1 |
|
User Manual | Users Manual | 1.89 MiB | May 25 2022 / November 20 2022 | delayed release | ||
1 |
|
Internal Photos | Internal Photos | 3.32 MiB | May 25 2022 / November 20 2022 | delayed release | ||
1 |
|
External Photos | External Photos | 1.08 MiB | May 25 2022 / November 20 2022 | delayed release | ||
1 |
|
Label | ID Label/Location Info | 168.19 KiB | May 25 2022 | |||
1 |
|
Agency Letter | Cover Letter(s) | 27.38 KiB | May 25 2022 | |||
1 | Block Diagram | Block Diagram | May 25 2022 | confidential | ||||
1 |
|
Confidentiality Letter | Cover Letter(s) | 77.88 KiB | May 25 2022 | |||
1 | Operating Description | Operational Description | May 25 2022 | confidential | ||||
1 | Part List | Parts List/Tune Up Info | May 25 2022 | confidential | ||||
1 |
|
SAR Test Report | RF Exposure Info | 3.95 MiB | May 25 2022 | |||
1 | Schematic 6 | Schematics | May 25 2022 | confidential | ||||
1 | Schematics | Schematics | May 25 2022 | confidential | ||||
1 | Schematics 2 | Schematics | May 25 2022 | confidential | ||||
1 | Schematics 3 | Schematics | May 25 2022 | confidential | ||||
1 | Schematics 4 | Schematics | May 25 2022 | confidential | ||||
1 | Schematics 5 | Schematics | May 25 2022 | confidential | ||||
1 |
|
Test Report | Test Report | 5.62 MiB | May 25 2022 | |||
1 |
|
Test Setup Photos | Test Setup Photos | 548.29 KiB | May 25 2022 / November 20 2022 | delayed release |
1 | User Manual | Users Manual | 1.89 MiB | May 25 2022 / November 20 2022 | delayed release |
InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com IMPORTANT SAFETY INFORMATION User information on the disposal of electrical and electronic devices
(private households) Environmental influences Note: Never point the lens of the device directly at intense heat sources such as the sun or laser equipment. The objective lens and eyepiece can function as a burning glass and damage the interior components. Risk of swallowing Caution: Do not place this device in the hands of small children. Incorrect handling can cause small parts to come loose which may be swallowed. Safety instructions for use
- Do not expose the device to fire or high temperatures.
- The battery capacity decreases when operated in a cold ambient temperature. This is not a fault and occurs for technical reasons.
- Always store the device in its carrying bag in a dry, well-ventilated space. For prolonged storage, remove the batteries.
- Do not expose your device to extreme temperatures lower than - 20C and higher than + 50C. The WEEE symbol on products and/or accompanying documents indicates that used electrical and electronic products must not be mixed with ordinary household waste. For proper treatment, recovery and recycling, take these products to the appropriate collection points where they will be accepted without charge. In some countries, it may also be possible to return these products to your local retailer when you purchase a corresponding new product. The proper disposal of this product serves to protect the environment and prevents possible harmful effects on human beings and their surroundings, which may arise as a result of incorrect handling of waste. More detailed information on your nearest collection point is available from your local authority. In accordance with state legislation, penalties may be imposed for the improper disposal of this type of waste. For business customers within the European Union Please contact your dealer or supplier regarding the disposal of electrical
- The product shall only be connected to a USB Type C interface. and electronic devices. He will provide you with further information.
- If the device has been damaged or the battery is defective, send the device to our after-sales service for repair. Information on disposal in other countries outside of the European Union All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com This symbol is only applicable in the European Union. Please contact without glasses. It offers a full field of view in both cases. your local authority or dealer if you wish to dispose of this product and ask for a disposal option. Intended use The device is intended for displaying heat signatures during nature observation, remote hunting observations and for civil use. This device is not a toy for children. Use the device only as described in this instruction manual. The manufacturer and the dealer accept no liability for damages which arise due to non-intended or incorrect use. Function test
- Before use, please ensure that your device has no visible damage.
- Test to see if the device displays a clear, undisturbed image.
