InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com IMPORTANT SAFETY INFORMATION User information on the disposal of electrical and electronic devices
(private households) Environmental influences Note: Never point the lens of the device directly at intense heat sources such as the sun or laser equipment. The objective lens and eyepiece can function as a burning glass and damage the interior components. Risk of swallowing Caution: Do not place this device in the hands of small children. Incorrect handling can cause small parts to come loose which may be swallowed. Safety instructions for use
- Do not expose the device to fire or high temperatures. The WEEE symbol on products and/or accompanying documents indicates that used electrical and electronic products must not be mixed with ordinary household waste. For proper treatment, recovery and recycling, take these products to the appropriate collection points where they will be accepted without charge. In some countries, it may also be possible to return these products to your local retailer when you purchase a corresponding new product. The proper disposal of this product serves to protect the environment and prevents possible harmful effects on human beings and their surroundings, which may arise as a result of incorrect
- The battery capacity decreases when operated in a cold ambient handling of waste. temperature. This is not a fault and occurs for technical reasons.
- Always store the device in its carrying bag in a dry, well-ventilated More detailed information on your nearest collection point is available from your local authority. In accordance with state legislation, penalties may be space. For prolonged storage, remove the batteries. imposed for the improper disposal of this type of waste.
- Do not expose your device to extreme temperatures lower than - 20C and higher than + 50C. For business customers within the European Union Please contact your dealer or supplier regarding the disposal of electrical
- The product shall only be connected to a USB Type C interface. and electronic devices. He will provide you with further information.
- If the device has been damaged or the battery is defective, send the device to our after-sales service for repair. Information on disposal in other countries outside of the European All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com Union This symbol is only applicable in the European Union. Please contact your local authority or dealer if you wish to dispose of this product and ask for a disposal option. Intended use The device is intended for displaying heat signatures during nature observation, remote hunting observations and for civil use. This device is not a toy for children. Use the device only as described in this instruction manual. The manufacturer and the dealer accept no liability for damages which arise due to non-intended or incorrect use. Function test
- Before use, please ensure that your device has no visible damage.
- Test to see if the device displays a clear, undisturbed image.
- Check that the settings for the thermal imaging camera are correct. See the notes in the section Operation. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com 1 Specifications Model MAH50 MAL38 MAL25 Detector Parameters Resolution, pixels 640512 384288 Pixel size, um NETD, mk Frame rate, Hz Optics Parameters 12 40 50 Objective lens, mm 50 38 25 Field of view (H x V), 8.87.0 /
7.05.3 /
10.67.9 /
degrees / m @ 100 m 15.412.3 12.39.2 18.413.8 Recommended magnification of the day scope, x E-zoom Detection range, m G1/G2: 1 - 5 G1/G2: 1 - 5 G1/G2/G3/G G3/G4: 6 - 10 G3/G4: 6 - 8 4:1 - 5 Attachment mode: 1 Monocular mode: 1/2/4
(Target size: 1.7m0.5m, 2597 1948 1298 P(n)=99%) Display Parameters Type Resolution, pixels Electrical Parameters OLED 1024768 Battery Built-in battery + Infiray battery Pack Max. battery life, h 4 + 7 4.5 + 7.5 USB Interface Physic Parameters Body material IP Rating Remote control Built-in memory, GB Type-C Magnesium Alloy IP67 Support 32 Aim point, MOA 1 Weight, g 515 505 1.5 460 Dimension, mm 1466273 1386271 1326268 Adapter Ring M520.75 The actual operating time depends on the intensity of using Wi-Fi, video recorder, laser rangefinder. Improvements may be made to the design and software of this product to enhance its useful features. Technical parameters of the device may be improved without prior notice of the customer. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com 2 Description 3 Features MATE series are all-new generation front attachment designed as the Quick monocular-attachment conversion infrared expansion device of the day light optics. Quick mounting and removal of attachment Different from the night vision device based on image enhancement, MATE 12m thermal imaging detector doesnt need external light source and isnt influenced by strong light 1024768 high resolution AMOLED display exposure. It can be used in the night or bad weather conditions such as No re-zeroing required and quick attached fog, rain, smog and can detect the objects through obstacles such as Magnesium alloy housing branch, tall grass, dense bushes and so on. MATE has a wide range Familiar precision application including night hunting, observation and terrain orientation, Capture/Video recording search and rescue operations. Support APP connecting via Wi-Fi Using the MATE Series Front Attachment includes several benefits over Wireless remote control night hunting with traditional optics or even the night vision devices. Four image modes White hot, Black hot, Red hot, Color Attaching the MATE Series to a traditional scope delivers the same Three scene modes Forest, Flatland, City creature comforts of shooting with day optics you are accustomed to, Monoculars digital zoom: 1, 2, 4 including your existing reticle and eye relief. The MATE Series Front Degree of protection IP67 Attachment even allows you to continue utilizing your riflescope's