Keysight U1117A IR-to-Bluetooth Adapter Operating Instructions The Keysight U1117A Infrared (IR)-to-Bluetooth1 adapter is designed to be used with the Keysight U1200 Series handheld meters. The U1117A adapter enables you to connect the handheld meter to the Keysight U1115A remote logging display or Windows PC/Android devices/iOS devices via the Keysight mobile application/PC application software for a total wireless remote connectivity solution of up to 100-metres2. Keysight U1200 Series handheld meters U1117A IR-to-
Bluetooth adapter U1177A IR-to-
Bluetooth adapter Windows PC Android devices iOS devices U1115A remote logging display Keysight PC Application Software Keysight Handheld Meter Logger Keysight Mobile Application Keysight Mobile Meter Keysight Mobile Logger Figure 1. Keysight wireless remote connectivity solution Standard Shipped Items Checklist The following items are included when you make a purchase:
U1117A IR-to-Bluetooth adapter Two 1.5 V AAA batteries Operating Instructions (this sheet) 1 The Bluetooth word mark and logos are registered trademark owned by Bluetooth SIG, Inc and any use of such marks by Keysight is under license. Other trademark and trade names are those of their respective owners. 2 Only applicable when connected to any dongle with Bluetooth Class 1 classification. 1 Product Characteristics Temperature Relative Humidity
(R.H.) Dimension (W x L x H) Weight Battery Type Battery Lifespan Power Consumption Warranty Bluetooth Compatibility Operating condition: 20 C to 55 C Storage condition: 40 C to 70 C Operating condition: Up to 80% at 40 C (non-condensing) Storage condition: Up to 95% at 40 C (non-condensing) 39.0 mm 71.0 mm 37.0 mm 60 g with batteries Lithium batteries: 30 hours Alkaline batteries: 20 hours Maximum 561 mVA for two 1.5 V AAA batteries Three months (Does not cover normal wear and tear of mechanical parts and batteries) Bluetooth SPP profile, Class 1 device, range up to 100 m Lithium 24LF (ANSI) and FR03 Alk Zinc Chloride 24 D (ANSI/NEDA) and R03 (IEC) aline 24 A (ANSI/NEDA) and LR03 (IEC)
(IEC) Keysight Handheld Meter/Display:
Keysight U1200 Series Handheld Meters Keysight U1115A Remote Logging Display Keysight PC Application Software:
Keysight Handheld Meter Logger Keysight Mobile Application:
Keysight Mobile Meter Keysight Mobile Logger Hardware Devices:
iPhone iPad iPod Touch Android smartphone/tablet Windows PC (with Bluetooth-enabled) 2 Regulatory Complies with IDA Standards DB 102425 The U1117A complies with the requirements of the following product standards:
EN 301 4891V1.9.2 EN 301 48917:V2.2.1 EN 55022:2010 EN55024:2010 Bluetooth) EN 300 328 V1.7.1 EMC RF (
RF (Health) Safety India E NER-ETA/923 EN 62311:2008 EN 609501:2006+A11:2009+A12:2011 quipment Type Approval (ETA) Certificate No:
This telecommunication equipment conforms to the NTC technical requirement Canada IC: The device contains transmitter IC: 5123ABGTWT11IA To comply with FCC and Industry Canada RF radiation exposure limits for general population, the antenna(s) used for this transmitter must be installed such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and all persons at all times and must not be colocated or operating in conjunction with any other antenna or transmitter. La operacin de este equipo est sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operacin no deseada. 3 Este produto est homologado pela Anatel, de acordo com os procedimentos regulamentados pela Resoluo n 242/2000 e atende aos requisitos tcnicos aplicados, incluindo os limites de exposio da Taxa de Absoro Especfica referente a campos eltricos, magnticos e eletromagnticos de radiofrequncia de acordo com as Resolues n 303/202 e 533/2009. Este equipamento opera em carter secundrio, isto , no tem direito a proteo contra interferncia prejucidial, mesmo de estaes do mesmo tipo, e no pode causar interferncia a sistemas operando em carater primrio. Manter distncia mnima de 10 cm do corpo humano. Para maiores informaes, consulte o site da ANATEL www.anatel.gov.br The radio module certified by Japanese Radio Law is integrated inside. NCC Warning Statement:
Article 12 Without permission, any company, firm or user shall not alter the frequency, increase the power, or change the characteristics and functions of the original design of the certified lower power frequency electric machinery. Article 14 The application of low power frequency electric machineries shall not affect the navigation safety nor interfere a legal communication, if an interference is found, the service will be suspended until improvement is made and the interference no longer exists. 4 According to FCC part 15:21, changes or modifications not expressly approved by the manufacturer for compliance could void the users au-
thority to operate the equipment. According to FCC part 15.105(b):
This equipment has been tested and found to comply with the lim-
