FCC ID: 2AQTC-T60 AI Translator

by: JIANGXI JOYHONG TECHNOLOGY CO.,LTD latest update: 2018-09-06 model: T60

Two grants have been issued under this FCC ID on 09/06/2018 (this is one of two releases in 2018 for this grantee). Public details available include manuals, internal & external photos, and frequency information. some products also feature user submitted or linked warrantee terms, password defaults, troubleshooting guides, drivers, & instructions.
permalink for this FCC identifier
|
|
|   
eg for Slack usage
app s submitted / available
1 2 User Manual Users Manual pdf 289.39 KiB June 09 2018
1 2 Cover Letter(s) pdf June 09 2018
1 2 External Photos pdf June 09 2018
1 2 Cover Letter(s) pdf June 09 2018
1 2 Internal Photos pdf June 09 2018
1 2 Cover Letter(s) pdf June 09 2018
1 2 ID Label/Location Info pdf June 09 2018
1 2 ID Label/Location Info pdf June 09 2018
1 2 Test Report pdf June 09 2018
1 2 Test Setup Photos pdf June 09 2018
1 2 RF Exposure Info pdf June 09 2018
1 2 RF Exposure Info pdf June 09 2018
1 2 RF Exposure Info pdf June 09 2018
1 2 Cover Letter(s) pdf June 09 2018
1 2 External Photos pdf June 09 2018
1 2 Test Report pdf June 09 2018
1 2 Test Report pdf June 09 2018
1 2 User Manual Users Manual pdf 289.39 KiB June 09 2018

frequency equipment class purpose
1 2018-09-06 2412 ~ 2462 DTS - Digital Transmission System Original Equipment
2 2502.5 ~ 2567.5 PCT - PCS Licensed Transmitter worn on body

Application Forms

app s Applicant Information
1 2 Effective 2018-09-06
1 2 Applicant's complete, legal business name JIANGXI JOYHONG TECHNOLOGY CO.,LTD
1 2 FCC Registration Number (FRN) 0027747237
1 2 Physical Address Skyline Photoelectric Industrial Park
1 2 Ji'an City, Jiangxi,, N/A
1 2 China
app s TCB Information
1 2 TCB Application Email Address t******@siemic.com
1 2 TCB Scope A4: UNII devices & low power transmitters using spread spectrum techniques
1 2 B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
app s FCC ID
1 2 Grantee Code 2AQTC
1 2 Equipment Product Code T60
app s Person at the applicant's address to receive grant or for contact
1 2 Name J**** H******
1 2 Title Project Manager
1 2 Telephone Number +86 1********
1 2 Fax Number N/A********
1 2 E-mail p******@joyhong.com
app s Technical Contact
n/a
app s Non Technical Contact
n/a
app s Confidentiality (long or short term)
1 2 Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:Yes
1 2 Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:No
if no date is supplied, the release date will be set to 45 calendar days past the date of grant.
app s Cognitive Radio & Software Defined Radio, Class, etc
1 2 Is this application for software defined/cognitive radio authorization?No
1 2 Equipment ClassDTS - Digital Transmission System
1 2 PCT - PCS Licensed Transmitter worn on body
1 2 Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant)AI Translator
1 2 Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application?No
1 2 Modular Equipment TypeDoes not apply
1 2 Purpose / Application is forOriginal Equipment
1 2 Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization?Yes
1 2 Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?No
1 2 Grant CommentsPower listed is the maximum conducted output power. The device has 20MHz and 40MHz bandwidth. For body worn operation, this device has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the device a minimum of 0 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported SAR for Body-worn accessory, Hotspot and simultaneous transmission are: 0.33W/kg, 0.33W/kg,1.56W/kg.
1 2 Output power listed is ERP for Part 22 and EIRP for Part 24, 27. For body worn operation, this device has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the device a minimum of 0 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported SAR for Body-worn accessory, Hotspot and simultaneous transmission are: 1.24W/kg, 1.24W/kg, 1.56W/kg
1 2 Is there an equipment authorization waiver associated with this application?No
1 2 If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?No
app s Test Firm Name and Contact Information
1 2 Firm Name Shenzhen Toby Technology Co., Ltd.
1 2 Name R******** L******
1 2 Telephone Number ---********
1 2 E-mail t******@tongbiao.com
Equipment Specifications
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
1 1 15C 2412.00000000 2462.00000000 0.0530000
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
2 1 22H 824.2 848.8 1.247 0.025 ppm 323KG7W
2 2 24E 1850.2 1909.8 0.728 0.032 ppm 318KG7W
2 3 22H 826.4 846.6 0.133 0.024 ppm 4M90F9W
2 4 24E 1852.4 1907.6 0.133 0.01 ppm 4M90F9W
2 5 27 2502.5 2567.5 0.157 0.0292 ppm 15M0G7D
2 6 27 2502.5 2567.5 0.136 0.0245 ppm 15M1W7D
2 7 27 2502.5 2567.5 0.119 0.0284 ppm 20M8G7D
2 8 27 2502.5 2567.5 0.122 0.0304 ppm 20M9W7D

 