User Manual Date Rev 2018-10-01 1.4 DOTR-3000 User Manual Co., Ltd All rights reserved. 1 User Manual Date Rev 2018-10-01 1.4 CONTENTS CONTENTS ........................................................................................................................................ 2 DOTR-3000 INTRODUCTION ....................................................................................................... 4 Additional Relevant Manual ................................................................................................................................... 4 Service Information ..................................................................................................................................................... 4 Technical Specifications ............................................................................................................................................. 5 MAIN PARTS ..................................................................................................................................... 6 DOTR-3000 POWER ON/OFF ..................................................................................................... 10 GUN TRIGGER ................................................................................................................................ 11 HID BASIC OPERATION ............................................................................................................... 12 ANDROID BLUETOOTH ................................................................................................................ 14 BASIC OPERATION FOR ANDROID APPLICATION ............................................................... 15 1. ANDROID TEST PROGRAM ................................................................................................. 15 1.1. Config Tab ................................................................................................................................................ 15 1.1.1. Bluetooth ................................................................................................................................................... 16 1.1.2. Search Reader ......................................................................................................................................... 16 Co., Ltd All rights reserved. 2 User Manual Date Rev 2018-10-01 1.4 1.1.4. Device Config .......................................................................................................................................... 20 1.1.5. UHF RFID Config ................................................................................................................................... 20 1.1.6. Factory Reset ........................................................................................................................................... 28 1.1.7. Scanner Config ....................................................................................................................................... 29 1.1.8. RFID Button .............................................................................................................................................. 30 1.1.9. Delete Button .......................................................................................................................................... 31 1.2. App ............................................................................................................................................................... 32 1.2.1. Read Tag .................................................................................................................................................... 32 1.2.2. Write Tag ................................................................................................................................................... 33 1.2.3. Single Search Tag ................................................................................................................................. 33 1.2.4. Multi Search Tag ................................................................................................................................... 34 1.2.5. Wildcard Search Tag ........................................................................................................................... 34 2. PC TEST PROGRAM ............................................................................................................... 36 2.1. Program Introduction ......................................................................................................................... 36 2.2. User Interface information .............................................................................................................. 36 2.3. How to Use .............................................................................................................................................. 37 Co., Ltd All rights reserved. 3 User Manual Date Rev 2018-10-01 1.4 DOTR-3000 Introduction This document provides information on using the DOTR-3000 functions and accessories. DOTR-3000 is a UHF (900MHz) RFID and Scanner Reader that quickly recognizes EPC Global Gen2 compliant RFID tags. The recognized results are transmitted to your smartphone, tablet, PC, etc. via USB and Bluetooth, both wired and wirelessly. Additional Relevant Manual RSP Interface Programmers Guide Service Information If you have a problem with your equipment, please contact KCTNS support in your area. For contact information, please visit http://www.dotel.com/company/contact.asp You should have the following information ready when you contact support:
Serial number of the equipment (Displayed on product label) Product name or model name(Displayed on product label) KCTNS will respond to your inquiries by e-mail, telephone or fax within the time limit specified in the support contract. If KCTNS Support is unable to resolve your issue, you may need to return your equipment to receive service. In these cases, specific instructions are provided. KCTNS shall not be liable for any damages incurred during carriage unless approved transport packaging is used. Improper shipment of the equipment may invalidate the warranty. Co., Ltd All rights reserved. 4 User Manual Date Rev 2018-10-01 1.4 Technical Specifications RFID Communication etc. Item Description Reader Chip Impinj R-2000 chipset Frequency UHF 900MHz (902.75 ~ 927.25 MHz) Protocol Output USB Bluetooth HID LED Button Buzzer Size Battery Drop Adaptor EPC Global Gen2 ISO 130000-6C TBD USB Type C / USB to Serial Communication Bluetooth v4.1(Classic + Low Energy) 2402 ~ 2480 MHz HID support LED(Charge / Power / Sync / Status) Power, Mode Max, Min, Mute 70 x 139 x 115.8 / Option 70 x 129 x 115.8mm (W x H x D) 3,350 mA, 3.6V Li-ion 1.5M 5V / 2A Waterproof IP52 Weight 1W, 250mW : 338g Co., Ltd All rights reserved. 5 User Manual Date Rev 2018-10-01 1.4 Main Parts 4 1 2 3 5 1. UHF RFID Antenna 2. Power Key 3. Mode Key 4. Trigger Key 5. Gun Grip / internal battery Co., Ltd All rights reserved. 6 User Manual Date Rev 2018-10-01 1.4 Main Parts 1 2 3 4 1. USB type-C Charge Slot 2. Hand Strap Slot 3. LED Status 4. Strap Slot Note : Battery replacement only available by Manufacturer. Co., Ltd All rights reserved. 7 Main Parts User Manual Date Rev 2018-10-01 1.4 1 2 3 4 Main Parts Status Charge Power Charging Fully Charged Power On Low Battery Bluetooth Pairing LED RED GREEN RED RED Blink GREEN Low Battery while Bluetooth Paired GREEN Blink PC USB Connection ORANGE LED Low Battery while connected to PC USB ORANGE Blink SPP Connection for Bluetooth Pairing RED HID Connection for Bluetooth Pairing GREEN Mode(Sync) App Connection for Bluetooth Pairing ORANGE USB Connection ORANGE Low Battery while connected to USB ORANGE Blink Status UHF RFID Ready Barcode Scan Ready RED GREEN Co., Ltd All rights reserved. 8 User Manual Date Rev 2018-10-01 1.4 Note : At 10% Battery, a beep sound occurs every 70 seconds. At 5% and below, a beep sound occurs every 7 seconds. At 0% Battery, Protection Mode is enabled. Protection Mode : At 0% Battery, the device and its LEDs are all turned off automatically.
