Installation Guide Table of Contents Glossary Earth Ground Device Handling and Cleaning IXM Install Kit for MYCRO, SENSE 2 and TOUCH 2 IXM Install Kit for MERGE MYCRO SENSE 2 TOUCH 2 MERGE MERGE CR I/O Cable: Top Connector Pin Out for MYCRO, SENSE 2 and TOUCH 2 I/O Cable: Bottom Connector Pin Out for MYCRO, SENSE 2 and TOUCH 2 I/O Cable: Connector Pin Out for MERGE Hardware Tools Required For Installation Hardware Installation Steps Connections for Power Connections for Communication Connections for Operation Electrical Specifications Software Installation System Requirements Software Installation Steps Notices Support 3 4 5 6 7 8 10 12 14 16 18 19 20 21 22 26 28 32 36 37 38 40 44 Glossary ACP COM DAC DOS DSP EGND ESD GND IXM LED NC NO OTG RLY RX SGND SPI SPO TX USB WDATA WGND VDC VIN+
VIN-
INVIXIUM Copyright 2019 Access Control Panel Common Door Access Control Door Open Schedule Door Strike Power Earth Ground Electrostatic Discharge Ground INVIXIUM Light Emitting Diode Normally Closed Normally Open On-the-Go Relay Receive Signal Ground Specific Purpose Input Specific Purpose Output Transmit Universal Serial Bus Wiegand Data Wiegand Ground Volts Direct Current Power Positive (12-24 VDC) Power Return Wired Back Cover Metal Mounting Plate Temporary Back Cover 3 Earth Ground For protection against ESD, which may cause damage or malfunction to the IXM device, Invixium recommends the use of the ground connections between each IXM device and a high quality Earth Ground available at the install site. Please note that installation of any IXM device should be performed by licensed electricians. An Earth Ground wire with lug is provided in the IXM Install Kit. The lug of the Earth Ground wire should be fastened with a screw to the front of the mounting plate. The other end of the Earth Ground wire should be connected to the high quality Earth Ground connection on site. When the IXM device is installed onto the mounting plate, this Earth Ground lug will make direct contact with the Metal Back plate of the IXM device, thus allowing for proper grounding. Please refer to page 21 onwards for step-by-step instructions for mounting plate, device and Earth Ground wire installation. Earth Ground Earth Ground Wire INVIXIUM Copyright 2019 4 Device Handling Do's Handle with care, ensure not to drop or step on the device. Perform occassional cleaning to eliminate a build-up of dust, dirt, oil and residual grime. Device Handling Don'ts Do not install in areas with direct sunlight, high levels of humidity, extreme dust or flammable vapours. Do not allow magnetic objects to come in close contact to any device. Do not install near any heating elements or equipment. Do not attempt to open or disassemble the device, as this will void the product warranty. Do not deploy for any use other than its intended purpose. Do not insert anything other than the correct fitting USB plug into the USB port, located at the bottom of the device. Device Cleaning The component that will require most frequent cleaning is the sensor, as it experiences the most contact. The cleaning should be performed with care and attention, as improper cleaning may damage the sensor or surrounding components. Follow the steps below for proper sensor cleaning procedure:
1. Lightly moisten a new cotton swab or lint free polishing cloth with water or isopropyl alcohol. 2. Gently wipe the surface of the sensor with the moistened cotton swab or cloth. 3. Finish wiping the sensor again with a dry cotton swab or cloth. Do not use harsh or abrasive chemicals to clean the surface of the sensor, as this may cause permanent damage to the device. Do not use sandpaper, steel wool, scouring pads, chlorine, ammonia, bleach, or any inappropriate products for cleaning. WARNING INVIXIUM Copyright 2019 5 The IXM Install Kit for MYCRO, SENSE, TOUCH, SENSE 2 and TOUCH 2 includes:
IXM INSTALL KIT D O L P H I N O L P HIN D D O L P HIN N I H P L O D HIN OLP D D O L P HIN HIN P L O D O L P HIN D D O L P HIN DOLPHIN N I H P L O D O L P HIN D D O L P HIN O L P HIN D Dolphin Crimps
(qty 24) Wall Mounting Screws
(qty 4) Hex Key Earth Ground Wire Metal Mounting Wired Back Cover INVIXIUM Copyright 2019 Plate INVIXIUM Micro USB-On-the-Go Cable Metal Mounting Plate Screw
(qty 1) INVIXium-
Micro USB Extension Cable (4 ft/1.2m) 6 The IXM Install Kit for MERGE includes:
IXM INSTALL KIT N I H P L O D O L P HIN D D O L P HIN O L P HIN D HIN P L O D HIN OLP D Dolphin Crimps
(qty 10) Wall Mounting Screws
(qty 4) Metal Mounting Plate Screw
(qty 1) Wired Back Cover Hex Key Metal Mounting Plate INVIXium-
Micro USB Extension Cable (4 ft/1.2m) Earth Ground Wire INVIXIUM Copyright 2019 7 MYCRO Rugged Front Shell Surge Protection as per EN55024 Multi-color LEDs Sensor Industrial Grade Connectors Solid Metal Back Plate 8 48 38.5 41.70 4.20 m m n i i s n o s n e m D i 8 6 1 2 6 1
. 1 2 8 0 1 1 Front View Side View 30 Front View i w e V e d S i Angled Front View l a u t c A e a P g n t l i t n u o M
&
t c u d o r P O R C Y M e z S i l a u t c A n i e g a p s h i t g n i t n i r p s d n e m m o c e r I M U X V N I I 46.3 8.10 9 SENSE 2 Proximity Sensor Rugged Front Shell Multi-color LEDs Lumidigm Sensor Multispectral Imaging Fingerprint Sensor Surge Protection as per EN55024 Industrial Grade Connectors Solid Metal Back Plate 10 49 46.08 45.20 5.40 m m n i i s n o s n e m D i 7
. 9 9 1 9
. 4 9 1
. 1 2 8 0 1 1 Front View Side View Front View 30 51.85 9 i w e V e d S i Angled Front View l a u t c A e a P g n t l i t n u o M
&
t c u d o r P 2 E S N E S e z S i l a u t c A n i e g a p s h i t g n i t n i r p s d n e m m o c e r I M U X V N I I 11 Proximity Sensor 5 MP Camera Multi-color LEDs Sensor TOUCH 2 Super Strong Protective Glass Optically Bonded Cap Touch Screen Rugged Front Shell Industrial Grade Connectors Solid Metal Back Plate Surge Protection as per EN55024 12 49 46.08 45.20 5.40 m m n 7
. 9 9 1 9
. 4 9 1
. 1 2 8 0 1 1 Front View Side View 30 Front View i w e V e d S i i i s n o s n e m D i l a u t t c A e a P g n l i t n u o M
&
t c u d o r P 2 H C U O T Angled Front View e z S i l a u t c A n i e g a p s h i t g n i t n i r p s d n e m m o c e r I M U X V N I I 51.85 9 13 MERGE NEXT Sensor Active Thermal Sensor Multi-color LEDs Super Strong Protective Glass Optically Bonded Cap Touch Screen Industrial Grade Connectors 14 11 42.50 3.20 m m n i i s n o s n e m D i 8 7 1
. 4 1 2 7 1 0 1 1 0 1 2 8
. Front View Side View Front View 30 i w e V e d S i l a u t t c A e a P g n l i t n u o M
&
t c u d o r P E G R E M Angled Front View 47 37 7.65 e z S i l a u t c A n i e g a p s h i t g n i t n i r p s d n e m m o c e r I M U X V N I I 15 MERGE CR Multi-color LEDs Industrial Grade Connectors 16 17.49 40.50 3.20 m m n
. 4 9 2 4 1
