all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 1.08 MiB | ||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | Cover Letter(s) | |||||||
1 | ID Label/Location Info | |||||||
1 | ID Label/Location Info | |||||||
1 | RF Exposure Info | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos | |||||||
1 | Cover Letter(s) |
1 | User Manual | Users Manual | 1.08 MiB |
USR-IO808-EWR User Manual Technical Support: h.usriot.com USR-IO808-EWR User Manual File Version: V1.0.4.01 Jinan USR IOT Technology Limited www.usriot.com 1 USR-IO808-EWR User Manual Technical Support: h.usriot.com Contents USR-IO808-EWR User Manual ........................................................................................................................... 1 Features .................................................................................................................................................................... 3 1. Get Start ................................................................................................................................................................ 4 1.1. Product introduction ............................................................................................................................... 4 1.2. Basic parameters .................................................................................................................................... 4 1.3. Hardware .................................................................................................................................................. 4 1.3.1. Interface ........................................................................................................................................ 5 1.3.2. LED .................................................................................................................................................. 5 1.3.3. Dimension ..................................................................................................................................... 5 1.4. Test............................................................................................................................................................. 6 1.4.1. Control by serial ........................................................................................................................... 7 1.4.2. Web Server .................................................................................................................................... 9 1.4.3. Control by USR Cloud ................................................................................................................... 9 2. Product function ................................................................................................................................................ 11 2.1. DI input .................................................................................................................................................... 11 2.1.1. Electrical level detection ............................................................................................................. 11 2.1.2. Buttons detection ........................................................................................................................ 11 2.1.3. Pulse counting ............................................................................................................................ 12 2.2. DO output ................................................................................................................................................ 12 2.3. Work mode ............................................................................................................................................. 12 2.3.1. Master mode................................................................................................................................ 12 2.3.2. Slave mode ................................................................................................................................... 14 2.4. Upgrade firmware ................................................................................................................................. 15 2.5. Ethernet interface and WiFi ............................................................................................................... 15 2.5.1. Ethernet interface ..................................................................................................................... 15 2.5.2. WiFi .............................................................................................................................................. 