Natural Gas Solutions 100G Datalogging FN ERT Module Installation Guide - Remote Mount TDC-0824-003 Identification 100G Datalogging FN ERT Module Installation Guide - Remote Mount 01/10/2011 TDC-0824-003 100G Remote Mount ERT Module part numbers: ERG-5000-501, ERG-5000-502, ERG-5000-503 100G Datalogging Remote Mount ERT Module: ERG-5002-501, ERG-5002-502, ERG-5002-503, ERG-5002-505 100G Datalogging FN Remote Mount ERT Module: ERG-5003-501, ERG-5003-502, ERG-5003-503, ERG-5003-505 Copyright 2009 - 2010 - 2011 Itron, Inc. All rights reserved. Confidentiality Notice The information contained herein is proprietary and confidential and is provided subject to the condition that (i) it is held in confidence except to the extent required otherwise by law and (ii) is issued only for the purposes described herein. Any third party given access to this information is similarly bound in writing. Trademark Notice Itron is a registered trademark of Itron, Inc. All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies. Applicable Patents U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700 Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118 Compliance Statement This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions:
This device may not cause harmful interference. This device must accept any interference that may cause undesirable operation. This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels. Compliance Statement This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Dclaration de conformit Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Transportation Classification The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the 100G Datalogging FN remote ERT module is considered an operating transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation. Modifications and Repairs To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification will void the user's authority to operate the equipment. Meter Installation/Removal In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron. Warning Follow these procedures to avoid injury to yourself or others:
The lithium battery may cause a fire or chemical burn if it is not disposed of properly. Do not recharge, disassemble, heat above 100 Celsius (212 Fahrenheit), crush, expose to water, or incinerate the lithium battery. Fire, explosion, and severe burn hazard. Keep the lithium battery away from children. Replace the lithium battery only with batteries meeting Itron specifications. Any other battery may cause a fire or explosion. Warning Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by others might void any maintenance contract with your company. Unauthorized service personnel might also be subject to shock hazard on some Itron equipment if removal of protective covers is attempted. Warning To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. Warning Substitution of components may impair intrinsic safety. Suggestions If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com If you have questions or comments about the software or hardware product, contact Itron Technical Support:
Contact Internet: www.itron.com E-mail: support@itron.com Phone: 1 877 487 6602 Contents Before You Begin .......................................................................................................... v Document Purpose .............................................................................................................................. v Chapter 1 100G Datalogging FN Remote ERT Module .............................................. 1 Transmission Modes ........................................................................................................................... 1 Specifications ...................................................................................................................................... 2 Related Documents .................................................................................................................. 2 100G Datalogging FN Remote ERT Module Meter Compatibility List ................................................ 3 Installation Prerequisites ..................................................................................................................... 5 Chapter 2 Mounting the 100G Datalogging FN Remote ERT Module ....................... 6 Installation Options .............................................................................................................................. 6 Mounting Screw Specifications ................................................................................................. 6 Mounting Installation Considerations .................................................................................................. 7 Mounting the Remote ERT Module on a Pipe .......................................................................... 8 Mounting the ERT Module on a Wall or Other Flat Vertical Surface ............................ 14 Chapter 3 Rotary Meter Installation .......................................................................... 16 Required Installation Materials Available from Itron .......................................................................... 17 Programming the Remote ERT Module for Dresser ROOTS Rotary Meters .................................. 19 B3, LMMA & S3A CTR/TC Meter Drive Rates for Remote ERT Module Programming ................... 20 Installing the Remote ERT Module to the Elster American Meter RPM Series Rotary Meter .......... 21 Mounting the 100G Datalogging FN Remote Mount ERT Module .................................................... 27 Installing the Remote ERT Module to the Romet Electronically Compensated Meter (ECM2) ...... 27 Connecting the Remote ERT Module to the Romet ECM2 Meter ................................................... 28 Romet ECM2 Mounting Requirement.............................................................................................. 28 Programming the 100G Datalogging FN Remote ERT Module ........................................................ 31 Chapter 4 Electronic Volume Corrector and Instrument Installation ..................... 33 Installation Prerequisites ................................................................................................................... 34 Installation Overview ......................................................................................................................... 34 Programming the Mercury Instrument ............................................................................................... 35 Code Settings.......................................................................................................................... 35 Wiring the ERT Module to the Instrument ......................................................................................... 36 Wiring Dual ERT Modules to a Mercury Instrument .......................................................................... 38 Wiring the Remote ERT Module to the Mercury TCI ........................................................................ 40 Connecting the 100G Datalogging FN Remote Mount ERT Module to the IMC/W2 or MC2 Cable . 43 Installing the ERT Module to the Dresser ROOTS Micro Corrector (IMC/W2 or MC2) .................. 46 Programming the 100G Datalogging FN Remote ERT Module ........................................................ 50 TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount Proprietary and Confidential iii Contents Chapter 5 Diaphragm Meter Installation ................................................................... 52 Tools and Materials Supplied By You ............................................................................................... 52 Materials Available from Itron ............................................................................................................ 53 Replacement Gaskets ............................................................................................................. 53 Installing the 100G Datalogging FN Remote ERT Module ............................................................... 54 Installing 100G Datalogging FN Remote ERT Module Encoders ..................................................... 55 Index Cover Installation Required Materials ........................................................................... 60 Programming the 100G Datalogging FN Remote ERT Module ........................................................ 64 Chapter 6 DATTUS Meter Installation ....................................................................... 66 Installation Prerequisites ................................................................................................................... 66 Programming the DATTUS Meter ..................................................................................................... 66 Installation Overview ............................................................................................................... 66 Installing the Remote ERT Module to Itron DATTUS Meters ....................................... 67 Mounting the 100G Datalogging FN Remote ERT Module .......................................... 70 Programming the 100G Datalogging FN Remote ERT Module ................................... 71 Chapter 7 Sensus Sonix Meter Installation .............................................................. 73 Programming the Sensus Sonix Meter ............................................................................................. 73 Adjusting the Pulse Output for Sonix 600 and 880 Meters ..................................................... 73 Installing the 100G Datalogging FN Remote ERT Module with Sensus Sonix Meters ..................... 74 Sensus Sonix2000 Pulse Output Wiring ................................................................................. 74 Direct Mounting the Remote ERT Module to the Sonix Meter ................................................ 75 Connecting the Remote ERT Module to a Sensus Sonix 600 or 880 Meter .......................... 76 Programming the 100G Datalogging FN Remote ERT Module .............................................. 77 Index ............................................................................................................................. 79 TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount iv Proprietary and Confidential Before You Begin Before You Begin The following documentation conventions are used:
Caution A Caution warns the user that failure to heed the information in the note could result in loss of data. Be sure to carefully read a Caution note and follow the advice/instructions. Warning A Warning alerts you about potential physical harm to the user or hardware. It is critical that you pay strict attention to Warning notes, read the information carefully, and follow the advice/instructions. Tip A Note provides the user with extra hints to make a task easier to perform or a concept easier to understand. Note A Note supplies generic information to the user. The user could ignore the information and continue a task without suffering any adverse consequences. Document Purpose This installation guide provides step-by-step instructions for installing the 100G Series remote gas ERT module on a wide variety of meters and instruments. This installation guide refers to the 100G series remote ERT module as the 100G Datalogging FN remote ERT module. Mechanical and electrical installation procedures are similar for all modules. 100G Datalogging FN remote ERT module compatible meters and instruments are listed in the 100G Datalogging FN Remote ERT Module Meter Compatibility List on page 3. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount v Proprietary and Confidential C H A P T E R 1 100G Datalogging FN ERT Module Itron 100G series remote ERT modules are radio-frequency (RF) devices designed to transmit meter data to an RF meter reading device within transmission distance of the remote ERT module. The 100G remote gas ERT module was designed with a higher output power than earlier Itron remote gas ERT modules to achieve an increased RF transmission distance. The 100G series remote gas ERT modules have greater output power to meet Itron mobile and fixed network requirements. The first 100G remote gas ERT module offered high transmit power capability which increased operational efficiency and reduced infrastructure costs. The 100G Datalogging remote gas ERT module offers high transmit power with data logging capability (time-stamped hourly interval data) for both mobile and fixed network applications. Itron's 100G Datalogging Fixed Network
(DLN) remote gas ERT module adds improved network performance through even higher transmit power, accomplished using increased antenna efficiency and more robust optimized messaging structures. The 100G Datalogging FN remote ERT module features tilt-tamper and cut cable-tamper reporting and security seals to indicate physical tampering and minimize theft. Cut cable is reported when the cable is cut or disconnected from the meter, instrument, or endpoint. 100G Datalogging FN remote ERT module circuitry senses an electrical current break to report a cut cable tamper event. Transmission Modes The 100G Datalogging FN remote ERT module can be set to transmit in Fixed Network, Mobile and Handheld, or Hard to Read Mobile and Handheld Mode. Fixed Network Mode. The 100G Datalogging FN remote gas ERT transmits a high-powered network interval message (NIM) RF message every five minutes. Output power in this mode is 500 milliwatts or
+27 dBm. Interspersed in the high power NIM, the 100G Datalogging FN remote ERT module transmits a medium power RF message at 10 milliwatts or +10 dBm; expected battery life is 20 years. Mobile High Power Mode. The 100G series remote gas ERT transmits a high-powered RF message every 60 seconds. Output power in this mode is 250 milliwatts or +24dbm; expected battery life is 20 years. Mobile and Handheld Mode. The 100G series remote gas ERT transmits a medium-powered RF message every 15 seconds. Output power in this mode is 10 milliwatts or +10dBm; expected battery life is 20 years.