variable magnification All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com 4 Components and Controls 5 Menu / Status Bar Icons 1. Eyepiece 2. Eyepiece bayonet-type ring 3. Down button 4. Menu (M) button 5. Camera button 6. Up button 7. Lens focus knob 8. Lens cover 9. Objective lens 10. Power button 11. Microphone 12. Type-C port 13. Bottom picatinny rail 14. Clip-on universal adapter W B R C Image mode White hot Image mode Black hot Image mode Red hot Image mode Color Scene mode Forest Scene mode Flatland Scene mode City E-zoom (only for Monocular: x1, x2, x3, x4) Take a photo Display brightness Remote control Scene mode Image sharpness All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com Ultraclear Wi-Fi Video output Auto shutter calibration Battery power 6 Guidelines For Operation The Mate series has been designed for long-term use. To ensure Reticle type: G1/G2/G3/G4 sustainable performance, please adhere to the following:
Image calibration Range notification setting Before use make sure that you have mounted and adjusted the device according to the instructions of the section Operation. Store with the lens cap on in the carrying case. Pixels defect correction Switch off the device after use. Date setting Time setting Language setting Factory reset System information Attempts to disassemble or repair the device will void the warranty!
The device is designed for use in various operating temperatures. However, if it has been brought indoors from cold temperatures, do not turn it on for 2 to 3 hours. This will prevent external optical surfaces from condensation. To ensure reliable performance, it is recommended to carry out regular technical inspections of the unit. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com 7 Description of Controls Button Current Status Power off Power button Home screen Short Press
Standby the device Long Press Power on the device Standby Menu interface Home screen Wake up the device Power off the device Save and return to the upper interface Switch image mode Turn the range notification function on /off Up button Main menu / Shortcut menu interface Scroll up options
Zeroing / Pixels defect correction interface Home screen Move one pixel to the Up every time Move 10 pixels to the Up every time Shutter correction Background correction Down button Main menu / Shortcut menu interface Scroll down options
Zeroing / Pixels defect correction interface Move one pixel to the Down every time Move 10 pixels to the Down every time Range notification interface Loop toggles animal types Background correction Camera button Home screen Take a picture Video recording Zeroing / Pixels defect correction interface Move one pixel to the Left every time Move 10 pixels to the Left every time Menu (4) button Home screen Enter shortcut menu interface Enter Main Menu interface All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com Main menu / Shortcut menu interface Adjust parameter Save and exit to the home screen Zeroing / Pixel defect correction Move one pixel to the Right every time Move 10 pixels to the Right every time Up + Down buttons Zeroing interface
Pixels defect correction interface Camera + Menu (4) Zeroing interface buttons
Up + Menu (4) buttons
Pixels defect correction interface Home screen Save the zeroing position and set the coordinate as (0,0) Add / Delete defect pixels Save and exit to the home screen Switch between Attachment mode and Monocular mode 8 Installation MATE series can be used as a monocular or front attachment for day light scope. Original design allows the monocular to be quickly converted into attachment and vice versa. As a monocular Remove the Clip-on universal adapter (14) from MATE, then it can be used as a monocular. When used as a monocular, it needs to switch to the monocular mode with a long press of the Down (3) + Menu (4) buttons for 3s, in which the status bar at the top of the screen shows x1/ x2/ x4. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com Press and hold down the Down (3) + Menu (4) buttons for 3s to switch For a better observation experience, the Infiray Monocular (15) is between attachment mode and monocular mode. suggested to use (bought separately from the InfiRay website). Install the Infiray Monocular (15) on the eyepiece of the Mate by thread To mount it on a day device, please follow instructions as follows:
locking. Please make sure that the day device is zeroed before installation. In monocular mode, the Mate supports up to 4x electronic zoom, and Measure the outer diameter of the lens of your day scope (17). with the 4x24 Infiray Monocular (15), you will be able to obtain up to 16x Select an appropriate adapter with the internal thread M52*0.75 and an amplification. insert of the required diameter depending on the outer diameter of your day scopes objective lens. In the package, the complimentary universal adapter (14) with four inserts is suitable for the outer diameter from 56mm to 65 mm. If your day scope is out of this range, you need to buy it separately. As a front attachment MATE as an attachment is designed to use a day light scope both in the nighttime and daytime in inclement weather (fog, smog, rain etc.). When use as a front attachment, please ensure MATE is in attachment mode, in which the status bar at the top of the screen shows G1/G2/G3/G4. Install the insert (16) into the adapter (14) all the way in. Install firmly the adapter with the insert onto the objective lens of your day All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com scope (17). 9 Operation Snap the lever (20) from the original OPEN position to the CLOSE position. Check that the adapter firmly fits the objective lens. Open the lens cover (8). If you see there is a clearance, please:
Press and hold down the Power (10) button for 3s to power the device
- Loosen the locking screw (19) with the hex-nut wrench (S=2mm). on. Wait for 5s until thermal image appears on the display.
