Wireless LAN JRL-710AP3R Manual G l o b a l C o m m u n i c a t i o n s http://www.jrc.co.jp Please read a user's manual about the command for setting change, display, and examination of this equipment. 2/12 Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. CAUTION Compliance statement and notification Declaration of Conformity Product Name: Wireless Lan Model Number: JRL-710AP3R This device complies with Part 15 of FCC Rules and RSS-Gen of IC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of this device.
<FCC / IC>
RF exposure compliance:
This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequencyRFExposure Guidelines in Supplement C to OET65 and RSS-102 of the IC radio frequencyRF Exposure rules. This equipment has very low levels of RF energy that it deemed to comply without maximum permissive exposure evaluationMPE. But it is desirable that it should be installed and operated keeping the radiator at least 20cm or more away from persons bodyexcluding extremities: hands, wrists, feet and ankles. 3/12
< FCC >
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an AC outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. In according with 47 CFR Part15.407 (e) U-NII devices operating in 5.15-5.25GHz frequency bands are restricted to indoor operations only. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.
< IC >
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause Undesired operation of the device. Canada, avis d'Industry Canada (IC) Cet appareil numrique de classe B est conforme aux normes canadiennes ICES-003 et RSS-210. Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d'interfrence et (2) cet appareil doit accepter toute interfrence, notamment les interfrences qui peuvent affecter son fonctionnement. Informations concernant l'exposition aux frquences radio (RF) La puissance de sortie mise par lappareil de sans fil est infrieure la limite d'exposition aux frquences radio d'Industry Canada (IC). Utilisez lappareil de sans fil de faon minimiser les contacts humains lors du fonctionnement normal. Ce priphrique a galement t valu et dmontr conforme aux limites d'exposition aux RF d'IC dans des conditions d'exposition des appareils mobiles (les antennes se situent moins de 20 cm du corps d'une personne). 4/12
<R&TTE>
CE Marking:
Please describe the following sentences to the label or the user manual of the product in each language in the sales country:
Hereby, Japan Radio CO., Ltd. declares that this JRL-710AP3R is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. 5/12 The name of each part Front side P W R T X /R X W -L IN K E -L IN K Remarks If a power supply is supplied to this equipment, the light will be switched on in "green."
"Orange": Switch on the light during transmission.
"Green": Switch on the light during reception. In STA, lighting "green" and "orange" is periodically repeated during AP search. The light is switched on while STA connects with AP. The light is switched on during STA connection by "orange":AP setup. The light is switched on during AP connection by "green":STA setup. The light is switched on when EtherNet links.
"Orange" : The light is switched on in LINK as 10BASE-T.
"Green" : The light is switched on in LINK as 100BASE-TX. Name PWR TX/RX W-LINK E-LINK Back side A N T 1 A N T 2 1 0 /1 0 0 B A S E -T C L R C O N S O L E D C +5 V 6/12 Remarks It is a connector which connects an antenna.Main It is a connector which connects an antenna.Sub It is a connector which connects maintenance PC. It is a connector which connects Ethernet. A power supply is connected and a power supply is supplied to equipment. This connection is unnecessary when supplying a power supply by PoE. It is a switch which initializes a setup. The power supply of this equipment is switched on pushing the "CLR" button. If it is continuing pushing the "CLR" button, the "PWR"
lamp will change from "green" to "orange" for 1 second. Then, equipment returns to initial setting. Name ANT1 ANT2 CONSOLE 10/100BASE-T DC +5V CLR Login The IP address initial value of wireless LAN is set as "192.168.1.1/24."
Here, the login method in case the IP address of this equipment is
"192.168.1.1/24" is shown. Please read a user's manual about the command for setting change,a display, and an examination of this equipment. Login PC which logs in to this equipment is prepared. The IP address of PC is changed into "192.168.1. x/24" so that PC can communicate with this equipment. However, the value of "x" is 2 to 254. PC If a setup of PC is completed, this equipment will be connected with PC by cable. If it connects with PC normally, the "E-LINK" lamp will light up. 1 User account The following user names and passwords are set up in the initial state. Please change a password at the time of the first login for security protection. User name admin user Setting change / setting display Setting change (only password) / setting display admin user Authority Password 7/12 2 Login It logs in to this equipment using a WEB browser. If
"http://192.168.1.1" is inputted into the address of a WEB browser, it will connect with this equipment and will display the following login windows. A user name is inputted. adminuser A password is entered. The entered password is displayed by "*."