(Optional) Hard to Read Mobile and Handheld Mode. The 100G series remote FN gas module transmits a high-powered RF message every 30 seconds. Output power in this mode is 250 milliwatts or
+24dBm; expected battery life decreases to 15 years in this mode. The Hard to Read Mobile and Handheld Mode should only be used for exceptionally hard-to-read applications (such as meters installed on roof tops or in sub-basements). An FCC license is not required to read 100G series remote gas ERT modules. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount Proprietary and Confidential 1 100G Datalogging FN ERT Module Specifications The functional and operational specifications for the 100G Datalogging FN remote ERT module are listed below. Functional Specifications Description Power source Tamper detection FCC compliance Industry Canada compliance Intrinsically safe per Product identification Construction materials Two "A" cell lithium batteries Tilt tamper and cut cable tamper Part 15 certified RSS-210 certified UL Class I, Division 1, Groups C and D Numeric and bar-coded ERT module type and serial number Gray polycarbonate housing and back plate with encapsulated electronics Operational Specifications Description Operating temperatures Operating humidity Program frequency Transmit frequency Data integrity
-40 to 158 F (-40 to +70 C) 5 to 95 percent relative humidity 908 MHz Spread spectrum 908 to 924 MHz ISM band Verified in every data message Related Documents Document Title Document Part Number Gas Endpoint Meter Compatibility List Gas Endpoint Ordering Guide PUB-0117-002 PUB-0117-001 100G Datalogging Specification Sheet Publication 100941SP-XX Endpoint Link Programming Guide Field Deployment Manager Endpoint Tools Mobile Application Guide TDC-0744*
TDC-0934*
Field Deployment Manager Field Representative's Guide TDC-0936*
*The last three digits of the user and installation guides represent the document's revision level. The revision level is subject to change without notice. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 2 Proprietary and Confidential 100G Datalogging FN ERT Module 100G Datalogging FN Remote ERT Module Meter Compatibility List This table lists meters compatible with the 100G Datalogging FN remote ERT module. Due to continuous research, product improvements, and enhancements Itron reserves the right to change this list without notice. Model Description Class Comments ERT Module Type Meter Elster/American/
Canadian Sensus/Invensys Itron/Actaris/
Schlumberger/
Sprague Itron/Actaris/
Schlumberger/
Sprague Itron/Actaris/
Schlumberger/
Sprague Itron/Actaris/
Schlumberger/
Sprague 10 Metric (10B) Iron case Residential 2.5' cable with encoder Commercial 12" lead wires Sonix 12,16,25,57, 600,880,2000 Pulser Metric Cubic foot National/ Lancaster All meters Where direct mount is not compatible Residential 2.5' cable with encoder Itron/Actaris Schlumberger/ Sprague 1A Where direct mount is not compatible Residential 2.5' cable with encoder Metris 250 Straight Face meter Residential 2.5' cable with encoder 305 400
#2 flat-face meter
#3 flat-face meter 2.5' cable with encoder 2.5' cable with encoder 675, 1000 Front mount index Commercial Elster American TC and STD CTR American RPM series rotary meters including TC and non-TC. Commercial Romet STD CTR RM series Commercial 600 through 56000 TC 2000 through 23000 2.5' cable with encoder Also requires thicker gasket for magnet hub to clear index box. 1-hole gasket: FAB-0014-001 2-hole gasket: FAB-0014-002 4-hole gasket: FAB-0014-003 Meter must have a factory installed pulser with connector output. Purchase endpoint from Itron and correct cable interface from appropriate meter manufacturer. Meter must have a factory installed pulser with connector output. Purchase endpoint from Itron and correct cable interface from appropriate meter manufacturer. ERT Module Part Number ERG-5000-501 ERG-5002-501 ERG-5003-501 ERG-5000-503 ERG-5002-503 ERG-5003-503 ERG-5000-501 ERG-5002-501 ERG-5003-501 ERG-5000-501 ERG-5002-501 ERG-5003-501 ERG-5000-501 ERG-5002-501 ERG-5003-501 ERG-5000-501 ERG-5002-501 ERG-5003-501 ERG-5000-501 ERG-5002-501 ERG-5003-501 ERG-5000-501 ERG-5002-501 ERG-5003-501 100G Remote 100G Datalogging Remote 100G Datalogging FN Remote 100G Remote 100G Datalogging Remote 100G Datalogging FN Remote 100G Remote 100G Datalogging Remote 100G Datalogging FN Remote 100G Remote 100G Datalogging Remote 100G Datalogging FN Remote 100G Remote 100G Datalogging Remote 100G Datalogging FN Remote 100G Remote 100G Datalogging Remote 100G Datalogging FN Remote 100G Remote 100G Datalogging Remote 100G Datalogging FN Remote 100G Remote 100G Datalogging Remote 100G Datalogging FN Remote 100G Remote (12' lead wires) 100G Datalogging Remote
(12" lead wires) 100G Datalogging FN Remote (12" lead wires) ERG-5000-503 ERG-5002-503 ERG-5003-503 100G Remote (12' lead wires) 100G Datalogging Remote
(12" lead wires) 100G Datalogging FN Remote (12" lead wires) ERG-5000-503 ERG-5002-503 ERG-5003-503 TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 3 Proprietary and Confidential 100G Datalogging FN ERT Module Meter Model Description Class Comments ERT Module Type ERT Module Part Number Romet RM Series ECM2 Electronically compensated meter Commercial Dresser ROOTS B3/LMMA Commercial Dresser ROOTS rotary meters equipped with WeigandWire solid state pulsers Dresser ROOTS IMC/W2 MC2 Dresser ROOTS Micro Correctors Commercial Itron/Actaris DATTUS fM2/fM3 Commercial Mercury Instruments EC-AT Mini-P Mini-AT Mini-Max Pressure and temperature electronic volume correctors Commercial Mercury Instruments TCI Temperature Compensating Index Commercial Meter must have connector pin with factory-installed pulse output. Purchase endpoint from Itron and correct cable interface from Romet. ECM2 must be configured for 750ms "off-
time" between pulses. The ECM2 must have firmware version J or later. Meter must have factory-
installed pulser with connector output. Purchase endpoint from Itron and correct cable interface from Dresser. Dresser pulser must be version 17 or higher to be compatible. Endpoint compatibile with IMC/W2 firmware version 1.93 or earlier. Pulse width must be set for 125ms. Pulse output must be at 100CF(CM) or higher. For all meter types, pulse width must be set to .050 seconds. Meter type 11M or smaller must have pulse weight minimum of 10 cubic feet or 1 cubic meter. Meter type 16M or greater must have pulse weight minimum of 100 cubic feet or 1 cubic meter. Correctors must have a Form A board; Form C is NOT supported. Item #056 Pulse Scaling Factor must be set to 2.0. Item #096 Cor Vol Display must be set at 1, 2, 3, or 4 blanks. endpoint does NOT support a setting of 0 blanks. Item #115 Output Pulse Code must be set at 1, 2, 3, or 4. endpoint does NOT support an Output Pulse Code of 0. Correctors must have a Form A board, Form C is NOT supported. Item #56 Pulse Scaling Factor must be 2.0. Item #96 must be 7, 6, 5, or 4 digits (1, 2, 3, & 4 blanks). Endpoint does NOT support 8 digits (0 blanks). Item # 1014 set to the preset Itron selection in the drop down menu. Compatible firmware versions on TCI are 1.06, 1.07, and 1.10. 100G Datalogging Remote
(12" lead wires) ERG-5002-503 100G Datalogging FN Remote (12" lead wires) ERG-5003-503 100G Remote (12" lead wires) 100G Datalogging Remote
(12" lead wires) 100G Datalogging FN Remote (12" lead wires) ERG-5000-503 ERG-5002-503 ERG-5003-503 100G Datalogging Remote
(12 lead wires) 100G Datalogging FN Remote (12" lead wires) ERG-5002-505 ERG-5003-505 100G Datalogging Remote
(5' cable) 100G Datalogging FN Remote (5' cable) ERG-5002-502 ERG-5003-502 100G Remote (5'cable) 100G Datalogging Remote
(5' cable) 100G Datalogging FN Remote (5' cable) ERG-5000-502 ERG-5002-502 ERG-5003-502 100G Datalogging Remote
(5 cable) 100G Datalogging Remote
(12 lead wires) 100G Datalogging FN Remote (5 cable) 100G Datalogging FN Remote (12" lead wires) 5: ERG-5002-502 12:ERG-5002-503 ERG-5003-502 ERG-5003-503 TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 4 Proprietary and Confidential 100G Datalogging FN ERT Module Installation Prerequisites The following tools are required to install, program, and check the 100G Datalogging FN remote ERT module. Some specific tools may be required dependent on meter or instrument type. Medium flat-blade screwdriver Small flat-blade screwdriver Medium Phillips screwdriver Hand pliers Side-cutting pliers 1/4-inch nut driver or similar blunt tool One-inch width putty knife Adjustable wrench 3M Scotchlock E-9Y crimping tool, 3M Scotchlock E-9C cartridge tool, or similar crimping tool All-weather electrical tape Size T-10 Torx screwdriver Itron programming device to program and check 100G Datalogging FN remote gas ERT module installation and operation:
FC200SR handheld computer with Endpoint-Link or Endpoint-Link Pro software version 5.3 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or FC300 with SRead with Endpoint-Link or Endpoint Link Pro version 5.5 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or 900 MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher or Field Deployment Manager (FDM) software version 1.1 or higher and a customer-supplied laptop Note Reference the appropriate programming guide or specification sheet for correct software version (see Related Documents on page 2). TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 5 Proprietary and Confidential C H A P T E R 2 Mounting the 100G Datalogging FN Remote ERT Module This chapter provides the instructions to mount the 100G Datalogging FN remote ERT module on a pipe or other flat vertical surface (wall). Installation Options Mount the 100G Datalogging FN remote ERT module using the Pipe Mount or Wall Mount (Flat Surface) procedure. Pipe Mount. Pipe mounting is used in conjunction with the Remote Mount Kit (Itron part number CFG-
0005-003). The pipe mount option places the ERT module on a pipe near the meter or instrument (not on a wall surface). This option requires a meter manufacturer's cable to connect the ERT module to the meter or instrument. Flat Vertical (Wall) Mount. Installation using the wall mount option places the ERT module on a wall or other vertical surface. A cable connects the ERT module to the meter or instrument. Mounting Screw Specifications Application To mount adapter plates on pipe brackets Itron Part Number 575-9930-016 Description 8-16 x 1/2-inch length, Type 8 slotted pan-head tapping screw - corrosion-resistant steel To mount remote ERT modules on adapter plates 575-9930-032 SCR-0009-001 To mount remote ERT modules on sheet metal surfaces (to mount ERT modules to wood surfaces, a comparable wood screw is required) 8-16 x 1-inch Type 8, slotted pan-head tapping screw, corrosion-resistant steel 10-16 x 1 1/2-inch Type AB thread for sheet metal, Phillips pan-head tapping screw, corrosion-resistant steel TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount Proprietary and Confidential 6 Mounting the 100G Datalogging FN Remote ERT Module Mounting Installation Considerations Select a proper mounting location. Itron recommends mounting the 100G Datalogging FN remote ERT module in close proximity to the meter or instrument. Some applications may require an extended cable-
length. The 100G Datalogging FN remote ERT module supports cable lengths up to 300 feet. Mount the 100G Datalogging FN remote ERT module in a vertical position with the ERT module label directional arrow pointed upward. Caution Upright vertical positioning is very important because:
100G Datalogging FN remote gas modules are designed with the antenna in a vertical direction so the antenna is parallel to the reading device (which has a vertical antenna). Matching antenna polarity can greatly affect RF performance and enable easy ERT module reading. 100G Datalogging FN remote gas modules are designed so the tilt tamper is vertical. It is important to maintain vertical positioning in the field to enable tilt tamper stability. Warning Do not mount the 100G Datalogging FN remote ERT module in an orientation other than vertical (remote ERT module label arrow pointed upward or downward). Violating the mounting orientation requirements will void the product warranty. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 7 Proprietary and Confidential Mounting the 100G Datalogging FN Remote ERT Module Mounting the Remote ERT Module on a Pipe The following items are required to mount the 100G Datalogging FN remote ERT module on a pipe or vertical flat surface (wall):
Itron Part Number Description ERG-5003-501 100G Datalogging FN Remote ERT Module ERG-5003-502 ERG-5003-503 ERG-5003-505 CFG-0005-003 Remote Mount Installation Kit Kit includes:
2 band clamps 2 tamper seals pipe bracket cable ties adapter plate
(ERG-5003-501 shown) Screws:
(2) 1/2-inch - to attach the adapter plate to pipe bracket
(2) 1-inch - to attach the ERT module to the adapter plate
(3) 1 1/2-inch - to attach the ERT module to a vertical surface