- Tighten the screw (18) with hex-nut wrench (S=4mm) with a clamping Lens Focus Adjustment: rotate the lens focus ring (7) to focus on the force necessary to ensure that the adapter fits tightly the objective object being observed. lens. Calibration:
- Tighten the locking screw (19).
- Shutter correctioncalibration the image with a short press of the Mount the Mate onto the adapter (14), and Down (3) button for shutter correction tighten the eyepiece bayonet-type ring (2)
- Background correction: long press the Down (3) buttonthe counterclockwise to lock Mate. display will appear the prompt for Cover lens during calibration After installation, if the center of Mates display iconthen close the lens cover (8) to complete background is not aligned with the center of your day scope:
correction.
- Loosen the locking screw (21) with the hex-nut wrench (S=4mm). Image mode Settings: short press Up (6) button to change the image
- Adjust the angle of the Mate to the appropriate position to align with mode from White hot / Black hot / Red hot / Color one by one. the center of your day scope. Other image settings: short press the Menu (4) button to enter the
- Tighten the locking screw (21). Shortcut Menu interface, to set electronic zoom (only for Monocular All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com mode) / Brightness / Scene mode / Sharpness level. In the home screen, press and hold down Menu (4) button to enter the Power Off: long press Power (10) button for 3s to power off the Mate. Main Menu interface. Standby Mode: Press the Power (10) button briefly to standby the Press the Up (6) / Down (3) button device for power saving. And press the Power (10) button again to to select the Zeroing Profile option wake it up. 10 Zeroing (only for Attachment mode) When Mate is installed on the day scope as an infrared extension component, if the reticle of the day scope is not in the center of the infrared image, the image zeroing function can be used to shift the infrared image to ensure the position consistency between the day scope image and the infrared image. Please finish the calibration of the day scope before mounting MATE. Install Mate on the day scope and repeat the calibration steps above. Then aiming at the target at 100 meters and shoot. Measure the horizontal distance and vertical distance between the bullet hitting point
) and select a zeroing profile with a short press of the Menu (4) button. Then select the Zeroing option
) and short press the Menu (4) button to enter the Zeroing interface. In the zeroing interface, short press the Up / Down / Camera / Menu button briefly to move the position of infrared image and long press to achieve quick shift until the target on the infrared image is consistency with the reticle center of the day scope. When the zeroing is done, long press Menu (4) + Camera (5) buttons to save and exit the zeroing interface, or hold down Up (6) + Down (3) buttons for 3sSave the zeroing position and set the coordinate as (0,0) and the aiming point afterwards. and exit to the home screen. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com 11 Shortcut Menu 12 Main Menu In the home screen, press the Menu (4) button briefly to enter the In the home screen, press and hold down the Menu (4) button for 3 shortcut menu interface. The functions are as followings:
seconds to enter the main Menu interface.
- Electronic zoom (only for Monocular mode): short press the Menu (4) button to E-zoom the image from x1 to x4.
- Screen brightness: short press the Menu (4) button to switch In the main Menu, press the Up (6) / Down (3) button briefly to switch the the screen brightness from level 1 to level 4. menu option.
- Scene mode: short press the Menu (4) button to switch the scene mode among Forest, Flatland and City.
