Network Relay Point (NRP) NIC 540 Labeling Product Requirements Silver Spring Networks 555 Broadway Street Redwood City, CA 94063 www.silverspringnet.com Network Relay Point (NRP) NIC 540 Labeling Product Requirements 17 December 2015 DRAFT Silver Spring Networks 1 Network Relay Point (NRP) NIC 540 Labeling Product Requirements Confidential Information of Silver Spring Networks, Inc., provided under nondisclosure obligations. Copyright 2015 Silver Spring Networks, Inc. All rights reserved. The following are registered trademarks of Silver Spring Networks, Inc: the Silver Spring Networks name and logo, Altogether Brilliant, Connect to the Energy Network, CustomerIQ, GreenBox, GridScape, Micromesh, Power Over Energy, Silver Spring, Silver Spring Networks (and design), UtilityIQ, UtilOS. The following are trademarks of Silver Spring Networks, Inc: Connect to The Everything Network, EnergyIQ, Gen, GreenIQ, MicroAP, Milli, NetworkIQ, OPSIQ, Rings Logo, SensorIQ, SilverLink, Streetlight.Vision, The Internet of Important Things. All other company and product names are used for identification purposes only and may be registered trademarks, trademarks, or service marks of their respective owners. Please consider the environment before printing this document. Contact us. Email techpubs@silverspringnet.com with suggestions or corrections for this or any document. Customer Support Hours 5:00 AM - 6:00 PM US Pacific Time Telephone Toll free within the US and Canada:
1-888-SSN-9876
(1-888-776-9876) Non-toll-free: 1-650-839-4298 In Australia:
1300 706 769 Contact us on the Web: http://www.silverspringnet.com/services/customer-support/
9:00 AM - 9:00 PM Australia Eastern Time Email support@silverspringnet.com aus-support@silverspringnet.com Network Relay Point (NRP) NIC 540 Labeling Product Requirements 17 December 2015 DRAFT Silver Spring Networks 2 Network Relay Point (NRP) NIC 540 Labeling Product Requirements 2 About the Silver Spring Networks Network Relay Point (NRP) NIC 2 About the Silver Spring Networks Network Relay Point (NRP) NIC The Silver Spring Networks Network Relay Point (NRP) NIC 540 is a network interface card
(NIC) that enables machine-to-machine communication over 900 MHz and 2.4 GHz ISM bands. Figure 1. Silver Spring Network Relay Point (NRP) NIC540 Top view Bottom view References Guidelines for 64-bit Global Identifier (EUI-64) Registration Authority, IEEE Standards Association. Network Relay Point (NRP) NIC 540 Labeling Product Requirements 17 December 2015 DRAFT Silver Spring Networks 7 Network Relay Point (NRP) NIC 540 Labeling Product Requirements 2 About the Silver Spring Networks Network Relay Point (NRP) NIC NIC Address Labeling For radio identification, the street light equipment shall have an auxiliary label containing the Silver Spring Networks NIC address presented in text (16 alphanumeric digits) and bar code formats. Bar Code Type = Code 3 of 9 Bar Code Font Size = unknown Font Type = unknown Font Size = unknown Bar Code Label Dimensions = 1.0 x 1.5 Bar Code Material Type = Static Dissipative Polyimide Figure 2 shows an example of the NIC address label, which is consistent with FCC requirements set forth in FCC and Industry Canada Government Guidelines on page 3, and contains the Silver Spring Networks corporate name and NIC EUI-64 address. Figure 2. Example of NIC address label for NIC 540 Silver Spring Networks 1234567890123456 Contains:
FCC ID: OWS-NIC541 IC: 5975A-NIC541 NIC Labeling The Silver Spring Networks Network Relay Point (NRP) NIC has a label relevant to a NRP final assembly and RMA: the FCC and Part Number label and the Silver Spring NIC address label. Both labels are located on the bottom side of the NIC PCA. The FCC ID label is 1 x .375 inches (2.5 x 1 cm). Figure 3 shows an example of the FCC ID label found on the NRP NIC. Figure 3. FCC ID label for NRP NIC Model No: NIC 541-0302 FCC ID: OWS-NIC541 IC:5975A-NIC541 Network Relay Point (NRP) NIC 540 Labeling Product Requirements 17 December 2015 DRAFT Silver Spring Networks 8 Network Relay Point (NRP) NIC 540 Labeling Product Requirements 2 About the Silver Spring Networks Network Relay Point (NRP) NIC Figure 4 shows the placement of the labels. Figure 4. Label locations on the Silver Spring NRP NIC Silver Spring MAC address and part number Catalog number Model number FCC ID IC Certification Network Relay Point (NRP) NIC 540 Labeling Product Requirements 17 December 2015 DRAFT Silver Spring Networks 9 Network Relay Point (NRP) NIC 540 Labeling Product Requirements 2 FCC and Industry Canada Government Guidelines 2 FCC and Industry Canada Government Guidelines Silver Spring Networks NRP NIC FCC ID: OWS-NIC541 IC: 5975A-NIC541 Requirements The Silver Spring Network Relay Point (NRP) network interface card (NIC) is REQUIRED to be professionally installed by a properly trained technician. Improper installation could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. The antenna of this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The device should be installed so that people will not come within the specified distance of the antenna as listed below. US installations: The device should be installed so that people will not come within 23 cm (9 in.) of the antenna. Canada installations (IC): The device should be installed so that people will not come within 34 cm (13.4 in.) of the antenna. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This equipment has been tested and found to comply with Part 15 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception (which can be determined by turning the equipment off and on), the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Network Relay Point (NRP) NIC 540 Labeling Product Requirements 17 December 2015 DRAFT Silver Spring Networks 3 Network Relay Point (NRP) NIC 540 Labeling Product Requirements 2 FCC and Industry Canada Government Guidelines Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Exigences d'Industrie Canada La carte dinterface rseau (NIC) Silver Spring Network Relay Point (NRP) DOIT tre installe par un technicien ayant reu une formation adquate. Une installation incorrecte peut annuler lautorisation de lutilisateur se servir de lquipement. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Lantenne de cet metteur ne doit pas se trouver proximit de ou fonctionner en association avec une autre antenne ou un autre metteur. Lappareil doit tre install de telle sorte que les gens ne viendront pas au sein de 34 cm (13.4 in.) De lantenne Les changements ou modifications apports sans lapprobation expresse de lautorit responsable de la conformit pourront entraner lannulation de lautorisation dutilisation de cet quipement. FCC and Industry Canada Guidelines for Devices Containing a Transmitter Module The following is an extract from FCC PART 15 UNLICENSED MODULAR TRANSMITTER APPROVAL, DA 00-1407, Released: June 26, 2000, Section 6 describing labeling requirements for devices containing a modular transmitter. Section 6. The modular transmitter must be labeled with its own FCC ID number, and, if the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: Contains Transmitter Module FCC ID: XYZMODEL1 or Contains FCC ID:
XYZMODEL1. Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an example of which must be included in the application for equipment authorization, or, must provide adequate instructions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. The following is an extract from RSS-GEN, General Requirements and Information for the Certification of Radio Apparatus, Section 3.2.1, describing labeling requirements for a host device integrating a radio module. Network Relay Point (NRP) NIC 540 Labeling Product Requirements 17 December 2015 DRAFT Silver Spring Networks 4 Network Relay Point (NRP) NIC 540 Labeling Product Requirements 2 FCC and Industry Canada Government Guidelines The host device shall be properly labelled to identify the modules within the host device. The Industry Canada certification label of a module shall be clearly visible at all times when installed in the host device, otherwise the host device must be labelled to display the Industry Canada certification number of the module, preceded by the words Contains transmitter module, or the word Contains, or similar wording expressing the same meaning, as follows:
Contains transmitter module IC: XXXXXX-YYYYYYYYYYY where XXXXXX-YYYYYYYYYYY is the modules certification number. Lextrait suivant provient du Cahier des charges sur les normes radiolectriques (CNR);
exigences gnrales et information relatives la certification des appareils radio, section 3.2.1, et dcrit les exigences en matire dtiquetage pour un dispositif hte intgrant un module radio. Le dispositif hte doit tre correctement tiquet afin didentifier les modules quil comprend. Ltiquette de certification Industrie Canada dun module doit toujours tre bien visible lors de linstallation sur un dispositif hte. Dans le cas contraire, le dispositif hte doit tre tiquet de faon afficher le numro de certification Industrie Canada du module, prcd de lexpression Contains transmitter module ou du mot Contains , ou dune formulation similaire ayant la mme signification. Par exemple :
Contains transmitter module IC : XXXXXX-YYYYYYYYYYY o XXXXXX-YYYYYYYYYYY reprsente le numro de certification du module. The applicant for equipment certification of the module shall provide with each unit of the module either a label such as described above, or an explanation and instructions to the user as to the host device labelling requirements. Figure 1. Sample FCC ID label for devices containing a NRP (NIC540) Contains FCC ID: OWS-NIC541 IC: 5975A-NIC541 NIC 540 External Antenna Integration This radio transmitter 5975A-NIC541 has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Omnidirectional antennas: 6 dBi at 900 MHz, 6 dBi at 2.4 GHz Network Relay Point (NRP) NIC 540 Labeling Product Requirements 17 December 2015 DRAFT Silver Spring Networks 5 Network Relay Point (NRP) NIC 540 Labeling Product Requirements 2 FCC and Industry Canada Government Guidelines Le prsent metteur radio 5975A-NIC541 (identifier le dispositif par son numro de certification ou son numro de modle sil fait partie du matriel de catgorie I) a t approuv par Industrie Canada pour fonctionner avec les types dantenne numrs ci-
dessous et ayant un gain admissible maximal et limpdance requise pour chaque type dantenne. Les types dantenne non inclus dans cette liste, ou dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour lexploitation de lmetteur. Antennes omnidirectionnelles: 6 dBi 900 MHz, 6 dBi 2.4 GHz Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformment la rglementation dIndustrie Canada, le prsent metteur radio peut fonctionner avec une antenne dun type et dun gain maximal (ou infrieur) approuv pour lmetteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique lintention des autres utilisateurs, il faut choisir le type dantenne et son gain de sorte que la puissance isotrope rayonne quivalente (p.i.r.e.) ne dpasse pas lintensit ncessaire ltablissement dune communication satisfaisante. Safety Information XXX WARNING: Severe shock and explosion hazard! Touching energized parts can result in massive equipment damage, and severe injury or death. Short-circuiting energized parts will result in blinding flash and explosion. Opening and closing electrical circuits can also produce dangerous and explosive arc flashes. Involuntary muscular reactions associated with electrical shock may result in other injuries. Observe the following safety guidelines. Careful planning of every job is essential. Nothing should be taken for granted. Do not take chances!
Read and follow all approved policies and procedures provided by your employer associated with the procedures in this manual. The procedures in this manual must only be performed by qualified workers in accordance with local utility safety practices, utility requirements, and applicable OSHA and NFPA standards. The information contained in this document is intended to aid qualified personnel, and is not a replacement for the proper training required to make a person qualified. Silver Spring Networks assumes no liability for the customers failure to follow these safety guidelines. General Electrical Safety Perform the procedures in this manual in accordance with applicable workplace standards established by the following agencies:
Occupational Safety and Health Act (OSHA). Network Relay Point (NRP) NIC 540 Labeling Product Requirements 17 December 2015 DRAFT Silver Spring Networks 6 Network Relay Point (NRP) NIC 540 Labeling Product Requirements 2 FCC and Industry Canada Government Guidelines The National Electrical Code published by the National Fire Protection Association
(NFPA-70). National Electrical Manufacturers Association (NEMA). Electronics Industries Association (EIA). Insulated Power Cable Engineers Association (IPCEA). American National Standards Institute (ANSI). Whenever possible, de-energize all circuits or equipment before working on them. Maintain a minimum clearance of 10 feet (3 meters) between line potential and all unqualified persons at all times. Keep unauthorized people out of the work area. Be especially cautious of children, who tend to be drawn to work activity. Determining if a circuit is OFF can be difficult in some instances. Check for circuit voltage with an appropriate voltmeter before working on equipment presumed to have been de-
energized. Tiebreakers, double throw disconnect switches, automatic transfer switches and emergency generators can supply power through an alternate circuit or from another source. 120V current can be just a lethal as higher voltages because current flow through a body depends upon the bodys resistance. Do not trust insulation and/or weatherproofing on a wire as protection from shock. Use electrically insulated tools. Inspect portable electrical equipment or tools for defects and remove any defective devices from service immediately. All portable electrical equipment must have Ground Fault Circuit Interrupter (GFCI) protection. Select the right tool for the job. Use tools properly. Keep tools in good working order. Make sure the work area is free of any flammable material. Flammable vapors can be ignited by an arc flash. Keep the work area clean and dry. Cluttered work areas cause accidents and injuries. Provide good lighting in the work area. You cannot work safely if you cannot see what you are doing. Report unsafe conditions or defective equipment to your immediate supervisor. Handle material carefully. Lift and carry properly. Network Relay Point (NRP) NIC 540 Labeling Product Requirements 17 December 2015 DRAFT Silver Spring Networks 7