SERVO-DRIVE for AVENTOS Installation leaflet Original AVENTOS HF AVENTOS HS AVENTOS HL Table of contents Validity and target group 2.1 Principle 2.2 Safety information 2.3 Intended use 2.4 Structural changes and spare parts 2.5 Children 2.6 Wall cabinet care and cleaning 1 About these instructions 2 Safety 3 Description 4 Problems 5 Technical data 6 Spare parts 7 Disposal 5.1 Power supply 5.2 Drive unit 5.3 Blum switch 2 2 3 3 3 4 4 4 5 6 10 11 11 11 11 11 11 1 About these instructions Thank you for your purchase. SERVO-DRIVE for AVENTOS from Julius Blum GmbH is a high-quality product that simplifies everyday kitchen tasks. To better enjoy the comfort and safety of SERVO-DRIVE for AVENTOS, please note the following:
Carefully read the instruction leaflet before use. Please retain the instruction leaflet for the service life of SERVO-DRIVE for AVENTOS. Please pass on this instruction leaflet to each subsequent owner or user of SERVO-DRIVE for AVENTOS. DANGER WARNING CAUTION Danger:
The DANGER sign indicates important safety information that must be followed. Warning:
The WARNING sign indicates important warning information that must be followed. Comment:
The CAUTION sign indicates information that if not followed may lead to the pre-
mature wear of SERVO-DRIVE for AVENTOS. NOTICE Note:
The NOTE sign indicates information that should be followed. 2 Validity and target group This instruction leaflet is intended for all users of lift systems in furniture equipped with SERVO-DRIVE for AVENTOS. Installation, set up, initial operation, maintenance and removal may only be carried out by qualified personnel according to the separate installation instructions. 2 Safety 2.1 Principle SERVO-DRIVE for AVENTOS complies with current safety standards. Nevertheless, there are certain risk factors if the information in this instruction leaflet is not followed. Please be aware that Julius Blum GmbH is not responsible for incidental or consequential damages that may arise due to non-compliance with this instruction leaflet. 2.2 Safety information The mains plug and the Blum transformer must be easily accessible. Neither the Blum transformer nor any cabling should come into contact with moving parts. This device should not be used by persons (including children) with limited physical, sensory or mental abilities, or those with a lack of experience and/
or knowledge. Unless they are supervised by a person responsible for their safety or they receive instruction on how to operate the device. Danger of injury in the area of the lever. Touching the area around the lever during the opening and closing motion can cause injury. Do not touch the area around the lever during the opening and closing motion. WARNING 3 2.3 Intended use SERVO-DRIVE for AVENTOS supports the opening and closing of lift systems in furniture and may only be used under the following conditions:
In dry, enclosed rooms In combination with AVENTOS lift systems from Julius Blum GmbH within permitted technical specifications In combination with a Blum transformer Technical data specifications can be found in the Blum sales documentation. For more information, please see your distributor. Julius Blum GmbH is not liable for any other use. 2.4 Structural changes and replacement parts Structural changes and spare parts not approved by the manufacturer affect the safety and functionality of SERVO-DRIVE for AVENTOS and are, therefore, not allowed. Only use original spare parts from Julius Blum GmbH. Blum components are the only devices that should be connected to the Blum transformer. Only qualified technicians may install/replace Blum components, modify the position of the Blum transformer or modify any cabling. 2.5 Children Opening and closing lift systems may pose a risk of injury to children!