Image sharpness: short press the Menu (4) button to switch the Press the Menu (4) button briefly to adjust the parameters of present option or enter to the submenu. Press and hold down Menu (4) button for 3 seconds to exit to the home image sharpness from level 1 to level 4. screen. Press the Up (6) / Down (3) button briefly to switch the function options. Press and hold the Menu (4) button to exit to the home screen or exit automatically if no operation within 5s. Press the Power (10) button briefly to save and exit to the upper interface. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com Main Menu function description Turn Ultraclear mode on/off Press and hold down the Menu (4) button to enter the Main Menu. Ultraclear Select the Ultraclear option with the Up (6) / Down (3) button. Turn the Ultraclear mode on /off with a short press of Menu (4) button, along with the sound of shutter calibration. The icon will be displayed on the bottom status bar when the Ultraclear mode is on. Ultraclear Mode will show more image details under the cloudy, rainy, foggy and other harsh weather conditions. Turn Wi-Fi function on/off Press and hold down the Menu (4) button to enter the Main Menu. Wi-Fi Select the Wi-Fi option with the Up (6) / Down (3) button. Turn the Wi-Fi function on /off with a short press of Menu (4) button. The icon will be displayed on the bottom status bar when the Wi-Fi is on. When Wi-Fi is on, it can be connected with the mobile phone APP. Turn video output on/off Video Output Press and hold down the Menu (4) button to enter the Main Menu. Select the Video Output option with the Up (6) / Down (3) button. Briefly press of the Menu (4) button to turn video output on/off. The icon will be displayed on the bottom status bar when the video output function is on. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com Video output function enable connectivity with an eternal display or recording device. Turn the Auto shutter calibration on/off Auto shutter calibration Press and hold down the Menu (4) button to enter the Main Menu. Select the Auto shutter calibration option with the Up (6) / Down (3) button. Briefly press of the Menu (4) button to set the Auto shutter calibration mode on / off. The icon will be displayed on the bottom status bar when the Auto shutter calibration is on. When the Auto shutter calibration is on, the shutter will automatically when the Image quality deteriorates. Select the Zeroing Profile (only for Attachment mode) Press and hold down the Menu (4) button to enter the Main Menu. Select the Zeroing Profile option with the Up (6) / Down (3) button. There are four types for selection: G1/G2/G3/G4. Zeroing Profile For MAH50:
- G1/G2: Recommended magnification of the day light optics for 1x-5x;
- G3/G4: Recommended magnification of the day light optics for 6x-10x;
For MAL38:
- G1/G2: Recommended magnification of the day light optics for 1x-5x;
- G3/G4: Recommended magnification of the day light optics for 6x-8x;
For MAL25:
All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com
- G1/G2/G3/G4: Recommended magnification of the day light optics for 1x-5x;
Briefly press of the Menu (4) button to Switch and select one zeroing type. Zeroing (only for Attachment mode) Press and hold down the Menu (4) button to enter the Main Menu. Zeroing Select the Zeroing option with the Up (6) / Down (3) button. Briefly press of the Menu (4) button to enter the Zeroing interface. In the zeroing interface, short press the Up / Down / Camera / Menu button briefly to move the position of infrared image. For the details, please refer to Section 10 Zeroing. Range notification settings Press and hold down the Menu (4) button to enter the Main Menu. Select the Range Notification option with the Up (6) / Down (3) button. Briefly press of the Menu (4) button to enter the Range Notification setting Range Notification interface. There are five prey type for selection, including hare (
), coyote (
), wild boar (
), deer (
), and custom (
). Each prey type corresponds to a default height with a default effective distance of 100m. Switch the type option with the Up (6) / Down (3) button, and short press the Menu (4) button to active option. The first four animal types can only set the distance parameter with the Up (6) / Down (3) button. When setting is All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com complete, press the Menu (4) button briefly to return to the range notification interface. The last one is custom, which can set the height and distance parameters. Press the Menu (4) button briefly to switch among the selection of the height, distance and returning to the range notification interface. Press and hold down the Menu (4) button to exit to the home screen. Pixels Defect Correction Press and hold down the Menu (4) button to enter the Main Menu. Select the Pixels Defect Correction option with the Up (6) / Down (3) button. Briefly press of the Menu (4) button to enter the Pixels Defect Correction Interface. Pixels Defect Correction A reticle will appear in the center of the screen and the number of corrected defect pixels will display at the bottom of the screen. And then, moving the reticle to select the Defect Pixels by pressing the Up /