- Check that the settings for the thermal imaging camera are correct. See the notes in the section Operation. Installing/removing the battery The Saim thermal imaging riflescope need to install two CR123 batteries for use. Refer to the Section Battery Installation for details. Observation with and without glasses Thanks to the flexible eyeshade, the Saim series can be used with or All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com 1 Specification Model Microbolometer Resolution, pixels Pixel size, m NETD, mk Frame rate, Hz Optical Characteristics Objective lens, mm Field of view Magnification, x E-zoom, x Diopter Adjustment, D Detective range, m
(Target size:1.7m*0.5m, P(n)=99%) Display Display type Resolution, pixels Power Supply Battery type Saim SCH50 640 512 12 40 50 50 8.8 6.6 2.91 - 11.64 1 / 2 / 3 / 4
-5 ~ +5 2597 OLED 1024 768 CR123 2 External Power Supply 5V (Type C USB) Max. Operation time (at t=22), h 3.5 Operational Characteristics Wi-Fi & Recorder Compass & Motion sensor Max. Recoil Power on Rifled Weapon, g/s Degree of protection, IP code Amount of built-in memory, Gb 1000 IP67 32 Operating Temperature Range,
-10~+50 Weight (without batteries), g 510 Dimension, mm 216 61 61 The actual operating time depends on the intensity of using Wi-Fi, video recorder. Improvements may be made to the design and software of this product to enhance its useful features. Technical parameters of the device may be improved without prior notice of the customer. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com 2 Description 3 Components and Controls The Saim series is a low-cost Thermal Imaging Riflescope, which can be 1. Eyeshade mounted on various firearms for night hunting and target observation. Its 2. Eyepiece diopter adjusting ring compact size and lightweight design make it easy to carry. What makes it 3. Type C interface outstanding is long operation hours, good concealment and great ability 4. C (Camera) button to detect, recognize and identify objects or targets fast and easy. The 5. M (Menu) button Saim series effective at close and long ranges irrespective of light and 6. P (Power) button harsh weather conditions, that is, in total darkness, through heavy smoke, 7. Battery compartment haze, fog, and dust. 8. Lens focus ring 9. Objective lens 10. Lens cover All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com 4 Battery Installation Attention
- Disposable batteries are ONLY supported! Risks are existing to use rechargeable batteries due to nonstandard quality.
- Please do not use different types of batteries or batteries with different power levels.
- The Saim series supports external power supply via Type-C cable with a USB icon displayed on the screen. Open the battery compartment cover (7) anticlockwise according to the 5 Icons Instructions prompt identification on the cover. Install the two CR123 batteries correctly according to the marking on the battery cover and inside it. When done, replace the battery cover - the latches from both sides of the cover will pull out (see the drawing above), press it until its clicking Image mode: White hot Image mode: Black hot Image mode: Red hot Image mode: Color position - make sure the cover is closed on both sides correctly.
E-zoom Battery level is displayed on the status bar (
). When the battery icon turns red, please replace the new battery in time. It is necessary to power off before replacing the batteries. Display brightness Image sharpness Image brightness Image contrast All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com Ultraclear mode Wi-Fi Auto correction mode Video out PIP Digital compass Motion sensor Battery type Zeroing type Image hue More Zeroing Defective pixels calibration Compass calibration Stadiametric Rangefinder Setting Time and date System information Factory reset Return to the Main Menu Battery indicator 6 Operation Open the lens cover (10). Press and hold down the P (6) button for 3s to power the riflescope on. Waite for 6s until thermal image appears on the display. Diopter Adjustment: Adjust the sharp resolution of the icons on the display by rotating the diopter adjusting ring (2) of the eyepiece. Lens Focus Adjustment: rotate the lens focus ring to focus (8) on the object being observed. Calibration: calibration the image with a short press of the M (5) and C
(4) button for shutter correction or long press the M (5) and C (4) button for background correction. Image Settings: adjust the image mode, display brightness, image sharpness, image brightness, image contrast in the shortcut menu (for more details, see the Shortcut Menu Functions section) Standby Mode: Briefly press the P (6) and M (5) buttons at the same All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com time to switch the device to the standby mode. Briefly press the P (6) and M (5) buttons again to wake up the device. 