXM device, Invixium recommends the use of the ground connections between each IXM device and a high quality Earth Ground available at the install site. Please note that installation of any IXM device should be performed by licensed electricians. An Earth Ground wire with lug is provided in the IXM INSTALL KIT. The lug of the Earth Ground wire should be fastened with a screw to the front of the mounting plate. The other end of the Earth Ground wire should be connected to the high quality Earth Ground connection on site. When the IXM device is installed onto the mounting plate, this Earth Ground lug will make direct contact with the Metal Back plate of the IXM device, thus allowing for proper grounding. Please refer to page 15 for step-by-step instructions for mounting plate, device and Earth Ground wire installation. Earth Ground Earth Ground Wire INVIXIUM Copyright 2016 4 invixiumaccess Device Handling Do's Handle with care, ensure not to drop or step on the device. Perform occassional cleaning to eliminate a build-up of dust, dirt, oil and residual grime. Device Handling Don'ts Do not install in areas with direct sunlight, high levels of humidity, extreme dust or flammable vapours. Do not allow magnetic objects to come in close contact to any device. Do not install near any heating elements or equipment. Do not attempt to open or disassemble the device, as this will void the product warranty. Do not deploy for any use other than its intended purpose. Do not insert anything other than the correct fitting USB plug into the USB port, located at the bottom of the device. Device Cleaning The component that will require most frequent cleaning is the sensor, as it experiences the most contact. The cleaning should be performed with care and attention, as improper cleaning may damage the sensor or surrounding components. Follow the steps below for proper sensor cleaning procedure:
1. 2. 3. Lightly moisten a new cotton swab or lint free polishing cloth with water or isopropyl alcohol. Gently wipe the surface of the sensor with the moistened cotton swab or cloth. Finish the wiping the sensor again with a dry cotton swab or cloth. Do not use harsh or abrasive chemicals to clean the surface of the sensor, as this may cause permanent damage to the device. Do not use sandpaper, steel wool, scouring pads, chlorine, ammonia, bleach, or any inappropriate products for cleaning. WARNING INVIXIUM Copyright 2016 5 invixiumaccess The IXM Install Kit includes:
IXM INSTALL KIT Micro USB-On-the-Go Cable D O L P HIN DOLPHIN D OLP HIN HIN P L O D DOLPHIN D OLPHIN DOLPHIN DOLPHIN DOLPHIN D O L P HIN OLPHIN D DOLPHIN D OLP HIN DOLPHIN Dolphin Crimps
(qty 24) Lithium Battery
(IXM TOUCH only) INVIXIUM INVIXIUM Micro USB Extension Cable (4 ft/1.2m) Wired Back Cover Earth Ground Wire Ferrrite Core Hex Key Metal Mounting Plate Metal Mounting Plate Screw
(qty 1) Wall Mounting Screws USB Flash Drive
(qty 4) INVIXIUM Copyright 2016 6 INVIXIUM ACCESS invixiumaccess IXM MYCRO Rugged Front Shell Multi-color LEDs Sensor More than IP65 Surge Protection as per EN55024 Industrial Grade Connectors Solid Metal Back Plate 7 48 38.5 41.70 4.20 8 6 1 2 6 1 1
. 2 8 0 1 1 Front View Side View 30 Front View 46.3 8.10 i w e V e d S i Angled Front View m m n i s n o i s n e m D i e z i S l a u t c A n i e g a p s i h t g n i t n i r p s d n e m m o c e r I M U X V N I I l l a u t c A e t a P g n i t n u o M
&
t c u d o r P O R C Y M M X I 8 IXM SENSE Rugged Front Shell More than IP65 Multispectral Fingerprint Imaging Sensor Surge Protection as per EN55024 Multi-color LEDs Lumidigm Sensor Industrial Grade Connectors Solid Metal Back Plate 9 49 46.08 45.20 5.40 7
. 9 9 1 9
. 4 9 1 1