. 4 9 2 4 1
. 9 8 5 3 1 0 1 1 0 1 2 8
. Front View Side View Front View i w e V e d S i Angled Front View 47.19 26.81 34.42 30 7.65 i i s n o s n e m D i l a u t c A e t l a P g n i t n u o M
&
t c u d o r P R C E G R E M e z S i l a u t c A n i e g a p s h i t g n i t n i r p s d n e m m o c e r I M U X V N I I 17 I/O Cable: Top Connector Pin Out for MYCRO, SENSE, TOUCH, SENSE 2 and TOUCH 2 Wired Back Cover RLY_NO RLY_COM RLY_NC ACP_LED1 ACP_LED2 ACP_LED_GND SPI_GND SPI_3 SPI_2 SPI_1 DAC_IN1 DAC_IN2 DAC_IN3 DAC_GND DSP DAC_OUT Pin Wire Color Application Label 2 4 6 8 10 12 14 16 18 20 SPO Line 1 SPO Line 2 SPO Line 3 SPO_1 SPO_2 SPO_3 Ground for SPOs SPO_GND SPI Line 1 SPI Line 2 SPI Line 3 SPI_1 SPI_2 SPI_3 Ground for SPI SPI_GND DAC Output DAC_OUT Door Strike Power*
DAC_DSP SPO_1 SPO_2 SPO_3 SPO_GND Label RLY_NC RLY_COM RLY_NO ACP_LED1 ACP_LED2 Front View Back View Application Relay NC Relay Common Relay NO ACP LED 1 Feedback ACP LED 2 Feedback Pin Wire Color 1 3 5 7 9 11 13 15 17 19 Ground for ACP LED Feedback ACP_LED_GND DAC Input 1 DAC Input 2 DAC Input 3 DAC_IN1 DAC_IN2 DAC_IN3 Ground for DAC Inputs DAC_GND INVIXIUM Copyright 2019
*For SENSE 2 and TOUCH 2 models only 18 I/O Cable: Bottom Connector Pin Out for MYCRO, SENSE, TOUCH, SENSE 2 and TOUCH 2 Wired Back Cover Front View Back View Pin Wire Color Application EGND VIN-
VIN+
RS232_RX RS232_TX SGND RS-485+ (B) RS-485- (A) RS-485_T TCP/IP WGND WDATA_OUT1 WDATA_OUT0 WDATA_IN1 WDATA_IN0 RJ45 Receptacle Label Pin Wire Color Application RS-232 Data Receive Label RS-232_RX 1 3 5 7 9, 11, 13, 15, 17, 19, Power (+12-24 VDC) Power Ground Earth Ground RS-485 Terminated (Optional)*
Ethernet or PoE VIN+
VIN-
EGND RS-485_T TCP/IP
* required. To do this, short the RS-485_T wire with RS-485+ wire. NOTE PoE only available for SENSE 2 and TOUCH 2 INVIXIUM Copyright 2019 2 4 6 8 10 12 14 16 18 20 RS-232 Data Transmit RS-232_TX Signal Ground SGND RS-485 Non-Inverting Line RS-485 Inverting Line Wiegand Data Input Line 0 Wiegand Data Input Line 1 RS-485+ (B) RS-485- (A) WDATA_IN0 WDATA_IN1 Wiegand Data Output Line 0 Wiegand Data Output Line 1 WDATA_OUT0 WDATA_OUT1 Ground for Wiegand WGND 19 EGND VIN-
VIN+
RS485- (A) RS485+(B) DAC_OUT SPO_1 WDATA_OUT0 DGND WDATA_OUT1 DAC_IN2 DAC_IN3 TAMPER RLY_NO SGND RLY_NC RLY_COM WDATA_IN1 WDATA_IN0 DAC_IN1 I/O Cable: Connector Pin Out for MERGE Wired Back Cover Front View Back View Pin Wire Color Application 1 3 5 7 9 11 13 15 17 19 INVIXIUM Copyright 2019 Power (+12-24 VDC) Power Ground Earth Ground Ground for Wiegand Label VIN+
VIN-
EGND DGND Wiegand Data Output Line 1 WDATA_OUT1 Door Access Control Input 2 DAC_IN2 Door Access Control Input 3 DAC_IN3 Tamper Line Relay Normally Open Signal Ground TAMPER RLY_NO SGND Pin Wire Color Application Label 2 4 6 8 10 12 14 16 18 20 RS-485 Inverting Line RS485- (A) RS-485 Non-Inverting Line RS485+(B) Door Access Control Output DAC_OUT Specific Purpose Output Line 1 SPO_1 Wiegand Data Output Line 0 WDATA_OUT0 Door Access Control Input 1 DAC_IN1 Wiegand Data Input Line 0 Wiegand Data Input Line 1 Relay Common Relay Normally Closed WDATA_IN0 WDATA_IN1 RLY_COM RLY_NC 20 Hardware Tools Required For Installation Battery powered Screwdriver Hammer*
Power Drill*
Measuring Tape Ratchet-style Crimping tool Pencil Manual Screwdriver Installation of any IXM device should be performed by licensed electricians.
*Depending on the mounting surface, the Power Drill and Hammer may not be required. NOTE INVIXIUM Copyright 2019 21 1 Ensure Power is Off This protects the device being installed. 2 IXM Install Kit Remove the following items from the kit:
ON O F F 3 Mark the Screw Holes INVIXIUM recommends the use of the 4 circular holes for mounting. Refer to diagrams from page 9 onwards for actual dimensions Ideal mounting height is 135 -
140 cm from the ground to the top of the device. But also be sure to align the device in case of multiple installations. INVIXIUM Copyright 2019 D O L P H I N O L P HIN D D O L P HIN N I H P L O D HIN OLP D D O L P HIN HIN P L O D O L P HIN D D O L P HIN DOLPHIN N I H P L O D O L P HIN D D O L P HIN O L P HIN D 4 Drill Holes If required, drill holes where marked and install the appropriate wall anchors (not included) using the hammer. s m c 0 4 1
-
5 3 1 22 5 Get Wires Get access to the installation wires either from behind the wall of from the wiring conduit. Feed wires through the square hole of the mounting plate. 6 Insert Screws Align the holes of the mounting plate with the wall anchors and attach the mounting plate with the screws provided in the IXM Install Kit. INVIXIUM recommends the use of an electric or battery-powered screwdriver for this step. 7 Identify the Connections:
1 Power & Grounding DC Power VIN+
VIN-
EGND RS-485 SGND RS-485+
RS-485-
ACP ACP_LED1 ACP_LED2 ACP_LED_GND WDATA_OUT0 WDATA_OUT1 WGND 2 Communications 3 Operations INVIXIUM Copyright 2019 OR OR OR PoE RJ-45 Receptacle EGND Ethernet RJ-45 Receptacle DAC RLY_NC RLY_COM RLY_NO DAC_IN1 DAC_IN2 DAC_OUT DSP OR RS-232 RS-232_RX RS-232_TX SGND USB OR Refer to pages 26 & 27 for Power connections, pages 28-31 for Network or Serial Communication connections and pages 32-35 for Operation connections. 23 8A Make the Connections Connect the required wires using the Dolphin crimps provided in the IXM Install Kit (or any similar crimps) and a ratchet style crimping tool. Insert two wires (no stripping required) into the open end of the crimp and then using the crimping tool, clamp down on the middle of the crimp. N I H P L O D Earth Ground Wire Lug 8B Connect Earth Ground Connect the lug of the Earth Ground wire directly to the front of the mounting plate using one of the Wall mounting screws. Ensure that the lug is secured tightly as to make the necessary contact between the device and the mounting plate. Connect the other end of the Earth Ground wire to the Earth Ground connection of the install site with a crimp. Ensure all required connections are made to each device in the setup prior to turning on the power. Checklist:
Connections for Power & Grounds (DC or PoE) Connections for Communications (Ethernet, RS-485 or RS-232) Connections for Operation (ACP or DAC) INVIXIUM Copyright 2019 24 9 Attach the Device 10 Secure the Device Take the IXM device and unscrew the Temporary Back Cover, keeping the screws handy. Connect the Wired Back Cover to the back of the device by lining up the connectors. Secure the Wired Back Cover with the same screws. Next, hang the IXM device onto the mounting plate as shown in the series of diagrams below. Finally, secure the device on the bottom to the mounting plate with the Metal Mounting Plate screw provided in the IXM Install Kit. 1 2 3 INVIXIUM Copyright 2019 INVIXIUM 25 Connections for Power UPS UPS DC Power Supply MYCRO VIN+
VIN-
INVIXIUM recommends:
EGND 12-24 VDC regulated power supply (Safety tested and FCC/IC/CE certified) Dedicated Power Supply for each IXM device (minimum 1A) Dedicated Power Supply for each IXM device powering door strike (minimum 1.5A) Use of a battery back-up or UPS with built-in surge protection If sharing power supplies, ensure that each device is supplied with minimum 1A per device (i.e. Powering 2 devices will require a supply with output current of 2A) Product Warranty is void if improper power (under or over) is supplied to the device. WARNING INVIXIUM Copyright 2019 Power Connections VIN+
VIN-
EGND 26 Connections for Power Over Ethernet (PoE) Available on MERGE, SENSE, TOUCH X, SENSE 2 and TOUCH 2 SENSE 2 TOUCH 2 INVIXIUM recommends:
Ethernet/PoE Connections A centralized Power Sourcing Equipment (PSE) for full PoE deployments (not included) Use of a battery back-up or UPS with built-in surge protection Both IEEE 802.3af power transmission modes (A and B) are supported. NOTE INVIXIUM Copyright 2019 TX+
TX-
RJ45_PIN4 RX+
RX-
RJ45_PIN7 27 Ethernet and Wi-Fi Communication Ethernet:
Switch/Router required CAT 5 cabling or better WiFi:
Wireless router to LAN/WAN 802.11b/g/n protocol WEP, WPA and WPA2 encryptions supported DHCP enabled by default IXM WEB Router connected ter connected to LAN/WAN LAN/WAN MERGE CR MERGE MYCRO SENSE 2 TOUCH 2 INVIXIUM Copyright 2019 28 RS-485 Network Communication INVIXIUM recommends:
Daisy chain configuration Maximum 31 devices in the network Both RS-485 converter and the last device in the chain should be terminated (not included, refer to NOTE below for correct Resistor vaues) Connect the IXM device to PC via RS-485-to-Serial (RS-232 or USB) Converter Maximum cable length of 1200m (4000 ft.) at 9600 bps baud rate IXM WEB RS-485 to USB Converter MERGE MERGE CR R = 120 ohms for Standard RS-485 Cabling R = 100 ohms for CAT5/6 Cabling NOTE INVIXIUM Copyright 2019 RS-485 Connections SGND RS-485+
RS-485-
29 Serial Communication 1 2 3 4 5 IXM WEB IXM WEB TOUCH 2 TOUCH S G N D R S 2 3 2 _ R X R S 2 3 2 _ T X USB-to-Serial Converter B-to-Serial Converter RS-232:
Connect IXM device directly to the DB9 Serial port of the PC (if available) DB9 connectors and cables are not included MYCRO, SENSE 2 and TOUCH 2 only NOTE INVIXIUM Copyright 2019 RS-232 Connections RS-232_RX RS-232_TX SGND 30 USB Communication ommunication SENSE 2 SENSE 2 Host PC Host PC Micro USB Cable Micro USB Cable USB:
Connect a Flash Drive via Micro USB OTG cable and perform functions like upgrading firmware and downloading transaction logs ect a Flash Drive via Micro USB OTG cable and perform functions like upgrading firmware and downloading transaction logs USB port can also be used to connect to a PC running IXM WEB via Micro USB cable Driver installation is required and will automatically initiate once the device is connected INVIXIUM Copyright 2019 31 Access Control Panel Connections for MERGE MERGE MERGE ACP:
Wiegand connections available for ACP operation INVIXIUM recommends the use of Wiegand Output Data 0, 1 and GND connection INVIXIUM Copyright 2019 WDATA_OUT0 WDATA_OUT1 DGND Wiegand Connections WDATA_OUT0 WDATA_OUT1 DGND 32 Access Control Panel Connections for MYCRO, SENSE, TOUCH, SENSE 2 and TOUCH 2 TOUCH 2 3 3 ACP_LED1 ACP_LED2 ACP_LED_GND WDATA_OUT0 WDATA_OUT1 WGND ACP:
LED and Wiegand connections available for ACP operation INVIXIUM recommends the use of Wiegand Output Data 0, 1 and GND connection ACP_LED signals can be used if available on the Access Control Panel. IXM devices support up to 2 wires + GND for LED status. NOTE INVIXIUM Copyright 2019 Top Connector LED Bottom Connector Wiegand ACP_LED1 ACP_LED2 WDATA_OUT0 WDATA_OUT1 ACP_LED_GND WGND 33 Door Access Control Connections for MYCRO, MERGE, SENSE, TOUCH, SENSE 2 and TOUCH 2 TOUCH 2 RLY_NO RLY_COM DAC_IN1 DAC_OUT DAC_OUT DAC_IN2 Snubber Diode Door Strike Door Strike Power Supply Door Contact Request to exit
*Max Relay Rating = 1 Amp @ 24 VDC DAC:
INVIXIUM recommends a separate power supply for Door Strike (not included) for this configuration Snubber Diode required for Door Strike (not included) DAC Connections Example above shows use of RLY_NO, but RLY_NC may be used instead if required by the Door Strike Internal Relay rated upto max of 1A @ 24VDC For motion detector instead of Request-to-Exit-buttom, connect the following signals:
(1) DAC_OUT to the COM and (2) DAC_IN2 to the Relay NO of the motion detector INVIXIUM Copyright 2019 RLY_NC RLY_COM RLY_NO DAC_IN1 DAC_IN2 DAC_OUT 34 DAC Connections for Device Powers Door Strike (SENSE 2 and TOUCH 2 only) TOUCH 2 RLY_NO RLY_COM DAC_GND DAC_DSP DAC_IN1 DAC_OUT Snubber Diode Door Strike
- +
DAC_OUT DAC_IN2
*Max Relay Rating = 2 Amp @ 24 VDC Door Contact Request to exit DAC:
The IXM device powers the door strike in this configuration. Only applicable to SENSE 2 and TOUCH 2. Device can supply 500mA@12V Snubber Diode required for Door Strike (not included) Example above shows use of RLY_NO, but RLY_NC may be used instead if required by the Door Strike Internal Relay rated upto max of 2A @ 24 VDC For motion detector instead of Request-to-Exit-buttom, connect the following signals:
(1) DAC_OUT to the COM and (2) DAC_IN2 to the Relay NO of the motion detector INVIXIUM Copyright 2019 DAC Connections RLY_NC RLY_COM RLY_NO DAC_IN1 DAC_IN2 DAC_OUT DAC_DSP DAC_GND 35 Software Installation System Requirements To successfully install and run IXM WEB, the system must meet the following minimum requirements:
PC Workstation:
One of the following Operating Systems 2 GHz Intel Pentium 4 or equivalent
(2.4 GHz or higher recommended) 4 GB RAM (6 GB or higher recommended) 2 GB Free Hard Disk Space Windows 10, 8.1 and 7 (32-Bit & 64-Bit) Windows 7 Home Premium Edition Windows Vista Service Pack 2 or higher versions Windows Server 2016, 2012, 2012 R2, 2008, 2008 R2 850 MB Hard Disk Space for x86 systems or 2 GB Hard Disk Space for x64 systems Microsoft .NET Version 4.0 2 GB Hard Disk Space recommended for SQL Server 2008 Express Edition SP1 Available COM or USB Port Ethernet Card (10/100 Mbps Ethernet connections) Monitor capable of displaying at least 1024 x 786 high color resolution One of the following Web Browsers (Client):
Internet Explorer version 11.0 Google Chrome version 40.0 and above Mozilla Firefox version 40.0 and above Microsoft Edge version 38.14393 and above Apple Safari (MAC OS only) version 5.1.7 and above IXM WEB will install the following:
Microsoft .NET Framework (version 4.0) SQL Server 2008 Express Edition Service Pack 1 Microsoft Internet Information Services (version 7.5) Windows Installer (version 4.5) INVIXIUM Copyright 2019 Windows Professional or Enterprise Editions 37 Software Installation Steps Step 1 Go to ixmweb.invixium.com. Click Get IXM WEB. Provide the required details and Click Submit. An email with the latest IXM WEB Package will be sent to the email ID provided. (Contact Support if using a customized solution). Step 2 Download and Extract the package. Run IXM WEB.exe file. Step 3 There are two installation options: Install or Advanced. INVIXIUM recommends selecting INSTALL option for rapid installation. The ADVANCED process allows for:
entering a different install path checkbox for installing SQL Server database entering a specific Port number checkbox for installing Certificates A Windows dialog may pop up to provide a warning about installing from an unreliable source. Click Yes to proceed with the install. NOTE INVIXIUM Copyright 2019 38 Step 4 During the installation process, the status of the install will be shown. Step 5 When the installation is complete, click EXIT. IXM WEB icon is now on the desktop. Step 6 Run IXM WEB to launch the application in the default web browser to setup the Database and Admin credentials. INVIXIUM Copyright 2019 39 FCC Information to Users (English) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. 2. This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/TV technician for help NOTE Informations de la FCC aux Utilisateurs (en Franais) Cet appareil est conforme la partie 15 des rgles de la FCC. Son fonctionnement est soumis aux deux conditions suivantes:
1. 2. Cet appareil ne doit pas provoquer d'interfrences nuisibles Cet appareil doit accepter toute interfrence reue, incluant toute interfrence pouvant causer un fonctionnement indsirable INVIXIUM Copyright 2019 40 NOTIFICATION Cet quipement a t test et s'est avr conforme aux limites pour un appareil numrique de Classe B, conformment la partie 15 des rgles de la FCC. Ces limites sont conues pour fournir une protection raisonnable contre les interfrences nuisibles dans une installation rsidentielle. Cet quipement gnre, utilise et peut mettre des frquences radio et, s'il n'est pas install et utilis conformment aux instructions, il peut causer des interfrences nuisibles pour les communications radio. Cependant, il n'existe aucune garantie que des interfrences ne se produiront pas dans une installation particulire. Si cet quipement provoque des interfrences nuisibles la rception radio ou de tlvision, ce qui peut tre dtermin en l'teignant et rallumant, l'utilisateur est encourag essayer de corriger l'interfrence par une ou plusieurs des mesures suivantes:
Rorienter ou dplacer l'antenne de reception Augmentez la distance entre l'quipement et le rcepteur Connecter l'quipement une sortie sur un circuit diffrent de celui sur lequel le rcepteur est branch Pour obtenir de laide, consulter le revendeur ou un technicien radio / TV expriment NOTE FCC RF Radiation Exposure Statement (English) This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. Industry Canada RF Radiation Exposure (English) This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. Industrie Canada exposition aux radiations RF (en Franais) Cet quipement est conforme aux limites d'exposition aux rayonnements IC tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 20cm de distance entre la source de rayonnement et votre corps. INVIXIUM Copyright 2019 41 CE Information to Users (English) All INVIXIUM devices have the CE mark for conformance with EMC Directive 89/336/EEC, and Low Voltage Safety Directive 73/23/EEC. Device with RFID components are compliant with R&TTE Directive 1999/5/EC, and are Class 1 Devices. Informations de la CE aux Utilisateurs (en Franais) Tous les dispositifs de INVIXIUM ont le marquage CE de conformit la directive CEM 89/336/CEE et basse tension de scurit Directive 73/23/CEE. Les appareils avec composants RFID sont conformes aux Directive R & TTE 1999/5/CE. et sont des appareils de classe 1. ISED Information to Users (English) This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
1. 2. This device may not cause interference. This device must accept any interference, including interference that may cause undesired operation of the device. Industrie Canada Information pour les Utilisateurs (en Franais) Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
1. 2. Lappareil ne doit pas produire de brouillage;
Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. INVIXIUM Copyright 2019 42 Warning to Users (English) WARNING Changes or modifications not expressly approved by INVIXIUM could void the user's authority to operate the equipment. Avertissement aux Utilisateurs (en Franais) WARNING Les changements ou modifications non expressment approuvs par INVIXIUM pourraient annuler l'autorit de l'utilisateur utiliser l'quipement. INVIXIUM Copyright 2019 43 For Technical or Customer Support issues, please contact your Local Authorized Reseller. For all other inquiries, please contact us at support@invixium.com For detailed information, please visit our website:
invixium.com Enjoy the Experience. Some features may vary based on device models. Copyright 2018, INVIXIUM. All rights reserved. P/N XAD-00E-119-05G INVIXIUM.COM INSTALLATION GUIDE INGUIDE 2018 Google Inc. All rights reserved. Chrome browser is a trademark of Google Inc. Firefox logo is a registered trademark of the Mozilla Foundation. Windows , Edge and Internet Explorer are trademarks of the Microsoft group of companies. Safari is a trademark of Apple Inc. 44