Down / Camera / Menu button. After selecting the Defect Pixels, press and hold the Up (6) + Down (3) buttons at the same time to correct the blind pixels. When the Add message appears on the bottom of the screen for a short time, the correction is successful. At the same position, press and hold the Up (6) + Down (3) buttons again to cancel the correction with the Del massage appearing for a short time. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com The number of the defect pixels changes each time adding or deleting pixels correction. Repeat the above operations to continue selecting defect pixels. When the correction is done, press and hold the Camera (5) + Menu (4) buttons until display shows Do you want to save these settings? and Yes and No options. Select Yes to save and exit, or select No to cancel saving and exit. Switch the selection with the Up (6) / Down (3) button, and confirm your selection with the Menu (4) button. Date setting Press and hold down the Menu (4) button to enter the Main Menu. Select the Date option with the Up (6) / Down (3) button. The date is displayed Date setting in yy/mm/dd format. Briefly press of the Menu (4) button to switch among Year, Month and Day option, then press Up (6) / Down (3) button to set the date. When the Date setting is done, press and hold Menu (4) button to exit the Date setting interface. Time setting Time setting Press and hold down the Menu (4) button to enter the Main Menu. Select the Time option with the Up (6) / Down (3) button. The time is displayed in 24-hours format. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com Briefly press of the Menu (4) button to switch between hour and minute option, then press the Up (6) / Down (3) button to set the time. When the Time setting is done, press and hold Menu (4) button to exit the Time setting interface. Language setting Press and hold down the Menu (4) button to enter the Main Menu. Select the Language option with the Up (6) / Down (3) button. Language Enter the Language submenu with a short press of the Menu (4) button. Press the Up (6) / Down (3) button to switch between English and German. Confirm your selection with a short press of the Menu (4) button. Return to main menu interface will happen automatically when the language is selected. Factory Reset Reset to the factory settings Press and hold down the Menu (4) button to enter the Main Menu. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com Select the Factory Reset option with the Up (6) / Down (3) button. Press the Menu (4) button to enter the Factory Rest interface. Press Up (6) / Down (3) button to select Yes or No. When Yes is selected, MATE will restore the factory settings and restart. When No is selected, it will return to the main menu interface. System Information Press and hold down the Menu (4) button to enter the Main Menu. Info Select the Info option with the Up (6) / Down (3) button. Press the Menu (4) button to show the relevant information. This item allows the user to view the following information: the device model, GUI version, PN and SN number, Wi-Fi version, and FPGA version. Press and hold Menu (4) button to exit the Info interface All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com 13 Photography and Video recording A recording timer displays on the top of the screen. the time format is MM: SS (minute: second). MATE has built-in 32GB storage space for photography and video recording. During recording, it is still possible to take a photo with a short press of The files of images and videos will be named by time, so it is recommended the Camera (5) button. to set the time in the Main Menu or synchronize the time in the Settings of Also, you can enter and navigate the menu function during video the Infiray Outdoor APP before using the photography and video recording recording function. Photography Press the Camera (5) button in the home screen to take a photo. The screen freezes for 0.5s, and a Press and hold down the Camera
(5) button to stop and save the recording. The video and photo are saved in the built-in storage space. photo icon appears on the screen. Tips:
Photographs are saved in a built-in
- Recorded photos and videos are saved in built-in memory card of the storage space. Video recording device in the format IMG_HHMMSS_XXX.jpg (for photos) and VID_HHMMSS_XXX.mp4 (for videos). HHMMSS - Hour/Minute/Second XXX - three-digit counter (for videos and photos). In the home screen, press and hold down the Camera (5) button to start
- The counter used for the names of multimedia files cant be reset. a video recording.
If a file is deleted from the list, its number is not taken by the other file. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com Caution:
Internal Storage to access built-in memory.
- The maximum duration of a recorded video file is 5 minutes. After this There are different folders named by time in the storage. time expires, the video is recorded to a new file automatically. Recorded photos and videos in that day are saved in the folders
- The number of the recorded files is limited by the capacity of the internal Select desired files or folders to copy or delete. memory.