15 2.6. Serial port ............................................................................................................................................... 16 2.6.1. Basic parameters ....................................................................................................................... 16 2.6.2. Configuration method ............................................................................................................... 16 2.7. Features ................................................................................................................................................... 16 2.7.1. Relay output status hold ............................................................................................................ 16 2.7.2. Conditional control .................................................................................................................... 17 2.7.3. Connect to remote server ......................................................................................................... 18 2.7.4. Reset to default by hardware ................................................................................................... 18 3. Modbus ............................................................................................................................................................... 19 3.1. Modbus frame ........................................................................................................................................ 20 3.2. Register distribution ............................................................................................................................ 20 4. Contact Us ........................................................................................................................................................... 23 5. Disclaimer .......................................................................................................................................................... 24 6. Update History .................................................................................................................................................. 24 Jinan USR IOT Technology Limited www.usriot.com 2 USR-IO808-EWR User Manual Technical Support: h.usriot.com Features Support 8-way Relay output. Support 8-way input, default is dry contact. Support 8 conditional control command. Support Web Server to configure IO808-EWR. Support various function code: 0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x0F, 0x10. Support socket to connect to remote server and TCP Client. Support two work modes: Master mode and Slave mode. Master mode supports connecting to multiple Modbus RTU devices by RS485 cascading connection. Adopt Modbus RTU protocol data processing. Support Modbus TCP/RTU protocol adaptation. Support WAN/LAN interface and LAN interface network. Support AP and STA two WiFi modes. Support connecting to USR Cloud. Support FTP remote upgrade. Support upgrading by RS485. Support hardware watchdog. Support various LED to indicate work status. Support power supply over-current, over-voltage, anti-reverse connection protection. Jinan USR IOT Technology Limited www.usriot.com 3 USR-IO808-EWR User Manual Technical Support: h.usriot.com 1. Get Start If user has any question, please submit it back to customer center: h.usriot.com. 1.1. Product introduction USR-IO808-EWR is network IO product which supports 8-way input/output and Modbus RTU/TCP protocol. Take Remote control as core function and have high usability. User can easily and quickly integrate USR-IO808-EWR into own system to realize remote, LAN and local control which based on Ethernet, WiFi and RS485. 1.2. Basic parameters Parameter Value Ethernet interface Wired WAN/LAN interface 10/100M WAN/LAN interface WiFi parameters Hardware parameters Wired LAN interface Standard Antenna Range Data interface 10/100M LAN interface Support 802.11b/g/n 2.4G WiFi antenna 100 meters in open area Serial port: Support RS485. Baud rate: 300bps~230400bps Working voltage DC: 12V~36V DI input Dry contact input, just needing to short-circuit DI DO output Working temperature Storage temperature Working humidity Storage humidity Dimension Work mode Software parameters Configuration command and COM AC 220V 10A DC 28V 10A
-20 ~ +70
-40 ~ +85 5%~95%
1%~95%
