READ IT OR WATCH IT Read instructions or watch easy-to-follow video. Scan QR code or visit goo.gl/NX4SRq FCC Any changes or modifications not expressly approved by the party responsible for compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure: A distance of 20 cm shall be maintained between the antenna and users, and the transmitter module may not be co-located with any other transmitter or antenna. Caution:
could void the users authority to operate this equipment NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Radiation Exposure Statement This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. SPECIFICATIONS Power: 120VAC, 60Hz Signal (Frequency): 908.4/916MHz Maximum loads: 600W, 2-gang 500W or 3-gang 400W incandescent, 150W or 2A CFL/LED Operating temperature range: 32-104 F (0-40 C) For indoor use only. Specications subject to change without notice due to continuing product improvement. WARNING RISK OF FIRE RISK OF ELECTRICAL SHOCK RISK OF BURNS CONTROLLING APPLIANCES CAUTION: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE, MOTOR-OPERATED APPLIANCE, FLUORESCENT LIGHTING FIXTURE, OR A TRANSFORMER-
SUPPLIED APPLIANCE. ONLY USE TO CONTROL INCANDESCENT OR DIMMABLE CFL/
LED BULBS DO NOT EXCEED RATINGS DO NOT USE TO CONTROL ANY DEVICE WHERE UNINTENDED OPERATION COULD CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.) FOR INDOOR USE ONLY WARNING SHOCK HAZARD Turn OFF the power to the branch circuit for the dimmer and lighting xture at the service panel. All wiring connections must be made with the power OFF to avoid personal injury and/or damage to the dimmer. This device is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada. If you are unsure or uncomfortable about performing this installation, consult a qualied electrician. 1. Required tools IMPORTANT!
The xture controlled by the Wi-Fi Smart Dimmer must not exceed 600W (incandescent); 150W dimmable CFL/LED. Getting to know your new Wi-Fi Smart Dimmer Turn ON/OFF manually or through the myTouchSmart app Compatible with Amazon Alexa and Google Home May be used in single-pole installation or 3-way wiring congurations Compatible with all incandescent and most dimmable CFL/LED bulbs Interchangeable rocker paddle white & light almond included Uses a standard, decorative-size wallplate for single-gang installations (wallplate not included) Screw terminal installation requires wiring connections for line (hot), load, neutral and ground. Traveler wire required for 3-way installation 40794 v1 02/22/19 2. A B C D E G H F A. Ground (Green/Bare) B. Load (Black) C. Line (Black) D. Traveler (Red/Other) E. Neutral (White) F. Air Gap Switch Removes power from dimmer. G. Top rocker Press &
release to turn dimmer ON, press & hold increases brightness Press & release to turn device ON. Press &
hold for 10 seconds to reset Wi-Fi device to factory specs H. Bottom rocker Press
& release to turn dimmer OFF, press & hold to dim 3. TOP To change the paddle This step is optional. Before installation, you may want to change the color of the paddle to match your wallplate or dcor. 1. Insert a small, at-
blade screwdriver into either groove at the top of the paddle, and apply gentle pressure to remove the paddle. 2. Align the new paddle with the bottom of the Wi-Fi device and press it into place. Single-switch wiring Removing existing switch Before installation, you may wish to change the paddle color to match your wallplate or dcor. Please return to section 3. A. Shut off power to the circuit at circuit breaker or fuse box. IMPORTANT! Verify power to switch box is OFF before continuing. B. Remove wallplate. C. Remove the switch mounting screws. D. Carefully remove the switch from the switch box. DO NOT disconnect the wires. 5. Typical wiring schematic for 3-way Installation Line side (hot) Ground Line Load side Load H H C 3-way dimmer wiring IMPORTANT!