-
- DOTR-3000 will not turn on when fully discharged (Protection Mode). Co., Ltd All rights reserved. 9 User Manual Date Rev 2018-10-01 1.4 DOTR-3000 Power On/Off Power On 1. Press and hold Power key for approximately 2 seconds while device is power off. 2. DOTR-3000 will power on. Note : In case you are not able to power on DOTR-3000, please follow the next step.
-
In order to power on DOTR-3000, it must be charged adequately. Charge first. Power Off 1. Press and hold Power key for approximately 2 seconds while device is powered on. 2. DOTR-3000 will power off. Co., Ltd All rights reserved. 10 User Manual Date Rev 2018-10-01 1.4 Gun Trigger Trigger Note : DOTR-3000 needs to be connected to HID, Bluetooth or PC Program for the trigger to function accordingly. The trigger of a powered-on DOTR-3000 without any connection will not operate UHF RFID features. Co., Ltd All rights reserved. 11 User Manual Date Rev 2018-10-01 1.4 HID Basic Operation
- Press DOTR3000-XXXXXX
- Registering the DOTR-3000 Co., Ltd All rights reserved. 12 User Manual Date Rev 2018-10-01 1.4 HID Basic Operation
- Tap PAIR
- Check for Connected below the DOTR-3000 Co., Ltd All rights reserved. 13 User Manual Date Rev 2018-10-01 1.4 Android Bluetooth Android Connection Note : HID does not operate while the DOTR-3000 is connected to Android Application.
- Connecting PC USB while Bluetooth paired will disconnect the Bluetooth pairing of DOTR-
3000. Co., Ltd All rights reserved. 14 User Manual Date Rev 2018-10-01 1.4 Basic operation for Android application 1. ANDROID TEST PROGRAM This article will explain how to use the Android application for DOTR-3000. 1.1. Config Tab Config Tab is a for device connection and UHF RFID configuration
[Config Tab]
Note : Opening the Application will automatically re-connect to the device from the last session. Co., Ltd All rights reserved. 15 User Manual Date Rev 2018-10-01 1.4 1.1.1. Bluetooth If the Bluetooth on the Android device is Off, only the Bluetooth button becomes active. Pressing the button will turn on Bluetooth. When the Bluetooth is on, "Connect Reader" and "Search Reader" Button turn active.
[Bluetooth Off]
[Bluetooth On]
1.1.2. Search Reader Press "Search Reader" Button to search device. Device search begins as the button is pressed.
[Search Reader Button]
Co., Ltd All rights reserved.
[Search Devices]
16 User Manual Date Rev 2018-10-01 1.4 1.1.2.1. Search Reader Device connection After the device search is finished, devices found will be displayed on the list. Select the device in need of connection. Press "Connect" Button to connect with device or Click the "Cancel" Button to close the window. Press the button at the top right to search for devices.
[Before connecting to device]
[Confirm device connection]
[Status of connection]
Co., Ltd All rights reserved. 17 User Manual Date Rev 2018-10-01 1.4 1.1.2.2. Search Reader Disconnection Select the Connected device on the Device List. A window will appear asking confirmation to disconnect. Click "Disconnect" to disconnect.
[Confirm to disconnect]
[Status of connection ]
[Status of Disconnection]
Co., Ltd All rights reserved. 18 User Manual Date Rev 2018-10-01 1.4 1.1.3. About The current version of the application and device can be checked. Click on Sub Menu button on the upper right. Click on About for Application Version and Device Version.
[About Button]
[Sub Menu Button]
[Information]
Co., Ltd All rights reserved. 19 User Manual Date Rev 2018-10-01 1.4 1.1.4. Device Config Tap "Device Config" Button to change the set-up for Device Configuration.