- Check the available space of the built-in storage card regularly and move the footage to other storage media to free up the memory card 14 Range Notification Function space. Range notification function is used to determine if the animal is within your Graphic data (status bar, icons and menu) in the recorded video and photo range. files are not displayed. Memory Access When the device is turned on and connected to a computer, it is recognized by the computer as a flash memory card, which is used to access the device's memory and make copies of pictures and videos. Turn on the riflescope and connect it with the computer via Type-C cable. Double click my computer on the desktop - double click to open the device named InfiRay - double click and open the device named In the home screen, press and hold down the Up (6) button for 3s to enter the range notification interface. You will see the following on the display: Two measurement bars, Distance, Animal type, Animal height. There are five pre-set reference objects:
- Hare - distance 100m, height 0.2m
- Wolf - distance 100m, height 0.4m
- Wild boar - distance 100m, height 0.9m
- Deer - distance 100m, height 1.7m All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com
- Custom - distance 100m, height 1.0m Turn Wi-Fi function on /off with a short press of Menu (4) button. Aiming at the target, if the target Retrieve the Wi-Fi signal named "XXXXX_xxxxxxx" with an external animal is within the measurement device such as smart phone, whch XXXXX represents the model and bars, it indicates the animal is within the range you set. xxxxxxx represents the SN code of the device. Select the Wi-Fi, and enter the password on the mobile device to set up At shooting range notification the connection. The initial password is 12345678. interface, press Down (3) button When Wi-Fi is successfully connected, you can control the device via to change the target type. InfiRay Outdoor APP. You can change the default setting (including the animal distance or animal height) in the main menu. Exit the range notification interface with a long press of the Up (6) button. 15 WIFI function Mate series has a built-in Wi-Fi module, which enables the device to connect wirelessly to external devices such as smart phones. Press and hold down the Menu (4) button to enter the Main Menu. Set the Wi-Fi name and password The Mate series allows users to change the name and password of device Wi-Fi in the InfiRay Outdoor APP After connected with the mobile device, find and click the "Setting"
icon in the InfiRay Outdoor to enter the setting interface. In the text box, enter and submit the new name (SSID) and password of the Wi-Fi. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com It needs to reboot the device to take the new name and password effect. The fixture is suitable for the most day scope with barrel diameter of Otherwise, clicking the synchronize time option in the setting interface 30mm. can synchronize the time on the Mate with the mobile device. After installation, insert the data cable (24) to Type-C port (12) of Mate Note and the battery pack.
- When restored factory settings, the Wi-Fi name, password, and system Once connected, the battery pack will automatically charge the Mate. time are restored to the factory default settings. Press the Power button (23) of the battery pack to check the remaining power of the battery pack. For details, please refer to the manual of the IBP-4 InfiRay battery pack. 16 Battery Pack Installation Mate series is equipped with a professional power bank - IBP-4 InfiRay battery pack (22) in the package, which is impact-resistant, waterproof and lightweight, making it perfect for outdoor use. Secure the IBP-4 InfiRay battery pack (22) to the smaller ring of the adapter fixture (24) in the package, and tighten the screws (26) with the hex-nut wrench (S=2mm). Install the adapter fixture (24) with IBP-4 InfiRay battery pack (22) on Safety Regulation your day scope (17). Close the lever (25) on the adapter fixture to lock Please use standard charger to prevent the battery pack from damage. the fixture. It is prohibited to expose the battery pack in the high temperature All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com environment more than 60C. Thread the two magic straps (29) into the base (28) and attach the It is prohibited to put the battery pack into fire and burns. module onto the suitable position of your gun. The battery capacity decreases when operated in a cold ambient Then you can control the Mate remotely. temperature. This is not a fault and occurs for technical reasons. The remote control has a built-in battery that can be used continuously 17 Remote Control for more than 30 days. If the battery runs out, reattach the button module (27) to the Mate and charge it automatically via the pogo pin. 18 Technical Inspection A technical inspection of the device is recommended before use. Check the external appearance of the device (there should be no cracks in the casing). MATE button module can be removed from the Mate and installed at any Check the condition of the lens and eyepiece (there should be no cracks, position of the gun with its own accessory as a remote control. greasy spots, dirt or other deposits) Remove the button module (27) from Mate unite. Check the condition of the rechargeable battery (this should be charged) Install the button module (27) on the base (28) provided with the and the electrical contracts (there should be no presence of salts or package. oxidation). All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com 19 Maintenance with substances designed especially for this purpose. Maintenance should be carried out at least twice a year and consist of the following actions. 