7 Zeroing Power off: to power off the riflescope, long press P (6) button for 5s until the shutdown option menu appears, select the to shut down and to cancel. Then short press the M (5) button to confirm the selection. Reticle On: click the M (4) button four times in a row while pressing and holding the P (5) + C (4) button to invoke the reticle function for the first time use, then long press the P (5) + M (4) + C (4) button simultaneously for 7 seconds to turn the reticle on. This function should be activated when the reticle first enabled. Attention Zeroing is recommended to be done at the temperature close to the riflescope operating temperature. Before implementing zeroing setting, please make sure that the reticle is on and zeroing type is selected in the main menu. Mount the riflescope on your weapon. Set a target at 100m distance, and power on the riflescope. For the first use of the riflescope, please make sure that the reticle is on before zeroing (according to the instructions of section 6 Operation). Long press the M (5) button on the home screen to enter the main menu. Select one zeroing profile in the main menu. When the reticle is turned off, all the operations related to it in the menu Select the Zeroing item in the will be hidden, including the adjustment of the reticle color and pattern sunmenu of the MORE item,
(in shortcut menu), the options of zeroing and blind pixel correction in and press the M (5) button to the advanced menu. enter the Zeroing interface. In the Zeroing interface, the reticle is shown as a small cross for All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com position adjustment. marked on the scale plate consistent with the measured distance. Then aiming the center of the reticle at the bulls-eye 100 meters away Short press the M (5) button to switch the movement direction and shooting. between UP-DOWN and RIGHT-LEFT. Locating the bullet hole after shooting. Press and hold down the M (5) button to save and exit when the If the bullet hole can be seen on the display screen:
process is done. Keeping the position of the device fixed, press and hold the M (5) Notes and C (4) button at the same time to freeze the image, and a snowflake icon appears on the upper-left corner of the screen. Move the reticle to the position of the actual impact point by the P
(6) / C (4) button. Short press the M (5) button to switch the movement direction between UP-DOWN and RIGHT-LEFT. Press and hold down the M (5) button to save and exit when the process is done. If the bullet hole cannot be seen on the display screen:
Keep the position of the device fixed, and measure the horizontal and vertical distance between the bulls eye and the bullet hole. According to the measured distance, move the reticle position by long or short pressing the P (6) / C (4) button until the distance
- To ensure the accuracy of the position, aiming the bulls-eye again and repeat the operations until the bulls-eye is hit.
- In the zeroing interface, the reticle moves one pixel with a short pressing P (6) / C (4) button to the corresponding direction while ten pixels movement with a long-pressing. One pixel means to move 1.5cm at a distance of 100 meters or 0.54 inches at a distance of 100 yards.
- Short press the P (6) + M (5) + C (4) buttons at the same time to switch units (cm/m, inch/yard).
- In the zeroing interface, there is a white dot that represents the original position of the reticle before calibration implement.
- After zeroing, the center of all reticle will be changed accordingly. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com 8 Shortcut Buttons Instructions 9 Shortcut Menu To quickly realize the frequently used functions, the Saim SCH series The basic settings (using the function of smooth digital zoom, adjusting made the default shortcut buttons of the most commonly used functions in the display brightness, switching the image palette, adjusting the image the observation interface. sharpness, setting the image brightness and contrast, selecting the reticle color and pattern) can be changed using the shortcut menu. Button Short press Long press In the home screen, short press the M (5) button to enter the shortcut P button E-zoom Power on /off menu. M button Enter the shortcut menu Enter the main menu There are four pages (when the reticle function is invoked) and two C button Take a photo Video recording functions on each page, one at the top and one at the bottom. M + C button Shutter correction Background correction On each page, press the P (6) button briefly to switch the options of the Turn the standby mode Turn the stadiametric top function, and press the C (4) button briefly to switch the options of P + M button on/off rangefinder function on/off the bottom function. And each function has four options P + M + C Switch the units between button cm/m and inch/yard Press the M (5) button briefly to switch the next page. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com Shortcut Menu Options and Descriptions Times of pressing the M (5) button Shortcut Menu Interface Operation Enter the first page of the shortcut menu to 1 time adjust the image palette and screen brightness 2 times Enter the second page of the shortcut menu to adjust E-zoom and image sharpness Short press the P (6) button to adjust image palette among white hot, black hot, red hot and color. Short press the C (4) button to adjust the image brightness level from 1 to 4 gradually enhanced. Short press the P (6) button to perform E-zoom parameter x1, x2, x3 and x4. Short press the C (4) button to adjust the image brightness level from 1 to 4 gradually enhanced. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com Enter the third page of the shortcut menu to 3 times adjust the image brightness and image contrast Short press the P (6) button to cyclically adjust the image brightness level from 1 to 4 gradually enhanced. Short press the C (4) button to adjust the image brightness level from 1 to 4 gradually enhanced. Short press the P (6) button to adjust the reticle color: white, black, red and 4 times Enter the fourth page of the shortcut menu to green. adjust reticle color and reticle pattern Short press the C (4) button to select the reticle pattern. There are 8 patterns for selection. 5 times Exit to the home screen All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com 10 Main Menu Long press the M (5) button to exit the main menu. In the home screen, press and hold the M (5) button to enter the main menu, which including Ultraclear mode, Wi-Fi, auto shutter correction, video output, PIP, compass, motion sensor, battery type, zeroing type, image hue, more. Press the P (6) / C (4) button to move through the main menu items. Press the M (5) button briefly to set up the item parameter or to enter the function interface. Main Menu Options and Descriptions Turn Ultraclear mode on/off Ultraclear Press and hold down the M (5) button to enter the Main Menu. Select the Ultraclear menu option with the P (6) / C (4) button. Turn Ultraclear mode on /off with a short press of M (5) button, along with the sound of shutter calibration. The icon will be displayed on the status bar in the upper left corner of the screen when the Ultraclear mode is on. Under heavy fog, rain or snow weather, Ultraclear Mode will show more image details. Wi-Fi Turn Wi-Fi function on/off Press and hold down the M (5) button to enter the Main Menu. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com Select the Wi-Fi menu option with the P (6) / C (4) button. Turn Wi-Fi function on /off with a short press of M (5) button. The icon will be displayed on the status bar in the upper left corner of the screen when the wi-Fi is on. Turn the auto shutter correction on/off Press and hold down the M (5) button to enter the Main Menu. Select the Auto Shutter Correction menu option with the P (6) / C (4) button. Auto shutter Briefly press of the M (5) button to turn the auto shutter correction on /off. correction The icon will be displayed on the status bar in the upper left corner of the screen when the auto shutter correction is on. Before automatic calibration, there will be a 5 second countdown prompt behind the shutter icon on the status bar, that can be to cancelled this calibration during countdown with a short press of the Power (3) button. Turn video output on/off Video Output Press and hold down the M (5) button to enter the Main Menu. Select the Video Output option with the P (6) / C (4) button. Briefly press of the M (5) button to turn video out on/off. The icon will be displayed on the lower right corner of the screen when the video output function is on. Video out function enable connectivity with an eternal display or recording device. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com Turn Picture-in-Picture on/off Press and hold down the M (5) button to enter the Main Menu. PIP Select the PIP option with the P (6) / C (4) button. Briefly press of the M (5) button to turn PIP on/off. When the PIP function is on, a small window will appear on the top of the display. Compass Turn on/off the digital Compass function Press and hold down the M (5) button to enter the Main Menu. Select the Compass menu option with the P (6) / C (4) button. Briefly press of the M (5) button to turn the digital compass on/off. When the compass function is turned on, it will reveal in the center of top status bar. Turn on/off the motion sensor Press and hold down the M (5) button to enter the Main Menu. Motion Sensor Select the Motion Sensor menu option with the P (6) / C (4) button. Briefly press of the M (5) button to turn the motion sensor on/off. Two scales are displayed on the right sides of the screen when the motion sensor is on. The horizontal scale shows tilt angle, and the vertical one shows pitch angle. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com Select the battery voltage Battery Type Press and hold down the M (5) button to enter the Main Menu. Select the Battery Type option with the P (6) / C (4) button. Briefly press of the M (5) button to select 3V or 3.7V according the battery voltage. 3V is selected for dischargeable battery and 3.7V is for chargeable battery, but dischargeable battery is suggested only. Select the zeroing type Zeroing Type Press and hold down the M (5) button to enter the Main Menu. Select the Zeroing Type option with the P (6) / C (4) button. There are four types for selection. Briefly press of the M (5) button to select one zeroing type. Select the image hue Press and hold down the M (5) button to enter the Main Menu. Image hue Select the Image Hue option with the P (6) / C (4) button. Briefly press of the M (5) button to select C or W. C is for cool hue, and W is for warm hue. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com Enter the secondary menu for more settings Press and hold down the M (5) button to enter the Main Menu. Select the More menu option with the P (6) / C (4) button. Briefly press of the M (5) button to enter the secondary menu for more settings, including zeroing, defective pixels calibration, compass calibration, stadiametric rangefinder setting, time setting, system information, factory reset and return to the main menu. Enter the zeroing interface More Saim series support the 100m zeroing distance. Select the Zeroing option with the P (6) / C (4) button in the More submenu. Briefly press of the M (5) button to enter the zeroing interface. Zeroing Then aim the center of the reticle at the bulls-eye 100 meters away and shoot. Locate the bullet hole after shot. Then, zero your riflescope according the Section Zeroing. Press and hold the M (5) button to save and exit to the More submenu. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com Defect pixels are pixels that do not change brightness compare with others on the image, they are either brighter or darker than surrounding pixels. Saim series offer the possibility of removing any defective pixels on the sensor using software, as well as to cancel any deletion. Select the Pixels Defect Calibration option with the P (6) / C
(4) button in the More submenu. Briefly press of the M (5) button to enter the pixels defect calibration interface. A small cross cursor instead of the reticle will appear on the center of the screen. Pixels Defect Calibration The Picture in Picture (PIP) window will appear on the lower left corner of the screen. A tooltip is appeared on the bottom of the screen that displays the number of the blind pixels calibrated, the movement direction and location. Move the cursor to align with the defective pixel with a short or long press the P (6) / C (4) button. Short press to move one pixel every time and long press to move ten pixels once. Switch the movement direction with a short press of the M (5) button. After selecting the blind pixel, long press P (6) and C (4) button to calibrate the defective pixel, and press the same button again for cancelation. Repeat the above processes until all blind pixels are calibrated. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com Press and hold the M (5) button to save the calibration and exit to the More submenu. Calibrate the digital compass Select the Compass Calibration option with the P (6) / C (4) button in the More submenu. Briefly press the M (5) button to enter the Compass Calibration interface. Compass Calibration An icon like a triaxial coordinate system appears on the screen. Follow the icon prompt to rotate the riflescope along three axes at least 360 degrees each axis in the 15 seconds. After 15s, the calibration is finished and exit to the home screen. Setting the prey type, prey height and effective range Select the Stadiametric Rangefinder Setting option with the P (6) / C (4) button in the More submenu. Briefly press the M (5) button to enter the Stadiametric Stadiametric Rangefinder Setting Rangefinder Setting interface. In the setting interface, the order from left to right is prey type, prey height and effective range. Switch item among the three functions with a briefly press of the M (5) button. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com When the item is selected, the icon turns blue and a pair of triangles appear above and below the icon. Press the P (6) / C (4) button to set the parameter of the item. There are five prey type for selection, including deer (
), wild boar (
), coyote (
), hare (
) and custom (
). Each prey type corresponds to a default height with a default effective range of 100m. The corresponding default height is 1.7m for deer, 0.9m for wild boar, 0.5m for coyote, and 0.2m for hare. When short pressing the P (6) / C (4) button, the value of the prey height will change by 0.1m every time, and the value of the effective range changes 5m, and when long pressing will change continuously. Press and hold the M (5) button to save the calibration and exit to the More submenu. Reset the system date and time Select the Time Setting option with the P (6) / C (4) button in the More submenu Time Setting Briefly press the M (5) button to enter the Time Setting interface. The order from left to right is year, month, day, hour and minute. And the time format is in 24-hours format. Switch among year, month, day, hour and minute with a short press of the M (5) button. The selected item will turn blue and two triangle icons will appear above and below the value. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com Select the correct value with a short press of the P (6) / C (4) button. Save settings and exit to the More submenu with a long press of the M (5) button. Show device information Select the System Information menu option with the P (6) / C (4) button in the More submenu. The relevant information of riflescope will be shown by a short System Information press of the M (5) button. This item allows the user to view the following information about the riflescope: the product model, GUI version, SYS Info, Boot version, FPGA, PN and SN number of the riflescope, Hardware version. Press and hold the M (5) button to return to the submenu. Reset to the Factory Settings Select the Factory Reset option with the P (6) / C (4) button Factory Reset in the More submenu. A prompt box will appear on the screen with