. 2 8 0 1 1 Front View Side View Front View 30 51.85 9 i w e V e d S i Angled Front View m m n i s n o i s n e m D i e z i S l a u t c A n i e g a p s i h t g n i t n i r p s d n e m m o c e r I M U X V N I l l a u t c A e t a P g n i t n u o M
&
t c u d o r P E S N E S M X I 10 IXM TOUCH Super Strong Protective Glass Multi-color LEDs Sensor Optically Bonded Capacitive Touch Screen More than IP65 Surge Protection as per EN55024 Rugged Front Shell Industrial Grade Connectors Solid Metal Back Plate 11 49 46.08 45.20 5.40 7
. 9 9 1 9
. 4 9 1 1
. 2 8 0 1 1 Front View Side View Front View 30 51.85 9 i w e V e d S i Angled Front View m m n i s n o i s n e m D i e z i S l a u t c A n i e g a p s i h t g n i t n i r p s d n e m m o c e r I M U X V N I l l a u t c A e t a P g n i t n u o M
&
t c u d o r P H C U O T M X I 12 I/O Cable: Top Connector Pin Out Wired Back Cover Front View Back View RLY_NO RLY_COM RLY_NC SPO_1 SPO_2 SPO_3 SPO_GND ACP_LED1 ACP_LED2 ACP_LED_GND SPI_GND SPI_3 SPI_2 SPI_1 DAC_IN1 DAC_IN2 DAC_IN3 DAC_GND NC DAC_OUT Wire Color Wire Color Label RLY_NC RLY_COM RLY_NO ACP_LED1 ACP_LED2 Pin Application 1 Relay Normally Closed 3 Relay Common 5 Relay Normally Open 7 Access Control Panel LED 1 Feedback Access Control Panel LED 2 Feedback 9 Ground for Access Control Panel LED Feedback ACP_LED_GND 11 13 Door Access Control Input 1 15 Door Access Control Input 2 Door Access Control Input 3 17 19 Ground for Door Access Control Inputs DAC_IN1 DAC_IN2 DAC_IN3 DAC_GND INVIXIUM Copyright 2016 Label SPO_1 SPO_2 SPO_3 Application Specific Purpose Output Line 1 Specific Purpose Output Line 2 Specific Purpose Output Line 3 Ground for Specific Purpose Outputs SPO_GND Specific Purpose Input Line 1 Specific Purpose Input Line 2 Specific Purpose Input Line 3 Ground for Specific Purpose Inputs Door Access Control Output Reserved for Future (No Connect) SPI_1 SPI_2 SPI_3 SPI_GND DAC_OUT N/C Pin 2 4 6 8 10 12 14 16 18 20 13 invixiumaccess I/O Cable: Bottom Connector Pin Out Wired Back Cover Front View Wire Color Back View Application Power (+12-24 VDC) Power Ground Earth Ground RS-485 Terminated (Optional)*
EGND VIN-
VIN+
RS232_RX RS232_TX SGND RS-485+ (B) RS-485- (A) Wire Color Label VIN+
VIN-
EGND RS-485_T Pin 1 3 5 7 Ethernet or PoE TCP/IP 9,11,13, 15,17,19
*This pin is optional and should be used in place of the RS-485+ terminal if 120 termination is required. PoE only available for IXM SENSE and IXM TOUCH NOTE INVIXIUM Copyright 2016 RS-485_T TCP/IP WGND WDATA_OUT1 WDATA_OUT0 WDATA_IN1 WDATA_IN0 RJ45 Receptacle Application RS-232 Data Receive RS-232 Data Transmit Signal Ground RS-485 Non-Inverting Line RS-485 Inverting Line Wiegand Data Input Line 0 Wiegand Data Input Line 1 Wiegand Data Output Line 0 Wiegand Data Output Line 1 Ground for Wiegand Label RS-232_RX RS-232_TX SGND RS-485+ (B) RS-485- (A) WDATA_IN0 WDATA_IN1 WDATA_OUT0 WDATA_OUT1 WGND Pin 2 4 6 8 10 12 14 16 18 20 14 invixiumaccess Hardware Tools Required For Installation Battery powered Screwdriver Hammer*
Power Drill*
Measuring Tape Installation of any IXM device should be performed by licensed electricians. Ratchet-style Crimping tool Pencil Manual Screwdriver NOTE INVIXIUM Copyright 2016
*Depending on the mounting surface, the Power Drill and Hammer may not be required. invixiumaccess 1 Ensure Power is Off This protects the device being installed. 2 IXM Install Kit Remove the following items from the kit:
ON O F F 3 Mark the Screws Holes INVIXIUM recommends the use of the 4 circular holes for mounting. Refer to diagrams on page 8, 10 or 12 for actual dimensions. Ideal mounting height is 120 -
140 cm from the ground to the top of the device. But also be sure to align the device in case of multiple installations. INVIXIUM Copyright 2016 D O L P HIN DOLPHIN D OLP HIN HIN P L O D DOLPHIN D OLPHIN DOLPHIN DOLPHIN DOLPHIN D O L P HIN OLPHIN D DOLPHIN D OLP HIN DOLPHIN 4 Drill Holes If required, drill holes where marked and install the appropriate wall anchors (not included) using the hammer. s m c 0 4 1