200*122*29mm Master mode, slave mode Modbus RTU Network protocol Application software Modbus TCP, Modbus RTU Support configuration software Software function DNS EMC level Data transmission mode ESD Surge Group pulse Support Support TCP Client IEC61000-4-2, Level 4 IEC61000-4-5, Level 3 IEC61000-4-4, Level 3 Figure 1 Basic parameters 1.3. Hardware Jinan USR IOT Technology Limited www.usriot.com 4 USR-IO808-EWR User Manual Technical Support: h.usriot.com 1.3.1. Interface Figure 2 Product interface diagram Antenna: WiFi antenna RS485: RS485 interface DO: DO1~DO8 are 8-way Relay output DI: 8-way input, default is dry contact WAN/LAN: Device WAN/LAN interface and can switch between WAN/LAN LAN: Device LAN interface DC: 12-36V. DC 12~36V power supply. Low power supply will cause IO808-EWR cant start. 1.3.2. LED LED POWER WORK Function Status Indicate power status Light after powering module Indicate system running status Blink every 1 second after product system running;
Blink every 0.2 second during upgrading firmware process. NET Indicate network connection status Light after connecting to remote server WAN/LAN Indicate WAN/LAN interface status Light after connecting to network. Blink if has data interaction. LAN Indicate LAN interface status Light after connecting to network. Blink if has data Figure 3 LED interaction. 1.3.3. Dimension Jinan USR IOT Technology Limited www.usriot.com 5 USR-IO808-EWR User Manual Technical Support: h.usriot.com Figure 4 Dimension diagram Fixed installation diagram as follow:
Figure 5 Fixed installation diagram 1.4. Test Jinan USR IOT Technology Limited www.usriot.com 6 USR-IO808-EWR User Manual Technical Support: h.usriot.com Connect PC to USR-IO808-EWR by USB -> RS485 cable. Connect IO808-EWRs WAN/LAN interface to router. Connect IO808-EWRs LAN interface to PC. Power the IO808-EWR. After powering on, please wait about 15 seconds and users PC can access internet. Note: If user uses USR-IO808-EWR firstly and cant access internet with correct connection, it maybe the following reason: LAN interface network segment is same as USR-IO808-EWRs LAN interface network segment. The solution is: Enter USR-IO808-EWRs Web Server(Default IP address is 192.168.10.1) and modify LAN interface IP address to other network segment, then restart device. 1.4.1. Control by serial Power IO808-EWR and connect IO808-EWRs RS485 interface to PC. Run setup software USR-IO V1.0.28.exe and choose IO808-EWR. Choose correct COM and configure correct serial port parameters as follow(Default settings is 9600, None, 8, 1):
Figure 6 Open serial After opening serial port, click Search to search IO808-EWR and click to stop searching after finding IO808-EWR. Then choose IO808-EWR as follow:
Jinan USR IOT Technology Limited www.usriot.com 7 USR-IO808-EWR User Manual Technical Support: h.usriot.com Then user can control devices. Figure 7 Search IO808-EWR User can also click Switch To Param Set on above figure to enter IO808-EWR configuration page. Figure 8 Control devices Jinan USR IOT Technology Limited www.usriot.com 8 USR-IO808-EWR User Manual Technical Support: h.usriot.com Figure 9 Configuration page 1.4.2. Web Server The initial parameter of USR-IO808-EWR to enter Web Server as follow:
Work mode Username Password LAN interface IP address Network data transparent transmission admin admin 192.168.10.1 Figure 10 Initial parameter of USR-IO808-EWR to enter Web Server Type 192.168.10.1 into browser address bar and log in with username and password(Both are admin). Then user can query and configure parameters of USR-IO808-EWR by Web Server. 1.4.3. Control by USR Cloud User can type http://console.usr.cn/ into browser address bar to enter USR Cloud web page and login with username and password. Then user can add device as follow:
Jinan USR IOT Technology Limited www.usriot.com 9 USR-IO808-EWR User Manual Technical Support: h.usriot.com Figure 11 Add IO808-EWR Choose Networking I/O controller as Device type, write IMEI and SN on IO808-EWRs label and click Save to add IO808-EWR. After adding IO808-EWR, power IO808-EWR and wait LED NET light which means IO808-EWR connects to USR Cloud. Then user can remotely look over, record and control IO808-EWR status in real time through USR Cloud(Monitor->Data list). Jinan USR IOT Technology Limited www.usriot.com 10 USR-IO808-EWR User Manual Technical Support: h.usriot.com 2. Product function USR-IO808-EWR functional diagram as follow:
Figure 12 Functional diagram 2.1. DI input 2.1.1. Electrical level detection Register address range: 32~39(0x0020~0x0027) Supported function code: 02(Read discrete input), 03(Read holding register) Connection: Default is dry contact input. Short-circuit DI and COM will change input status. If user needs wet contact input can contact to our sales personnel Electrical level detection: Default status is 0, after short-circuiting DI and COM, status will be 1. Detection method: 02 function code of Modbus protocol. Example:
Detect input of the first way, send: 11 02 00 20 00 01 BA 90 Short-circuiting will return: 11 02 01 01 64 88 No short-circuiting will return: 11 02 01 00 A5 48 2.1.2. Buttons detection Register address range: 48~55(0x0030~0x0037) Supported function code: 03(Read holding register), 04(Read input register) Connection: Default is dry contact input. Short-circuit DI and COM will change input status. If user needs wet contact input can contact to our sales personnel Electrical level detection: Default status is 0000, after short-circuiting DI and COM and then releasing, status will be FF00. Detection method: Read button register value by 03 function code of Modbus protocol. After reading once button register, status will recover to 0000; after executing conditional control, status will recover to 0000. too. Example:
Detect the first way button, send: 11 03 00 30 00 01 86 95 Jinan USR IOT Technology Limited www.usriot.com 11 Serial port device(Should support Modbus RTU protocl)NetworkserverSlave modeExecute Modbus protocol RS485Master modeRTU check Data transparent transmissionRTU check Communication moduleModbus TCP/RTU protocol conversionInputOutputSwitch/Button inputRelay output USR-IO808-EWR User Manual Technical Support: h.usriot.com No button will return: 11 03 02 00 00 79 87 Have button will return: 11 03 02 FF 00 38 77 2.1.3. Pulse counting Register address range: 64~71(0x0040~0x0047) Supported function code: 03(Read holding register), 04(Read input register) Connection: Default is dry contact input. Short-circuit DI and COM will change input status. If user needs wet contact input can contact to our sales personnel Pulse counting: Default status is 0, short-circuit DI and COM and then release will count 1. Detection method:
Read pulse counting register value by 03 function code of Modbus protocol. Maximum value of pulse counting is 65535 and it will restart counting after exceeding 65535. Cant reset count to 0 and restart product wont save count. Note: Pulse counting wont filter input waveform and all pulse in the range of detection will be recorded. So input waveform should keep stable to ensure accurate count. Example:
Detect count of the first way, send: 11 03 00 40 00 01 87 4E Return: 11 03 02 00 00 79 87 2.2. DO output Register address range: 00~07(0x0000~0x0007) Supported function code: 01(Read coil), 05(Write single coil), 0F(Write multiple coil) Connection: DO output is Relay passive output. Dont power the coil, Relay COM and NC will close, COM and NO will open. After powering, the contrary is the case. Take the first way Relay control as example:
Query: 11 01 00 00 00 04 3F 59 Control to close: 11 05 00 00 FF 00 8E AA Control to disconnect: 11 05 00 00 00 00 CF 5A 2.3. Work mode Default work mode of USR-IO808-EWR is slave mode. IO808-EWR will be slave both on network side and RS485 side and IO808-EWR will discard data if IO808-EWR receives data not for IO808-EWR local address. 2.3.1. Master mode Master mode data flow diagram and connecting to network diagram as follows:
Jinan USR IOT Technology Limited www.usriot.com 12 USR-IO808-EWR User Manual Technical Support: h.usriot.com Figure 13 Master mode data flow Figure 14 Connecting to network in Master mode In master mode, server can communicate to network IO product IO808-EWR and Modbus devices which connect to IO808-EWRs RS485 interface. RS485 side can also transmit data to IO808-EWR directly. User can configure IO808-EWR to Master mode by setup software as follow(Configure RS485 mode to 1.DTU):
Figure 15 Configure IO808-EWR to Master mode Jinan USR IOT Technology Limited www.usriot.com 13 USR-IO808-EWR User Manual Technical Support: h.usriot.com 2.3.2. Slave mode Slave mode data flow diagram and connecting to network diagram as follows:
Figure 16 Slave mode data flow Figure 17 Connecting to network in Slave mode In this mode, IO808-EWR can communicate to network server and Modbus devices on RS485 network. But network server cant communicate to Modbus devices on RS485 network. User can configure IO808-EWR to salve mode by setup software as follow(Configure RS485 mode to 2.RTUSLAVE):
Figure 18 Configure IO808-EWR to Slave mode Jinan USR IOT Technology Limited www.usriot.com 14 USR-IO808-EWR User Manual Technical Support: h.usriot.com 2.4. Upgrade firmware User can refer to FAQ <<Upgrading firmware method of USR-IO808-EWR_V1.0.0>>. 2.5. Ethernet interface and WiFi 2.5.1. Ethernet interface USR-IO808-EWR has two Ethernet interface: WAN/LAN interface and LAN interface. WAN/LAN interface supports switching between WAN/LAN by modifying value of corresponding register. User can configure by setup software as follow:
Figure 19 WAN/LAN switch 2.5.2. WiFi USR-IO808-EWR supports WiFi function and AP/STA two WiFi modes, AP mode:
1. Set WiFi mode to 1(AP mode) and APSSID/APs password, then restart device. 2. After restarting successfully, use PC or mobile to search IO808-EWR and connect. STA mode:
1. Set WiFi mode to 2(STA mode) and SSID/password of the target AP which user wants to connect IO808-EWR to, then restart device. 2. After restarting successfully, IO808-EWR will connect to target AP automatically. Figure 20 WiFi mode Jinan USR IOT Technology Limited www.usriot.com 15 USR-IO808-EWR User Manual Technical Support: h.usriot.com 2.6. Serial port 2.6.1. Basic parameters Parameter Baud rate Data bits Stop bits Parity Range 300~230400 7, 8 1, 2 NONE, EVEN, ODD 2.6.2. Configuration method Figure 21 Serial port basic parameters Serial port parameters occupy two registers. Length of protocol is 4 bytes and specific protocol content as follow(All examples are in HEX format):
Parameter bit 1 Refer to Serial port parameter Name Number of bytes Description Baud rate 3 Three bytes represent a baud rate value and high-order in the former Example 1(115200, None, 8, 1) Example 2(9600, None, 8, 1) 01 C2 00 00 25 80 Bit number Representation Value Figure 22 Serial port parameters protocol 1:0 Data bits 2 5:4:3 Stop bits Parity 7:6 No definition 10 11 0 1 000 001 011 00 bit 03 03 Description 7 bits data bits 8 bits data bits 1 bit stop bits 2 bits stop bits None ODD EVEN Please write 0 Figure 23 Serial port parameter bit 2.7. Features 2.7.1. Relay output status hold User can configure whether hold Relay output status: After restarting IO808-EWR or powering on IO808-EWR again, hold the Relay output status or reset to disconnect status. Register address: 182(0x00B6) Parameter values: 1(0x0001): All Relays hold status after restarting or powering off. 2(0x0002): All relays hold status after restarting and dont hold status after powering off. 3(0x0003): All relays dont hold status after restarting or powering off. Jinan USR IOT Technology Limited www.usriot.com 16 USR-IO808-EWR User Manual Technical Support: h.usriot.com Supported function code: 0x03, 0x04, 0x06, 0x10 Configuration will take effect after restarting. 2.7.2. Conditional control Conditional control function supports user configuring the conditions to trigger IO changes. It can make using IO808-EWR more flexibly and extend application scenario. User only needs to modify conditional control function register parameters according to the instructions , it will realize corresponding function. Conditional control function has 32 registers and 8 conditional control commands(Every command occupies 4 registers). Registers distribution as follow:
Storage content Input register Output register Output action Condition Threshold Length Address 1 byte Range:
16~109 1 byte 1 byte 1 byte 2 bytes Range: 1~16 1, 2, 255 1: Disconnect 2: Close 3: Reversal Compared register values/The first two bytes of time-stamp Figure 24 Conditional control function register Reserved 2 bytes two of Reserved/
Last bytes time-stam p Output action(Relay output) 1: Disconnect 2: Close 3: Reversal Condition 1: Forward direction output follow 2: Backward direction output follow 255: Button action Control mode Switching value control: DI input control DO output directly Semaphore control: DI button semaphore control DO. Press button once, DO act once(Execute action in rising edge of releasing button). Detailed explanation:
1. Forward direction output follow Enable forward direction output follow: Set condition register to 1, input register is corresponding to one way register address of 8-way input and output register is corresponding to one way register address of 8-way output. For example, if configure as 0x20 0x00 0x01 0x01 0x00 0x00 0x00 0x00, it represents status of DO1 will follow status of DI1 which means DO1 will close if DI1 close and DO1 will disconnect if DI1 disconnect. 2. Backward direction output follow Enable backward direction output follow: Set condition register to 2, input register is corresponding to one way register address of 8-way input and output register is corresponding to one way register address of 8-way output. Jinan USR IOT Technology Limited www.usriot.com 17 USR-IO808-EWR User Manual Technical Support: h.usriot.com For example, if configure as 0x20 0x00 0x01 0x02 0x00 0x00 0x00 0x00, it represents status of DO1 will be opposite as status of DI1 which means DO1 will close if DI1 disconnect and DO1 will disconnect if DI1 close. 3. Button control Enable button control: Set condition register to 255, input register is DI button register and output register is DO output register. Action can be 1(disconnect ), 2(close), 3(reversal ), threshold register and reserved register cant work. For example, if configure as 0x30 0x00 0x03 0xFF 0x00 0x00 0x00 0x00, it represents detecting DI1 button once will reverse status of DO1 once. Note:
Input register is 0 means close this conditional control and execute button action once will clear button register. If multiple conditions will lead to paradoxical result, program will execute two results quickly. If forward direction output follow and backward direction output follow lead to paradoxical result, disconnecting and closing will revolve. 2.7.3. Connect to remote server User can modify related register parameters of remote server to realize IO808-EWR connecting to remote server. Procedure as follow:
1. Power the IO808-EWR and connect IO808-EWRs RS485 interface to PC. Run setup software(User can refer to 1.4.1.Control by serial), modify remote server address and remote port as follow:
Figure 25 Configure remote server parameters 2. Restart IO808-EWR to make configuration take effect. 3. Login remote server and open the port. 4. Wait IO808-EWR LED NET light which means IO808-EWR connect to remote server successfully, Then user can transmit Modbus TCP/RTU command from server side to control IO808-EWR and receive response from IO808-EWR. 2.7.4. Reset to default by hardware Jinan USR IOT Technology Limited www.usriot.com 18 USR-IO808-EWR User Manual Technical Support: h.usriot.com User can reset to default settings by pressing Reload button. After powering on, press Reload button 3 seconds to 15 seconds, then release it, IO808-EWR will reset to default settings. Less than 3 seconds or more than 15 seconds will be considered as misoperation and dont handle it. 3. Modbus Jinan USR IOT Technology Limited www.usriot.com 19 USR-IO808-EWR User Manual Technical Support: h.usriot.com 3.1. Modbus frame Modbus RTU:
Figure 26 Modbus RTU frame USR-IO808-EWR data format conform to general Modbus frame format. IO808-EWR can analyse Modbus RTU protocol and execute related operations. Modbus TCP:
Figure 27 Modbus TCP frame USR-IO808-EWR can analyse received network Modbus TCP protocol data and transfer to Modbus RTU protocol to do data processing. IO808-EWR can also be used in Master mode and transfer Modbus RTU protocol to Modbus TCP protocol and transmit to server. 3.2. Register distribution USR-IO808-EWR register instructions:
1. Register base address is 0x0000. 2. In following register distribution table, MCU parameters and communication module parameters must operate together. 3. Setup software USR-IO adopts UTF-8 coded format. 4. Register store HEX format data. Register address Register content Parameter description Applicable function code 0x0000~0x0007 Switch value output 0xFF00 means ON, 0x0000 0x01, 0x05, 0x0F Device I/O 0x0020~0x0027 Switch value input 1 means ON, 0 means OFF 0x02 means OFF;
1 means ON, 0 means OFF Jinan USR IOT Technology Limited www.usriot.com 20 USR-IO808-EWR User Manual Technical Support: h.usriot.com 0x0030~0x0037 Button input Button detection. Reset to 0 0x03, 0x04 0x0040~0x0047 Pulse counting after reading once Count range: 0~65535. Reset to 0 after reaching maximum MCU parameter 0x03, 0x04 0x0068~0x0069 Time-stamp Current time-stamp 0x03, 0x04 0x006A~0x006C Year, month, day, hour, The format of year, month, day, 0x03, 0x04, 0x10 minute, second hour, minute, second is Bcd code. Such as
[0x18,0x01,0x01,0x08,0x24,0x 56] represents 2018-1-1 8:24:56 0x006D Week 0x0001-0x0007 represents 0x03, 0x04 Monday to Sunday 0x008E~0x0091 Conditional control command 1 0x0092~0x0095 Conditional control command 2 0x0096~0x0099 Conditional control command 3 0x009A~0x009D Conditional control 0x009E~0x00A1 Conditional control control command 4 Refer to 2.7.2. Conditional 0x03, 0x04, 0x10 command 5 0x00A2~0x00A5 Conditional control command 6 0x00A6~0x00A9 Conditional control command 7 0x00AA~0x00AD Conditional control command 8 0x00AE~0x00AF RS485 interface Refer to 2.6.2. Configuration 0x03, 0x04, 0x10 0x00B0 RS485 mode method Master mode(0x0001) Slave mode(0x0002) 0x03, 0x04, 0x06, 0x10 0x00B1 Modbus address Slave 0x03, 0x04, 0x06, 0x10 address(0x0001~0x00FD) 0x00B2 Work mode Modbus mode(0x0001) 0x03, 0x04, 0x06, 0x10 Firmware upgrade(0x0002) 0x00B3 Global parameters Default(0x0000), 0x03, 0x04, 0x06, 0x10 configuration restart(0x0001), reset to user default settings(0x0002),reset to USR default settings(0x5555), save current Jinan USR IOT Technology Limited www.usriot.com 21 USR-IO808-EWR User Manual Technical Support: h.usriot.com settings as user default settings(0xAAAA) 0x00B4 MCU software version For example, 0x0112 means 0x03, 0x04 version V1.1.2 0x00B5 MCU hardware version For example, 0x0110 means 0x03, 0x04 version V1.1 0x00B6 Relay status after All relays hold status after 0x03, 0x04, 0x06, 0x10 restarting restarting or powering off(0x0001);