(wall) Warning Install the 100G Datalogging FN remote ERT module in an upright position. Any position other than upright can negatively affect radio performance and potentially reduce battery life. To mount the pipe bracket on a vertical pipe Caution Vertical mounting position is important to maximize RF performance. Mount the 100G Datalogging FN remote ERT module with the module's label arrow pointing up. The module's arrow must never point to either side or upside down. The module's tilt tamper functionality is designed to operate with the module installed vertically. 1. Remove the pipe bracket and band clamp from the Remote Mount Installation Kit (Itron part number CFG-0005-003). TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 8 Proprietary and Confidential Mounting the 100G Datalogging FN Remote ERT Module 2. Loosen the band clamp screw until the end of the band releases. 3. Push the end of the clamp's band (1) through the holes (2) in the pipe bracket. The pipe bracket must be oriented as shown below. 4. Place the band clamp around the pipe. The band will loosely wrap around the pipe. Push the end of the band through the band clamp screw assembly. Turn the band clamp's screw assembly to fit into the pipe bracket opening. Tighten the clamp screw until the band clamp is secure on the pipe. Caution The pipe bracket must fit firmly against the pipe to prevent slippage. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 9 Proprietary and Confidential Mounting the 100G Datalogging FN Remote ERT Module To mount the adapter plate on the pipe bracket Caution Vertical mounting position is important to maximize RF performance. Mount the 100G Datalogging FN remote ERT module with the module's label arrow pointing up. The module's arrow must never point to either side or upside down. The module's tilt tamper functionality is designed to operate with the module installed vertically. 1. Place the adapter plate on the pipe bracket with the mounting lug at the top or bottom. The adapter plate screw bosses fit into the pipe bracket recess. 2. Ensure the adapter plate is positioned as shown below with the mounting lug (1) at the top or bottom. To install the adapter plate on a vertical pipe, use the two shortest (1/2-inch) adapter plate mounting screws from the Remote Mount Installation Kit. Place the mounting screws (2) in the holes shown below. Upright module mounting 3. Tighten both screws securely in an alternating fashion. Itron recommends 9 to 12-inch-pounds torque. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 10 Proprietary and Confidential Mounting the 100G Datalogging FN Remote ERT Module To mount the 100G Datalogging FN remote ERT module on the adapter plate 1. Take the 100G Datalogging FN remote ERT module and the two one-inch mounting screws from the Remote Mount Installation kit. Place the back of the remote endpoint against the face of the adapter plate. The adapter plate mounting lug (1) must be positioned just above the endpoint mounting lug recess (2). 2. Push up on the 100G Datalogging FN remote ERT module until the adapter plate mounting lug (1) is as far as possible inside the module mounting lug recess (2). 3. Install the two one-inch ERT module mounting screws from the installation kit. 4. Tighten the module mounting screws evenly in an alternating fashion. Itron recommends 9 to 12 inch-
pounds of pressure. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 11 Proprietary and Confidential Mounting the 100G Datalogging FN Remote ERT Module Adapter Plate Mounting Positions The following pictures show adapter plates mounted on horizontal or 45-degree angle pipes. Caution Regardless of the pipe's direction, the adapter plate mounting lug must always be at the top. If the pipe is a 45 degree angle up to the right, install the adapter plate as shown below. Typical module mounting Mounted adapter plate If the pipe is a 45 degree angle up to the left, install the adapter plate as shown below. Typical module mounting Mounted adapter plate If the pipe is horizontal, install the adapter plate as shown below. Typical module mounting Mounted adapter plate TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 12 Proprietary and Confidential Mounting the 100G Datalogging FN Remote ERT Module To install tamper seals and cable ties 1. Place the new tamper seals from the Remote Mount Installation Kit over the 100G Datalogging FN remote ERT module mounting screws. 2. Firmly push both tamper seals all the way into place with a 1/4-inch nut driver or similar blunt tool. Note A tamper seal is fully seated when the top of the tamper seal is approximately 1/16 inch below the top of the screw recess. 3. Gather any excess ERT module cable. Loop a cable tie around the pipe and excess module cable. 4. Insert the chiseled end of the cable tie into the locking end and pull the cable tie tight. Cut off and properly dispose the excess cable tie. 100G Datalogging FN remote ERT module pipe mount installation is complete. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 13 Proprietary and Confidential Mounting the 100G Datalogging FN Remote ERT Module Mounting the ERT Module on a Wall or Other Flat Vertical Surface To mount the 100G Datalogging FN remote ERT module on a wall or other flat vertical surface Note For easier installation, you may drill three pilot holes in the mounting surface (use the proper size drill bit to accommodate the module mounting screws, see the Drilling Template below). When drilling pilot holes to mount the 100G Datalogging FN remote ERT module, the holes for the two bottom screws must be on a horizontal line. If you will mount the module on a sheet metal surface, use the mounting screws included with the 100G Datalogging FN remote ERT module mounting kit. Use a comparable wood screw to mount the module on a vertical wood surface. Carefully select a mounting location free from electrical wires. The mounting location must have the proper clearance to accommodate the 1-1/2-inch module mounting screws so nothing is damaged by the drill or mounting screws. 100G Datalogging FN Remote ERT Module drilling template A 3 inches B 1-11/16 inches C 3-3/8 inches 1. Using the three 1-1/2-inch mounting screws from the Remote Mount Installation Kit, turn the mounting screw for the mounting lug (top of module) part way into the mounting surface. 2. Place the 100G Datalogging FN remote ERT module mounting lug recess (on the top of the module's backplate) just under the screw head. Slide the module upward until the screw head fits completely inside the mounting lug recess. Several adjustments may be necessary to properly position the screw for module mounting. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 14 Proprietary and Confidential Mounting the 100G Datalogging FN Remote ERT Module 3. Install the bottom two mounting screws. Fasten screws in an alternating fashion until fully tightened to secure the module firmly in position. To install tamper seals and cable ties 1. Place a new tamper seal (from the Remote Mount Installation Kit) over each endpoint mounting screw. 2. Firmly push both tamper seals into place with a 1/4-inch nut driver or similar blunt tool. Note A tamper seal is fully seated when the top of the tamper seal is approximately 1/16-inch below the top of the screw recess. 3. To reduce the risk of cable damage, secure the excess module cable with the cable ties from the Remote Mount Installation Kit. Pull the cable tight. Remove and properly dispose the excess cable tie. 100G Datalogging FN remote ERT module installation on a vertical flat surface or wall is complete. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 15 Proprietary and Confidential C H A P T E R 3 Rotary Meter Installation This chapter provides the instructions to install the Datalogging FN remote ERT module on rotary gas meters. Reference the Gas Endpoint Meter Compatibility List (see 100G Datalogging FN Remote ERT Module Meter Compatibility List on page 3) for rotary meters compatible with the 100G Datalogging FN remote ERT module . Dresser ROOTS Series LMMA rotary meter American rotary meter Dresser ROOTS series B3 meter Romet Imperial series RM meter Romet Imperial ECM2 meter TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount Proprietary and Confidential 16 Rotary Meter Installation Required Installation Materials Available from Itron The materials in the following table are required to install a 100G Datalogging FN remote ERT module. Itron Part Number ERG-5003-503 Note this remote ERT module comes standard with 12-inch lead wires and may be shipped directly to the meter manufacturer for a factory-
installed cable (interface). The interface cable must be purchased directly from the meter manufacturer. ERG-5002-505 Note this remote ERT module comes standard with 12-inch lead wires and may be shipped directly to the meter manufacturer for a factory-
installed cable (interface). The interface cable must be purchased directly from the meter manufacturer. CFG-0005-003 Remote Endpoint Mounting Kit TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 17 Proprietary and Confidential Rotary Meter Installation To connect the 100G Datalogging FN remote ERT module cable assembly to the rotary meter Caution Verify the cable connector mates with the meter connector. Meter manufacturers use different connector styles (types). 1. Align the large lug on the 100G Datalogging FN remote ERT module connector with the large notch on the meter connector. 2. Align the lock ring notches on the module cable connector with the pins on the meter connector. 3. Hold the lock ring on the module connector back and push the plug into the meter connector until it is securely seated. 4. Turn the lock ring clockwise as far as it will go. You will feel it snap into place when it locks. Warning To remove the module connector plug from the meter connector jack, push in on the lock ring, turn the lock ring counterclockwise as far as possible, and pull out the plug body. Do not pull on the module's connector cable. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 18 Proprietary and Confidential Rotary Meter Installation 5. Install the new Datalogging FN remote ERT module on the wall or a pipe using the Remote Endpoint Mount Kit (Itron part number CFG-0005-003). See Mounting the 100G Datalogging FN Remote ERT Module on page 6 for mounting instructions. Programming the Remote ERT Module for Dresser ROOTS Rotary Meters To program 100G Datalogging FN remote ERT modules for use with Dresser ROOTS rotary meters, use the meter drive rates from the drive rate table in this section. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 19 Proprietary and Confidential Rotary Meter Installation B3, LMMA & S3A CTR/TC Meter Drive Rates for Remote ERT Module Programming Caution Do not use these meter drive rates to program residential direct-drive or commercial direct-drive modules. Use the information in the following tables to program 100G Datalogging FN remote ERT modules connected to Dresser ROOTS rotary meters.. B3, LMMA, S3A CTR/TC Meter Drive Rates B3 CTR Meter Size B3 CTR Meter Pulse Rate LMMA CTR Meter Size LMMA CTR Meter Pulse Rate 8C 11C 15C 2M 3M 5M 7M 11M 16M 23M 38M 56M 10 10 10 10 10 10 10 10 100 100 100 100 1.5M 3M 5M 7M 11M 16M 23M 38M 56M 102M 10 10 10 10 10 100 100 100 100 100 LMMA CTR Meter LMMA CTR Meter Pulse Size 1.5M 3M 5M 7M 11M 16M 23M 38M 56M 102M Rate 10 10 10 10 10 100 100 100 100 100 LMMA TC Meter Size LMMA TC Meter Pulse Rate 1.5M 3M 5M 7M 11M 16M 10 10 10 10 10 100 TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 20 Proprietary and Confidential Rotary Meter Installation Meters built 1/99 and beyond Meters built prior to 1/99 B3 TC Meter Size B3 TC Meter Pulse Rate B3 TC Meter B3 TC Meter Pulse Rate 8C 11C 15C 2M 3M 5M 7M 11M 16M 10 10 10 10 10 10 10 10 100 Size 8C 11C 15C 2M 3M 5M 7M 11M 16M 50 50 50 50 50 50 50 50 500 S3A CTR Meter Size S3A CTR Meter Pulse Rate S3A TC Meter S3A TC Meter Pulse Rate 1.5M 3M 5M 7M 11M 16M 10 10 10 10 10 100 Size 1.5M 3M 5M 7M 11M 16M 10 10 10 10 10 100 Installing the Remote ERT Module to the Elster American Meter RPM Series Rotary Meter Some meter manufacturers provide ERT mounting kits and installation procedures for their meters. If the 100G Datalogging FN remote ERT module to Elster American RPM meter installation instructions are not available, follow the installation procedure in this section. Elster American Meter RPM Series Rotary Meter TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 21 Proprietary and Confidential Rotary Meter Installation To install the 100G Datalogging FN remote ERT module on an Elster American RPM series meter 1. Remove the meter's top plate by removing the two 5mm screws and carefully prying up on the plate. The plate is secured with an o-ring seal. Remove the o-ring from the plate. Caution If the o-ring is damaged during removal, obtain a replacement from Elster American Meter Co. 2. Look into the meter tower and find the meter switch lead and connector (4-pin). 3. If the lead and connector are not visible or cannot be found, remove the four 5mm mounting screws and the register cover. The meter switch lead and connector will be visible inside the cover. 4. Feed the lead and connector into the register cover tower. Note Save any meter tags. You will re-install them later in the installation process. 5. If you removed the register cover, replace the cover using the four (4) 5mm mounting screws. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 22 Proprietary and Confidential Rotary Meter Installation 6. Attach the 4-pin male connector on the Elster American Meter adapter plate to the 4-pin female connector inside the meter's tower. The connectors will slide together and latch. 7. Carefully push the connectors and wires into the meter tower housing. 8. Lubricate the o-ring with o-ring lubricant and install the o-ring on the adapter plate. Insert the adapter plate into the tower and tighten the two 5 mm screws. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 23 Proprietary and Confidential Rotary Meter Installation To connect the manufacturer cable to the ERT module Note Connection to an Elster American Meter requires a cable interface compatible to an Elster American Meter RPM rotary meter. 1. Trim the ERT module wires to 3.5-inches. 2. Carefully strip the insulation covering from the meter cable (purchased from the meter manufacturer) approximately 1-1/2-inches from the end. Caution Do not cut through the individual wire insulation. 