AP33 and AP32 Hardware Installation Guide Overview The Mist AP33 and AP32 contains three IEEE 802.11ax radios that deliver up to 4x4 MIMO with four spatial streams when operating in multi-user (MU) or single-user (SU) mode. 1 AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved I/O ports Reset Reset to the factory default settings USB Eth1 USB2.0 support interface 10/100/1000BASE-T RJ45 interface Eth0+PoE 100/1000/2500BASE-T RJ45 802.3at PoE PD interface that supports AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 2 AP33 Mounting In a wall mount installation, please use screws that have a 1/4in. (6.3mm) diameter head with a length at least 2 in. (50.8mm). AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 3 AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 4 AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 5 AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 6 AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 7 The bracket attaches to a rod that is 5/8-11. The bracket attaches to a rod that is M16-2. AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 8 9 AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved Technical Specifications:
Feature Description Power options 802.3at/802.3af PoE Dimensions 202mm x 202mm x 44mm (7.95in x 7.95in x 1.73in) AP33: 0.98 kg (2.16 lbs) AP32: 0.83 kg (1.83 lbs) AP32E: 0.81 kg (1.78 lbs) AP33: -5 to 40 C AP32: -5 to 40 C AP32E: -5 to 40 C Weight Operating temperature I/O RF Operating humidity 10% to 90% maximum relative humidity, non-condensing Operating altitude 3,048m (10,000 ft) 1 100/1000/2500BASE-T auto-sensing RJ-45 with PoE 1 10/100/1000BASE-T auto-sensing RJ-45 1 USB2.0 5GHz - 4x4:4SS 802.11ax MU-MIMO & SU-MIMO 2.4GHz 2x2:2SS 802.11ax MU-MIMO & SU-MIMO 2.4GHz / 5GHz scanning radio AP33 - 2.4GHz BLE with Dynamic Antenna Array AP32/AP32E - 2.4GHz BLE with Omni Antenna Total maximum PHY rate 2974 Mbps 5GHz 2400 Mbps 2.4GHz 574Mbps Maximum PHY rate Indicators Multi-color status LED Compliance standards CAN/CSA-C22.2 No. 62368-1-14 UL 2043 FCC Part 15.247, 15.407, 15.107, and 15.109 RSS-247 ICES-003 (Canada) Suitable for use in environmental air space in accordance with Section 300-22(C) of the National Electrical Code, and Sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1. Warning: The AP must be mounted only horizontally if you mount it into a plenum space. AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 10 Warranty Information The AP33 or AP32 family of Access Points comes with a limited lifetime warranty. Ordering Information:
Access Points AP33-US 802.11ax WiFi and BLE Array AP - Internal Antenna for the US Regulatory domain 802.11ax WiFi and BLE Array AP Internal Antenna for the WW Regulatory domain 802.11ax WiFi and BLE AP Internal Antenna for the US Regulatory domain 802.11ax WiFi and BLE AP Internal Antenna for the WW Regulatory domain 802.11ax WiFi and BLE AP External Antenna for the US Regulatory domain 802.11ax WiFi and BLE AP External Antenna for the WW Regulatory domain Universal AP Bracket for T-Rail and Drywall mounting for Indoor Access Points 5/8-inch threaded rod bracket 16mm threaded rod bracket Adapter for channel rail and recessed 9/16 t-rail Adapter for recessed 15/16" t-rail Adapter for recessed 1.5" t-rail AP33-WW AP32-US AP32-WW AP32E-US AP32E-WW Mounting brackets APBR-U APBR-T58 APBR-M16 APBR-ADP-CR9 APBR-ADP-RT15 APBR-ADP-WS15 APBR-ADP-T12 1/2-inch thread rod adapter AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 11 Regulatory Compliance Information:
This product and all interconnected equipment must be installed indoors within the same building, including the associated LAN connections as defined by the 802.3at Standard. If you need further assistance with purchasing the power source, please contact Mist Systems, Inc. AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 12 FCC Requirement for Operation in the United States of America:
FCC Guideline for Human Exposure This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 40 cm between the radiator & your body. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other FCC Caution antenna or transmitter. AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 13 Industry Canada This device complies with RSS-247 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Ce dispositif est conforme la norme CNR-247 d'Industrie Canada applicable aux appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif ne doit pas produire de brouillage prjudiciable, et (2) ce dispositif doit accepter tout brouillage reu, y compris un brouillage susceptible de provoquer un fonctionnement indsirable. This radio transmitter (IC: 22068A-AP33 / Model: AP32E, AP32, AP33) has been approved by ISED to operate with the antenna type listed below with maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le prsent metteur radio (IC: 22068A-AP33 / Model: AP32E, AP32, AP33) a t approuv par ISED pour fonctionner avec les types d'antenne numrs ci-dessous et ayant un gain admissible maximal. Les types d'antenne non inclus dans cette liste, et dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour l'exploitation de l'metteur. Approved antenna(s) list:
Antenna No. Brand Model Ext WiFi Dual Acceltex ATS-OO-245-46-
Int WiFi Dual Ant Ant 6RPSP-36 Antenna Net Gain (dBi) Frequency range (GHz) Antenna Type Connector Type 4 6 5 6 2.4 2.484 5.15 5.85 2.4 2.484 5.15 5.85 Omnidirectional RPSMA Plug Omnidirectional N/A Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 44 cm between the radiator & your body. Dclaration d'exposition aux radiations:Cet quipement est conforme aux limites d'exposition aux rayonnements IC tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 44 cm de distance entre la source de rayonnement et votre corps. AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 14 IC Caution
(i) The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
(ii) The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall be such that the equipment still complies with the e.i.r.p. limit;
(iii) The maximum antenna gain permitted for devices in the band 5725-5850 MHz shall be such that the equipment still complies with the e.i.r.p. limits specified for point-to-point and non-point-to-point operation as appropriate; and
(iv) Users should also be advised that high-power radars are allocated as primary users
(i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices. Avertissement Le guide dutilisation des dispositifs pour rseaux locaux doit inclure des instructions prcises sur les restrictions susmentionnes, notamment :
(i) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont rservs uniquement pour une utilisation lintrieur afin de rduire les risques de brouillage prjudiciable aux systmes de satellites mobiles utilisant les mmes canaux;
(ii) le gain maximal d'antenne permis pour les dispositifs utilisant les bandes de 5250 5 350 MHz et de 5470 5725 MHz doit tre conforme la limite de la p.i.r.e;
(iii) le gain maximal d'antenne permis (pour les dispositifs utilisant la bande de 5 725 5 850 MHz) doit tre conforme la limite de la p.i.r.e. spcifie pour l'exploitation point point et lexploitation non point point, selon le cas;
(iv) De plus, les utilisateurs devraient aussi tre aviss que les utilisateurs de radars de haute puissance sont dsigns utilisateurs principaux (c.--d., quils ont la priorit) pour les bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL. AP33 or AP32 Hardware Installation Guide Mist Systems (C) Copyright 2020. All Rights Reserved 15