All relays hold status after restarting and dont hold status after powering off(0x0002) All relays dont hold status after restarting or powering off(0x0003) Communication module parameters 0x1021 WiFi mode AP(1)/STA(2) 0x03, 0x04, 0x06, 0x10 0x1022~0x1031 AP mode SSID Character string format 0x1032~0x1041 AP mode password Character string format 0x03, 0x04, 0x10 0x03, 0x04, 0x10 0x1042 0x1043 WAN/LAN switch WAN(1)/LAN(2) 0x03, 0x04, 0x06, 0x10 Remote connection USR Cloud(1)/MAC(2)/User 0x03, 0x04, 0x06, 0x10 identity packet editable(3)/Disable(4) 0x1044~0x1045 LAN interface IP 0xC0A80007 represents 0x03, 0x04, 0x10 192.168.0.7 0x104A WAN interface IP mode DHCP(1)/Static IP(2) 0x03, 0x04, 0x06, 0x10 0x104B~0x104C WAN interface IP 0xC0A80007 represents 0x03, 0x04, 0x10 192.168.0.7 0x104D~0x104E WAN interface mask 0xC0A80007 represents 0x03, 0x04, 0x10 192.168.0.7 0x104F~0x1050 WAN interface 0xC0A80007 represents 0x03, 0x04, 0x10 0x1051~0x1052 gateway DNS1 192.168.0.7 0xC0A80007 represents 0x03, 0x04, 0x10 192.168.0.7 0x1055~0x1074 TCP Client remote Remote server address 0x03, 0x04, 0x10 server address 0x1075 TCP Client remote Remote server port 0x03, 0x04, 0x06, 0x10 port 0x1076 TCP Server/UDP LAN listening port 0x03, 0x04, 0x06, 0x10 Server listening port 0x1078~0x107F 0x1080~0x1087 Username Password Character string format Character string format 0x1088~0x1097 Device name Character string format 0x03, 0x04, 0x10 0x03, 0x04, 0x10 0x03, 0x04, 0x10 0x1098 Device software For example, 0x0112 means 0x03, 0x04 Jinan USR IOT Technology Limited www.usriot.com 22 USR-IO808-EWR User Manual Technical Support: h.usriot.com version version V1.1.2 0x1099 Device hardware For example, 0x0110 means 0x03, 0x04 version version V1.1 0x109A~0x10A9 Target APs SSID in Character string format 0x03, 0x04, 0x10 STA mode 0x10AA~0x10B9 Target APs password Character string format 0x03, 0x04, 0x10 in STA mode 0x10BA~0x10CD User editable identity Character string format 0x03, 0x04, 0x10 0x10CE packet Identity packet sending method Send identity packet after 0x03, 0x04, 0x06, 0x10 establishing connection(1)/Send before every data package(2)/Both way(3) Figure 28 Register distribution 4. Contact Us Jinan USR IOT Technology Limited www.usriot.com 23 USR-IO808-EWR User Manual Technical Support: h.usriot.com Company: Jinan USR IOT Technology Limited Address: Floor 11, Building 1, No. 1166 Xinluo Street, Gaoxin District, Jinan, Shandong, 250101, China Web: www.usriot.com Support: h.usriot.com Email: sales@usr.cn Tel: 86-531-88826739/86-531-55507297 5. Disclaimer This document provides the information of USR-IO808-EWR products, it hasnt been granted any intellectual property license by forbidding speak or other ways either explicitly or implicitly. Except the duty declared in sales terms and conditions, we dont take any other responsibilities. We dont warrant the products sales and use explicitly or implicitly, including particular purpose merchant-ability and marketability, the tort liability of any other patent right, copyright, intellectual property right. We may modify specification and description at any time without prior notice. 6. Update History 2018-05-29 V1.0.4.01 established based on Chinese version V1.0.4. Jinan USR IOT Technology Limited www.usriot.com 24 FCC STATEMENT :
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
receiver is connected. FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Reorient or relocate the receiving an Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the Consult the dealer or an experienced radio/TV technician for help. tenna.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2018-12-19 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2018-12-19
|
||||
1 | Applicant's complete, legal business name |
Jinan USR IOT Technology Limited
|
||||
1 | FCC Registration Number (FRN) |
0027909266
|
||||
1 | Physical Address |
Floor 2, Wuzhou Scientific Research Building
|
||||
1 |
Jinan, Shandong, N/A 250101
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@siemic.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2ARF7
|
||||
1 | Equipment Product Code |
IO808
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
G**** X****
|
||||
1 | Title |
General Manager
|
||||
1 | Telephone Number |
0531-********
|
||||
1 | Fax Number |
0531-********
|
||||
1 |
g******@usr.cn
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | 8DI8DO Network IO with ETH/WIFI | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen Anbotek Compliance Laboratory Limited
|
||||
1 | Name |
J****** Z********
|
||||
1 | Telephone Number |
86-75********
|
||||
1 | Fax Number |
86-75********
|
||||
1 |
j******@anbotek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2412.00000000 | 2462.00000000 | 0.0607000 |