3. Separate the black, white, and blue wires for connection to the Datalogging FN remote ERT module. Cut off the unused wires even with the outer covering (insulation). Caution Do not strip the individual wires. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 24 Proprietary and Confidential Rotary Meter Installation 4. Connect the meter cable to the 100G Datalogging FN remote ERT module using 3M gel-cap connectors. Follow the wire connection table and wiring diagrams below. See Installation Prerequisites on page 5 for appropriate 3M crimping tools. Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity silicone-based gel to flow. If the silicone gel flows out of the crimped connector, avoid touching the gel. Gel flowing from the connector provides environmental protection for the connection. American RPM Meter to Datalogging FN remote ERT module Wire Connections American RPM Meter wire 100G Datalogging FN remote mount ERT module wire Red White Black Red White Blue TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 25 Proprietary and Confidential Rotary Meter Installation 5. Insert the meter cable through the slot on the ERT module backplate. Install a cable tie to the meter cable wire below the meter cable insulation to provide strain relief. 6. Tuck the connectors and cable tie into the ERT module housing. Place backplate on the assembly and tighten the four backplate screws using a size T-10 Torx screwdriver. Important Verify the cable tie and gel connectors are inside the module housing and the cable extends out of the slot in the backplate. Torque the backplate mounting screws to 9-12 inch-pounds. To install the Datalogging FN remote ERT module cable 1. Insert the plug on the cable connected to the ERT module into the receptacle on the meter adapter plate. 2. Tighten the threaded collar on the plug onto the American Meter interface receptacle. Verify the connection is hand-tight. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 26 Proprietary and Confidential Rotary Meter Installation Mounting the 100G Datalogging FN Remote Mount ERT Module Select an appropriate mounting location on adjacent piping close to the meter. Using the pipe bracket, mounting plate and band clamps from the Remote Mount Kit (Itron part number CFG-0005-003), secure the 100G Datalogging FN remote ERT module. Use the cable ties from the kit to secure any excess wire to the piping (see Mounting the 100G Datalogging FN Remote ERT Module on a Pipe on page 7). Installing the Remote ERT Module to the Romet Electronically Compensated Meter (ECM2) The Romet ECM2 meter has three Form A outputs that can be configured at the factory to provide any combination of the following three outputs:
Uncorrected volume (UNC VOL) Corrected volume (COR VOL) Alarm The pulse weight for the volumetric outputs is configured in SetUp Mode at Menu items > SET UNC OUT and Menu items > SET COR OUT. Since Setup Mode is fully configurable, the ECM2 module is universally adaptable to all Romet TC meter bodies. Reference the Romet technical manual for specific details on the ECM2. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 27 Proprietary and Confidential Rotary Meter Installation Connecting the ERT Module to the Romet ECM2 Meter Connect the correct interface wirings and set the output pulse spacing to complete 100G Datalogging FN remote ERT module installation with the Romet ECM2 meter. See the ECM2 Interface Wiring Table below to complete wire connections. Function
(+)UC
(-)UC
(+)CC
(-)CC
(+)ALM
(-)ALM
(+)Aux.CC
(-)Aux.CC ERT Module wire White and Red White and Red White and Red White and Red Blue Blue Blue Blue Pin location for Cannon Connector Part Number 34-125-20 34-125-40 34-125-41 34-125-42 34-125-43 34-125-44 34-125-45 34-125-50 34-125-51 C A A E A 3 3 B B B F B 1 1 A C C A A E 2 2 B D D B B D 5 5 E E E C E C 6 D F F D F F 4 C A 6 D B 4 Caution Set the ECM2 output pulse spacing to 750ms for operation with the 100G Datalogging FN remote ERT module. Output spacing represents an off-time between pulses. Romet ECM2 Mounting Requirement This mounting procedure requires the Romet ECM2/ERT Mounting Kit (Romet part number 34-444-1-KIT). TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 28 Proprietary and Confidential Rotary Meter Installation To mount the 100G Datalogging FN remote ERT module on the Romet ECM2 meter 1. Remove the module screw from the back of the ECM2 meter and discard. 2. Insert the mounting screw fitted with the three lock washers. Two lock washers are used as spacers as shown. 3. Attach the mounting plate to the meter. Insert the mounting screw where the module screw was removed. Torque the mounting screw to 5-7 ft.lbs. to secure the plate to the Romet meter. 4. Mount the 100G Datalogging FN remote ERT module using the pre-drilled holes on the mounting plate and the module mounting screws. 5. Place new tamper seals over the two screws. Press tamper seals into place using an 11/32-inch nut driver or similar blunt tool. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 29 Proprietary and Confidential Rotary Meter Installation 6. Connect the module to the meter using the previously installed cable interface. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 30 Proprietary and Confidential Rotary Meter Installation Programming the 100G Datalogging FN Remote ERT Module Caution You must program the 100G Datalogging FN remote ERT module before use. Follow the steps in this section to properly program the ERT module. Program the 100G Datalogging FN remote ERT modules using:
A FC200SR handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.3 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or A FC300 with SRead handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.5 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or A 900MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher or Field Deployment Manager
(FDM) software version 1.1 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. See the Endpoint-Link v5.3 (or higher) Endpoint Programming Guide (TDC-0744) or the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934) for more complete programming information. FC200SR FC300 with SRead 900MHz Belt Clip Radio TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 31 Proprietary and Confidential Rotary Meter Installation To program the 100G Datalogging FN remote ERT module 1. Program the meter drive rate into the 100G Datalogging FN remote ERT module using a handheld computer or Belt Clip Radio and laptop computer. For all programming and Check Endpoint operations using a handheld computer, hold the handheld as close to vertical as possible. For best success, keep the handheld within six feet of the target ERT module. Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the configuration file loaded into the programming device. During programming, the 100G Datalogging FN remote ERT module is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read to the nearest cubic foot. 2. Read or Check the 100G Datalogging FN remote ERT module using the handheld computer or Belt Clip Radio. If the read result is higher than the number programmed in step 1, the 100G Datalogging FN remote ERT module is counting correctly. If the read result is not higher than the number programmed in step 1, replace the 100G Datalogging FN remote ERT module. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 32 Proprietary and Confidential C H A P T E R 4 Electronic Volume Corrector and Instrument Installation This section provides the instructions to install the 100G Datalogging FN remote ERT module on:
Mercury Instruments Mini-P, Mini-AT, Mini-Max, and EC-AT Mercury Instruments Temperature Compensated Indexes (TCI) Dresser ROOTS IMC/W2 and MC2 Micro Correctors Mini-AT Mini-Max EC-AT TCI IMC/W2 MC2 TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount Proprietary and Confidential 33 Electronic Volume Corrector and Instrument Installation Installation Prerequisites 100G Datalogging FN remote ERT module installation to a volume corrector or instrument requires:
100G Datalogging FN remote ERT module compatible to a volume corrector or instrument (see the 100G Datalogging FN Remote ERT Module Meter Compatibility List on page 3). Volume corrector or instrument compatible with the remote ERT module. Proper tools and devices for installation and programming (see Installation Prerequisites on page 5). Installation Overview Installing the 100G Datalogging FN remote ERT module to a volume corrector or instrument involves five tasks:
1. Programming the Mercury Instrument (see Programming the Mercury Instrument on page 34 or reference the Mercury Instrument Programming Guide for more information). 2. Installing Mercury retrofit parts (if necessary). 3. Attaching the Datalogging FN remote ERT module to a pipe or vertical flat surface (wall) (see Mounting the 100G Datalogging FN Remote ERT Module). 4. Connecting the Datalogging FN remote ERT module on page 6 to the Mercury Instrument Volume Corrector (see To wire the ERT Module to the Mercury Instrument on page 37), Mercury Instrument Temperature Compensating Index (TCI), or Dresser ROOTS Micro Corrector (IMC/W2 or MC2). 5. Programming the Datalogging FN remote ERT module (see Programming the 100G Datalogging FN Remote ERT Module on page 30). TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 34 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation Programming the Mercury Instrument Code Settings Module does not support a Form-C pulse output board. Ka, Kb, Kc (Red Wire) Ya, Yb, Yc (Blue & White Wire) Connection must be on same terminal board channel (for example, Ka/Ya; Kb/Yb; Kc/Yc). Kc (Red Wire) Y (Blue & White Wire). For this option, module must be connected to Channel C. K (Red Wire) Y (Blue & White Wire). For optional SPA Bd., jumper must be installed on J1-B as indicated in the Mercury Quick Reference Guide (page 148) for Form A. K (Red Wire) Y (Blue & White Wire). For optional SPA Bd., jumper must be installed on J1-B as indicated in the Mercury Quick Reference Guide (page 148) for Form-A. Module does not support a Form-C pulse output board. K (Red Wire) Ya or Yb (Blue & White Wire) Module does not support a Form-C pulse output board. Item Code Settings and Corresponding Terminal Board Channel Terminal Board Connections*
Pulse Output Options Channel A Channel B Channel C Number of Blanked digits on CorVol Display Pulse Output Spacing Ka, Ya = Channel A
#056 #93 #057 #094 #058 #095 #96
#115
#1014
#1015 Pulse Board Ver-1(3) Form-C n/a n/a n/a n/a n/a n/a n/a n/a n/a Pulse Board Ver-2(3) Form-A 2.0000 0 2.0000 0 2.0000 0 1, 2, 3, or 4 1, 2, 3, or 4 n/a Pulse Board Ver-3(2) Form-C1 Form-A n/a n/a n/a n/a 2.0000 0 1, 2, 3, or 4 1, 2, 3, or 4 n/a Main Board Type-2 2.0000 0 n/a n/a n/a n/a 1, 2, 3, or 4 1, 2, 3, or 4 n/a n/a n/a n/a n/a 2.0000 0 2.0000 0 n/a n/a 1, 2, 3, or 4 1, 2, 3, or 4 n/a n/a Volume Instrument Type ECAT Mini with Form A Mainboard Mini-AT JB29, JB30 & JB31 Jumpered for Form-
A JB29, JB30 & JB31 Jumpered for Form-
C n/a n/a n/a n/a n/a n/a n/a n/a n/a Mini-Max All Main Boards 2 0 2 TCI Form C Main Board n/a n/a n/a 0 n/a n/a n/a n/a n/a 1, 2, 3, or 4 1, 2, or 4 n/a n/a n/a n/a n/a n/a n/a Form A Main Board 2.0000 0 2.0000 0 n/a n/a 1, 2, 3, or 4 blanks
(7, 6, 5, or 4 active) n/a Itron selection in dropdown menu. Itron selection in dropdown menu Connections to channels of output pulses are made through loose unterminated cable wires and gel connect connectors. Notes:
Code 0 for items 093, 094 & 095 = Corrected Volume Pulse Data Code 1 for item 115 = 1.000 Sec. Code 2 for item 115 = 2.000 Sec. Code 1 for item 096 = blank 1 digit and display 7 digits Code 2 for item 096 = blank 2 digits and display 6 digits Code 3 for item 096 = blank 3 digits and display 5 digits Code 4 for item 096 = blank 4 digits and display 4 digits
*For more information, see pages 11-20 of the "Basic Pulse Information for Mercury Instruments, Inc., Electronic Volume Correctors" manual, or contact Mercury Instruments at 513-272-1111. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 35 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation Mercury Instrument programming parameters:
Caution A Mercury Instrument must have a Form A board. A Form C board is not compatible with the 100G Datalogging FN remote ERT module. For TCI, when using both outputs, items 1014 and 1015 must be set to Itron. Item #056: Pulse A Scaling. Set at 2.0000 for a form A switch. Item #057: Pulse A Scaling. Set at 2.0000 for a form A switch. Item #058: Pulse A Scaling. Set at 2.0000 for a form A switch. Item #090: Corrected Volume Units: Code (0-20) selects the unit of measure for Corrected Volume
(Item000) and other "CorrVol" related items. Item #092: Uncorrected Volume Units: Code (0-20) selects the unit of measure for Uncorrected Volume
(Item002) and other "UncVol" related items. Item # 093, 094, 095: Type of gas volume information to be sent. For "CorrVol" selected, must be set at 0. Item # 096: Corrected Volume Display: Must be set at 1, 2, 3 or 4 blanks. Module does not support a setting of 0 blanks. Item # 097: Uncorrected Volume Display: Must be set at 1, 2, 3, or 4 blanks. Module does not support a setting of blanks. Item # 098: Check drive rate of the corrector. Should be the same as the plate above the uncorrected dials and the same as the plate on the index drive of the meter. Item # 115: Output Pulse Code: Must be set at 1 or 2. Wiring the ERT Module to the Instrument Use the terminal strip connector (Phoenix connector) in the Mercury Instrument to connect the 100G Datalogging FN remote ERT module to the instrument. Note In Mercury Instrument EC-AT correctors, the connector may be soldered to the pulse board. The 100G Datalogging FN remote ERT module has three lead wires (red, white, and blue). The red wire is attached according to Mercury Instrument Code Settings (see Code Settings on page 35). TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 36 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation The blue and white wires are twisted together and attached according to Mercury Instrument's Code Settings