3 -way switches can be wired in different ways. These instructions explain the most common method. If you have difculty with the instructions or your home wiring, contact a licensed electrician for assistance. 1. Shut off power to the circuit breaker or fuse box. IMPORTANT! Verify power to switch is OFF before continuing. 2. Remove line side wallplate. 3. Remove mounting screws to existing line side switch. H H C In-Wall Wi-Fi Smart Dimmer MTS5406, MTS5407 FCC ID: QOB-MTS5406 MADE IN CHINA GE IS A TRADEMARK OF GENERAL ELECTRIC COMPANY AND IS UNDER LICENSE BY JASCO PRODUCTS COMPANY LLC, 10 E. MEMORIAL RD., OKLAHOMA CITY, OK 73114. This Jasco product comes with a 1-year limited warranty. Visit www.byjasco.com for warranty details. Questions? Contact our U.S.-based Consumer Care at 1-800-654-8483 between 7AM8PM CST. 4. OROR A B D F G C E B A C D E Insert wires into holes, do not wrap wires around screws. Do not remove screws. Out to light (load) LOAD GROUND TRAVELER NEUTRAL LINE From breaker box From breaker box H Up to ve screw terminals on the switch are marked:
a. GROUND Green/Bare. b. LOAD Black (connected to lighting). c. LINE (Hot) Black (connected to power). d. TRAVELER Red. e. NEUTRAL White. Match these screw terminals to the wires connected to the existing switch. E. Disconnect the wires from the existing switch. Label wires according to the previous terminal connection. Installation Wire strip length:
Strip insulation for attachment 5/8in. (16mm). UL species the tightening torque for the screws is 12lbf-in (14Kgf-cm). F. Connect the green or bare copper ground wire to the ground terminal. I. Connect the black wire from the light to the load terminal. II. Connect the black wire from the electrical service panel (hot) to the line terminal. III. Connect the white wire to the neutral terminal. Use a jumper wire if needed. Often, the neutral wire can be found in the back of the switch box. There may be several neutral wires bound together with a wire nut. Note: The traveler terminal is only used for 3-way installations. IV. Insert dimmer into the switch box being careful not to pinch or crush wires. G. Secure the switch to the box using the supplied screws. H. Reapply power to the circuit at fuse box or circuit breaker. The blue indicator light under the ON/OFF paddle should blink rapidly. If the blue light is not blinking, rst ensure the air gap switch is in ON position (right). If the blue light is still not blinking, turn off the breaker, verify there is no power to the Wi-Fi dimmer, switch the wires in the line and load terminals, and tighten the screws. Mount the wallplate and reapply power to the circuit at fuse box or circuit breaker. In a typical 3-way application, there are two 3-way switches. The switch on the line (hot) side has the common terminal tied to 120VAC. The switch on the load side has the common terminal tied to the load the switches turn ON/OFF. Line side Figure 1 - Line side switch before Figure 2 - Line side after Ground 4 Line H 2 H C 3 1 Ground Line H 2 H C 4 5 2 1 3 1. Black wire/black screw - line 2. Red wire/brass screw - traveler 1 3. Black wire/brass screw - traveler 2 4. Copper wire/green screw - ground 1. Black wire (line) to wire nut 2. Red wire (traveler 1) to brass screw 3. Black wire (traveler 2) to wire nut 4. Green/copper wire - ground 5. White jumper to wire nut/black screw Load side Insert wires into holes, do not wrap wires around screws. Do not remove screws. Figure 3 - Load side switch before Figure 4 - Load side switch after (Wi-Fi) Load Load 4 H 3 H C 2 1 1. Black wire/black screw - load 2. Red wire/brass screw - traveler 1 3. Black wire/brass screw - traveler 2 4. Green/copper wire - ground D N U O R G D A O L E N I L R E L E V A R T L A R T U E N Load Traveler 2 Neutral Ground Traveler 1 1 3 5 4 2 4. Carefully remove switch from switch box. DO NOT disconnect wires yet. 5. Identify black wire (line) connected to circuit breaker, attached to black screw. Label wire line. 6. Identify red wire (typically) also connected to load side, attached to other brass screw. Label traveler 1. 7. Identify black wire connected to load side, attached to brass screw. Label wire traveler 2. Prepare line side for new 3-way connection 1. Disconnect black wire marked line from the black screw and the other black wire labeled traveler 2 from brass screw. 2. Use the provided wire nut to connect the two black wires with one of the included white jumper wires. 3. Connect the free end of the white jumper wire to the black screw (hot) on the existing switch. 4. Carefully replace the switch back into the switch box. Ensure the wires are not pinched or crushed. Secure the switch using the mounting screws. Installing the Wi-Fi dimmer on the load side 1. Remove load side wallplate. 2. Remove existing switch from load side switch box. DO NOT disconnect wires yet. 3. Identify black wire connected to the load (light xture) attached to black screw. Label as load. 4. Identify red wire from line side, attached to bass screw. Label wire traveler 1. 5. Identify black wire coming from line side. Label wire traveler 2. 6. Locate neutral wires inside switch box. Connect the other included white jumper wire to neutral wire bundle. Label wire neutral. 7. Disconnect black wire labeled load and connect to load terminal on Wi-Fi dimmer. 8. Disconnect red wire labeled traveler 1 and connect to traveler terminal on Wi-Fi terminal. 9. Disconnect black wire labeled traveler 2 and connect to line terminal on Wi-Fi dimmer. 10. Connect free end of white jumper wire to neutral terminal on Wi-Fi dimmer. 11. Disconnect green or copper wire and connect to ground terminal on Wi-Fi dimmer. 12. Carefully place the Wi-Fi dimmer back into the switch box. Ensure the wires are not pinched or crushed. Secure in place using the mounting screws. 13. Turn on circuit breaker or fuse box. 14. Verify the blue indicator LED on Wi-Fi dimmer blinks rapidly. If the blue light is not blinking, rst ensure the air gap switch is in ON position
(right). If the blue light is still not blinking, turn off the breaker, verify there is no power to the Wi-Fi dimmer, switch the wires in the line and load terminals, and tighten the screws. Mount the wallplate and reapply power to the circuit at fuse box or circuit breaker. les changements ou modifications non expressment approuve par le responsable de la FCC ce dispositif est conforme la partie 15 des rgles de la fcc.lopration est soumise deux conditions:
(1) este dispositivo no debe provocar interferencia perjudicial, y (2) este dispositivo debe aceptar toda interferencia que reciba, incluso la que pudiera causar un funcionamiento no deseado. RF dexposition: une distance de 20 cm doit tre maintenue entre lantenne et les utilisateurs, et lmetteur module ne peut pas tre install avec tout autre metteur ou dune antenne. attention:
conformit pourrait vider lutilisateur est habilit exploiter ce matriel. NOTA: Este equipo ha sido probado y cumple con los lmites para aparatos digitales de Clase B, de conformidad con el apartado 15 de las normas de la FCC. Estos lmites estn diseados para proveer proteccin razonable contra interferencias perjudiciales en una instalacin residencial. Este equipo genera, usa y puede irradiar energa de radiofrecuencias y, si no se instala y usa segn las instrucciones, puede provocar interferencia perjudicial a las radiocomunicaciones. No obstante, no hay garantas de que no ocurrir interferencia en una instalacin en particular. Si este equipo provoca interferencia perjudicial a la recepcin de radio o televisin, lo que puede determinarse encendiendo y apagando el equipo, se recomienda que el usuario intente corregir la interferencia por medio de la implementacin de una o ms de las siguientes medidas:
Reorientar o reubicar la antena receptora. Incrementar la separacin entre el equipo y el receptor. Conectar el equipo a un tomacorriente de un circuito diferente del circuito al que est conectado el receptor. Consultar al distribuidor o a un tcnico con experiencia en radio/televisin para solicitar asistencia. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada Dclaration dexposition aux radiations Cetquipementestconforme Canada limitesdexposition aux radiations dans un environnement non contrr?l. Cetquipementdoittreinstall et utilis distance minimum de 20cm entre le radiateur et votre corps. ADVERTENCIA RIESGO DE INCENDIO RIESGO DE DESCARGA ELCTRICA RIESGO DE QUEMADURAS CONTROL DE EQUIPOS ELECTRODOMSTICOS PRECAUCIN: A FIN DE DISMINUIR EL RIESGO DE RECALENTAMIENTO Y DE POSIBLES DAOS EN LOS DEMS EQUIPOS, NO INSTALAR PARA CONTROLAR APARATOS QUE FUNCIONAN A MOTOR, ARTEFACTOS DE ILUMINACIN DE LUZ FLUORESCENTE O APARATOS ALIMENTADOS CON TRANSFORMADORES. USAR EXCLUSIVAMENTE PARA CONTROLAR BOMBILLAS CFL/LED INCANDESCENTES O ATENUABLES NO SUPERE LOS VALORES NOMINALES ELCTRICOS NO USAR PARA CONTROLAR DISPOSITIVOS USE SOLAMENTE EN INTERIORES ESPECIFICACIONES Alimentacin: 120VAC, 60Hz. Seal (frecuencia): 908.4/916 MHz Cargas mximas: 600W, Caja para 2 conexiones 500W,Caja para 3 conexiones 400W slo las lmparas incandescente 150W o 2A CFL/LED Rango de temperatura de funcionamiento:
32-104 F (0-40 C). Para uso en espacios interiores solamente. Especicaciones sujetas a cambio sin aviso debido a continuas mejoras del producto. ADVERTENCIA DESCARGA ELCTRICA Interrumpa el suministro de corriente al circuito del atenuador y al artefacto de iluminacin desde el panel de servicio. Interrumpa el suministro de corriente al circuito del atenuador y al artefacto de iluminacin desde el panel de servicio. Todas las conexiones de cableados deben realizarse con la alimentacin interrumpida para evitar lesiones personales o daos al atenuador de luz.Este dispositivo est diseado para la instalacin conforme al Cdigo de Normas de Electricidad y las reglamentaciones locales en EE. UU. o el Cdigo de Normas de Electricidad y las reglamentaciones locales en Canad. Si no est seguro o tiene dudas sobre cmo realizar la instalacin, contacte a un electricista profesional. 1. Herramientas necesarias IMPORTANTE!
El accesorio controlado por el atenuador inteligente con wi no debe ser superior a 600 W (iluminacin incandescente);
150 W atenuable CFL/LED. Caractersticas principales de su nuevo atenuador de luz inteligente con wi ENCENDER/APAGAR y regular los niveles de atenuacin, manual o remotamente a travs de la aplicacin myTouchSmart Compatible con Amazon Alexa y Google Home Se puede utilizar en una instalacin monofsica o en conguraciones de cableado de 3 vas Compatible con todas las bombillas incandescentes y la mayora de las bombillas atenuables CFL/LED. Paleta oscilante intercambiable: se incluye el blanco y el almendra claro. Utiliza una placa de pared estndar y decorativa para instalaciones de conexin sencilla (de salida nica) (la placa de pared no est incluida) Un LED azul indica la ubicacin del interruptor en habitaciones oscuras Instalacin de terminales de tornillo requiere de conexiones de cables para Line (Hot) (Lnea [con corriente]), Load (carga), Neutral (neutro) y Ground (tierra). Se requiere un cable puente para instalaciones de 3 vas 2. A B C D E G H F A. Tierra (Verde/Pelado) B. Carga (Negro) C. Lnea (Negro) D. Puente (Rojo/Otro) E. Neutro (Blanco) F. Interruptor de espacio de aire Elimina la alimentacin elctrica del atenuador de luz. G. Interruptor basculante superior Presione y suelte para ENCENDER el atenuador de luz, presione y mantngalo presionado para aumentar el brillo Presione y suelte para ENCENDER el dispositivo. Presione y mantenga presionado durante 10 segundos para restablecer el dispositivo con wi a las especicaciones de fbrica H. Interruptor basculante inferior Presione y suelte para apagar el interruptor y presione sin soltar para disminuir la intensidad de brillo 3. TOP Cmo cambiar la paleta Este paso es opcional. Antes de comenzar, tal vez necesite cambiar el color de la paleta para que combine con la placa o la decoracin de pared. 1. Inserte un destornillador de hoja plana en una de las ranuras de la parte superior de la paleta y presione suavemente para retirar la paleta. 2. Alinee la nueva paleta con la parte inferior del dispositivo con wi y presione para colocarla en su lugar. 5. Esquema de cableado tpico para una instalacin de 3 vas Lado de la lne (viva) Lado de la carga Tierra Lnea Carga H H C H H C En una aplicacin tpica de 3 vas hay dos interruptores de 3 vas. El interruptor en el lado lnea (vivo) tiene una terminal comn unida a 120VAC. El interruptor en el lado de la carga tiene el comn unido a la carga que los interruptores apagan y encienden. Lado line (lnea) Figura 1 - Interruptor ancho de lnea antes Tierra 4 Lnea H 2 H C 3 1 Figura 2 - Lado line (lnea) despus H 2 Tierra 4 H C 5 2 Lnea 1 3 1. Cable negro/tornillo negro - lnea 2. Cable rojo/tornillo de latn - puente 1 3. Cable negro/tornillo de latn - puente 2 4. Cable de cobre/tornillo verde - tierra 1. Cable negro (lnea) a tuerca para cable 2. Cable rojo (puente 1) a tornillo de latn 3. Cable negro (puente 2) a tuerca cable 4. Cable verde/de cobre - tierra 5. Puente blanco a tuerca para cable/tornillo negro Lado load (carga) Inserte los cables en los oricios, no pase los cables alrededor de los tornillos. No quite los tornillos. Figura 3 - Interruptor del lado Load (carga) Carga Figura 4 - Interruptor del lado load
(carga) despus (wifi) Load 4 H 3 H C 2 1 1. Cable negro / tornillo negro - carga 2. Cable rojo / tornillo de latn - puente 1 3. Cable negro / tornillo de latn - puente 2 4. Cable verde/de cobre - tierra D N U O R G D A O L E N I L R E L E V A R T L A R T U E N Carga Viajero 2 Neutro Tierra Viajero 1 1 3 5 4 2 Cableado del interruptor monofsico Cmo retirar un interruptor existente Antes de comenzar, tal vez necesite cambiar el color de la paleta para que combine con la placa o la decoracin de pared. Contine con la seccin 3. A. Interrumpa el suministro de energa al circuito desde el panel de fusibles o el de cortacircuitos. IMPORTANTE: Antes de continuar, compruebe que se ha INTERRUMPIDO la alimentacin elctrica a la caja del interruptor. B. Quite la placa de la pared. C. Retire los tornillos de montaje del interruptor. D. Saque el interruptor de la caja con cuidado. NO desconecte los cables. Estn marcados hasta cinco terminales de tornillo en el interruptor:
a. TIERRA (GROUND) Verde/Pelado b. CARGA (LOAD) Negro (conectada al dispositivo de iluminacin) c. LINEA (con corriente) (LINE [Hot]) Negro
(conectada al suministro elctrico) d. PUENTE (TRAVELER) Rojo/Otro (solo en instalaciones de 3 vas) e. NEUTRO (NEUTRAL) Blanco Haga corresponder estos terminales de tornillo con los cables conectados al interruptor existente. E. Desconecte los cables del interruptor existente. Tome la precaucin de rotular los cables segn la conexin anterior al terminal. Instalacin Longitud de cable sin aislamiento:
Pele el aislante para el aditamento 16mm (5/8in.). La norma de UL especica que el par de apriete de los tornillos debe ser de 14Kgf-cm (12lbf-in). F. Conecte el cable de cobre verde o pelado de conexin a tierra al terminal tierra (ground). I. Conecte el cable negro que va al dispositivo de iluminacin al terminal marcado carga (load). II. Conecte el cable negro que viene del panel de servicio elctrico (hot) (con corriente) al terminal marcado lnea (line). III. Conecte el cable blanco al terminal neutro
(neutral) (use un cable puente, de ser necesario). Muchas veces, el cable neutro se puede encontrar en la parte trasera de la caja del interruptor, conectado con un empalme de cable. Puede haber varios cables neutros amarrados. Nota: El terminal puente solo se utiliza en instalaciones de 3 vas. IV. Introduzca el interruptor en la caja del interruptor, teniendo cuidado de no comprimir o presionar los cables. G. Asegure bien el interruptor a la caja usando los tornillos que se suministran. H. Coloque la placa de la pared. Reanude el suministro de energa al circuito desde el panel de fusibles o el de cortacircuitos y pruebe el sistema. La luz indicadora azul ubicada debajo de la paleta de ENCENDIDO/
APAGADO debe parpadear rpidamente. Si la luz azul no parpadea, primero asegrese que el interruptor de espacio de aire est en la posicin ENCENDIDO (derecha). Si la luz azul an no parpadea, apague el disyuntor, verique que el suministro al atenuador con wi est desconectado, cambie los cables en los terminales LINE (lnea) y LOAD (carga), y ajuste los tornillos. Monte la placa de pared y reanude el suministro de energa energa al circuito en el panel de fusibles o el de cortacircuitos. Cableado del atenuador de luz de 3 vas IMPORTANTE!
Los interruptores de 3 vas se pueden cablear de diferentes maneras. Estas instrucciones detallan los mtodos ms comunes. Si tiene dicultades con estas instrucciones o con los cables elctricos de su vivienda, contacte a un electricista profesional para obtener ayuda. 1. Interrumpa la alimentacin al panel de fusibles o de cortacircuitos. IMPORTANTE! Antes de continuar, compruebe que se haya APAGADO la alimentacin elctrica al interruptor. 2. Retire la placa del pared del lado de lnea. 3. Retire los tornillos de montaje en el interruptor de lado lnea existente. 4. Saque el interruptor de la caja con cuidado. NO desconecte los cables todava. 5. Identique el cable negro (lnea) conectado al disyuntor, adjunto al tornillo negro. Etiquete el cable lnea. 6. Identique el cable rojo (normalmente) conectado al lado carga, adjunto al otro tornillo de latn. Etiquete puente 1. 7. Identique el cable negro conectado al lado carga, adjunto al tornillo de latn. Etiquete el cable puente 2. Prepare el lado lnea para la nueva conexin de 3 vas 1. Desconecte el cable negro etiquetado lnea del tornillo negro y el otro cable negro etiquetado puente 2 del tornillo de latn. 2. Utilice la tuerca para cable suministrada para conectar los dos cables negros con uno de los cables puente blancos incluidos. 3. Conecte el extremo libre del cable puente blanco al tornillo negro (caliente) del interruptor existente. 4. Vuelva a colocar el interruptor de la caja con cuidado. Asegrese que los cables no estn pinzados o aplastados. Asegure el interruptor utilizando los tornillos de montaje. Instalacin del atenuador de luz wi en el lado LOAD (carga) 1. Retire la placa de pared del lado de carga. 2. Retire el interruptor existente del lado de carga de la caja. NO desconecte los cables todava. 3. Identique el cable negro conectado al lado carga
(lmpara), adjunto al tornillo negro. Etiquete como carga. 4. Identique el cable rojo del lado lnea, adjunto al tornillo de latn. Etiquete el cable puente 1. 5. Identique el cable negro proveniente del lado lnea. Etiquete el cable puente 2. 6. Ubique los cables neutros dentro de la caja del interruptor. Conecte el otro cable puente blanco incluido al conjunto de cables neutros. Etiquete el cable neutro. 7. Desconecte el cable negro etiquetado carga y conctelo al terminal de carga en el atenuador de luz wi. 8. Desconecte el cable rojo etiquetado puente 1 y conctelo al terminal de puente en el atenuador de luz wi. 9. Desconecte el cable negro etiquetado puente 2 y conctelo al terminal de lnea en el atenuador de luz wi. 10. Conecte el extremo libre del cable puente blanco al terminal neutro del atenuador de luz wi. 11. Desconecte el cable verde o de cobre y conctelo al terminal de tierra en el atenuador de luz wi. 12. Vuelva a colocar el atenuador de luz wi en la caja con cuidado. Asegrese que los cables no estn pinzados o aplastados. Asegure utilizando los tornillos de montaje. 13. Restablezca la electricidad en el disyuntor o panel de fusiles. 14. Verique que la luz indicadora azul en el atenuador de luz wi parpadee rpidamente. Si la luz azul no parpadea, primero asegrese que el interruptor de espacio de aire est en la posicin ENCENDIDO (derecha). Si la luz azul an no parpadea, apague el disyuntor, verique que el suministro al atenuador con wi est desconectado, cambie los cables en los terminales LINE (lnea) y LOAD (carga), y ajuste los tornillos. Monte la placa de pared y reanude el suministro de energa energa al circuito en el panel de fusibles o el de cortacircuitos. Atenuador de luz inteligente de pared con wi MTS5406, MTS5407 HECHO EN CHINA GE es una marca comercial de General Electric Company con licencia otorgada a Jasco Products Company LLC, 10 E. Memorial Rd., Oklahoma City, OK 73114. Este producto de Jasco tiene una garanta de por vida limitada. Visite www.byjasco.compara conocer los detalles de la garanta. Preguntas? Comunquese con nuestro Centro de atencin al cliente con sede en EE. UU. al 1-800-654-8483 de 7:00 a. m. a 8:00 p. m. CST (hora central estndar). 4. ORO A B D C E B A C D E Inserte los cables en los oricios, no pase los cables alrededor de los tornillos. No quite los tornillos. Salida al dispositivo de iluminacin
(carga) LOAD CARGA TIERRA PUENTE NEUTRO LINEA Desde el panel del disyuntor H F G