Persons, especially children, who are sitting or standing on work surfaces may be pushed from work surfaces or injured when opening and closing a lift system. Children should be properly supervised when in the room so that they do not play with the device. To ensure that SERVO-DRIVE for AVENTOS is not triggered unintentionally, the outlet should be switched off or unplugged. Choke danger to children when playing with the Blum switch. Children could choke on the Blum switch battery. Make sure that children do not open the Blum switch as they could choke on parts or the battery from the Blum switch. To ensure that lift systems cannot be activated unintentionally, we recom-
mend connecting the Blum transformer to a switched outlet. For more infor-
mation, please consult an electrician. DANGER DANGER NOTICE 4 2.6 Wall cabinet care and cleaning Danger of electric shock There is a danger of electric shock if fluids penetrate the Blum transformer
(page 6, item 3). Make sure that no water or aggressive cleaning material comes in contact with the drive unit, Blum transformer or Blum switch while cleaning the wall cabinet. Switch off the power to the Blum transformer and/or unplug the unit before cleaning the drive unit. Never open a Blum transformer. Any cabling damage should be immediately corrected by a qualified specialist. DANGER Damage to the drive unit or Blum switch. Never take apart a drive unit or Blum switch. Penetrating moisture and aggressive cleaning materials can damage the electron-
ics of the drive unit, Blum transformer and Blum switch. The drive unit, Blum transformer and Blum switch should only be cleaned with a moist cloth. The Blum transformer can be damaged if covered by towels or other items due to overheating. Do not cover the Blum transformer with towels or other items. There is a danger of injury if the lever springs upward. There is a danger of injury from the lever springing upwards due to improper removal of the front including fittings. Never remove the front for cleaning. Front removal may only be carried out by qualified personnel according to the separate installation instructions. WARNING 5 3 Description 3 1 2 7 2 1 3 2 1 3 7 5 4 7 5 6 4 7 5 6 4 6 AVENTOS HF AVENTOS HS AVENTOS HL Lift mechanism, drive unit with LED display and cover cap Lever Blum transformer with LED display Blum switch with battery display Blum distance bumper 1 2 3 4 5 6 Cabinet 7 Front / Lift system Function SERVO-DRIVE for AVENTOS supports the opening and closing of lift systems in furniture. Electrical motion support system The Blum switch (page 6, item 4) triggers the automatic opening and closing ac-
tion of SERVO-DRIVE for AVENTOS. Manual use Press on the front The lift system opens automatically Press on the Blum switch The lift system closes automatically The lift system can be opened or closed manually without restrictions, due to the integrated free movement, without damaging SERVO-DRIVE for AVENTOS. Manual opening of the lift system by moving it upwards Manual closing of the lift system by moving it downwards 6 Collision detection The opening and closing action is interrupted automatically via the integrated colli-
sion detection feature when the front hits a body part or other object. Leaning protection SERVO-DRIVE for AVENTOS also protects against activation when someone leans against the lift system. Leaning on the lift system will not open it. CAUTION Premature wear of SERVO-DRIVE for AVENTOS due to improper use!
Do not press/pull with force against the movement direction when opening or closing the lift system. If the power supply is interrupted during SERVO-DRIVE for AVENTOS motion, the lift system remains in place. Simply touch the Blum switch to reactivate SERVO-DRIVE for AVENTOS. The following are required to ensure the error-free functioning of SERVO-DRIVE for AVENTOS:
Blum spacing bumpers (page 6, item 5) must be attached to the front to main-
tain the required distance between the lift system and the cabinet. No items should be placed between the front and the cabinet and/or drive unit. 7 Blum switch Function The Blum switch is battery-operated (CR2032). Only use batteries from well-known manufacturers. When the battery power begins to weaken, the battery display (LED) begins to flash red. Battery display (LED) Schalter 21P5020 FCC ID: W95-21P5020 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interfe-
rence, and (2) this device must accept any interference received, including interference that may cause undesired operation. Replacing the battery Open the Blum switch Remove the battery Insert new battery Type: CR2032 Please note proper pole connections (+/-) Close Blum switch CAUTION The Blum switch battery must not be recharged or thrown into fire. NOTICE If the battery is inserted incorrectly, the Blum switch battery display flashes red. 8 Blum transformer Power connection Operating mode display