(see Code Settings on page 35). To wire the ERT module to the Mercury Instrument 1. Insert the ERT module cable into the instrument's compression connector. 2. Strip one inch of the outer insulation from the 100G Datalogging FN remote ERT module. Strip 1/4-inch individual wire insulation from the red, white, and blue lead wires. A White wire B Blue wire C Red wire Caution Keep wires away from the rotating magnetic spindle in the Mercury Instrument. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 37 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation 3. See Mounting the 100G Datalogging FN Remote ERT Module on page 6 for module mounting instructions. Wiring Dual ERT Modules to a Mercury Instrument This section includes the information to wire dual ERT modules to a single Mercury Instrument. Installation requires the correct programming parameters (see Code Settings on page 35). With Itron 100G Datalogging FN remote ERT modules, utilities can receive corrected and uncorrected consumption values by installing two endpoints. The ERT module for corrected reads is attached to the corrector's pulse output. The ERT module for uncorrected reads is attached to the input switch board. The corrected pulse output is programmable; the uncorrected pulse output is dependent on the connected meter's drive rate. Important Some Mercury Instruments have two pulse outputs so the uncorrected pulse output could be connected to the additional output, but the connection should be to the input switch board in case the corrector battery fails. Counts will be collected if the uncorrected pulse is connected to the switch board since the board is not dependent on battery power. Dual Remote ERT Modules Mounted on a Mercury Instrument To install dual 100G Datalogging FN remote ERT modules to a Mercury Instrument Mini-Max Case Volume Corrector using Mercury Kit 22-1077 1. Place the Mercury Instrument volume corrector in shutdown condition and disconnect all power from the Mini-Max main board. 2. Remove the battery pack from the volume corrector and set it aside. 3. Remove the four screws from the main board and the board from the enclosure. Set the board aside. 4. Remove the two hex screws from the input switchboard and the switchboard from the enclosure and set it aside. You will re-install the switchboard later. Warning The battery pack, main board and switchboard may be damaged if left in the Mercury Instrument volume corrector while completing this installation. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 38 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation 5. Drill two 3/16-inch holes in the back of the Mini-Max enclosure as specified by the information included in the kit. Remove any metal shavings from the enclosure. 6. Clean the 100G Datalogging FN remote ERT modules with the alcohol wipe where you will place the Corrected and Uncorrected labels (included in the kit). Note Clean the Datalogging FN remote ERT modules with the alcohol wipe to ensure good label adhesion. 7. Mount the module for corrected pulse outputs on the left bracket mounting space. Insert three #8-32 x 1/2-
inch screws in a triangular pattern. Install the top screw so the head of the screw is approximately 1/8-inch from the Endpoint Mounting Bracket surface. Slide the module onto the screw so the mounting lug fits securely onto the screw. If necessary, remove the module and make any necessary adjustment to the screw depth to ensure a secure fit. Install the two bottom screws in an alternating fashion. 8. Mount the module for uncorrected pulse outputs on the right bracket mounting space. Insert three #8-32 x 1/2-inch screws in a triangular pattern. Install the top screw so the head of the screw is approximately 1/8-
inch from the Endpoint Mounting Bracket surface. Slide the endpoint onto the screw so the mounting lug fits securely onto the screw. If necessary, remove the module and make any necessary adjustment to the screw depth to ensure a secure fit. Install the two bottom screws in an alternating fashion. 9. Route the module cables under the bracket edge and toward the rear of the Mercury Instrument. 10. Mount the Endpoint Mounting Bracket (Mercury Instrument part number 22-1077, included in the kit) onto the Mini-Max enclosure. Place a #8 metal flat washer followed by a rubber sealing washer onto both
#8-32 x 3/8" screws. Align the lower threaded holes in the mounting bracket with the drilled enclosure holes and insert a screw/washer through the enclosure housing. Screws heads must be inside the enclosure. Tighten both screws using a screwdriver. Note Aligning the second bracket threaded hole and drilled hole may require some manipulation of the mounting bracket. 11. Insert the module cables (both units) through the large cable strain relief on the left rear of the instrument's enclosure. Leave a one-half to one inch drip loop under the cable strain relief. 12. Secure three cable ties on the module cables in three places on the cables as specified by information included in the kit. 13. Re-install the input switchboard, main board, and battery pack removed in step 2. 14. Connect the corrected module wires to TB1 on the Mini-Max board following the table below. Use Mercury upgrade kit 40-2678-1 to provide the second pulse output channel for the uncorrected ERT module. Corrected ERT Module Connections ERT Module Mini-Max TB1 Red wire Blue wire*
White wire*
K terminal Ya terminal Ya terminal
*Twist the blue and white endpoint wires together before connecting to the Mini-Max board. Tighten terminal connections securely. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 39 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation 15. Connect the uncorrected module wires to the Input Switch Board UNC. VOL following the table below. Uncorrected ERT Module Connections ERT Module Mini-Max Input Switch Board UNC. Vol. Red wire Blue wire*
White wire*
COM terminal NO terminal NO terminal
*Twist the blue and white ERT module wires together before connecting to the Mini-Max board. Tighten terminal connections securely. 16. Tighten the large strain relief securely. Warning Do not crush the endpoint through-cables when tightening the strain relief. 17. Re-install or reconnect the power or battery sources. 18. Close the instrument case and tighten the case screw securely. Replace any locks that were removed for installation. Wiring the Remote ERT Module to the Mercury TCI The Mercury Instruments Temperature Compensating Index (TCI) provides two Form-A volume pulse outputs and one Form-B alarm output. These outputs are electronic switches. The first two pulse outputs are configurable for compensated or uncompensated volume. The third output (Form-B) is for alarm output use only. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 40 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation Connections to the three output pulse channels are completed using loose unterminated wires (the individual wires from a cable) and gel-connectors. The TCI unit has six unterminated wires and six gel-connectors (Itron part number CON-0023-001) to enable pulse connections to ancillary devices. Loose wires are located inside the gray adapter plate behind the black strain relief fitting. Adapter plate with black strain relief Loose cable wires The three switch contacts on the TCI PC board are MOSFET output type opto-isolators that provide high voltage isolation between the sensitive processor components of the TCI board and the outside world. Wire Color Description Function Orange Yellow White Green Brown Blue Volume output channel A Comp/uncomp volume pulse Volume output channel A
(configurable pulse timing) Volume output channel B Comp/uncomp volume pulse Volume Output channel B
(configurable pulse timing) Alarm channel Alarm channel Alarm event signal
(Pulse timing) To make TCI pulse connections Note Connect one ERT module/channel to the alarm output if the modules are used on channels A and B. 1. Remove strain relief fitting by unscrewing from the gray adapter plate. Note Do not remove the fitting's hex nut. Un-screw the entire fitting from the gray adapter plate. A tether line is secured to the strain relief fitting. When the strain relief fitting is removed, the tether line pulls the unterminated wires out of the adapter plate for access to the loose wires. 2. Loosen the strain relief fitting hex nut and remove the white plug from the center. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 41 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation 3. Place the strain relief fitting onto the field pulse cable. 4. If the field pulse cable is smaller than a 0.2-inch diameter, install the rubber tube supplied with the TCI onto the cable so the strain relief will clamp onto the tube after it is re-installed. 5. Connect the individual external pulse cable conductors to the un-terminated wires following Configuration for two endpoints connected to one TCI. Insert one un-terminated wire into an opening of a gel-connector (six gel-connectors were included with the TCI). Insert the appropriate field cable wire into the other gel-connector opening. Configuration for two ERT modules connected to one TCI Channel A ERG-500x-503 White Red Blue Channel B ERG-500x-503 White Red Blue TCI Orange and brown Yellow Blue (alarm) TCI White Green White TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 42 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation 6. Verify both wires are fully inserted into the gel-connector prior to crimping. Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity silicone-based gel to flow. If the silicone gel flows out of the crimped connector, avoid touching the gel. Gel flowing from the connector provides environmental protection for the connection. 7. Insert the gel-connected wires into the threaded gray adapter plate hole. 8. Replace the strain relief and tighten until secure. Connecting the 100G Datalogging FN Remote Mount ERT Module to the IMC/W2 or MC2 Cable You may ship the Itron 100G Datalogging FN remote ERT module directly to Dresser ROOTS Meters for a factory-installed cable. If you connect the ERT module to the meter using an existing cable purchased from Dresser ROOTS, complete the following cable installation procedure. Caution The purchased cable must have a mating connector compatible with the IMC/W2 or MC2 receptacle. Dresser ROOTS cables may be wired in different configurations for specific applications. If necessary, contact Dresser ROOTS Meters for wiring diagrams for your specific application. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 43 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation To connect the 100G Datalogging FN remote ERT module to the IMC/W2 or MC2 cable 1. Remove the backplate (4 screws) from the 100G Datalogging FN remote ERT module and expose the module lead wires. The backplate and screws will be re-installed on the module later in this procedure so store them (temporarily) in a safe, secure place. 2. Insert the lead wires from the 100G Datalogging FN remote ERT module into new 3M gel connectors
(Itron part number CON-0023-001) together with the same colored lead wire from the meter cable (see the wiring table below) and crimp using a 3M hand-held crimping tool. Important Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimping gel-connects. The crimping tool provides an even pressured crimp to make a secure connection. Apply pressure for three seconds until the gel cap is fully crimped (collapsed) to allow time for the low viscosity silicone-based gel to flow. If the silicone gel flows out of the crimped connector, avoid touching the gel. Gel flowing from the connector provides environmental protection for the connection. Note Do not strip lead wire prior to inserting the wire in the gel connector. IMC/W2 to Remote ERT Module Wire Table IMC/W2 Wire Remote Module wire Red White Blue Red White Blue TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 44 Proprietary and Confidential
1 2 | Users Manual 2 | Users Manual | 1.59 MiB |
Electronic Volume Corrector and Instrument Installation 3. Dresser ROOTS IMC/W2 and MC2 cables are typically delivered with a cable tie installed. If the meter cable does not include a cable tie, install a tie to the cable just below the exposed colored lead wires on the cable insulation. Remove the excess cable tie using a hand-held sidecutter pliers. The cable tie performs as a cable strain relief to mitigate the risk of destructive tension on the lead wires. 4. Tuck the three gel connectors and cable tie inside the endpoint housing, as shown. Position the cable tie as shown by the arrow. 5. Install the 100G Datalogging FN remote ERT module backplate using the four screws previously removed from the ERT module and a Torx T-15 screwdriver. Important Verify the cable tie and gel connectors are inside the module housing and the cable extends out of the slot in the backplate. Torque the backplate mounting screws to 9-12 inch-pounds. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 45 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation Installing the ERT Module to the Dresser ROOTS Micro Corrector (IMC/W2 or MC2) Dresser ROOTS Meters and Instruments offer a mounting bracket kit assembly to direct mount Itron's 100G Datalogging FN ERT module to the IMC/W2. Dresser ROOTS Meters Instruments Mounting Bracket Kit
