KINETICO SYSTEMHUB USER MANUAL Kinetico SysHub COPYRIGHT INFO The information contained in this document is the proprietary information of Kinetico Industries, Inc., Ltd. The contents are confidential and any disclosure to persons other than the officers, employees, agents or subcontractors of the owner or licensee of this document, without the prior written consent of Kinetico, is strictly prohibited. Further, no portion of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, without the prior written consent of Kinetico, the copyright holder. Kinetico publishes this document without making any warranty as to the content contained herein. Further Kinetico reserves the right to make modifications, additions and deletions to this document due to typographical errors, inaccurate information, or improvements to reference design platforms or products mentioned in the document at any time and without notice. Such changes will, nevertheless be incorporated into new editions of this document. November 23, 2018 Copyright 2018 Kinetico Page | 2 Kinetico SysHub TABLE OF CONTENTS 1 REVISION HISTORY .............................................................................................................................................. 6 1.1 REVISION HISTORY .................................................................................................................................................... 6 1.2 REFERENCES ............................................................................................................................................................ 6 2 USING THIS MANUAL .......................................................................................................................................... 7 2.1 PURPOSE AND AUDIENCE ........................................................................................................................................... 7 2.2 SUMMARY OF CHAPTERS ............................................................................................................................................ 7 3 OVERVIEW .......................................................................................................................................................... 8 3.1 KINETICO COMPONENTS ............................................................................................................................................ 8 3.2 KINETICO SYSHUB BLOCK DIAGRAM ............................................................................................................................. 9 3.3 KINETICO SYSHUB - SPECIFICATIONS AND FEATURES ........................................................................................................ 9 3.4 PROTOCOL & SECURITY SUPPORT .............................................................................................................................. 10 3.5 WI-FI ADDRESSES AND PORT NUMBERS ..................................................................................................................... 10 3.5.1 Hardware Address ...................................................................................................................................... 10 3.5.2 Port Numbers ............................................................................................................................................. 10 3.6 KINETICO SYSHUB INFORMATION LABEL ...................................................................................................................... 11 4 THE KINETICO SYSHUB USER INTERFACES ......................................................................................................... 12 4.1 POWER SUPPLY ...................................................................................................................................................... 12 4.2 WI-FI ................................................................................................................................................................... 13 4.3 ZIGBEE ................................................................................................................................................................. 14 4.4 USER INTERFACE SWITCH ......................................................................................................................................... 15 4.5 USER LED INDICATIONS ........................................................................................................................................... 15 5 INSTALLATION OF KINETICO SYSHUB ................................................................................................................ 17 5.1 KINETICO SYSHUB BOX CONTENT .............................................................................................................................. 17 5.2 USER REQUIRED ITEMS ............................................................................................................................................ 17 6 MOBILE APPLICATION SETUP OF KINETICO SYSHUB .......................................................................................... 18 7 CONTACT US AND SUPPORT ........................................................................... ERROR! BOOKMARK NOT DEFINED. 8 APPENDIX-A ...................................................................................................................................................... 19 8.1 ACRONYMS & GLOSSARY ......................................................................................................................................... 