a briefly press of the M (5) button. Short press the P (6) / C (4) button to select the option. The is to reset to the default, and the is to cancel and exit to All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com the More submenu. Confirm the selection with a short press of the M (5) button. Return Return to the main menu Select the Return option by P (6) / C (4) button. Short press the M (5) button to return to the main menu. 11 Photographing and Video Recording Saim SCH series thermal imager is equipped with a function for video recording and photographing observed images onto the built-in memory card. The files of images and videos will be named after the time, so it is recommended to reset the system time in the Main Menu More - Time Setting or to synchronize the system time and date in the Settings of the APP InfiRay Outdoor before using the camera and video function. For specific operations. Photographing Take a photo with a short press of the C (4) button in the home screen. A camera icon ( ) shows in the upper-right of the screen and the image will freeze for 0.5s when the function performs. Video recording Press and hold the C (4) button in the home screen to start the video recording. A tooltip showing the recording time in MM: SS
(minutes: seconds) format will All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com appear in the upper right corner of the display. The red dot in the tooltip flashes during recording. During recording, short press the C (4) button to take a photo also. Press and hold the C (4) button again to exit the recording when done. Video and picture files are stored in the built-in memory card after video Memory Access When the device is turned on and connected to a computer, it is recognized by the computer as a flash memory card, which is used to access the device's memory and make copies of pictures and videos. Turn on the device and connect it to the computer through the USB recording has been turned off. But the video will not be saved if you skip cable. the process and shut down the device suddenly instead. The photos and videos can be read on the computer via the USB cable. Note
- You can enter and work on the menu during video recording.
- The recording time is accumulated in minutes until the recording stops, that is, the time shows 60:00 after 59:59.
- The maximum duration of a video recording file is 10 minutes. When its more than 10 minutes, the video will be recorded onto a new file.
- The number of files is limited by the capacity of the device's built-in memory. Regularly monitor the amount of free memory in the built-in Double-click "my computer" on the desktop - double-click to open the device named "Infiray" - then click and open the device named "Internal Storage" to access memory. There are different folders named by time in memory. Recorded videos and photographs are saved in these folders in the format: IMG_HHMMSS_XXX. jpg (for photos) and VID_HHMMSS.mp4
(for video). HHMMSS- hour/minute/ second; XXX - three-digit common file counter for photos which is NOT reset. memory card, transferring footage and photos to other media to free up 12 Wi-Fi Function space on the memory card. The device is equipped with wireless communication with external All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com devices (computer, smartphone) via Wi-Fi. to estimate the approximate distance to an object, if its size is known. In the home screen, press and hold the M (5) button to enter the menu. In the home screen, press and hold the P (6) + M (5) buttons at the same Select the Wi-Fi option with the P (6) / C (4) button. time to enter the stadiametric ranging interface, and two measurement Briefly press of the M (5) button to turn Wi-Fi on. lines will appear on the upper and lower positions of the cursor. The device is recognized by an external device under the label Locate the object in the middle of the lines, then move the lines to locate Saim_xxxxx-xxxxxx, xxxxx-xxxxxx is the SN code of the device. the target between lines by the P (6) / C (4) button. Enter the password on an external device, and establish a connection. The approximate distance of the The initial password is 12345678. target is displayed on the left of the And then, the device can be controlled through the InfiRay Outdoor. screen. Set Wi-Fi name and password The Wi-Fi name and password of your device can be set in the APP. Click the "setting" icon in the APP to enter the setting interface. In the text box, enter and submit the name (SSID) and password of the Short press the P (6) + M (5) + C (4) buttons at the same time to switch the unit between cm/m and inch/yard. new Wi-Fi. It needs to restart the device to take the new name and password effect. 14 Range Notification Interface 13 Stadiametric Rangefinder Saim series is equipped with a stadiametric rangefinder, which allows you In the stadiametric rangefinder interface, long press P (6) + M (5) or M (5) button to enter the range notification interface. In the range notification interface, the prey type, height and effective All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com range is displayed on the bottom. The measurement lines become two Select the PIP option with the P (6) horizontal lines which cannot be moved.
