93089911_A P2578 Limited Lifetime Warranty Progress Lighting fan motors are warranted to the original purchaser to be free of electrical and/or mechanical defects for so long as the original purchaser owns the fan. Pull chain switches, reverse switches, capacitors and metal finishes are warranted to be free from defects in materials or workmanship for a period of 1 year from the date of purchase. Warping of wooden or plastic blades is not covered by this warranty nor is corrosion and/
or deterioration of any finishes for fans installed within ten miles of any sea coast. Extended warranties for ENERGY STAR qualified products may apply. Progress Lighting ceiling fans with built-in LED light sources, when properly installed and under normal conditions of use, are warranted to be free from defects in material and workmanship which cause the light sources to fail to operate in accordance with the specifications for (i) five (5) years from the date of purchase on the LED Light modules and electrical components for fans used in single family residences, and (ii) three
(3) years from the date of purchase on the LED Light modules and electrical components for fans used in multi-family or commercial applications. LED bulbs supplied by Progress Lighting carry no warranty other than manufacturers warranty. Non-LED bulbs carry no warranty. With proof of purchase, the original purchaser may return the defective fan to the place of purchase during the first 30 days for replacement. After 30 days, the original purchaser MUST contact Progress Lighting at (864) 678-1000 for repair or replacement which shall be determined in Progress Lightings sole discretion and shall be purchasers sole and exclusive remedy. Labor and Shipping Excluded. This warranty does not cover any costs or fees associated with the labor
(including, but not limited to, electricians fees) required to install, remove, or replace a fan or any fan parts. This warranty shall not apply to any loss or damage resulting from (i) normal wear and tear or alteration, misuse, abuse or neglect, or (ii) improper installation, operation, repair or maintenance by original purchaser or a third party, including without limitation improper voltage supply or power surge, use of improper parts or accessories, unauthorized repair (made or attempted) or failure to provide maintenance to the fan. THE FOREGOING WARRANTIES STATE PROGRESS LIGHTINGS ENTIRE WARRANTY OBLIGATION AND ORIGINAL PURCHASERS SOLE AND EXCLUSIVE REMEDY RELATED TO SUCH PRODUCTS. PROGRESS LIGHTING IS NOT RESPONSIBLE FOR DAMAGES (INCLUDING INDIRECT, SPECIAL, INCIDENTIAL OR CONSEQUENTIAL), DUE TO PRODUCT FAILURE, WHETHER ARISING OUT OF BREACH OF WARRANTY, BREACH OF CONTRACT, OR OTHERWISE. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED, INCLUDING THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitations of incidental or consequential damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific rights and you may have other rights which vary from state to state. Date Purchased Store Purchased UL Model No. P2578 Serial No. Vendor No. 111017 UPC Safety Rules Unpacking Your Fan Installing Your Fan Making the Electrical Connections Operating Your Fan Care of Your Fan Troubleshooting Specifications 1 2 3 6 9 10 10 11 Table of Contents READ AND SAVE THESE INSTRUCTIONS 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National Electrical Code ANSI/NFPA 70-1999 and local electrical codes. Electrical installation should be performed by a qualified licensed electrician. 3. CAUTION: To reduce the risk of personal injury, use only 4. The outlet box and support structure must be securely the screws provided with the electrical box. mounted and capable of reliably supporting 35 lbs. (15.9 kg). Use only UL Listed outlet boxes marked Acceptable for Fan Support of 35 lbs. (15.9 kg) or less. 5. CAUTION: The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor. 6. Do not operate reversing switch while fan blades are in motion. Fan must be turned off and blades stopped before reversing blade direction. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT OF 35LBS. (15.9 KG) OR LESS, AND USE SCREWS PRO-