[Device Config Button]
[Device Config Menu]
1.1.5. UHF RFID Config Tap "UHF RFID Config" Button to change the set-up for UHF RFID Configuration.
[UHF RFID Config Button]
[UHF RFID Config Menu]
Co., Ltd All rights reserved. 20 User Manual Date Rev 2018-10-01 1.4 1.1.5.1. Session You can change UHF RFID Session setting of the device (0 ~ 3). Session is the returning time that the inventory flag of the tag returns A to B and back to A. Set the time taken to re-read the tag once read for Multi Reading.
[Session Button]
[Session set-up Menu]
Co., Ltd All rights reserved. 21 User Manual Date Rev 2018-10-01 1.4 1.1.5.2. Q You can change the UHF RFID Q settings of the device from (0 to 15). The lower value is fit to read small amount of tags faster. The higher value can read more tags at a time. In case of multi reading, setting value 5 is best option to stable reading speed
[Q Button]
[Q set-up Menu]
Co., Ltd All rights reserved. 22 User Manual Date Rev 2018-10-01 1.4 1.1.5.3. Target Change the device UHF RFID Target settings (A, B, AB). Set the Inventory Flag of the tag to be read. A mode is best option for Multi Reading, and AB is the best option for quick single reading.
[Target Button]
[Target Set-up Menu]
1.1.5.4. Radio Power It can be changed UHF RFID TX Power of the device (30dBm ~ 0dBm). Reading distance is adjustable to TX power level. At Max 30dBm, reading distance can be longer but battery consumption will increase
[Radio Power Button]
[Radio Power set-up Menu]
Co., Ltd All rights reserved. 23 User Manual Date Rev 2018-10-01 1.4 1.1.5.5. TX Cycle The UHF RFID TX Cycle of the device can be changed (20% to 100%). Set up reading speed for the tag. Higher cycle rate increases reading speed for tag but the battery consumption is increased. Recommended setting is below 40%.
[Tx Cycle set-up Menu]
[Tx Cycle Button]
1.1.5.6. Inventory Config Configuration for reading UHF RFID Tag
[Inventory Config Button]
[Inventory Config Menu]
Co., Ltd All rights reserved. 24 User Manual Date Rev 2018-10-01 1.4 1.1.5.7. Inventory Mode Setting for UHF RFID Tag Reading Mode (Continuous or Single). In Single mode, device will stop reading after 1 tag is read.
[Inventory Mode Button]
1.1.5.8. Inventory Timeout Setting for UHF RFID Tag Reading Time. (Unlimited ~ 120min) Tag read will stop when timer reaches 0. Setting the timer to 0 will allow unlimited time for tag reading.
[Inventory Timeout Button]
[Inventory Timeout set-up Menu]
Co., Ltd All rights reserved. 25 User Manual Date Rev 2018-10-01 1.4 1.1.5.9. Report Time Setting for Read Time output when UHF RFID Reading takes place. (Enable / Disable) Read time of the Tag will be transmitted based on the time the reader started reading. If enabled, same tags will be read with different value.
[Report Time Button]
1.1.5.10. Report RSSI Setting for RSSI (Received Signal Strength Indication) when UHF RFID Reading takes place. (Enable /
Disable) Tag distance based on the reader will be transmitted. If enabled, same tags will be read with different value.
[Report RSSI Button]
Co., Ltd All rights reserved. 26 User Manual Date Rev 2018-10-01 1.4 1.1.5.11. Tag Focus Setting for Tag Focus function. (Enable / Disable) Only applicable for Impinj Monza Series and Tag Focus enabled Tags. Available when the device setting is on Session 1 / Target A Mode. Tags are read once, enhancing Multi Reading for various tags.
[Tag Focus Button(Inactive)]
[Tag Focus Button(Active)]
1.1.5.12. Fast ID Setting for FastID function. (Enable/Disable). This mode improves inventory check time based on TID while getting TID value during inventory.
[FastID Button]
Co., Ltd All rights reserved. 27 User Manual Date Rev 2018-10-01 1.4 1.1.5.13. Data Format Setting for Data Format Output of UHF RFID Tag Reading.
[Data Format Button]
[Data Format set-up Menu]
1.1.6. Factory Reset Reset UHF RFID settings of the device. Tap "YES" button to proceed.
[Factory Reset Button]
[Factory Reset Window]
Co., Ltd All rights reserved. 28 User Manual Date Rev 2018-10-01 1.4 1.1.7. Scanner Config If you are connected to DOT-PM80, pressing "Scanner Config" will pop up the scanner setup window on your device and will be disabled on connection to another device. Co., Ltd All rights reserved. 29 User Manual Date Rev 2018-10-01 1.4 1.1.8. RFID Button Tap "RFID" button to read the UHF RFID Tag around. Scanned Tags are updated on the list. Re-read counts and total count are shown on the right side. Press Stop button to stop UHF RFID Tag Reading.