/ C (4) button. The distance between two horizontal lines indicates the height mapped Briefly press of the M (5) button to to the display of the current ranging settings. turn PIP on/off. When the object is higher than the two horizontal lines distance, it When the PIP function is on, a means the object is in the effective range. small window will appear on the In the range notification interface, it is possible to operate the device, top of the display. such as, you can operate the prey settings in the main menu by long The image in the small window is a 2x magnified image centered by the pressing the M (55) button, referring to reticle center. the Section Main menu - More-
When the main image is enlarged through P (6) button, the PIP image Stadiametric Rangefinder Setting. will be enlarged 2 synchronously. Long press the P (6) + M (5) buttons again to exit from the range notification interface and back to the home screen. 15 PIP Function 16 Update and APP Technology In order to continuously improve the product performance and provide better user experience, the software program, as well as parameters and operating instruction of the device will be constantly updated. Users can go In the home screen, press and hold down the M (5) button to enter the to the official website (www.infirayoutdoor.com) to download and update. Main Menu. The Saim series support APP technology, and can be connected to a All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com smartphone or tablet PC via Wi-Fi for real-time image transmission, control finish the update. operations, and program updates. After finishing the update, the device will root. About InfiRay Outdoor You can download and install the InfiRay Outdoor app on www.infirayoutdoor.com or App Instructions for using InfiRay Outdoor can also be downloaded from the official website. 17 Technical Inspection store. Otherwise, you can download A technical inspection of the device is recommended before use. the app by scanning the QR code. Check the external appearance of the device (there should be no cracks When installation completed, open InfiRay Outdoor application. in the casing). If your device is already connected with a mobile device, please switch Check the condition of the lens and eyepiece (there should be no cracks, on the mobile data in mobile device. After connection, the update greasy spots, dirt or other deposits) detection is performed automatically with a prompt in the application. Check the condition of the rechargeable battery (this should be charged) Click 'Now' to download the updates or click 'Later' to update later. and the electrical contracts (there should be no presence of salts or InfiRay Outdoor will automatically store the last connected device. So, oxidation). if your device has not connected with your mobile device, but linked to InfiRay Outdoor before, the update prompt will appear if there is an update when turning on InfiRay Outdoor. You can download the update first via mobile Wi-Fi and then connect your device with mobile device to 18 Maintenance Maintenance should be carried out at least twice a year and consist of the following actions. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com Wipe the external surfaces of metal and plastic parts free of dust and dirt This device may be operated in all member states of the EU. with a cotton cloth. Silicone grease maybe used for this. Clean the electrical contacts of the battery and battery slot on the unit using a non-greasy organic solvent. Check the glass surfaces of the eyepiece and the lens. If necessary, remove dust and sand from the lenses (preferably using a non-contact method). Cleaning of the external surfaces of the optics should be done with substances designed especially for this purpose. FCC Statement FCC-ID: 2AYGT-256 Labeling requirements This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 19 Legal and Regulatory Information Information to the user Wireless transmitter module frequency range:
Any Changes or modifications not expressly approved by the party WLAN: 2.412-2.472GHz (For EU) responsible for compliance could void the user's authority to operate the Wireless transmitter module power<20dBm (only for EU) equipment. IRay Technology Co., Ltd. thus declares that the Saim Note: The manufacturer is not responsible for any radio or TV interference SCH50 complies with the directives 2014/53/EU and caused by unauthorized modifications to this equipment. Such 2011/65/EU. The full text of the EU declaration of modifications could void the users authority to operate the equipment. conformity as well as additional information are available Note: This equipment has been tested and found to comply with the limits at: www.infirayoutdoor.com. for a Class B digital device, pursuant to part 15 of the FCC Rules. These