-
0 2 1 16 invixiumaccess 5 Get Wires Get access to the installation wires either from behind the wall or from the wiring conduit. Feed wires through the square hole of the mounting plate. 6 Insert Screws Align the holes of the mounting plate with the wall anchors and attach the mounting plate with the screws provided in the IXM Install Kit. Invixium recommends the use of an electric or battery-powered screwdriver for this step. 7 Identify the Connections:
1 Power & Grounding 2 Communications 3 Operations DC Power VIN+
VIN-
EGND RS-485 SGND RS-485+
RS-485-
ACP ACP_LED1 ACP_LED2 ACP_LED_GND WDATA_OUT0 WDATA_OUT1 WGND INVIXIUM Copyright 2016 OR OR OR PoE RJ-45 Receptacle EGND Ethernet RJ-45 Receptacle DAC RLY_NC RLY_COM RLY_NO DAC_IN1 DAC_IN2 DAC_OUT OR RS-232 RS-232_RX RS-232_TX SGND USB OR Refer to pages 20 & 21 for Power connections, pages 22-25 for Network or Serial Communication connections and pages 26 & 27 for Operation connections. 17 invixiumaccess 8A Make the Connections Connect the required wires using the Dolphin crimps provided in the IXM Install Kit (or any similar crimps) and a ratchet style crimping tool. Insert the two wires (no stripping required) into the open end of the crimp and then using the crimping tool, clamp down on the middle of the crimp. N I H P L O D Earth Ground Wire Lug 8B Connect Earth Ground Connect the lug of the Earth Ground wire directly to the front of the mounting plate using one of the Wall mounting screws. Ensure that the lug is secured tightly as to make the necessary contact between the device and the mounting plate. Connect the other end of the Earth Ground wire to the Earth Ground connection of the install site with a crimp. Ensure all required connections are made to each device in the setup prior to turning on the power. Checklist:
Connections for Power & Grounds (DC or PoE) Connections for Communications (Ethernet, RS-485 or RS-232) Connections for Operation (ACP or DAC) INVIXIUM Copyright 2016 18 invixiumaccess 9 Attach the Device Take the IXM device and unscrew the Temporary Back Cover, keeping the screws handy. Connect the Wired Back Cover to the back of the device by lining up the connectors. Secure the Wired Back Cover with the same screws. Next, hang the IXM device onto the mounting plate as shown in the series of diagrams below. 10 Secure the Device Finally, secure the device on the bottom to the mounting plate with the Metal Mounting Plate screw provided in the IXM Install Kit. 1 2 3 INVIXIUM Copyright 2016 INVIXIUM 19 invixiumaccess Connections for Power UPS DC Power Supply IXM MYCRO VIN+
VIN-
EGND INVIXIUM recommends:
12-24 VDC regulated power supply Dedicated Power Supply for each IXM device (minimum 1 A) Use of a battery back-up or UPS with built-in surge protection If sharing power supplies, ensure that each device is supplied with minimum 1 A per device
(ie. Powering two devices will require an supply with output current of 2 A) Product Warranty is void if improper power (under or over) is supplied to the device. WARNING INVIXIUM Copyright 2016 Bottom Connector Power VIN+
VIN-
EGND
(1)
(3)
(5) 20 invixiumaccess Connections for Power Over Ethernet (PoE) Only available on IXM SENSE and IXM TOUCH IXM SENSE INVIXIUM recommends:
A centralized Power Sourcing Equipment (PSE) for full PoE deployments (not included) Use of a battery back-up or UPS with built-in surge protection Both IEEE 802.3af power transmission modes (A and B) are supported. NOTE INVIXIUM Copyright 2016 IXM TOUCH Bottom Connector PoE
(9) TX+
(11) TX-
RJ45_PIN4 (13) RX+
(15) RX-
(17) RJ45_PIN7 (19) 21 invixiumaccess Ethernet and Wi-Fi Communication Ethernet:
Switch/Router required CAT 5 cabling or better WiFi:
802.11b/g/n protocol Wireless router to LAN/WAN WEP, WPA and WPA2 encryptions supported DHCP enabled by default IXM WEB Router connected to LAN/WAN INVIXIUM Copyright 2016 22 IXM MYCRO IXM SENSE IXM TOUCH invixiumaccess RS-485 Network Communication INVIXIUM recommends:
Daisy chain configuration Maximum 31 devices in the network Maximum cable length of 1200 m (4000 ft.) at 9600 bps baud rate Both RS-485 converter and the last device in the chain should be terminated (not included, refer to NOTE below for correct Resistor values) Connect the IXM device to PC via RS-485-to-Serial (RS-232 or USB) Converter IXM WEB RS-485 to USB Converter R R IXM TOUCH IXM SENSE IXM MYCRO R = 120 ohms for Standard RS-485 Cabling R = 100 ohms for CAT5/6 Cabling NOTE INVIXIUM Copyright 2016 Bottom Connector RS-485 SGND RS-485+
RS-485-
(6)
(8)
(10) 23 invixiumaccess Serial Communication 1 2 3 4 5 SG N D RS232_RX RS232_TX IXM WEB IXM TOUCH USB-to-Serial Converter RS-232:
Connect IXM device directly to the DB9 Serial port of the PC (if available) DB9 connectors and cables are not included INVIXIUM Copyright 2016 Bottom Connector RS-232 RS-232_RX (2) RS-232_TX (4) SGND
(6) 24 invixiumaccess USB Communication IXM SENSE Host PC Micro USB cable
(Provided in IXM Install Kit) USB:
Connect a Flash Drive via Micro USB OTG cable and perform functions like upgrading firmware and downloading transaction logs USB port can also be used to connect to a PC running IXM WEB via Micro USB cable Driver installation is required and will automatically initiate once the device is connected INVIXIUM Copyright 2016 25 invixiumaccess Access Control Panel Connections 3 3 IXM TOUCH IXM TOUCH ACP ACP_LED1 ACP_LED1 ACP_LED2 ACP_LED2 ACP_LED_GND ACP_LED_GND
(7)
(9)
(11) Top Connector LED ACP_LED1 ACP_LED2 ACP_LED_GND Bottom Connector Wiegand WDATA_OUT0 WDATA_OUT1 WGND
(16)
(18)
(20) WDATA_OUT0 WDATA_OUT0 WDATA_OUT1 WDATA_OUT1 WGND WGND ACP:
NOTE LED and Wiegand connections available for ACP operation INVIXIUM recommends the use of Wiegand Output Data 0, 1 and GND connection ACP_LED signals can be used if available on the Access Control Panel. IXM devices support up to 2 wires + GND for LED status. INVIXIUM Copyright 2016 26 invixiumaccess Door Access Control Connections IXM TOUCH IXM TOUCH RLY_NO RLY_NO RLY_COM RLY_COM DAC_IN1 DAC_IN1 DAC_OUT DAC_OUT Snubber Diode Snubber Diode Electric Door Strike strike
+-
+-
Door Strike Power Supply Door Strike Power Supply DAC_OUT DAC_GND DAC_IN2 DAC_IN2 Door Contact Door Contact Request to exit Request to exit
*Max Relay rating=1 Amp @ 30 VDC
* Max Relay rating-1 Amp @ 30 VDC DAC:
INVIXIUM recommends a separate power supply for Door Strike (not included) Snubber Diode required for Door Strike (not included) Example above shows use of RLY_NO, but RLY_NC may be used instead if required by the Door Strike Internal Relay rated upto max of 1 A @ 30 VDC, external relay required if Door Strike draws more than 1A For motion detector instead of Request-to-Exit-button, connect the following signals:
(1) DAC_OUT to the COM and (2) DAC_IN2 to the Relay NO of the motion detector INVIXIUM Copyright 2016 Top Connector DAC
(1) RLY_NC
(3) RLY_COM
(5) RLY_NO
(13) DAC_IN1
(15) DAC_IN2 DAC_OUT (18) 27 invixiumaccess Electrical Information Power Voltage (V) Current (A) Specific Purpose Inputs VIN_H (V) VIN_L (V) Pull-down Resistance () Wiegand Inputs VIN_H (V) VIN_L (V) Pull-up Resistance () Specific Purpose Outputs VOUT_H (V) VOUT_L (V) Wiegand Outputs VOUT_H (V) VOUT_L (V) Pull-down Resistance () Internal Relay Current Rating (A) Switching Power (R) Switching Voltage (V) INVIXIUM Copyright 2016 Min. Value Recommended Max. Value Additional Comments 9.6
-
4
-
-
2
-
-
4.2