(Dresser ROOTS Part Number 057783-000) Quantity 1 1 2 3 4 4 Description Mounting bracket Screw, 8-32 x 7/16-inch Screw, 8-32 x 3/4-inch Nut, 8-32 Spacer, #10 ERT module/bracket mounting screw, M6 x 20 mm Dresser ROOTS Part Number 015951-000 000163-277 000163-282 012829-005 053669-001 013444-002 Important Dresser ROOTS mounting bracket kit does not include the cable required to connect the 100G Datalogging FN remote ERT module to the Amphenal connector on the IMC\W2. Dresser ROOTS Accessories Description 9" A-B male cable 9" D-E male cable Dresser ROOTS Part Number 054983-012 054983-010 TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 46 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation To attach the ERT module to the IMC\W2 and MC2 1. Insert the 8-32 x 7/16-inch screw (A) into the top of the mounting bracket. Insert the two 8-32 x 3/4-inch screws (B) into the bottom of the mounting bracket. 2. Insert one 3/32-inch nut on the top 7/16-inch bracket screw (A). Slide the 100G Datalogging FN remote ERT module mounting lug over the top of the bracket screw and nut. 3. Secure the bottom 100G Datalogging FN remote ERT module mounting holes over the two 8-32 x 3/4-
inch screws with the remaining two 8-32 nuts. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 47 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation 4. Insert the #10 spacers into the four mounting holes on the back of the IMC\W2. Caution Upright vertical positioning is very important because:
100G Datalogging FN remote ERT modules are designed with the antenna in a vertical direction so the antenna is parallel to the reading device (which has a vertical antenna). Matching antenna polarity can greatly affect RF performance and enable easy ERT module reading. 100G Datalogging FN remote ERT modules are designed so the tilt tamper is vertical. It is important to maintain vertical positioning in the field to enable tilt tamper stability. 100G Datalogging FN remote ERT module batteries must be vertical (installed with the positive terminal upward) or battery life is compromised. 5. Secure the endpoint/bracket assembly on the IMC\W2 using four endpoint/mounting bracket screws (M6 x 20 mm). 6. There are two options to connect the 100G Datalogging FN remote ERT module to Dresser ROOTS to the IMC\W2:
1. For the Amphenol connector: plug the connector from the Itron ERT module to the IMC\W2 volume input connector. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 48 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation 2. For the cable gland or conduit fitting:
a. Route the cable from the 100G Datalogging FN remote ERT module through the IMC\W2 cable gland/conduit connector. To receive uncorrected reads: connect the red wire to the terminal block 3 (TB3 telemetry output) GND1 (ground) position (B). Connect the white and blue wires to the pulse output 1 position (A). To receive corrected reads: connect the red wire to the GND 2/3 (ground) TB3 telemetry output position
(C). Connect the white and blue wires to the pulse output 2 position. b. Tighten the cable gland fitting around the cable. Apply 15 inch-pounds torque. Note 100G Datalogging FN remote ERT modules using the flying lead cable assembly (Dresser ROOTS part number 055018-700) are factory wired to terminal block 3 (TB3) according to IMC\W2 pulse output default configuration. Consult the customer specification for other wiring configurations. To test the 100G Datalogging FN remote ERT module IMC\W2 installation 1. Connect the IMC\W2 to the PC using the serial cable. 2. Using the Dresser ROOTS User Terminal (UT) communications software, connect to the IMC\W2. 3. Read the uncorrected or corrected count number on the 100G Datalogging FN remote ERT module with the Itron endpoint reading device. Compare the IMC\W2 uncorrected or corrected amounts to the 100G Datalogging FN remote ERT module 4. Input approximately 20 pulses to the 100G Datalogging FN remote ERT module. Verify the uncorrected or corrected counts on the IMC\W2 and the Datalogging FN remote ERT module are the same. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 49 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation Programming the 100G Datalogging FN Remote ERT Module Caution You must program the 100G Datalogging FN remote ERT module before use. Follow the steps in this section to properly program the ERT module. Program the 100G Datalogging FN remote ERT modules using:
A FC200SR handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.3 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or A FC300 with SRead handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.5 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or A 900MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher or Field Deployment Manager
(FDM) software version 1.1 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. See the Endpoint-Link v5.3 (or higher) Endpoint Programming Guide (TDC-0744) or the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934) for more complete programming information. FC200SR FC300 with SRead 900MHz Belt Clip Radio TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 50 Proprietary and Confidential Electronic Volume Corrector and Instrument Installation To program the 100G Datalogging FN remote ERT module 1. Program the meter drive rate into the 100G Datalogging FN remote ERT module using a handheld computer or Belt Clip Radio and laptop computer. For all programming and Check Endpoint operations using a handheld computer, hold the handheld as close to vertical as possible. For best success, keep the handheld within six feet of the target ERT module. Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the configuration file loaded into the programming device. During programming, the100G Datalogging FN remote ERT module is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read to the nearest cubic foot. 2. Read or Check the 100G Datalogging FN remote ERT module using the handheld computer or Belt Clip Radio. If the read result is higher than the number programmed in step 1, the 100G Datalogging FN remote ERT module is counting correctly. If the read result is not higher than the number programmed in step 1, replace the 100G Datalogging FN remote ERT module. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 51 Proprietary and Confidential C H A P T E R 5 Diaphragm Meter Installation This chapter provides the instructions to install Remote 100G Datalogging FN remote ERT modules (Itron part number ERG-5003-501 with 2.5 foot cable and encoder) on the diaphragm gas meters where a direct mount endpoint is not possible. Reference the Itron Gas Endpoint Meter Compatibility List (PUB-0117-002 or the 100G Datalogging FN Remote ERT Module Meter Compatibility List on page 3 for compatible diaphragm meters. Tools and Materials Supplied By You Note 100G Datalogging FN remote ERT module installation to a diaphragm meter may require additional tools and materials over those listed in Installation Prerequisites on page 5. The following user/installer-supplied tools and materials are required to install, program, and check the 100G Datalogging FN remote ERT module:
Medium flat-blade screwdriver Medium flat-blade, torque-measuring screwdriver Medium Phillips screwdriver Pliers Side-cutting pliers or similar tool 1/4-inch nut driver or other blunt tool for seating ERT module tamper Itron programming device to program and check 100G Datalogging FN remote ERT module installation and operation:
FC200SR handheld computer with Endpoint-Link or Endpoint-Link Pro software version 5.3 or higher or Field Deployment Manager (FDM) version 1.1 or higher or FC300 with SRead with Endpoint-Link or Endpoint Link Pro version 5.5 or higher Field Deployment Manager (FDM) version 1.1 or higher or 900 MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher or Field Deployment Manager (FDM) version 1.1 or higher and a customer-supplied laptop Note Reference the appropriate programming guide or specification sheet for correct software version (see Related Documents on page 2). 1-inch putty knife or similar tool to remove old gasket material from the meter and index cover Replacement temperature compensation (TEMP COMP) meter index stickers (if required) TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount Proprietary and Confidential 52 Diaphragm Meter Installation Materials Available from Itron The following items are required for each 100G Datalogging FN remote ERT module installation to a diaphragm gas meter:
Itron Part Number Description ERG-5003-501 100G Datalogging FN Remote ERT Module with 2.5' encoder cable CFG-0081-001 Remote Mount Encoder Kit A acetone applicator stick B tamper seals C cable ties D mounting screws E magnet hub spacer F magnet hub 013-1723-112 Encoder Spacing Tool
(Use the Encoder Spacing Tool to ensure the encoder mounts the correct distance from the magnet hub on the meter index.) Replacement Gaskets The Itron replacement index cover gaskets shown below are thicker than standard gaskets and have a special slot to accommodate the encoder cable. Gaskets are designed for Schlumberger/Sprague model 675 and 1000 commercial diaphragm meters. These gaskets may be incompatible on meters from other manufacturers;
alternate cable relief procedures may be necessary. 4-hole front cover gasket:
2-hole front cover gasket:
1-hole front cover gasket:
Itron part number FAB-0014-003 Itron part number FAB-0014-002 Itron part number FAB-0014-001 TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 53 Proprietary and Confidential Diaphragm Meter Installation Installing the 100G Datalogging FN Remote ERT Module The 100G Datalogging FN remote ERT module mounts on a pipe using the Remote Mount Installation Kit
(Itron part number CFG-0005-003) or a vertical flat (wall) surface. Always mount the 100G Datalogging FN remote ERT module with the printed label right-side-up (arrow pointing up -1), and the encoder wires (2) and tamper seals (3) at the bottom, as shown. Caution Upright vertical positioning is very important because:
100G Datalogging FN remote ERT modules are designed with the antenna in a vertical direction so the antenna is parallel to the reading device (which has a vertical antenna). Matching antenna polarity can greatly affect RF performance and enable easy endpoint reading. 100G Datalogging FN remote ERT modules are designed so the tilt tamper is vertical. It is important to maintain vertical positioning in the field to enable tilt tamper stability. 100G Datalogging FN remote ERT module batteries must be vertical (installed with the positive terminal upward) or battery life is compromised. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 54 Proprietary and Confidential Diaphragm Meter Installation Installing 100G Datalogging FN Remote ERT Module Encoders Caution To insure proper adhesion, the 100G Datalogging FN remote ERT module encoder must be installed at temperatures between 40 to 95 Fahrenheit. There are four tasks when installing the Datalogging FN remote ERT module with an encoder on a diaphragm meter:
1. Remove the index cover and any gasket residue. 2. Install the 100G Datalogging FN remote ERT module encoder on the index. 3. Program the 100G Datalogging FN remote ERT module. 4. Attach the index cover to the meter. To remove the index Note Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not leave materials on customer premises. Replace any stripped, worn, or corroded mounting screws. 1. Cut and remove any wire seal routed through the index cover screws. Remove the index cover and set aside. Remove the index mounting screws in an alternating fashion. 2. Remove the two index screws in an alternating fashion. Loosen the left index screw two turns, loosen the index screw three to four turns. Hold the index while removing the screws to keep the index from falling. Set the index aside where it will not be damaged. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 55 Proprietary and Confidential Diaphragm Meter Installation 3. Remove the old gasket and any gasket residue from the meter and the index cover. 4. Use the FC200 or FC300 to read the 100G Datalogging FN remote ERT module. Record the reading for comparison with progressive readings as installation is completed. To install the encoder 1. Remove the magnet hub from the Encoder Installation kit ( Itron part number CFG-0081-001). Verify there is only one magnet in the hub. Note If there is no magnet or if there are two magnets in the magnet hub, discard the magnet hub and use a hub with one magnet. 2. Briefly place the magnet side of the magnet hub into the curved indentation in the encoder, as shown. 3. Remove the magnet hub from the encoder and set it at least one inch away from the encoder. 4. Use the endpoint programming device to read the 100G Datalogging FN remote ERT module. If this reading is higher than the reading taken after removing the index, the ERT module is counting and working properly. Note If the reading is not higher than the previous reading, the 100G Datalogging FN remote ERT module is not reading. Repeat steps 3, 4, and 5. If the ERT module is still not counting, replace the 100G Datalogging FN remote ERT module and perform steps 3, 4, and 5. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 56 Proprietary and Confidential Diaphragm Meter Installation 5. Align the large notch in the side of the magnet hub spacer with the needle of the meter drive rate dial (1-
foot or 2-foot for residential diaphragm meters; 5-, 10-, or 100-foot for commercial diaphragm meters). 6. Press the magnet hub spacer down over the dial needle as far as possible. The tip on the bottom of the spacer may touch index face. Turn the dial in the direction noted on the index after hub spacer installation to verify the index dial functions with a smooth, easy rotation. 7. Align the pointer (1) on the top of the magnet hub and the notch (2) in the side of the magnet hub with the needle (3) of the meter drive rate dial. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 57 Proprietary and Confidential Diaphragm Meter Installation 8. Press the magnet hub down over the hub spacer as far as possible. The bottom of the hub spacer may touch the index face. Turn the dial after magnet hub installation to verify the index dial functions with a smooth, easy rotation. 9. If the tip of the dial needle sticks out past the edge of the magnet hub, cut off the end of the dial needle as close as possible to the magnet hub with a sharp, side-cutting pliers. 10. Remove the acetone stick applicator from the Remote Encoder Installation Kit (Itron part number CFG-
0081-001). 11. Select a location on the index face next to the magnet hub. After encoder installation, the encoder cable must not interfere with the index dials. Note If a TEMP COMP sticker is attached to the index where the encoder cable will mount, remove it before cleaning with the acetone stick. If the sticker (or replacement sticker) must be put back on the register face, place it in a new location on the index face after the encoder is attached. 12. Tilt the acetone stick vertically with the wick end down. Squeeze the acetone stick on the black dot until the packet inside the pen breaks. Continue to hold the acetone stick vertical until the acetone wicks into the foam applicator end. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 58 Proprietary and Confidential Diaphragm Meter Installation 13. Thoroughly apply acetone to the area where you will install the encoder. Do not touch the cleaned area of the index face before the encoder is installed. 14. Slide the thin end of the encoder spacing tool down over the magnet hub. 15. Peel the strip of protective plastic off the adhesive side of the module's encoder. Important You must do the next two steps exactly as described or the 100G Datalogging FN remote ERT module will not work properly. 16. Press the curved side of the encoder firmly against the side of the encoder spacing tool as shown below, with the adhesive side down. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 59 Proprietary and Confidential Diaphragm Meter Installation 17. Slide the encoder down along the side of the encoder spacing tool until it touches the surface of the index
(as shown below). Using moderate pressure, hold the encoder firmly against the index, without moving, for 15 seconds to permanently apply the encoder. The photo below shows how the encoder spacing tool and encoder will look after the 15 second wait time. 18. Remove the encoder spacing tool and lay the index on a flat, horizontal surface, to diminish strain on the encoder cable. 19. Program the index reading (with the encoder mounted) into the 100G Datalogging FN remote ERT module. 20. Read the 100G Datalogging FN remote ERT module If this reading is the same as the reading programmed into the 100G Datalogging FN remote ERT module, the ERT module is programmed correctly. Index Cover Installation Required Materials Use the correct replacement index cover gasket for your index (see Replacement Gaskets on page 53 for Itron 4-hole, 2-hole, or 1-hole gasket part numbers). TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 60 Proprietary and Confidential Diaphragm Meter Installation To install the meter index covers over the ERT module encoder cable 1. Remove the gasket center and index cover hole plugs from the new gasket. 2. Insert the index/encoder assembly through the gasket center. Verify the gasket's adhesive-backed side is facing the meter face. 3. Align the index wriggler with the meter's drive dog. Install the index on the meter using the index mounting screws. Tighten one index screw two turns. Install and tighten the remaining index screw. Tighten the first index mounting screw completely (alternating fashion). 4. Install a strain-relief cable tie about 1-1/4-inch from the encoder cable's stripped end. The cable tie must be inside the index cover after the cover is installed on the meter. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 61 Proprietary and Confidential Diaphragm Meter Installation 5. Remove the excess cable tie with a side-cutting pliers. Dispose excess cable tie properly. 6. Remove the protective backing on the replacement gasket to expose the adhesive side of the gasket. Align the gasket (1), encoder cable (2), and cable tie (for strain-relief) (3) on the meter as shown. Caution Route the encoder cable inside the index cover to provide strain relief (minimize pulling or twisting on the encoder). Verify the strain-relief cable tie on the encoder cable is inside the index cover when the cover is installed on the meter. The gasket must align with the index cover screw holes and adhere to the meter face to insure a proper seal after the index cover is installed. 7. Install the four index cover screws and tighten just enough to hold the screws in place. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 62 Proprietary and Confidential Diaphragm Meter Installation 8. Verify the encoder cable is in the cable slot of the gasket. Fully tighten the screws in an alternating fashion. If required, install utility-approved security wire seals. 100G Datalogging FN remote ERT module encoder/index installation is complete. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 63 Proprietary and Confidential Diaphragm Meter Installation Programming the 100G Datalogging FN Remote ERT Module Caution You must program the 100G Datalogging FN remote ERT module before use. Follow the steps in this section to properly program the ERT module. Program the 100G Datalogging FN remote ERT modules using:
A FC200SR handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.3 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or A FC300 with SRead handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.5 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or A 900MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher or Field Deployment Manager
(FDM) software version 1.1 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. See the Endpoint-Link v5.3 (or higher) Endpoint Programming Guide (TDC-0744) or the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934) for more complete programming information. FC200SR FC300 with SRead 900MHz Belt Clip Radio TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 64 Proprietary and Confidential Diaphragm Meter Installation To program the 100G Datalogging FN remote ERT module 1. Program the meter drive rate into the 100G Datalogging FN remote ERT module using a handheld computer or Belt Clip Radio and laptop computer. For all programming and Check Endpoint operations using a handheld computer, hold the handheld as close to vertical as possible. For best success, keep the handheld within six feet of the target ERT module. Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the configuration file loaded into the programming device. During programming, the 100G Datalogging FN remote ERT module is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read to the nearest cubic foot. 2. Read or Check the 100G Datalogging FN remote ERT module using the handheld computer or Belt Clip Radio. If the read result is higher than the number programmed in step 1, the 100G Datalogging FN remote ERT module is counting correctly. If the read result is not higher than the number programmed in step 1, replace the 100G Datalogging FN remote ERT module. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 65 Proprietary and Confidential C H A P T E R 6 DATTUS Meter Installation This section provides the instructions to install the 100G Datalogging FN remote ERT module with Itron DATTUS fM2 and fM3 meters. DATTUS fM2 DATTUS fM3 Installation Prerequisites 100G Datalogging FN remote ERT module installation to a DATTUS meter requires the following materials:
100G Datalogging FN remote ERT module compatible with the DATTUS meter (see the 100G Datalogging FN Remote ERT Module Meter Compatibility List on page 3). Itron DATTUS meter compatible with the 100G Datalogging FN remote ERT module. Tools and devices to complete installation and programming (see Installation Prerequisites on page 5) Programming the DATTUS Meter Program the DATTUS fM2 or fM3 meter with the correct pulse width and weight. For all DATTUS type meters, the pulse width must be set to .050 seconds. DATTUS Meter Pulse Weight Settings Meter type Pulse weight in cubic feet (CF) or cubic meter (CM) 11M or smaller 10 (CF) or 1 CM 16M or greater 100 CF or 1 CM Installation Overview Installing the 100G Datalogging FN remote ERT module to an DATTUS meter involves five tasks:
1. Programming the meter (see Programming the DATTUS Meter on page 66 or the Itron DATTUS programming guide for more information). TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount Proprietary and Confidential 66 DATTUS Meter Installation 2. Installing any necessary Itron retrofit parts. Itron offers installation kits and brackets for endpoint mounting options (see Installing the Remote ERT Module to Itron DATTUS Meters on page 67 or Direct Mounting the Remote ERT Module to the DATTUS Meter on page 68). 3. Mounting the 100G Datalogging FN remote ERT module directly on the meter. If direct-mounting is not an option for your installation, the 100G Datalogging FN remote ERT module may be mounted on a pipe, or flat surface (see Mounting the 100G Datalogging FN Remote ERT Module). 4. Connecting the 100G Datalogging FN remote ERT module to the DATTUS meter (see Connecting the Remote ERT Module to a DATTUS Meter on page 69). 5. Programming the 100G Datalogging FN remote ERT module (see Programming the 100G Datalogging FN Remote ERT Module on page 30). Installing the Remote ERT Module to Itron DATTUS Meters DATTUS meters provide a an electronic pulse output compatible with the 100G Datalogging FN remote ERT module. The DATTUS meter may be wired to the ERT module using the pulse output cable or the module can be directly mounted to the meter. When ordering, customers can have the 100G Datalogging FN remote ERT modules drop shipped to Itron's Owenton, Kentucky meter factory to have a factory-installed connector attached to the module's bare leads. The connector directly fits the pulse output on the DATTUS meter. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 67 Proprietary and Confidential DATTUS Meter Installation Direct Mounting the Remote ERT Module to the DATTUS Meter 100G Datalogging FN remote ERT modules can be direct mounted to DATTUS fM2 and fM3 meters with the DATTUS Direct Mount Kit (Itron part number 442491-001). You can rotate DATTUS meter registers to accommodate vertical or horizontal meter. Customers may have Itron, Owenton, Kentucky complete the cover modification and bracket attachment or may order the kit to retrofit the DATTUS meter. The external cover of the DATTUS meter is modified with three holes to mount the endpoint bracket. The modification is dependent on the orientation of the meter installation. A B Horizontally oriented meter endpoint mounting hole modifications. Vertically oriented meter endpoint mounting hole modifications. Caution The 100G Datalogging FN remote ERT module must be mounted in an upright position with the arrow on the label pointing upward. After the meter cover and bracket are replaced on the meter, the 100G Datalogging FN remote ERT module is connected to the pulse output of the DATTUS meter by the Binder Connector. The endpoint is seated into the bracket to create a secure assembly. Horizontal installation Vertical installation TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 68 Proprietary and Confidential DATTUS Meter Installation Connecting the Remote ERT Module to a DATTUS meter The DATTUS fM2 and fM3 meters have two configurable outputs usable as pulse outputs to the 100G Datalogging FN remote ERT module. Connecting the endpoint following the information in this section requires a pulse output cable, installed at the Owenton, Kentucky Itron location. Pulse output cables are available in 10-foot and 20-foot lengths. Factory-installed cables have a Binder connector on one end and six bare wires on the opposite end. DATTUS Meter Wiring Accessories (available from Itron, Owenton, Kentucky) Accessory Pulse output cable - 10 ft. Pulse output cable - 20 ft. Itron Part Number 442461-009 442461-010 Pulse output cable To wire the 100G Datalogging FN remote ERT module to the DATTUS meter Pulse Output Cable Pin Descriptions To use Output 3 To use Output 4 Pin Function Wire color ERT wire color ERT wire color 1 2 3 4 5 6 Cut cable Output 4 (+) Ground (-) White Black Green Output 3 (+) Orange Cut cable Ground (-) Red Blue White Blue Red Blue White Red TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 69 Proprietary and Confidential DATTUS Meter Installation Mounting the 100G Datalogging FN Remote ERT Module You can mount the 100G Datalogging FN remote ERT module on a pipe or vertical flat surface (wall). Mounting requires the Itron Remote Mount Kit (Itron part number CFG-0005-003). See Mounting the 100G Datalogging FN Remote ERT Module on page 6 for mounting instructions. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 70 Proprietary and Confidential DATTUS Meter Installation Programming the 100G Datalogging FN Remote ERT Module Caution You must program the 100G Datalogging FN remote ERT module before use. Follow the steps in this section to properly program the ERT module. Program the 100G Datalogging FN remote ERT modules using:
A FC200SR handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.3 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or A FC300 with SRead handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.5 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or A 900MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher or Field Deployment Manager
(FDM) software version 1.1 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. See the Endpoint-Link v5.3 (or higher) Endpoint Programming Guide (TDC-0744) or the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934) for more complete programming information. FC200SR FC300 with SRead 900MHz Belt Clip Radio TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 71 Proprietary and Confidential DATTUS Meter Installation To program the 100G Datalogging FN remote ERT module 1. Program the meter drive rate into the 100G Datalogging FN remote ERT module using a handheld computer or Belt Clip Radio and laptop computer. For all programming and Check Endpoint operations using a handheld computer, hold the handheld as Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the configuration file loaded into the programming device. During programming, the 100G Datalogging FN remote ERT module is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read to the nearest cubic foot. 2. Read or Check the 100G Datalogging FN remote ERT module using the handheld computer or Belt Clip Radio. If the read result is higher than the number programmed in step 1, the 100G Datalogging FN remote ERT module is counting correctly. If the read result is not higher than the number programmed in step 1, replace the 100G Datalogging FN remote ERT module. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 72 Proprietary and Confidential C H A P T E R 7 Sensus Sonix Meter Installation Sensus Sonix Meter Programming the Sensus Sonix Meter Program the Sensus Sonix meter following the Sensus programming guidelines. Adjusting the Pulse Output for Sonix 600 and 880 Meters The pulse output sent to the 100G Datalogging FN remote ERT module may be set (using the SonixCom software) as:
1 pulse per 10 cf 1 pulse per 100 cf 1 pulse per 1000 cf Contact Sensus North American Gas Customer Service for more information. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount Proprietary and Confidential 73 Sensus Sonix Meter Installation Installing the 100G Datalogging FN Remote ERT Module with Sensus Sonix Meters Sensus Sonix meters provide a standard Form A electronic pulse output compatible with the 100G Datalogging FN remote ERT module. You may connect the Sensus Sonix meter to the ERT module using the pulse output cable or you can directly mount the ERT module to the meter. Sensus Sonix2000 Pulse Output Wiring Sensus Sonix2000 Pulse Output Options Option
(A) Pulse 1 (+)
(B) Pulse 2 (+) 1 2 Uncorrected LCD index volume Corrected Alarm
(C) Ground (-) TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 74 Proprietary and Confidential Sensus Sonix Meter Installation Direct Mounting the Remote ERT Module to the Sonix Meter The Sensus factory can direct mount the 100G Datalogging FN remote ERT module to Sensus Sonix Meters
(contact Sensus North American Gas Customer Service for mounting specifications and ordering information). This section includes the instructions for customers to mount the 100G Datalogging FN remote ERT module on the Sonix meter using the mounting materials available from Sensus Metering Systems. A Top anchor screw positions B Bottom anchor position for the endpoint U-shaped mount Sensus Sonix Direct Mount Brackets* and Mounting Hardware Sensus Part Number Description 60025-063-00000 1 1/2" FTP, 45Lt, #3 Spg, 60Lt, #4 Spg 60025-063-01000 2" - 11BS, 2" FTP 60025-063-02000 30Lt, #1A Spg, 1 1/4" NPT, #2 Spg, 20Lt 903376
#8-32 x 3/4" SS Fillister-head screws (2 required) 011-14-286-00 Rubber mounting washer Stabilizes bracket/100G Datalogging FN remote ERT module assembly
*Order the correct bracket for your installation requirements from Sensus North American Gas Customer Service. Brackets and mounting hardware are ordered separately. To direct-mount the 100G Datalogging FN remote ERT module on the Sonix meter 1. Place the endpoint mounting bracket over the inlet or outlet pipe fitting on the Sonix meter. (The default position is over the inlet connection - left side connection looking at the meter front.) 2. Remove the four endpoint backplate screws and turn the backplate so the endpoint mounting screw holes are to the top of the endpoint (the arrow on the endpoint label must point up). Secure with the four endpoint backplate screws previously removed. 3. Slide the mounting lug (now on the bottom of the endpoint) over the bottom anchor. Insert the two top endpoint mounting screws and tighten in an alternating fashion. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 75 Proprietary and Confidential Sensus Sonix Meter Installation Connecting the Remote ERT Module to a Sensus Sonix 600 or 880 Meter The 100G Datalogging FN remote ERT moduleprovides RF-based data collection for the Sonix 600 or 880 meter. To wire the 100G Datalogging FN remote ERT module to Sonix 600 and 880 meters Connect the Sonix 600 or 880 meter to the 100G Datalogging FN remote ERT module following the wiring diagram below. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 76 Proprietary and Confidential Sensus Sonix Meter Installation Programming the 100G Datalogging FN Remote ERT Module Caution You must program the 100G Datalogging FN remote ERT module before use. Follow the steps in this section to properly program the ERT module. Program the 100G Datalogging FN remote ERT modules using:
A FC200SR handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.3 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or A FC300 with SRead handheld computer with Endpoint-Link or Endpoint-Link Pro version 5.5 or higher or Field Deployment Manager (FDM) software version 1.1 or higher or A 900MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher or Field Deployment Manager
(FDM) software version 1.1 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. See the Endpoint-Link v5.3 (or higher) Endpoint Programming Guide (TDC-0744) or the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934) for more complete programming information. FC200SR FC300 with SRead 900MHz Belt Clip Radio TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 77 Proprietary and Confidential Sensus Sonix Meter Installation To program the 100G Datalogging FN remote ERT module 1. Program the meter drive rate into the 100G Datalogging FN remote ERT module using a handheld computer or Belt Clip Radio and laptop computer. For all programming and Check Endpoint operations using a handheld computer, hold the handheld as close to vertical as possible. For best success, keep the handheld within six feet of the target ERT module. Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the configuration file loaded into the programming device. During programming, the 100G Datalogging FN remote ERT module is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read to the nearest cubic foot. 2. Read or Check the ERT module using the handheld computer or Belt Clip Radio. If the read result is higher than the number programmed in step 1, the 100G Datalogging FN remote ERT module is counting correctly. If the read result is not higher than the number programmed in step 1, replace the 100G Datalogging FN remote ERT module. TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 78 Proprietary and Confidential Index Symbols & Numbers 100G Datalogging FN Remote ERT Module Meter Compatibility List, v, 3, 16, 34, 52, 66 100G Datalogging Remote Mount Gas Endpoint, 1 A Adapter Plate Mounting Positions, 12 B Before You Begin, v C Code Settings, 35, 36, 37, 38 Connecting the 100G Datalogging FN remote ERT module to the Romet ECM2 Meter, 28 Connecting the 100G Datalogging FN Remote Mount ERT Module to the IMC/W2 or MC2 Cable, 43 Connecting the Remote ERT Module to a DATTUS meter, 67, 69 Connecting the Remote ERT Module to a Sensus Sonix 600 or 880 Meter, 76 D DATTUS Meter Installation, 66 Diaphragm Meter Installation, 52 Direct Mounting the Remote ERT Module to the DATTUS Meter, 67, 68 I Index Cover Installation Required Materials, 60 Installation Options, 6 Installation Overview, 34, 66 Installation Prerequisites, 5, 25, 34, 52, 66 Installing 100G Datalogging FN Remote ERT Module Encoders, 55 Installing the 100G Datalogging FN Remote ERT Module, 54 Installing the 100G Datalogging FN Remote ERT Module with Sensus Sonix Meters, 74 Installing the ERT Module to the Dresser ROOTS Micro Corrector (IMC/W2 or MC2), 46 Installing the Remote ERT Module to Itron DATTUS Meters, 67 Installing the Remote ERT Module to the Elster American Meter RPM Series Rotary Meter, 21 Installing the Remote ERT Module to the Romet Electronically Compensated Meter (ECM2), 27 M Materials Available from Itron, 53 Mounting Installation Considerations, 7 Mounting Screw Specifications, 6 Mounting the 100G Datalogging FN Remote ERT Module, 6, 19, 34, 38, 70 Mounting the 100G Datalogging FN Remote Direct Mounting the Remote ERT Module to the Mount ERT Module, 27 Sonix Meter, 75 E Electronic Volume Corrector and Instrument Installation, 33 Mounting the ERT Module on a Wall or Other Flat Vertical Surface, 14 Mounting the Remote ERT Module on a Pipe, 8, 27 P Programming the 100G Datalogging FN Remote ERT Module, 31, 34, 50, 64, 67, 71, 77 TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 79 Proprietary and Confidential Programming the DATTUS Meter, 66 Programming the Mercury Instrument, 34, 35 Programming the Remote ERT Module for Dresser ROOTS Rotary Meters, 19 Programming the Sensus Sonix Meter, 73 R Related Documents, 2, 5, 52 Replacement Gaskets, 53, 60 Required Installation Materials Available from Itron, 17 Romet ECM2 Mounting Requirement, 28 Rotary Meter Installation, 16 S Sensus Sonix Meter Installation, 73 Specifications, 2 T To attach the ERT module to the IMC\W2 and MC2, 47 To install the 100G Datalogging FN remote ERT module on an Elster American RPM series meter, 22 To install the encoder, 56 To install the meter index covers over the 100G Datalogging FN remote ERT module encoder cable, 61 To make TCI pulse connections, 41 To mount the 100G Datalogging FN remote ERT module on a wall or other flat vertical surface, 14 To mount the 100G Datalogging FN remote ERT module on the Romet ECM2 meter, 29 To mount the 100G Datalogging FN remote ERT module on the adapter plate, 11 To mount the adapter plate on the pipe bracket, 10 To mount the pipe bracket on a vertical pipe, 8 To program the 100G Datalogging FN remote ERT module, 32, 51, 65, 72, 78 To remove the index, 55 To wire the 100G Datalogging FN remote ERT module to the Mercury Instrument, 34, 37 To wire the 100G Datalogging FN remote ERT module to Sonix 600 and 880 meters, 76 To connect the 100G Datalogging FN remote ERT To wire the 100G Datalogging FN remote ERT module to the IMC/W2 or MC2 cable, 44 module to the DATTUS meter, 69 To connect the 100G Datalogging FN remote ERT module cable assembly to the rotary meter, 18 To connect the manufacturer cable to the endpoint, 24 To install dual 100G Datalogging FN remote ERT modules to a Mercury Instrument Mini-Max Case Volume Corrector using Mercury Kit 22-
1077, 38 To install tamper seals and cable ties, 13, 15 To install the 100G Datalogging FN remote ERT module cable, 26 Tools and Materials Supplied By You, 52 Transmission Modes, 1 W Wiring Dual ERT Modules to a Mercury Instrument, 38 Wiring the ERT Module to the Instrument, 36 Wiring the Remote ERT Module to the Mercury TCI, 40 TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 80 Proprietary and Confidential
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2011-01-28 | 908 ~ 908 | DXT - Part 15 Low Power Transceiver, Rx Verified | Original Equipment |
2 | 903 ~ 926.8 | DSS - Part 15 Spread Spectrum Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2011-01-28
|
||||
1 2 | Applicant's complete, legal business name |
Itron Inc
|
||||
1 2 | FCC Registration Number (FRN) |
0005861034
|
||||
1 2 | Physical Address |
2401 N State Street
|
||||
1 2 |
Waseca, Minnesota 56093
|
|||||
1 2 |
United States
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
i******@ckccertification.com
|
||||
1 2 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
1 2 |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
|||||
app s | FCC ID | |||||
1 2 | Grantee Code |
EWQ
|
||||
1 2 | Equipment Product Code |
100GDLRN
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
J**** R****** H****
|
||||
1 2 | Title |
R&D Spectrum Regulatory
|
||||
1 2 | Telephone Number |
509-8********
|
||||
1 2 | Fax Number |
509-8********
|
||||
1 2 |
j******@itron.com
|
|||||
app s | Technical Contact | |||||
1 2 | Firm Name |
Itron, Inc.
|
||||
1 2 | Name |
J****** H******
|
||||
1 2 | Physical Address |
2401 N. State Street
|
||||
1 2 |
Waseca, Minnesota 56093
|
|||||
1 2 |
United States
|
|||||
1 2 | Telephone Number |
509-8********
|
||||
1 2 | Fax Number |
509-8********
|
||||
1 2 |
j******@itron.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DXT - Part 15 Low Power Transceiver, Rx Verified | ||||
1 2 | DSS - Part 15 Spread Spectrum Transmitter | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | AMR Transceiver device for utility meters | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
Itron, Inc
|
||||
1 2 | Name |
J**** H********
|
||||
1 2 | Telephone Number |
509-8********
|
||||
1 2 | Fax Number |
507-8********
|
||||
1 2 |
j******@itron.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 908.00000000 | 908.00000000 | ||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC | 903.00000000 | 926.80000000 | 0.3720000 |