Login windows A top screen will be displayed if it succeeds in login. Now, login to this equipment is completion. Please read a user's manual about the command for setting change,a display, and an examination of this equipment. Top screen 8/12 Specification 1. General 1) Input Power 2) Frequency Range 3) Radio Communication Standard : IEEE802.11a/b/g 4) Operating Temperature 5) Power Consumption
: -30 to +65 degree C
: Less than 5W
: DC IN; DC 5V+/-5%
IEEE802.3af; DC48V (36 to 57V)
: 2.4GHz ISM band (2412 to 242MHz) 5GHz bandW525150 to 5250MHz 2. Electrical Specification 1) Output Power
: 8mW/MHz +20%, -80%2.4GHz band 3mW/MHz +20%, -80%5GHz bandW52 2) Number of Channel
2.4GHz band; 13-channels CH1: 2412MHz, CH2: 2417MHz, CH3: 2422MHz, CH4: 2427MHz, CH5: 2432MHz, CH6: 2437MHz, CH7: 2442MHz, CH8: 2447MHz, CH9: 2452MHz, CH10: 2457MHz, CH11: 2462MHz 5GHz band; 4-channels CH36:5180MHz, CH40:5200MHz, CH44:5220MHz, CH48:5240MHz, 20MHz5GHz bandW52
: DSSS/OFDM
: Carrier Sense Multiple Access (CSMA)
: 5MHz2.4GHz band 3) Channel Separation 4) Modulation 5) Access Method 6) Variable method of Transmission rate i) IEEE802.11b mode i) IEEE802.11ag mode 6,9,12,18,24,36,48,54Mbps
: 1,2,5.5,11Mbps
: Automatic
: Fixed : 1,2,5.5 or 11Mbps
: Automatic
: Fixed : 6,9,12,18,24,36,48, or 54Mbps 9/12
: Less than 26MHz2.4GHz band 7) Band Width Less than 19MHz5GHz bandW52
: IEEE802.3 (CSMA/CD), 10/100Base-T 8) Wire connection interface 9) Antenna Impedance 10) Number of Terminal Capacity a. Wireless Terminal b. Wired Terminal
: 127 terminals
: 1024 terminals
: 50ohms 1) Antenna Connector 3. Mechanical Specification 2) 10/100Base-T Connector 3) Antenna Connection Port Diversity) 4) LED Indicator 5) Clear Key (Reset) Switch 6) Dimension 7) Weight 4. Support Function
: SMA-RP
: RJ-45
: Two
(2) port
(One is for
: a) Main power indicator b) Tx/Rx indicator c) Wireless LAN link indicator d) Wired LAN link indicator
: Factory default mode
: Approx. 400g
: 121(W) x 32.8(H) x 100.5(D) mm 1) Wireless Bridge 2) Roaming 3) SNMP (Simple Network Management Protocol) 4) Remote Monitoring 5) WEB Log In 6) Telnet Log In 7) Diagnostic Command 10/12 5. Security 1) 32 Characters ESSID (Extended Service Set ID) 2) Any ID Cancellation 3) SSID Stealth (Mask in Beacon) 4) MAC Address Filtering 5) Access Filter 6) WEP (Wired Equivalent Privacy) RC4 Algorithm (40/104/128bits) 7) WPA (Wi-Fi Protected Access)-PSK 8) Packet Filter 9) IEEE802.11i i) TKIP ii) AES 6. Outline Drawing C O N S O L E 2M4 Depth-8 11/12 2.4 GHz/5.2GHz band wireless LAN module JRL-710AP3R February 1, 2013 Do not copy Japan Radio Co., Ltd. Mobile communication group 1-1 SHIMORENJAKU 5 CHOME, MITAKA-SHI, TOKYO, JAPAN Tel +81-422-45-9236Fax +81-422-45-9880 12/12