-
4.5
-
-
-
-
-
12 1
-
-
10K
-
-
10K
-
-
-
-
4.7K
-
-
-
24
-
-
1
-
-
0.8
-
-
0.44
-
0.8
-
1 0.3 30 Watt 30 VA 110 125 INVIXIUM recommends using a regulated DC power supply Internal 10K pull-down resistor is present on SPI1, SPI2 and SPI3 lines Internal 10K pull-up is present on Wiegand input lines
@IOH = -24mA
@IOL = +24mA Wiegand Output is an open drain output. Internal 4.7K pull-up is present on these lines
@ 30 VDC
@ 125 VAC DC AC DC AC invixiumaccess Software Installation System Requirements To successfully install and run Invixium software, the system must meet the following minimum requirements:
PC Workstation:
1 GHz Intel Pentium 4 or equivalent
(INVIXIUM recommends 2.0 GHz or higher) 1 GB RAM (INVIXIUM recommends 2 GB RAM or higher) 50 MB Free Hard Disk Space for IXM WEB 850 MB Hard Disk for x86 systems or 2 GB Hard Disk for x64 systems for Microsoft.NET Version 4.0 500 MB Hard Disk Space for Microsoft.NET Version 2.0
(Windows XP & Windows 2003 R2) 1 GB Hard Disk (INVIXIUM recommends) for SQL Server 2008 Express Edition SP1 Available COM or USB port Ethernet Card (10/100 Mb Ethernet connections) Monitor capable of displaying at least 1024 x 786 high colour resolution One of the following Operating Systems:
Windows 8 and 7 both 32-Bit and 64-Bit versions Windows XP Service Pack 3 or higher Windows Server 2012 Windows 2008 R2 Windows 2008 Windows 2003 R2 One of the following Web Browsers (Client):
Internet Explorer version 8.0 or higher Google Chrome version 26.0 or higher Mozilla Firefox version 20.0 or higher Apple Safari version 5.1.7 or higher IXM WEB will install the following:
Microsoft.NET Framework (version 4.0) SQL Server 2008 Express Edition Service Pack 1 Microsoft Internet Information Services (version 7.5) Windows Installer (version 4.5) INVIXIUM Copyright 2016 NOTE 29 Windows Professional or Enterprise versions only invixiumaccess Software Installation Steps Step 1 Plug the USB drive (found in IXM INSTALL KIT) into an available port on PC. Step 2 Open the USB drive folder. Run IXMWEB.exe file. The IXM WEB Install Menu will initiate. Step 3 There are two installation options: INSTALL or ADVANCED. INVIXIUM recommends selecting INSTALL option for rapid installation. The ADVANCED process allows for:
entering a different install path entering a specific Port number checkbox for installing SQL Server database checkbox for installing Certificates A Windows dialog may pop up to provide a warning about installing from an unreliable source. Click Yes to proceed with the install. NOTE INVIXIUM Copyright 2016 30 invixiumaccess Step 4 During the installation process, the status of the install will be shown. Step 5 When the installation is complete, click EXIT. IXM WEB icon is now on the desktop. Step 6 Run IXM WEB to launch the application in the default web browser to setup the Database and Admin credentials. INVIXIUM Copyright 2016 31 FCC Information to Users (English) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. 2. This device may not cause harmful interference This device must accept any interference received, including interference that may cause undesired operation. Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/TV technician for help Informations de la FCC aux Utilisateurs (en Franais) Cet appareil est conforme la partie 15 des rgles de la FCC. Son fonctionnement est soumis aux deux conditions suivantes:
1. 2. Cet appareil ne doit pas provoquer d'interfrences nuisibles Cet appareil doit accepter toute interfrence reue, incluant toute interfrence pouvant causer un fonctionnement indsirable INVIXIUM Copyright 2016 32 invixiumaccess Notification Cet quipement a t test et s'est avr conforme aux limites pour un appareil numrique de Classe B, conformment la partie 15 des rgles de la FCC. Ces limites sont conues pour fournir une protection raisonnable contre les interfrences nuisibles dans une installation rsidentielle. Cet quipement gnre, utilise et peut mettre des frquences radio et, s'il n'est pas install et utilis conformment aux instructions, il peut causer des interfrences nuisibles pour les communications radio. Cependant, il n'existe aucune garantie que des interfrences ne se produiront pas dans une installation particulire. Si cet quipement provoque des interfrences nuisibles la rception radio ou de tlvision, ce qui peut tre dtermin en l'teignant et rallumant, l'utilisateur est encourag essayer de corriger l'interfrence par une ou plusieurs des mesures suivantes:
Rorienter ou dplacer l'antenne de reception Augmentez la distance entre l'quipement et le rcepteur Connecter l'quipement une sortie sur un circuit diffrent de celui sur lequel le rcepteur est branch Pour obtenir de laide, consulter le revendeur ou un technicien radio / TV expriment FCC RF Radiation Exposure Statement (English) This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed an operated with minimum distance of 20 cm between the radiator and your body. Industry Canada RF Radiation Exposure (English) This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Industrie Canada exposition aux radiations RF (en Franais) Cet quipement est conforme aux limites d'exposition aux rayonnements IC tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 20cm de distance entre la source de rayonnement et votre corps. INVIXIUM Copyright 2016 33 invixiumaccess CE Information to Users (English) All INVIXIUM devices have the CE mark for conformance with EMC Directive 89/336/EEC, and Low Voltage Safety Directive 73/23/EEC. Device with RFID components are compliant with R&TTE Directive 1999/5/EC, and are Class 1 Devices. Informations de la CE aux Utilisateurs (en Franais) Tous les dispositifs de INVIXIUM ont le marquage CE de conformit la directive CEM 89/336/CEE et basse tension de scurit Directive 73/23/CEE. Les appareils avec composants RFID sont conformes aux Directive R & TTE 1999/5/CE. et sont des appareils de classe 1. Industry Canada Information to Users (English) This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
1. 2. This device may not cause interference This device must accept any interference, including interference that may cause undesired operation of the device Industrie Canada Information pour les Utilisateurs (en Franais) Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes:
1. 2. Cet appareil ne doit pas provoquer d'interfrences Cet appareil doit accepter toute interfrence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil INVIXIUM Copyright 2016 34 invixiumaccess Warning to Users (English) Changes or modifications not expressly approved by INVIXIUM could void the user's authority to operate the equipment. Warning Avertissement aux Utilisateurs (en Franais) Les changements ou modifications non expressment approuvs par INVIXIUM pourraient annuler l'autorit de l'utilisateur utiliser l'quipement. Avertissement INVIXIUM Copyright 2016 35 invixiumaccess For Technical or Customer Support issues, please contact your Local Authorized Reseller. For all other inquiries, please contact us at experience@invixium.com For detailed information, please visit our website:
invixium access Enjoy the Experience. Some features may vary based on device models. Copyright 2016, INVIXIUM. All rights reserved. P/N XAD-00E-026-03G INSTALLATION GUIDE INGUIDE invixium.com 2016 Google Inc. All rights reserved. ChromeTM browser is a trademark of Google Inc. Firefox logo is a registered trademark of the Mozilla Foundation. Windows and Internet Explorer are trademarks of the Microsoft group of companies. Safari is a trademark of Apple Inc. 36