Issue departmentBedding Division ProductFunction instruction MC121 Date Author 2018-03-26 Kyle No Version 1.1 Page 1 of 3 MC121Functioninstruction 1. Electricalconfigurationdiagram FCC ID:PCU-RF258GA IC:21319-RF258GA 2. FunctionPicture 1. Processoftest 1.1. HEADport Connecttoheadactuator,controlbyremotesingle:
Clickhead upbuttonontheremote,headactuatormovesout,stopwhenreleased Clickheaddownbuttonheadactuatormovesin,stopwhenreleased Thisfunctiontakeseffectonlybypressingthecorrespondingbuttonontheremote. 1 Date Author 2018-03-26 Kyle No Version 1.1 Page 2 of 3 Issue departmentBedding Division ProductFunction instruction MC121 1.2. FOOTport Connecttofootactuator,controlbyremotesingle:
Clickfoot up buttonfootactuatormovesoutstopwhenreleased Clickfoot downbuttonfootactuatormovesinstopwhenreleased Thisfunctiontakeseffectonlybypressingthecorrespondingbuttonontheremote. 1.3. Massage Connecttoheadmassage,controlbyremote:
Clickheadmassage+button,headmassagestrengthensbyonelevel;
Clickheadmassagebutton,headmassageweakenbyonelevel;
Thisfunctiontakeseffectonlybypressingthecorrespondingbuttonontheremote. 1.4. MULTIFUNCTIONport ConnectwiththesameOtheraccessories;
1.5. PowerLED&PAIRINGLED Powersupplyforcontrolbox,PAIRINGLEDofcontrolboxflashesfor4times,andthenturnsoff,POWERLEDturns on 1.6. Power Connecttothe29VDC;
1.7. PairFunction PowerupcontrolboxpairingLEDwillbeflashthecontrolboxentersintomodeofcodeparing PressandholdtheparingLEDofRemote,thebacklightofparingLEDflashes,thebacklightofremoteflashes,the remoteentersintomodeofcodeparing;
ThebacklightofparingLEDofremotestopsflashing,andtheparingledofcontrolboxstopflash,itindicatesthat thecodeparingissuccessful;
Iffails,repeatalltheprocessesabove;
1.8. FLATfunction PressandreleasetheFLAT buttononremotetheheadandfootactuatorsmovestolowerposition(whenthe actuatorisfree,canturnoffthevibrationmotorandturnofftheindicatorlightwhenpressonce)stopwhen pressanybuton Thisfunctiontakeseffectonlybypressingthecorrespondingbuttonontheremote. 1.9. ZEROGpositionfunction PressandreleaseZERO Gbuttononremotetheheadandfootactuatormovestopresetmemorypositionstop whenpressanybutton 2 Issue departmentBedding Division ProductFunction instruction MC121 Date Author 2018-03-26 Kyle No Version 1.1 Page 3 of 3 Thisfunctiontakeseffectonlybypressingthecorrespondingbuttonontheremote. FCC Any Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. ISED RSS Warning:
This device complies with Innovation,Science and Economic Development Canada licenceexempt RSS standard(s). Operation is subject to the following two conditions:
(1) this devicemay not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'ISED applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. ISED RF exposure statement:
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Le rayonnement de la classe b repecte ISED fixaient un environnement non contrls.Installation et mise en uvre de ce matriel devrait avec changeur distance minimale entre 20 cm ton corps.Lanceurs ou ne peuvent pas coexister cette antenne ou capteurs avec dautres. 3