[Tag Reading]
[RFID Button]
[Stop Button]
Co., Ltd All rights reserved. 30 User Manual Date Rev 2018-10-01 1.4 1.1.9. Delete Button To delete the list, tap the "Delete" icon. Tap YES to proceed with deletion.
[Delete Button]
[Delete]
[Confirmation Delete]
Co., Ltd All rights reserved. 31 User Manual Date Rev 2018-10-01 1.4 1.2. App App menu provides search feature for UHF RFID Tag Memory Read / Write / Tag.
[App Tab]
1.2.1. Read Tag Read Tag function enables memory data reading of UHF RFID Tag. EPC / TID / PASSWORD / USER data are read according to their format.
[Read Tag Button]
[Read Tag Menu]
32 Co., Ltd All rights reserved. User Manual Date Rev 2018-10-01 1.4 1.2.2. Write Tag Write Tag function enables memory data writing of UHF RFID Tag Data can be written in the memory of EPC / PASSWORD / USER area according to the specified format.
[Write Tag Button]
1.2.3. Single Search Tag
[Write Tag Menu]
Single Search Tag function enables tracking of specific Tag while reducing TX Power.
[Single Search Tag Button]
[Single Search Tag Menu]
Co., Ltd All rights reserved. 33 User Manual Date Rev 2018-10-01 1.4 1.2.4. Multi Search Tag Multi Search Tag function enables search for registered tags. (up to 50)
[Multi Search Button]
[Tag Add / Delete]
[Edit List]
[Tag Search]
1.2.5. Wildcard Search Tag Co., Ltd All rights reserved. 34 User Manual Date Rev 2018-10-01 1.4 Wildcard Search Tag function enables the use of *,? wildcards to search for specific tags.
[Multi Search Button]
[Tag Add / Delete]
Co., Ltd All rights reserved. 35 User Manual Date Rev 2018-10-01 1.4 2. PC Test Program 2.1. Program Introduction This program (RFIC_CMD) provides easy and simple test of Command (RSP Interface) required for device operation and Key Emulator function to use device as wired HID. 2.2. User Interface information Serial Port Drop Down Menu RSI Command List Send Command Button RSP Command Properties Window Transmit/Receive Data Clear Button Key Emulator Mode Checkbox RFID Multi Mode Setting Save Button COM Port Open Button Input Command Drop Down Menu Transmit/Receive Data Window RSP Command Description Window Auto Connect Checkbox ASCII Mode Checkbox TX Power Adjustment Slide Co., Ltd All rights reserved. 36 User Manual Date Rev 2018-10-01 1.4 2.3. How to Use Select the serial port through the serial port drop down menu. If it is connected via USB, Magconn cable, or Bluetooth, a port that can connect with the device program will be created. (The port number may differ from the illustration below) Press the Open button and the connection will be changed as shown below.
(Open Port button to Close Port button on) You can select the command to transfer to device from RSP command list. Please refer to the
"RSP Interface Programmers Guide" for command and detailed explanation. You can input Command directly from the Input Command drop down menu.
[Note] You can use the Command only if the serial port is properly connected.
[Note] Programs General Commons > Open_Comm command must be executed first. Commands can be sent to the device through the command transfer button. You can check the result of command transmission /reception from Transmit / Receive window.. Through RSP command property window, Properties for command selected in RSP command list are displayed. Parameter properties can be changed by the user. Explanation of the command selected in the RSP command list is displayed through the RSP command description window.. Receive data window Transmit / Receive data window can be cleared by the clear button. Co., Ltd All rights reserved. 37 User Manual Date Rev 2018-10-01 1.4 When checked, it will automatically connect to the last connected serial port when executing the program, and send "Open_Comm" command to make it ready to send commands to the terminal. When checking, data value of RFID or scanner is transferred to the currently active window
(window with cursor)
[Note] The value may look different depending on the state of language. (Default: English) When checked, RFID Tag value is converted into ASCII character and displayed. When cleared, it is displayed as HEX character.
[Note] If the RFID Tag value is not in ASCII format, it may be displayed as an invalid character. Select RFID operation mode (Multi/Single). When Multi Mode is selected, multiple tags are read while the RFID button is held down. When Single Mode is selected, only one tag is read. Adjust the TX output of the DOTR-3000. The tag read distance is adjusted according to the TX output.
[Note] If TX output is too small, the RFID tag may not be recognized. Save the current setting value of the program as XML. Co., Ltd All rights reserved. 38 User Manual Date Rev 2018-10-01 1.4 This device comply with part15 of FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device & its accessories must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Part15.21 statement Changes or modifications not expressly approved by the manufacturer (or party responsible) for compliance could void the users authority to operate the equipment. RF Exposure This device complies with RF exposure requirement. Co., Ltd All rights reserved. 39