1 OVERVIEW 2 KEY FEATURES 5 SAFETY PRECAUTIONS 6 OPERATION GUIDE ACTIVE sanitization Plascide Micro-lightning process Anti-germ & VOCs technology NO EXOTIC FILTERS No expensive, special or exotic filters required A simple fine dust filter for ease of mind RAPID EFFECTIVENESS Where every breath counts, Sanitise within seconds WIFI CONTROL Control and monitor your ROOM wherever you are PACKAGE CONTENT 3 1. 2. 3. 4. 5. Manual & Warranty Card 6. Magnetic Feet (x4) airKAVE ROOM Fine Dust PM 2.5 filter (Type: E12 or H13) Air-vent Large Dust filter (Washable) Power supply adapter QUICK START 4 Preparation before use:
1. 2. 3. 4. Plug power supply adapter into wall socket Plug barrel type connector into ROOMs back power port Press or Button until LED indicator turns green Tap button to change sanitization power level 1. Handle with care when transporting or moving 2. ROOM can be damaged if dropped, burned, punctured or crushed 3. Do not operate if damaged and / or when any parts are broken to avoid potential injury 4. Power with the included power supply adapter only 5. Do not operate with damaged connectors, cables or power supply adapter 6. During operation or storage keep indoors and dry 7. Do not operate if wet and / or immersed in any liquid to avoid potential injuries and/or damages to properties 8. Do not allow infants and young children to operate unsupervised 9. Keep magnetic feet away from infants, young children and animals as they can be choking hazards 10. Do not insert any objects into the In or Out air-vents 11. Do not operate without any parts attached or any panels left open 12. Close left side panel and ensure all filters are seated correctly before operating 13. Do not block the In or Out air-vents during operation 1. Function Button Turn ON / Hold to turn OFF | Tap to cycle modes 2. Selection Button Turn ON | Tap for function options 3. Top LED Indicator Mode & Power Level displays 4. Front Out Air-vent Clean air exits here 5. Back In Air-vent Contaminated air enters here 6. Back Power Port Barrel type socket 6.1 Function Button Tap or to turn ON the ROOM. To turn OFF, press and hold for a few seconds. Tap to cycle the modes, LED will flash to different colours when cycled. 6.2 Mode Selection Immediately after turning on, default mode is set to Manual. 6.4 sanitization Power Levels In Manual, Program and Timer modes, press to cycle through the power levels. In Program mode, you can configure each schedule to a specific sanitization power level, for any time and day. For more details, see: 7.6 Configure: Program In Econ mode, sanitization power level is automatic and cannot be manually changed during operations. POWER DESCRIPTION 7 WIFI CONTROLS Remotely control and customise settings for Timer & Program mode from a web browser on a PC, Mobile or Android app from google Play Store. Step-by-Step Control Guide, please see: 11.4 Support Plug Power Supply into the ROOM & the Wall Socket WIFI Hotspot (WIFI4 / 2.4GHz) will turn on automatically when connected to power supply. Ensure the Indicator LED is lit RED. 7.1 Quick Connect Guide 7.2 Control Panel On/Off Turn the ROOM to Standby mode Mode/Power Status Display current status here Modes Switch to Manual/Timer/Program/Econ Power Level User can take manual control Advance Panel Access by Gear icon (Top Right) Logout Return to login page Cross icon (Top Left) Switch modes to Manual, Timer, Program or ECON:
Click Manual, Timer, Program or ECON button to activate. You can change to manual mode by:
CONNECT BY ANDROID APP Download on Google Play Store (QR Link):
https://play.google.com/store/apps/details?id=com.aonetech.airhalo 1. 2. Click manual button or Select a sanitization power level Press button to apply manual mode 1 2 3 4 5 SILENT LOW BOOST OFF Quiet comfort & Sleep Low power for relaxing study A. B. NORMAL Everyday optimized power At the home screen, press Refresh button to search for your ROOM. A list of available WIFI HOTSPOT will be displayed Max coverage for demanding situation Turn OFF (Program Mode Only) C. WIFI HOTSPOT name (SSID) is Model No. + Serial No. Please see product label for details ( AHD01SXXXX ) 6.3 Mode Indicator LED MODE DESCRIPTION 6.5 sanitization Power Indicator sanitization power LEDs are shown in GREEN. Mode LED will be shown in different colours. See: 6.3 Mode Indicator D. On the list display select the ROOM you wish to control, this will load the login page: See Step 3 Below Connect by Web Browser 1. Connect to ROOMs WIFI hotspot manually: See Step D 2. In your web browser search bar, type the IP address:
RED OFF Fan & sanitization Off, WIFI in Standby WHITE MANUAL Direct control by user BLUE PROGRAM Time & Day schedule set by user YELLOW TIMER Turn off after a set duration GREEN ECON Pre-programmed optimized performance In Manual, Timer and Program mode, sanitization power levels can be adjusted manually from the ROOM interface. In Econ mode, sanitization power level is automatically set and cannot be manually adjusted. See:
6.3 Mode Indicator MODE LED LEVELS POWER LED INDICATOR x4 Power LED SILENT LOW NORMAL BOOST 192.168.100.1 Set specific options from the Configure and System group. Clicking on the button will take you to the specific panel options. 3. 4. After connecting by android app or web browser, The ROOM login page requires Username & Password Default Username: admin Default Password: admin Only one user can control remotely (App/Browser) Log out (Top left) to allow another user to connect Device use 2.4GHz band. Interference may occur in congested areas. If unable to connect to Hotspot, Switch off other devices and/or move to a less congested WIFI area. Please see: 11. Troubleshooting For online Step-by-Step Control Guide, please see: 11.4 Support LED Brightness can be set for all indicator LEDs Ranging from Off, Dim, Normal or Bright Set Brightness:
1. 2. Select brightness option from drop down menu Selection will be applied immediately Reset - !Warning!
Selecting this option will restore all software to factory default. Please see for more details: 11.1 Troubleshooting 7.3 Advance Panel Device Name Display name of the ROOM Login Password Set custom password Configure Configure options for specific modes System Configure device settings Bright Set the brightness of the LEDs indicator Reset Apply factory default Set new Device Name and/or Login Password:
1. 2. 3. 4. Select the ROOM name/Login Password field Enter a new alphanumeric entry Click Apply to set new name/password Click Back to return to Control Panel 7.4 Configure: Timer Timer mode automatically shutdown the ROOM within a set duration when activated. Configure the duration of the timer in hours and minute incrementation:
1. Select hours from 00hrs to 24hrs and Select minutes from 00mins to 59mins Select sanitization power level by tapping Click Apply Click Back to return to Advance Panel 2. 3. 4. 7.5 Configure: Program Enable PROGRAM mode from OFF mode:
button Press twice to select Program mode: press to cycle sanitization power level until ROOM enters OFF mode. Please see for further details: 6.4 sanitization Power Levels Program allows ROOM scheduling for the entire week. Set time, day of the week and the sanitization power level. Please ensure the Time and Day is set to your time zone before utilising PROGRAM mode. To configure:
1. 2. 3. 4. 5. Select the time in hours and minutes (HH:MM am/pm) Select the sanitization power level (Off / Silent / Low / Normal / Boost) Select the day or days (Monday to Sunday) Click Apply Click Back to return to Advance Panel Delete a schedule, click Delete on the far right side. 30 programs can be scheduled. For further details please go to our website for the latest manual: www.air-halo.com 7.6 System: Clock To ensure Program mode is running correctly, set ROOM to your current time zone. To configure:
1. 2. 3. 4. Set Hours, Minutes and AM/PM Set date (DD-MM-YYYY) Click Apply Click Back to return to Advance Panel 7.7 System: Network Connect to WIFI HOTSPOT for First Time Initiation of ROOM Default format is Product No. + Serial No. ( AHD01SXXXX ). This can be found on the product label. The Hotspot operate on the 2.4GHz band. SSID name and password is fully customisable. WIFI Local Area Network (WLAN) on a home router WLAN is compatible with WPA and WPA2 encryption To connect:
1. 2. 3. 4. Click Search WIFI to discover available networks Click SSID to select desired network Enter password Click Apply or Reboot Multiple ROOMs can connect to the same WIFI Local Area Network
(WLAN) on a home network. The WLAN IP of the ROOM will be displayed on the Login page 7.8 System: Firmware Customer support may direct user to update the firmware if required. Please see : 11.4 Support 8 MAGNETIC FEET ROOM can be positioned vertically or horizontally on the right side panel. Side Position:
Attach magnetic feet to the right side panels at the four corners indicated. Bottom Position: Attach magnetic feet to the bottom panel at the four corners indicated. 9 MAINTENANCES 9.1 Cleaning Recommendation Before cleaning, please switch OFF & Unplug Power Supply Surfaces: Slightly damp cloth In/out-vent Metal Mesh: cloth & vacuum Large Dust Filter: vacuum & rinse with water (periodically) 9.2 Surfaces Use a slightly damp cloth to wipe clean any blemish or dirt on the surface. 9.3 In & Out-vent Mesh Vacuum the mesh carefully, use a cotton bud to remove dust from between the vents. 9.4 Large Dust Filter 1. 2. 3. Wash clean with water & dry Position horizontally with left-side panel on top Lift the top side panel & gently remove large dust filter 4. 5. 6. thoroughly before replacing Vacuum clean any dust or obstruction within Align large dust filter with tabs facing outwards and push down until it clicks Close the top side panel until it clicks 9.5 Fine Dust Filter Replacement It is recommended to replace fine filter (Type: E12 or H13) every 6-9 months. Before replacement, carefully vacuum around and inside the interior. CAUTION: Do not remove Fine Dust filter without unplugging power supply first. 11 SERVICE & SUPPORT 11.1 Troubleshooting Symptom Diagnosis No LED ON, No Fan 11.2 Hard Reset If you have exhausted all possible solutions to fix your problem. You can perform a hardware reset to restore the factory defaults Plug Power Supply into the ROOM & the Wall Socket:
ROOM AIR SANITIZER EN INSTRUCTION MANUAL Model: AHD01 1. Lift the front edge of the No LED ON, Fan On To replace the fine dust filter, position with left-side panel on top:
left-side panel 2. Grip firmly to remove and pull out the fine dust filter 3. Align replacement filter and push until it is flush with the opening Action Plug All Power Supply
& Cables Into Socket Securely Tap Buttons For LED Response Please See:
6.1 Function Button Power Cable Not Secured Low-light Setting On Low -Light With Timer/Program Mode Activated No Button/Fan Response Rattling Fan, Loud Fan Noise Left Side Panel Not Closed &
Loose Magnetic Feet Close All Panels
& Attach Supplied Feet Please See:
8 Magnetic Feet Fan Is On But No Air Flow Large Dust Filter Need Cleaning Please See:
9.4 Large Dust Filter Fan Is On, Large Dust Filter Cleaned But No Air Flow All Red LED Flashing All Red LED, No Fan, No Button Response No LED or Button Response With Cable Plugged Program Mode Not Keeping the correct schedules Time & Date not Correct After Every Power Reset Fine Dust Filter Need Cleaning Please See:
9.5 Fine Dust Filter Replacement Product Fault Apply Factory Default Or Please See:
11.3 Warranty Factory reset If persistent Please See: 11.4 Support 9.6 Fine Dust Filter Disposal When fine dust filter is full, do not incinerate. Disposed separately from household waste. 9.7 Repair Maintenance by user is not advised. For more details please see:
11.2 Warranty 10 SPECIFICATIONS sanitization Power Levels: Silent / Low / Normal / Boost Model: AHD01 Modes: Manual / Timer / Program / ECON WIFI: 802.11 b/g/n @ 2.4GHz (WIFI 4) Weight: 5kg Air sanitizer: Plascide Technology Recommend Usage: 250ft2 Supply: 100-220V@50/60Hz | Output: 12V 5A Consumption: 60W Dimension (283 x 333 x 140)mm 1.Lift up left side panel 2.Locate the first hole labelled: Recover 3.Insert a pen or screwdriver 4.Press down firmly for a second ROOM is covered by a manufacturer guarantee and warranty Self-repair and/or signs of tampering will void the warranty Repairs should only be carried out by a certified person Please refer to the included warranty card for more details 11.3 Warranty 11.4 Support For latest documentation: support@airkave.com Please contact your local service centre:
T: 800-873-1038| W:WWW.AIRKAVE.COM|
KAVE INDUSTRIES LLC 8605 Santa Monica Blvd #53476, Los Angeles, CA 90069 Caution: This device complies with part 15 of the FCC Rules, Industry Canada license-exempt RSS standard(s) and with Part 18 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or change to this equipment. Such modifications or change could void the users authority to operate the equipment. Airkave and the included wireless Hotspot has been tested and found to satisfy the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Airkave generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures:
The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCCs RF exposure guidelines, the distance must be at least 20 cm between the radiator and your body. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The included wireless airkave has been tested and found to comply with the applicable limits under Part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference to licensed radio services. However, the airkave generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation. If this airkave does cause harmful interference to radio or television reception, or to another authorized radio service, which can be determined by turning the Charger off and on, the user is encouraged to correct the interference by one or more of the measures described immediately above. IC Warning: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference, including interference that may cause undesired operations of the device. Le prsent appareil est conforme aux CNR dlndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes: (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. The device has been evaluated to meet general RF exposure requirement. To maintain compliance with RSS-102 --- Radio Frequency (RF) Exposure guidelines, this equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. Le dispositif de a t valu rpondre gnral rf exposition exigence. Pour maintenir la conformit avec les directives dexposition du RSS-102-Radio Frquence
(RF). Ce matriel doit tre install et exploit une distance minimale de 20 cm entre le radiateur et votre corps. Advisory Statement: This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. UL Warning: To reduce the risk of injury, user must read instruction manual. Use only with Listed/Certified ITE Power Supply FCC ID: 2AZLG-AHD01R | FCC ID: 2AZLG-AHD01M| IC ID: 27178-AHD01 Plascide Plasma Technology 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. OVERVIEW KEY FEATURES PACKAGE CONTENT QUICK START GUIDE SAFETY PRECAUTIONS OPERATION GUIDE WIFI CONTROLS MAINTENANCES MAGNETIC FEET SPECIFICATIONS SERVICE & SUPPORT SUBJECT TO CHANGE WITHOUT PRIOR NOTICE WIFI not connecting Forgot login password Hardware reset Please See:
11.2 Hard Reset PLEASE READ THIS MANUAL BEFORE USE