Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B Specifications Datasheet Module supports:
Module Part Number:
Module# ModuleName HTPartNumber remark
#1 NXP5169LIGHT MODULE HTMD004B Role Author Checked by Approved by Date:
<31 July 2018>
Name:
Li Dan Nick Qiao Yin Zhi Lin Classification Confidential Appointment:
Design Engineer PM R&D CTO Version:
<V0.1>
Signature:
Status:
<Draft>
Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B Revision History:
Version Date Author V0.1 V0.2 V0.3
(dd/mm/yyyy) 31/07/2018 22/08/2018 7/9/2018 Li Dan Li Dan Li Dan Status Modifications Draft Draft Draft Doc creation Add 5169 module Add parameter All rights are reserved. The information presented in this document does not form part of any quotation, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights. Page 2 of 14 Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B 1 Introduction 1.1 Scope Module
#
#1 ModuleName HTP/N SOC Standard Supported RFFrequency Band Interfaceto Host Module Size 2.4G(2.4~
2.5GHz) UART 22mm x 15mm(W) x 3mm(H)
(L) NXP5169LIGHT MODULE HTMD004B JN5169 Zigbee3.0 Page 3 of 14 Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B 1.2 Product Features Page 4 of 14 Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B TX output power:11dBm Single-pin antenna interface RSSI monitoring. Page 5 of 14 Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B Page 6 of 14 Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B Ambient Conditions:
Operation Temperature: -10 ~ +120 Storage Temperature: -40 ~ +85 Operation Humidity: 10 ~ 90% RH Storage Humidity: 5 ~ 95% RH Environmental compliance:
RoHS compliant REACH compliant Page 7 of 14 Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B 2 Technical Specifications 2.1 Absolute Maximum Ratings:
Stresses beyond these conditions listed below may cause permanent damage to the module. Parameters Power Supply Voltage at +3V3 Input voltage to IO pins Storage Temperature Conditions Storage Humidity conditions ESD (HBM) Maximum Rating
(-0.3 ~3.63)V
(-0.3 ~3.63)V 40 ~ +85. 5% to 95% (RH) 1000V 2.2 Recommended Operation Conditions Parameters Operating Temperature Conditions Operating Humidity conditions Operation Conditions
(10 ~ +120)
- No performance reduction up 80C ambient Temperature
- No component failure up to 120C ambient Temperature. 10% to 90% (RH) Page 8 of 14 CLASSIFIED: Confidential Jiang Su HuiTong Group Co., Ltd Report No:
2.3 Electrical Specifications Pre-test conditions:
1 Operation Temperature = room temperature 25C, unless otherwise noted. 2 CTQ parameters are marked with *. Parameters Input power Item No. 2.3.1 2.3.2 Power 2.3.3 consumption 2.3.4 ESD Test Conditions Test board standby Active EN61000-3-2/3-3: ESD
- IEC61000/4/2 : 8kV air
- ANATEL 442 : 8kV air discharge Module is mounted into Final product casing at the designed location. Specifications/Requirement Min Typ Max Units 2.8V 3.3V 3.6V V mA mA No functional failures and no parts should suffer damage 2.4 RF Performance 1) TX power is at typical level, measured at antenna feed point. 2) Front End Insertion loss ( including Balun, impedance mis-match+diplexer) 3)Operation Temperature = room temperature 25C, unless otherwise noted. 4)CTQ parameters are marked with *. 2.4.1 Zigbee RF Specifications Item No. Parameters Test Conditions 2.4.2.1 receiver sensitivity 2405 nominal for 1 % PER, as per 802.15.4 Page 9 of 14 Specifications/Requirement Min Typ Max Units
-97 dBm Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B 2.4.2.2 2.4.2.3 2.4.2.4 2.4.2.5 Power 2.4.2.6 2440 nominal for 1 % PER, as per 802.15.4 2480 nominal for 1 % PER, as per 802.15.4 2405 2440 2480
-97
-97 dBm dBm 10.70 dBm 10.03 dBm
-7.62 dBm 2.5 Quality, Environmental and Reliability S/N Electrical Test Requirement 2.5.1 Dry heat Test 2.5.2 2.5.3 Low Temperature storage Temperature Shock 2.5.4 Humidity Load Test 2.5.5 Vibration test TEST CONDITION Requirement Temp. : +70 Test time : 96 hrs Temp. : -25 Test time : 96 hrs Temp. : -20 ~ +85, Duration : 30 min Ramp-up & Ramp-down for 5 min, Cycle : 1,000cycle. 4 days 4 days 35 days Leave samples in 405, 90 ~ 95% RH for 21days, and in standard test condition for 30 minutes 10-55-10Hz / amplitude 0.35mm / sweep rate 1 octave per min. 2.5.6 Cold Test Operational/start up after min 4hrs at -10 2.5.7 Damp heat cyclic 2.5.8 Temperature step stress test Humidity 93%RH, 6h:temp from 25 to 40 , 6hrs temp 40 to 25 , 6hrs at 25 , operational last hour only for 21 days. Operational up to a temperature of 60 for 16 days 16 days Page 10 of 14 21 days 1 day 1 day 21 days Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B 2.5.9 Operation Life(MTBF) Temp. : 60, 90% RH, MTBF 50,000 hrs 10 days 2.6 EMC Compliance and Certifications Region Regulation Standards Requirement EU/RU LATAM:
Fulfill CE with official test report at module level to meet the latest EMC requirement Fulfill approbation requirements, with official test report at Module level 2.7 Environment Compliance RoHS compliant REACH compliant Page 11 of 14 Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B 3 Mechanical Drawing 3.1 Mechanical Outline and dimensions Dimension (TOP View) Dimension (Side View) 3mm Page 12 of 14 CLASSIFIED: Confidential Jiang Su HuiTong Group Co., Ltd Report No:
Dimension (Bottom View) 3.2 Actual Module image Page 13 of 14 Page 13 of 1 Jiang Su HuiTong Group Co., Ltd CLASSIFIED: Confidential Report No: HTMD-004B FCC Statement:
Any Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment . This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. FCC Label Instructions:
The outside o f final products that contains this module device must display a label referring to the enclosed module. Thi s exterior label can use wording such as: "Contains Transmitter Module FCC ID: PUW-HTMD00 4B or Contains FCC ID: PUW-HTMD004B " , Any similar wording that expresses the same meaning may be used. Page 14 of 14