All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor Saim SCH Series Quick Start Guide 06/2021 www.infirayouordoor.com limits are designed to provide reasonable protection against harmful RF exposure requirements, a minimum separation distance of 0.5cm must interference in a residential installation. This equipment generates uses be maintained between the user's body and the handset, including the and can radiate radio frequency energy and, if not installed and used in antenna. Third-party belt-clips, holsters, and similar accessories used by accordance with the instructions, may cause harmful interference to radio this device should not contain any metallic components. Body accessories communications. However, there is no guarantee that interference will not that do not meet these requirements may not comply with RF exposure occur in a particular installation. If this equipment does cause harmful requirements and should be avoided. Use only the supplied or an interference to radio or television reception, which can be determined by approved antenna. We, IRay Technology Co., Ltd., hereby declare that this product was tested conforming to the applicable FCC rules under the most accurate measurement standards possible, and that all the necessary steps have been taken and are in force to assure that production units of the same equipment will continue to comply with the Commissions requirements. turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. Body-worn Operation This device was tested for typical body-support operations. To comply with All rights reserved and shall not be copied and distributed in any form without written permission
1 | Label | ID Label/Location Info | 168.19 KiB | May 25 2022 |
PN:252-2001-01-G SN:2522G-JH1001 UK Ds FCC ID:2avcr-256 fx aa = |
+ 096 06 08 ox 09 08 a oF oF 01 O0Z08 08 04 09 06 oF oF OF 01 00108 08 02 09 08 OF oF wi tuliutontutuntituituluatituntintunt on luutuituituituutiutiuituitinliatidtntiny
1 | Agency Letter | Cover Letter(s) | 27.38 KiB | May 25 2022 |
IRay Technology Co., Ltd. Date (2022-05-23) TUV SUD America Inc. 10 Centennial Drive Peabody, MA 01960, USA Dear Sir or Madam, We, IRay Technology Co., Ltd. 11GUIYANG STREET, YANTAI ECONOMY AND TECHNOLOGY, DEVELOPMENT DISTRICT, YANTAI SHANDONG P.R.CHINA hereby authorize Marlene Sealey of TUV SUD America, 10040 Mesa Rim Road, San Diego, CA, 92121 to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. Yours sincerely, Name: Peng Zhang Title: Quality Supervisor
1 | Confidentiality Letter | Cover Letter(s) | 77.88 KiB | May 25 2022 |
IRay Technology Co., Ltd. Date (2022-05-23) Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request FCC ID: 2AYGT-256 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commissions Rules, IRay Technology Co., Ltd. hereby requests permanent confidential treatment of information accompanying this application as outlined below:
Schematics BOM Block Diagrams Theory of Operation IRay Technology Co., Ltd. also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (can list up to 180) days:
Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Name: Peng Zhang Title: Quality Supervisor
1 | Test Setup Photos | Test Setup Photos | 548.29 KiB | May 25 2022 / November 20 2022 | delayed release |
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-05-25 | 2402 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2022-05-25
|
||||
1 | Applicant's complete, legal business name |
IRay Technology Co., Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0030296552
|
||||
1 | Physical Address |
11GUIYANG STREET, YANTAI ECONOMY AND TECHNOLOGY DEVELOPMENT DISTRICT, YANTAI SHANDONG P.R.CHINA
|
||||
1 |
11GUIYANG STREET, YANTAI ECONOMY AND TECHNOLOGY
|
|||||
1 |
YANTAI, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
a******@tuvsud.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AYGT
|
||||
1 | Equipment Product Code |
256
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
P**** Z****
|
||||
1 | Telephone Number |
18562********
|
||||
1 | Fax Number |
0535-********
|
||||
1 |
p******@iraytek.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 11/20/2022 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Geni Thermal Imaging Monocular | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips and holsters described in this filing and which contain no metallic component in the assembly. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. The highest reported SAR for head and body-worn accessory are 0.01 W/kg and 0.09 W/kg, respectively. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
TUV SUD Cert & Testing (China) Co., Ltd.
|
||||
1 | Name |
H****** Z******
|
||||
1 | Telephone Number |
86 75********
|
||||
1 |
h******@tuv-sud.cn
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2462.00000000 | 0.0251000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC