ATLANTA project Atlanta13,Atlanta14,Atlanta15,Atlanta16,Atlanta17,AtlantaB1, AtlantaB2 Revision Description Originator Date Atlanta User Manual Amanda Mora 3/3/2020 A Disclaimer Information in this document is provided in connection with Hyve Solutions (Manufactured by Jabil) products. Hyve Solutions (Manufactured by Jabil) assumes no liability whatsoever, Hyve Solutions (Manufactured by Jabil) disclaims any express or implied warranty, relating to sale and/or use of Hyve Solutions (Manufactured by Jabil) products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Hyve Solutions (Manufactured by Jabil) products are not designed, intended or authorized for use in any medical, lifesaving, or life sustaining applications or for any other application in which the failure of the Hyve Solutions (Manufactured by Jabil) product could create a situation where personal injury or death may occur. Hyve Solutions (Manufactured by Jabil) may make changes to specifications and product descriptions at any time, without notice. Copyright 2016, Hyve Solutions (Manufactured by Jabil). All Rights Reserved. 1 Warnings 2 3 4 5 6 7 8 9 10 11 12 Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products/components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold. System power on/off: The power buttons DOES NOT turn off the system AC power. To remove power from the system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components. Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result. Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts. ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. CLASS I PLUGGABLE EQUIPMENT TYPE A:
- Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til stikproppens jord
- Laite on liitettv suojakoskettimilla varustettuun pistorasiaan
- Apparatet m tilkoples jordet stikkontakt
- Apparaten skall anslutas till jordat uttag Caution Battery: Lithium battery included with this server. Do not puncture, mutilate, or dispose of battery in fire. You will run the risk of an explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used battery accordingly to the manufacturers instructions and in accordance with your local regulations. Service: Only trained personnels should install, service or replace parts in this server. The server is for restricted access only. Power Supply: The power supply in this server has no user serviceable parts. If the power supply is defective, return the unit for service. DC operated Server: Since this server is DC operated, it will be auto booted up when the server connects to DC power bus bar at the back of Rack. The power button is provided on I/O panel for server ON-OFF services. For unscheduled service, unplug the server from Rack will power off the server. For scheduled services, there are 2 ways to shut off the server DC power. The 1st way is to press the power button for about 10 seconds for server to activate its power off sequence. The 2nd way is to issue a Linux command to gracefully shut down the server for servicing. 13 Regulatory Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Self-declaration conforming to IS XXXXX, R XXXXX CE Complies to EN 55032, EN 552024 and EN 60950-1. A (Class-A Product Declaration) A ITE, We declare here that the subject product is Class-A ITE product, and the following statement is clearly marked in the user manual and nameplate A WARNING This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 14 FCC VCCI INDIA Additional Information Contact Jabil 1565 S. Sinclair Street Anaheim, CA 92806, USA https://www.jabil.com/
FCC ID: 2AVRG-ATLANTA Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. IC: 25886-ATLANTA IC This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. Lappareil ne doit pas produire de brouillage;
2. Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. 15 16 1.0 Model Specification Table One Unit SERVER UNIT M/B CPU The SERVER will be used with the Rack. Flex MP-10033750-000 Intel Xeon 8151 3.4G MAX4G, LGA-3647(3647pins) COUNT:2 MICRON MTA36ASF4G72PZ-2G6E1S1*24 Delta GF0412SS-03*10 SAMSUNG PM883 240G SSD*1 PM983 7.68T*8 Annapurna NVME Card (control SSD) K2X-AB*4 Annapurna 25G QSFP Port Network Interface Card K2X-N USB 3.0 port*1 RJ45 MGMT PORT*1
(10 Mpbs/100Mpbs/1Gbps) QSFP Port *2 RJ45 PORT*2(Used for Setting Function) Smart Approach SM-MFAD4-C02 NFC MODULE(13.56MHZ) DIMM FAN SSD Card Card I/O USB LAN RF 17 RJ45 Port
(Used for Setting Function) QSFP Port*2 RJ45 Port
(Used for Setting Function) I/O port RJ45 port(MGMT) VGA PORT DC POWER INPUT 18 Rack View When Power Shelf insert the RACK (INTO TO BUS Bar) The Bus bar will have 12VDC When server insert in the Rack Bus Bar, the one server will also get 12DV for trun on 19 Built with an NFC sensor to communicate with NFC tags for server authentication NFC CABLE TO CONNECT CARD NFC MODULE AND TAG 20 1.1 NFC DATASHEET 21