19 9 APPENDIX-B ...................................................................................................................................................... 20 9.1 COMPLIANCE ......................................................................................................................................................... 20 FCC STATEMENT .................................................................................................................................................. 21 RF RADIATION EXPOSURE STATEMENT ................................................................................................................ 21 IC STATEMENT ..................................................................................................................................................... 21 November 23, 2018 Copyright 2018 Kinetico Page | 3 Kinetico SysHub LIST OF FIGURES Figure 1 - Kinetico SysHub Block Diagram ........................................................................................... 9 Figure 2 - Product Label-1 inside battery holder ............................................................................... 11 Figure 3 - Serial Number Label-2 on the bottom side of enclosure ..................................................... 11 Figure 4 - User interaction Block Diagram ......................................................................................... 12 Figure 5 - Power supply adapter ....................................................................................................... 13 Figure 6 - Li-ion battery compartment and placement with polarity................................................... 13 November 23, 2018 Copyright 2018 Kinetico Page | 4 Kinetico SysHub LIST OF TABLES Table 1 - Revision History .................................................................................................................. 6 Table 2 References ......................................................................................................................... 6 Table 3 - References .......................................................................................................................... 7 Table 4 - Kinetico SysHub specifications ........................................................................................... 10 Table 5 - User LED Indications .......................................................................................................... 16 Table 6 - Kinetico SysHub Box Content ............................................................................................. 17 Table 7 - Other Require Equipment .................................................................................................. 17 Table 8 - Acronyms & Glossary ........................................................................................................ 19 November 23, 2018 Copyright 2018 Kinetico Page | 5 Kinetico SysHub 1 REVISION HISTORY 1.1 Revision History Rev. 1.0 Date 05-Nov-18 1.2 References Documents Description Prepared By Reviewed By Approved By Initial draft version released Kinetico Kinetico Table 1 - Revision History Revision Table 2 References November 23, 2018 Copyright 2018 Kinetico Page | 6 Kinetico SysHub 2 USING THIS MANUAL 2.1 Purpose and Audience This document provides Introduction, key features, design platform Architecture and interfaces, setup and use of Kinetico SysHub. It is intended for the users who are configuring this product. The user need to use this product to protects your home or building from water damage 24/7 with smart home technology that detects water leaks, alerts the home owner, and shuts off the main water supply automatically to prevent any further damageeven if disaster strikes and Internet is down. 2.2 Summary of chapters Chapter No. 3 Overview Chapter Description Describes Introduction, block diagram, Specifications, key features and the protocols it supports. Includes technical specifications. Describes Hardware interface idea and wireless technology support details. Describe details of List of content in box of product and how to install it on field Describes setup and configuration procedure with Wi-Fi using mobile application. Instructions for contacting Kinetico and Technical Support details Acronyms and Glossary Full forms of used short names Design Architecture and Interfaces Installation of SysHub Setup of SysHub Contact us and support Appendix A Appendix B SysHub compliance details Table 3 - References 4 5 6 7 8 9 November 23, 2018 Copyright 2018 Kinetico Page | 7 Kinetico SysHub 3 OVERVIEW The Kinetico SysHub is a smart, customize, advance Product for next generation water leakage detection and damage prevention system with the help of leak detect sensor in Internet of Things. It also automatically shuts off the water as soon as a leak is detected during sensor is configured in Protect Mode. It is targeted for multiple use cases in various segments of IoT such as Smart Home and Buildings. The Kinetico SysHub is designed with core features like ZigBee and Wi-Fi Connectivity. Connect SysHub monitors the home 24/7 for water leaks to help avoid water damage. Protect The system can immediately detect both leaking water and dropping temperatures using water leak sensors. The water alarm sensor will alert the system to automatically shut off the home's water supply when a water leak is detected. Trust Your homes water is shut off as soon as a leak is detected. Plus, you can remotely control your main water valve from anywhere. 3.1 Components Kinetico Hub - If a water leak is detected in your home, the SysHub receives the signals from the leak sensors placed in your home and directs the Valve to immediately shut off your homes water supply to eliminate the threat of water damage. Kinetico App A new version of app that shall deliver instant notification when a leak is detected in your home that your water is subsequently shut off. Additionally, it shall alert you on your smart device if certain temperatures are reached or if sensor batteries are running low. Kinetico Cloud - Kinetico Cloud shall be based on Ayla Cloud which is a completely managed service that provides a full suite of operational, business intelligence, and analytics services to manage a cloud connected deployment throughout its life-cycle. November 23, 2018 Copyright 2018 Kinetico Page | 8 Kinetico SysHub 3.2 Kinetico SysHub Block Diagram Kinetico SysHub is one of the component of Kinetico System which is a Full Home Water Leak Detection System. Kinetico is the customized hub for their next generation of leak detection and prevention system. Figure 1 - Kinetico SysHub Block Diagram 3.3 Kinetico SysHub - Specifications and Features Hub Kit Content Power Adapter Primary supply Secondary supply Backup on secondary supply Battery Wi-Fi ZigBee Antenna diversity 1. Hub with battery pre-installed 2. Power adapter 3. Quick start guide Input of Power Adapter: 100-240V AC / 50-60Hz Output of Power Adapter: 5V DC, 1A Type: Wall plug mount Pin standard: NEMA 1-15P (two-pole, no ground) Through AC/DC power adapter Built-in, field replaceable Li-Po battery pack Uninterrupted switching to secondary supply in absence of primary supply. Up to 3.5 hours continuous operation of the product. Li-Po battery (18350 cell)- 3.7V, 850mAh 802.11 b/g/n, WPA-PSK, WEP, PCB Trace Antenna, Wi-Fi compliant 802.15.4 (2.4 GHz) Support for ZigBee Antenna 1: PCB trace antenna November 23, 2018 Copyright 2018 Kinetico Page | 9 Kinetico SysHub Antenna 2: Chip antenna Flash 8MB Operation Buttons Status Indicator 1x User input (Wi-Fi Provisioning) 1x Factory reset 1x Power On/Off 1x RGB LED Operating System FreeRTOS Certification:
Operating Temperature Storage Temperature FCC, IC 0C to 45C
-20C to 45C (Driven by battery specifications) Operating Humidity 10%~90%RH (Non-condensing) Storage Humidity 10%~90%RH (Non-condensing) Enclosure Dimensions (in mm) Weight (in g) 92 x 35 x 90 mm (L x W X H) 90gram Table 4 - Kinetico SysHub specifications Note: The Primary source of power is Adapter and battery is only used for backup when primary source is not present. 3.4 Protocol & Security Support The SysHub contains a full-featured wireless software stack:
AP and Station Mode for Wi-Fi ZigBee WPA/WPA2 Personal 3.5 Wi-Fi Addresses and Port Numbers 3.5.1 Hardware Address The hardware address of Wi-Fi is also referred to as the physical address, or MAC address. Sample ways hardware address may be represented:
00-80-A3-14-1B-18 00:80: A3:14:1B:18 3.5.2 Port Numbers Every TCP connection is defined by a destination and source IP Address, and a destination and source port number. For example, a Telnet server commonly uses TCP port number 23. The following is a list of the default server port numbers running on the Kinetico SysHub:
TCP Port 443: HTTPS (Web Manager Configuration) TCP Port 80: HTTP (Web Manager Configuration) November 23, 2018 Copyright 2018 Kinetico Page | 10 Kinetico SysHub 3.6 Kinetico SysHub information Label The Kinetico SysHub information Label on the device contains the following information about the specific unit:
Label-1 Company logo Model Name Serial Number MAC Address Wi-Fi module FCC ID Wi-Fi module IC ID FCC ID IC ID e.g.:
Figure 2 - Product Label-1 inside battery holder Label-2 Company logo Serial Number Wi-Fi MAC Address QR Code with Serial Number and Wi-Fi MAC Address details e.g.:
Figure 3 Serial Number Label-2 on the bottom side of enclosure November 23, 2018 Copyright 2018 Kinetico Page | 11 Kinetico SysHub 4 THE KINETICO SYSHUB USER INTERFACES The Kinetico SysHub implements an advanced next generation wireless interfaces like Wi-Fi and ZigBee. This section provides information about different user interactions of SysHub. The basic user interaction diagram is shown as per below image:
Figure 4 User interaction Block Diagram The above diagram has following main Sections:
1. Power Section - Power supply and Battery Protection, Battery Charging and Switching Circuit 2. Wi-Fi 3. ZigBee 4. User Interface Switch 5. Status Indication RGB LED 4.1 Power Supply The Kinetico board power is supplied by two sources:
1. Primary Supply (Power Adapter): It is the main power source of Kinetico SysHub. The output of power supply adapter is 5V, 1A power Adapter. November 23, 2018 Copyright 2018 Kinetico Page | 12 Kinetico SysHub Figure 5 - Power supply adapter 2. Secondary Supply (Li-ion battery): It supports 3.8 to 4.2V range and it is used for battery backup and supply power if power adapter is not used. Figure 6 Li-ion battery compartment and placement with polarity Note: User must initially supply power through power adapter once and then it can switch supply power through battery. 4.2 Wi-Fi Kinetico SysHub support of Single Band (2.4GHz) Wi-Fi Module. This module is FCC/CE/IC/NCC Certified. The SysHub supports following features:
Wi-Fi Micro-Controller Smart Energy Platform Solution I/O Interface Support: UART, JTAG, GPIO, SSP, I2C and GPT Support of IEEE 802.11b/g/n Wi-Fi November 23, 2018 Copyright 2018 Kinetico Page | 13 Kinetico SysHub Integrated Printed- Antenna LGA package 4.3 ZigBee ZigBee:
The ZigBee SoC is an ultra-low power, high performance wireless chip. It supports following features:
2.4GHz IEEE802.15.4 compliant TX power 8.5 dBm/10 dBm & with PA up to max. 20dBm Receiver sensitivity 96 dBm TX current 24 mA at 10 dBm TX current 21.2 mA at 8.5 dBm RX current 14.3 mA at maximum input level 2 dBm 3.3 V operation Support with both Chip and PCB Antenna Power Amplifier Module The power amplifier module is a high-performance, fully integrated RF front-end module (FEM) designed for ZigBee applications. Integrated PA with up to +21 dBm output power Integrated LNA (2 dB noise figure typical) and bypass path Integrated antenna diversity switching for all modes Single-ended transmit/receive interface Fast switch on/off time: < 800 ns Supply range: 1.8 V to 3.6 V Sleep mode current: < 1 A typical No external bias resistor is required Antenna Diversity support November 23, 2018 Copyright 2018 Kinetico Page | 14 Kinetico SysHub 4.4 User Interface Switch The Kinetico has three below user interaction switch:
Figure 9 SysHub switch details 1. Wi-Fi Provisioning Button: Use to put Wi-Fi in provision mode and press for 5 seconds to reset Wi-Fi credentials. 2. Factory Reset: To reset the SysHub by 15-second-long press. It is also used to reboot the system without removing power supply. Pressing the switch will drive logic zero on RESET signal, which will affect every module on SysHub. 3. Power ON/OFF Switch: To ON and OFF the power of Kinetico SysHub. 4.5 User LED Indications Single RGB LED is used to provide indication about different SysHub functionality. Below table indicates color mark to represent specific events. LED indication Primary Supply Secondary Supply Red No Wi-Fi Connection No Wi-Fi Connection Red Blinking No Internet Access No Internet Access Blue System is OK NA November 23, 2018 Copyright 2018 Kinetico Page | 15 Kinetico SysHub Green Blinking Initializing Pairing Mode Initializing Pairing Mode Green Firmware upgrade in progress Firmware upgrade in progress Yellow-Orange NA System is OK, running on battery Yellow-Orange Blinking NA LOW Battery Light Purple Factory Reset in progress Factory Reset in progress Red and Blue blinking Abnormal Condition Abnormal Condition Table 5 - User LED Indications Figure 10 SysHub user interaction LED November 23, 2018 Copyright 2018 Kinetico Page | 16 Kinetico SysHub INSTALLATION OF KINETICO SYSHUB 5 The Kinetico SysHub comes with its required contents and it is mentioned in below section. 5.1 Kinetico SysHub Box Content The Kinetico SysHub comes with following listed items:
Item Description SysHub SysHub unit with 18350 Li-ion battery Power Adapter DC 5V, 1A Documentation Quick Start Guide Table 6 - Kinetico SysHub Box Content 5.2 User required Items To complete your demo installation, you need following items and it is not standard parts of Kinetico SysHub. User needs to manage it. Item Description Internet connectivity To connect SysHub to cloud over Wi-Fi Mobile Device
(Android/iOS) To access application and function the SysHub Mobile Application Mobile Application (Support on Android and/or iOS) Table 7 - Other Require Equipment Warning: User needs to keep the product at least 20 cm away from the body when it is in working condition. November 23, 2018 Copyright 2018 Kinetico Page | 17 Kinetico SysHub 6 MOBILE APPLICATION SETUP OF KINETICO SYSHUB Kindly refer Kinetico SysHub User Guide_v1.1 for setup and configuration of Mobile application on Android and/or iOS platform. November 23, 2018 Copyright 2018 Kinetico Page | 18 Kinetico SysHub 7 APPENDIX-A 7.1 Acronyms & Glossary The following terms are used in this document Sr No#
Terms Definition SDRAM Synchronous Dynamic Random-Access Memory 1. 2. 3. 4. 5. 6. 7. 8. 9. GPIO I2C IoT JTAG LDO LED PA SoC 10. LNA 11. 12. 13. 14. 15. SPI TBD U. FL UART USB General Purpose Input and Output Inter Integrated Circuit Internet of Things Joint Test Action Group Low Dropout Light Emitting Diode Power Amplifier System on Chip Low Noise Amplifier Serial Peripheral Interface To Be Define Ultra-Miniature RF Connector Universal Asynchronous receiver and Transmitter Universal Serial Bus Table 8 - Acronyms & Glossary November 23, 2018 Copyright 2018 Kinetico Page | 19 Kinetico SysHub 8 APPENDIX-B 8.1 Compliance Design Platform Name Model:
Kinetico SysHub Conforms to the following standards or other normative documents:
FCC: FCC part 15 modular certification ID: 2ARJL KNTSYSHUB3 IC: Industry Canada RSS-247 modular certification IC: 24464- KNTSYSHUB3 November 23, 2018 Copyright 2018 Kinetico Page | 20 Kinetico SysHub FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used interference to radio communications. However, there is no guarantee that interference will not occur in an installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. instructions, may cause harmful in accordance with the RF Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body IC Statement This device complies with Industry Canada licenseexempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. This device complies with RSS247 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference. This Class B digital apparatus complies with Canadian ICES003 (Cet appareil numrique de la Classe B conforme la norme NMB003 du Canada). November 23, 2018 Copyright 2018 Kinetico Page | 21 Kinetico SysHub 24464-KNTSYSHUB3 This equipment (IC: _______________) complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. 24464-KNTSYSHUB3 Cet quipement (IC: ________________) est conforme aux limites IC d'exposition aux radiations dfinies pour un environnement non contrl. Cet quipement doit tre install et utilis avec une distance minimale de 20 cm entre le radiateur et votre corps. Cet metteur ne doit pas tre situ ou oprant en conjonction avec une autre antenne ou metteur. November 23, 2018 Copyright 2018 Kinetico Page | 22