20 General Trouble Shooting Wipe the external surfaces of metal and plastic parts free of dust and dirt with a cotton cloth. Silicone grease maybe used for this. Clean the electrical contacts of the battery and battery slot on the unit using a non-greasy organic solvent. The table lists all the problems that may occur when operating the device. Carry out the recommended checks and troubleshooting steps in the order shown in the table. If there are defects that are not listed in the table or it is impossible to repair yourself, please contact with us as soon as possible. Check the glass surfaces of the eyepiece and the lens. If necessary, Private demolition is strictly prohibited. remove dust and sand from the lenses (preferably using a non-contact method). Cleaning of the external surfaces of the optics should be done Trouble description Probable reason Trouble shooting Fail to start up Battery is low power Fail to work with the remote control Remote battery is low power Charge your MATE or use the Infiray Battery Pack Attach the remote to the MATE's body and charge it via the pogo pin Image is fuzzy, not clear, with vertical stripes and uneven background No calibration for a long time Perform the shutter calibration or background calibration Image is too dark Low screen brightness Adjust the screen brightness All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com Blurred image with clear GUI The objective lens is not focused There is dust or condensate on the interior or exterior optical surfaces of the lens Adjust the focus ring of the objective lens until the image becomes clear Wipe off the outside optical surfaces with a soft cotton cloth. Let it dry by leaving it in a warm environment for 4 hours The video output function is not turned on Turn the video output function in the Main Menu No analog video output Data cable doesnt support data transmission Replace a new data cable Point of impact does not match the aiming point Zeroing needs to be done Do zeroing according to the section 12 Zeroing profile is incorrect Check the zeroing profile setting 21 Update and InfiRay Outdoor The design of the riflescope provides the software update option. Updating is possible via the InfiRay Outdoor application. Also, it is feasible to download and update software from the official website. Mate series thermal imaging attachment support InfiRay Outdoor technology, which allows you to transmit the image from the thermal imager About InfiRay Outdoor to the smartphone or tablet via Wi-Fi in real time mode. You can get InfiRay Outdoor application in the official website, or You can find detailed instructions on InfiRay Outdoor in the separate search InfiRay Outdoor in App store, or scan the QR code to download brochure at the site www.infirayoutdoorcom. InfiRay Outdoor APP. All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com When installation completed, open InfiRay Outdoor APP. 22 Legal and Regulatory Information If your device is already connected Wireless transmitter module frequency range:
with mobile device, please switch on WIFI 2.4G: 2412-2472MHz (For EU) the mobile data in mobile device. After connection, the update detection Wireless transmitter module power < 20dBm (only for EU) is performed automatically with a prompt in the application. Click Now to download the updates or click Later to update later. InfiRay Outdoor will automatically store the last connected device. So, if your device is not connected with your mobile device, but linked to InfiRay Outdoor before, the update prompt will appear if there is an update when turning on InfiRay Outdoor. You can download the update first via mobile Wi-Fi and then connect Mate with mobile device to finish the update. After finishing the update, the device will root. Instructions for using InfiRay Outdoor can also be downloaded from the official website. IRay Technology Co., Ltd. thus declares that the Mate series complies with the directives 2014/53/EU and 2011/65/EU. The full text of the EU declaration of conformity as well as additional information are available at: www.infirayoutdoor.com. This device may be operated in all member states of the EU. FCC Statement FCC ID: 2AYGT-2N-00 Labeling requirements This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful All rights reserved and shall not be copied and distributed in any form without written permission InfiRay Outdoor MATE Series User Manual www.infirayouordoor.com interference, and (2) this device must accept any interference received, communications. Operation of this equipment in a residential area is likely including interference that may cause undesired operation. to cause harmful interference in which case the user will be required to Information to the user correct the interference at his own expense. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. equipment. Note: The manufacturer is not responsible for any radio or TV interference Body-worn Operation caused by unauthorized modifications to this equipment. This device was tested for typical body-support operations. To comply Such modifications could void the users authority to operate the with RF exposure requirements, a minimum separation distance of 0mm equipment. must be maintained between the user's body and the handset, including the antenna. Third-party belt-clips, holsters, and similar Note: This equipment has been tested and found to comply with the limits accessories used by this device should not contain any metallic for a Class A digital device, pursuant to part 15 of the FCC Rules. These components. Body accessories that do not meet these requirements limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved. The maximum results of Specific Absorption Rate (SAR) found during testing for MAH50 are 0.524W/kg All rights reserved and shall not be copied and distributed in any form without written permission