(LED) Serial tag Function The Blum transformer (page 6, item 3) provides power to the drive unit. Blum transformer function can be checked via the operating mode display (LED). The following serial tag can be found on the Blum transformer:
100 W Power Supply Power Supply Model/Modelo/Modelo/
Model/Modelo/Modelo/
Input/Entrada/Entrada/
Input/Entrada/Entrada/
Output/Saida/Salida/
Output/Saida/Salida/
: Z10NE050.01
: Z10NE050.01
: 100-240VAC 50-60Hz 1.5A
: 100-240VAC 50-60Hz 1.5A
: 24VDC 4.17A
: 24VDC 4.17A www.blum.com www.blum.com
.. . TUV TUV Rheinland Rheinland Product Safety Product Safety
.. . geprufte geprufte Sicherheit Sicherheit
.. . TUV TUV R R Rheinland Rheinland OCP 0004 OCP 0004 99BJ EXXXXXX I.T.E. POWER SUPPLY 99BJ E176177 I.T.E. POWER SUPPLY A S S F E T Y M F E T Y M A A A R R K K SM SM R R NYCE NYCE A/S 100-240VAC 50-60Hz 1.5A KTL XXXX-XXXX KTL SU10284-8001 N19650 R R RXXXXX R35323 NSW23080 NSWxxxxxx
.. . TUV Rheinland TUV Rheinland PS PS E E Input : 100VAC 50-60Hz 1.5A Input : 100VAC 50-60Hz 1.5A Output : 24VDC 4.17A Output : 24VDC 4.17A BN:XXYY BN:XXYY SN : XXXXXX-XXXXXX SN:100240-XXXXXX SN:XXXXXX-XXXXXX Made in China/Feito na China/Hecho en China Made in China/Feito na China/Hecho en China 9 Problem Battery display on Blum switch flashes red. SERVO-DRIVE for AVENTOS does not open/close completely. SERVO-DRIVE for AVENTOS does not work for all lift systems when pressing on the front or using the Blum switch. The LED on the Blum transformer does not light. SERVO-DRIVE for AVENTOS does not work for only one lift system when pressing on the front or using the Blum switch. SERVO-DRIVE for AVENTOS functions when pressing on the switch, but not when pressing on the front. SERVO-DRIVE for AVENTOS does not close completely. Fault Diagnosis 4 Possible cause Blum switch battery is losing power. The front (page 6, item 7) is not balanced or does not lie on the cabinet evenly. Switched outlet is turned off Blum transformer (page 6, item 3) is not plugged in. Power outage Blum transformer (page 6, item 3) is defective. Blum switch battery is dead. Battery was inserted incorrectly
(page 6, item 4). Blum switch is defective. Drive unit is defective (page 6, item 1). Cabling is defective. Blum spacing bumper (page 6, item 5) was removed or is defec-
tive. Remedy Replace the battery. Contact your distributor's customer service to readjust the front. Turn on switched outlet. Plug in the Blum transformer to the outlet. Check the circuit breaker/fuse box. If necessary, contact an qualified electrician. If necessary, have the distributor's customer service replace the Blum transformer. Replace the battery type CR2032. Insert the battery correctly (see page 8). Contact your distributor's customer service to replace the Blum switch (page 6, item 4). Contact your distributor's customer service to replace the drive unit. Contact your distributor's customer service to correct the problem. Contact your distributor's customer service to replace the Blum spacing bumper. An object is between the lift system and cabinet or jammed between the lever and front. An object juts out over the front edge of the cabinet. Remove the obstruction. Remove the obstruction. NOTICE If the SERVO-DRIVE for AVENTOS electrical motion support system does not work, the lift systems can still be opened and closed manually they will not be damaged in this way. 10 5 Technical data 5.1 Power supply Input voltage:
100-240VAC / 50-60Hz Input voltage Japan:
100VAC 10% / 50 and 60Hz Output voltage:
24VDC Nominal output current:
3.0A 4.17A Operating temperature:
0 to +40C Protection category:
IP40 Should only be used in dry, enclosed rooms
(Z10NE010.xx)
(Z10NE050.xx) 5.2 Drive unit Supply voltage:
Rated current:
Power consumption in standby mode:
Operating temperature:
Protection category:
Should only be used in dry, enclosed rooms 24VDC 1.4A 0.6W (front closed) 0 to +40C IP20 5.3 Blum switch Frequency:
Transmission method:
Range:
Operating temperature:
Protection category:
Battery supply:
Should only be used in dry, enclosed rooms 2.4GHz Bidirectional, via a coded wire typically 10m (depending on material and contents) 0 to +40C IP20 3V Lithium button cell CR2032 6 Replacement parts Spare parts can be ordered from your distributor or furniture supplier. 7 Disposal SERVO-DRIVE for AVENTOS removal may only be carried out by qualified person-
nel according to the separate installation instructions. All SERVO-DRIVE for AVENTOS electronic components, including the battery, should be disposed of in a separate collection for electrical appliances as per local regulations. 11 Julius Blum GmbH Furniture Fittings Mfg. 6973 Hchst, Austria Tel.: +43 5578 705-0 Fax: +43 5578 705-44 E-mail: info@blum.com www.blum.com Copyright Blum Subject to technical modifications and changes to the range without notice. BAU0013920777 IDX: 00 IDNR: 898.034.0 BA-133/0EN 08.09