its for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accoradance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 5 Front View LED Indicator and Slide Switch Low battery LED red flashing 1. Bluetooth disconnected LED green flashing 2. Bluetooth connected LED solid green 3. Bluetooth power off LED off Slide switch Operation Do not open the plastic case unnecessarily. Doing so may cause damage to the plastic case. K eep the adapter away from getting wet. Ensu re the adapter is turned OFF and the battery cover is removed when replacing the batteries. The b atteries must be recycled or disposed properly after depletion. f the LED is not lighted when turned on, replace the batteries with I new specified batteries. T he adapter can only be used with Keysight handheld meters. Install and Replace the Batteries Make sure you turn off the U1117A before installing or replacing the batteries. ays remove dead batteries immediately. To avoid the U1117A being damage from battery leakage:
A Alw lways remove the batteries and store them seperately if the adapter is not going to be used for a long period. 6 1. Slide the battery cover away from adapters body. 2. Insert the batteries. 3. Reverse the sliding position to close the battery cover. Turn On the U1117A Set the slide switch to On. Configure the U1117A The U1117A is designed to be used straight from the box without any configuration. How-
ever, if your hardware requires special configuration, you may setup the U1117A using the U1117A Configuration Utility downloadable at www.keysight.com/find/U1117A Set the slide switch to Setup. 7 Reset the U1117A 1. Open the battery cover. Then, set the slide switch to Setup. 2. Use a flat-blade screwdriver to push the button located in the hole for around three seconds. Connect Your U1117A Adapter to the Keysight Handheld Meter Snap the optic side of the U1117A to the handheld meters IR communication port. 8 Install the U1117A to PC via Bluetooth Before you begin, make sure the is enabled. It is operations that are critical or require a longer duration. In so ports. Use the COM port with the Outgoing label only. Bluetooth connection on your PC recommended to use brand new batteries before running any me cases, the Bluetooth Device Manager will create two COM 1. Set the U1117A slide switch to On. 2. From your PC (Windows 7), go to Start > Devices and Printers. 3. Click Add a device. 4. Select Keysight U1117A-XXXXXXthe XXXXXX represents U1117A device ID and click Next. 5. Type the default Bluetooth pairing code 1234 and click Next. 6. Once pairing is successful, a notification window will appear. Click Close. 7. The U1117A-XXXXXX is now added and connected successfully to your PC. Connect a Meter to the Keysight Handheld Meter Logger via the U1117A Before you begin, make sure you download the Keysight Handheld Meter Logger at www.keysight.com/find/hhmeterlogger 1. Open the Keysight Handheld Meter Logger. 2. On the Connected Instruments List (at the bottom), select the U1117A-XXXXX and click Connect to establish the multimeter connection. 3. The multimeter will remain connected until the connection is disconnected or the U1117A is turned off. Only one host computer is able to conne ct to the U1117A at a time. Connect a Meter to the Keysight U1115A Remote Logging Display via the U1117A For details, refer to the U1115A Remote Logging Display Operating Instructions at www.keysight.com/find/U1115A. 9 Connect a Meter Remotely via the Keysight Mobile Application
(Keysight Mobile Apps) You can now turn your Android and iOS devices into a remote measurement, control and reporting devices using both the Keysight Mobile Meter and Keysight Mobile Logger available on the Google Play and App Store. These Mobile Apps allow you to wirelessly control your Keysight handheld meter with your Android devices and iOS devices via the Keysight U1117A adapter. All Keysight handheld meters are supported, with the exception of the Keysight U1240 Se-
ries, which requires an additional Keysight U1179A IR Connectivity Bracket for compability with the Keysight U1117A adapter. Visit the URLs below for more information on the Keysight Mobile Apps:
Android devices http://play.google.com/store/apps/details?id=com.keysight.mobilemeter http://play.google.com/store/apps/details?id=com.keysight.mobilemeterlogger iOS devices https://itunes.apple.com/us/app/keysight-mobile-meter/id675491562?ls=1&mt=8 https://itunes.apple.com/us/app/keysight-mobile-logger/id675497444?ls=1&mt=8 Maintenance If any part of the adapter is worn out or damaged, replace it with a new U1117A adapter. Assistance For technical assistance, contact your nearest Keysight Sales Office or visit the Keysight website at www.keysight.com/find/assist for further information. U1117-90103 Keysight Technologies, Inc., 2014 Printed in Malaysia October 31, 2014 1852-14-7510
(01) 07898994220626 10