VIDED WITH THE OUTLET BOX. TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE BLADE BRACKETS (ALSO REFERRED TO AS (FLANGES) DURING ASSEMBLY OR AFTER INSTALLATION. DO NOT INSERT OBJECTS IN THE PATH OF THE BLADES. 1. Safety Rules 7. Avoid placing objects in path of the blades. 8. To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan. 9. Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for most cleaning. 10. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into electrical box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the electrical box and ungrounded conductor on the other side of the electrical box. 11. Electrical diagrams are for reference only. Light kits that are not packed with the fan must be UL Listed and marked suitable for use with the model fan you are installing. Switches must be UL General Use Switches. Refer to the instructions packaged with the light kits and switches for proper assembly. 12. All set screws must be checked and retightened where necessary before installation. 13. WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. 14. Use With Speed Controller UC7067RYE, manufactured by Rhine Electronic Co., Ltd only. TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH AN ISOLATION CONTROL/SWITCH. 1 2 3 4 5 6 7 8 9 10 11 Unpack your fan and check the contents. You should have the following items:
a c b d 1. Mounting Bracket (inside canopy) 2. 4.5 Ball/Downrod Assembly (hanger pin and locking pin pre-attached) 3. Canopy with Canopy Ring (attached) 4. Decorative Motor Collar Cover 5. Fan Motor Assembly 6. Blade Bracket (5) 7. Blades (5) 8. Light Kit Pan 9. Light Kit Fitter Assembly 10. Glass Shade 11. Transmitter and Receiver a. Blade attachment hardware b. Electrical hardware and Balancing kit
(15 Screws)
(3 plastic wire connectors, blade balancing kit) c. Blade bracket hardware (11 Screws) d. Blade decorative hardware (15 Screws) 2. Unpacking Your Fan Figures 1, 2, and 3 are examples of different ways to mount the electrical box. Tools Required Phillips screw driver or straight slotted screw driver, adjustable wrench, step ladder, and wire cutters. Mounting Options If there isnt an existing electrical box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers. Secure the electrical box directly to the building structure. Use appropriate fasteners and building materials. The electrical box and its support must be able to fully support the moving weight of the fan (at least 35 lbs.). Do not use plastic electrical boxes. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT OF 35LBS. (15.9 KG) OR LESS, AND USE SCREWS PROVIDED WITH THE OUTLET BOX. ELECTRICAL BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES MAY NOT BE ACCEPT-
ABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELEC-
TRICIAN IF IN DOUBT. 3. Installing Your Fan Figure 3 Note: You may need a longer downrod to maintain proper blade clearance when installing on a steep, sloped ceiling. The maximum angle allowable is 20. If the canopy touches downrod, remove the decorative canopy bottom cover and turn the canopy 180 before attaching the canopy to the mounting plate. Figure 1 Figure 4 To hang your fan where there is an existing fixture but no ceiling joist, you may need an installation hanger bar as shown in Figure 4. Figure 2 Hanging the Fan REMEMBER to turn off the power. Follow the steps below to hang your fan properly. NOTE: This fan is recommended for standard ceiling mount using the downrod provided with this fan. When using standard ceiling installation with the 4.5 inch downrod provided, the distance from the ceiling to the bottom of the fan blades will be approximately 10 inches. Standard Ceiling Mounting 1. Remove the canopy ring from the canopy by turning the ring counter-clockwise until it unlocks. (Figure 5) 2. Remove the mounting bracket from the canopy by loosening the four screws on the top of the canopy. Remove the two non-slotted screws and loosen the slotted screws. This will enable you to remove the mounting bracket. (Figure 6) 3. Remove the hanger pin and locking pin from downrod assembly 4. Route the wires exiting the top of the fan motor through the decorative motor collar cover then the canopy ring. Make sure the slot openings are on top. Route the wires through the canopy and then through the ball/downrod assembly. (Figure 7) Turn Canopy to Remove 7. Re-tighten the set screws on the collar on top of the motor housing. 8. Make sure the grommet is properly installed in the collar cover, then slide the collar cover on the downrod until it rests on the motor housing. Be sure that the canopy and the collar cover are both oriented correctly. 9. Proceed to Installing the Fan section. Figure 5 Loosen but Do Not Remove Remove FAILURE TO PROPERLY INSTALL SET SCREWS AS NOTED IN STEP 7 COULD RESULT IN FAN LOOSENING AND POSSIBLY FALLING. Motor wires Figure 6 5. Loosen, but do not remove, the set screws on the collar on the top of the motor housing. 6. Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing. (Figure 7) Carefully insert the hanger pin through the holes in the collar and downrod. Be careful not to jam the hanger pin against the wiring inside the downrod. Insert the locking pin through the hole near the end of the bolt until it snaps into its locked position, as noted in the circle inset of Figure 7. Ball/Downrod assembly Canopy Canopy ring Motor collar cover Hanger pin Motor collar Pin in locked position Locking pin Tighten screws Figure 7 4. Reverse switch Installing Fan to the Electrical Box WHEN MOUNTING THE FAN ON A SLOPED CEILING, THE STANDARD BALL/DOWNROD MOUNTING METHOD MUST BE USED. THE MOUNTING BRACKET MUST BE MOUNTED SO THAT THE SLOT OPENINGS ARE ON THE LOWER SIDE BY SLIDING THE MOUNTING BRACKET FROM THE TOP DOWN. 1. Pass the 120-volt supply wires through the center hole in the ceiling mounting bracket as shown in Figure 8. 2. Install the ceiling mounting bracket on the electrical box by using the mounting screws provided with the electrical box. Note that the flat side of the mounting bracket is toward the electrical box. (Figure 8) 3. Tighten the two screws on the electrical box securely. 4. Carefully lift the fan assembly up to the ceiling mounting bracket. Make sure the tab on the mounting bracket is properly seated in the groove in the hanger ball. (Figure 9) WHEN USING THE STANDARD BALL/DOWNROD MOUNTING, THE TAB IN THE RING AT THE BOTTOM OF THE MOUNTING BRACKET MUST REST IN THE GROOVE OF THE HANGER BALL. FAILURE TO PROPERLY SEAT THE TAB IN THE GROOVE COULD CAUSE DAMAGE TO WIRING. 5. Figure 8 Standard mounting Figure 9 Making the Electrical Connections REMEMBER to disconnect the power. If you feel you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. Follow the steps below to connect the fan to your household wiring. Use the wire connecting nuts supplied with your fan and supplied with remote control. Secure the connectors with electrical tape. Make sure there are no loose strands or connections. (Figure 10) 1. Connect the ground conductor of the 120v supply (this may be a bare wire or a wire with green colored insulation) to the green ground lead(s) of the fan. (Figure 10) 2. Connect the fan motor white wire to the receiver white wire using a wire nut.
(Figure 10) 3. Connect the fan motor black wire to the receiver black wire using a wire nut.
(Figure 10) 4. Connect the fan motor blue wire to the receiver blue wire using a wire nut. t(Figure 10) 5. Connect the receiver black wire to the supply black (hot) wire using a wire nut.
(Figure 10) 6. Connect the receiver white wire to the supply white (neutral) wire using a wire nut. (Figure 10) 7. After connecting the wires, spread them apart so that the green and white wires are one side of the electrical box and the black wire is on the other side. 8. Turn the wire connecting nuts upward and carefully push the wiring into the electrical box. SUPPLY CIRCUIT K C A L B I E T H W Remote Receiver K C A L B E U L B I E T H W N E E R G Grounding Conductor Green Grounding Lead USE THE PLASTIC WIRE CONNECTORS SUPPLIED WITH YOUR FAN. SECURE THE CONNECTORS WITH ELECTRICAL TAPE AND ENSURE THERE ARE NO LOOSE STRANDS OR CONNECTIONS. EACH WIRE NUT (WIRE CONNECTOR) SUPPLIED WITH THIS FAN IS DESIGNED TO ACCEPT UP TO ONE 12 GAUGE HOUSE WIRE AND TWO WIRES FROM THIS FAN. IF YOU HAVE LARGER THAN 12 GAUGE HOUSE WIRING OR MORE THAN ONE HOUSE WIRE TO CONNECT TO THE FAN WIRING, CONSULT AN ELECTRICIAN FOR THE PROPER SIZE WIRE NUTS TO USE. BLUE BLACK WHITE WHITE Figure 10 6. Attaching the Light Kit Pan 1. Remove one screw from the black bracket below fan motor assembly, loosen but do not remove the other two screws. (Figure 11) 2. Push the light kit pan up to the fan motor assembly so that the two loosened screw heads fit into the keyhole slots. Turn the light kit pan clockwise. Re-install the screw that was removed in step 1. Make sure all the screws are firmly tightened. (Figure 11) Attaching the Fan Blades 1. Attach a blade to blade bracket using the decorative nuts and blade attachment screws provided. Insert a blade attachment screw through the hole in the blade bracket and blade and into the decorative nut. Tighten each screw securely. (Figure 12) 2. Repeat these steps for each blade and blade bracket. (Figure 12) 3. Attach the blade assemblies to the motor by aligning the two screw holes in the blade bracket with the screw holes in the center flywheel and secure with screws. (Figure 13) 4. Repeat this step for the remaining blade Motor Assembly Blade arm Screws Light Kit Pan Figure 11 Blade Screws Blade Balancing All blades are grouped by weight. Because natural woods vary in density, the fan may wobble even though the blades are weight matched. The following procedure should correct most fan wobble. Check after each step. 1. Check that all blade screws are secure. 2. Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the blades. Measure from a point on the center of each blade to the point on the ceiling. Measure this distance as shown in Figure 14. Rotate the fan until the next blade is positioned for measurement. Repeat for each blade. Measurements deviation should be within 1/8. Run the fan for 10 minutes. 3. Make sure that canopy is tightened securely to ceiling mounting bracket and that the ceiling mounting bracket is tightened securely to the electrical box. 4. Interchanging two adjacent blades can redistribute the weight and possibly result in the smoother operation. 5. Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable. Decorative Nuts Figure 12 Motor Assembly Screws Touching Ceiling Figure 13 Figure 14 assemblies. (Figure 13) 7. Assembling the Fan Finishing the Fan Installation 1. Align the locking slots of the ceiling canopy with the two screws in the mounting bracket. Push up to engage the slots and turn clockwise to lock in place. Immediately tighten the two mounting screws firmly. 2. Install the remaining two mounting screws into the holes in the canopy and tighten firmly. 3. Install the decorative canopy ring by aligning the rings slots with the screws in the canopy. Rotate the ring clockwise to lock in place. Installing the Light Kit Fitter Assembly/Glass Bowl CAUTION - To reduce the risk of electrical shock, disconnect the electrical supply circuit to the fan before installing the light kit. THE GLASS IS FRAGILE, USE CARE WHEN INSTALLING THE LIGHT KIT AND THE GLASS SHADE 1. Remove one screw from the light kit pan and loosen, but do not remove the other two screws. Connect the wires from the light kit fitter assembly to the wires from the fan motor assembly by connecting the molded adaptor plugs together. Carefully tuck all wires and splices into the switch cap. (Figure 15) 2. Push the light kit fitter assembly up so that the two loosened screw heads fit into the keyhole slots. Turn the light kit fitter assembly clockwise, tighten the screws. Re-install the screw that was removed in step 1 and tighten firmly. (Figure 15) 3. Remove the rubber gasket, nut and finial from the threaded nipple of the light kit fitter assembly. Position the glass bowl over the threaded nipple. Re-install the rubber gasket, nut and finial to the threaded nipple to secure the glass bowl properly. (Figure 16) NOTE DO NOT OVER TIGHTEN THE NUT. OVERTIGHTENING THE NUT MAY CAUSE THE GLASS TO BREAK. Blue Black White Light Kit Pan Light Kit Fitter Assembly Screws Figure 15 Nut Glass Shade Rubber washer Finial Figure 16 8. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans, and so on. The fan shipped from the factory with the reversing switch positioned to circulate air downward. If airflow is desired in the opposite direction, turn your fan off and wait for the blades to stop turning, then slide the reversing switch (located at the top of the motor housing, refer to figure 11 on page 5) to opposite position, and turn fan on again. The fan blades will turn in the opposite direction and reverse airflow. Warm weather - (Forward) A downward air flow creates a cooling effect as shown in Figure 17. This allows you to set your air conditioner on a higher setting without affecting your comfort. Cool weather - (Reverse) An upward air flow moves warm air off the ceiling are as shown in Figure 18. This allows you to set your heating unit on a lower setting without affecting your comfort. 9. Operating Your Fan Figure 17 Figure 18 Care of Your Fan to help you Here are some suggestions maintain your fan. 1. Because of the fans natural movement, some connections may become loose. Check the support connections, brackets, and blade attachments twice a year. Make sure they are secure. (It is not necessary to remove fan from ceiling.) 2. Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning, this could damage the motor, or the wood or possibly cause an electrical shock. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer to minimize discoloration or tarnishing. Warning - Make sure the power is off before cleaning your fan. 3. You can apply a light coat of furniture polish to the wood for additional protection and enhanced beauty. Cover small scratches with a light application of shoe polish. 4. There is no need to oil your fan. lubricated The motor has permanently sealed ball bearings. Troubleshooting Solution Problem 1. Check main and branch circuit fuses or breakers Fan will not start 2. Check line wire connections to the fan and switch wire connections in the switch housing. CAUTION: Make sure main power is off. 3. Check batteries in the transmitter. Does the red LED light come on?
Are you standing close enough to the fan? (Normal range is 10-20 feet.) Are the dip switch settings the same on the transmitter (hand unit) and receiver? REMEMBER TO TURN OFF POWER SUPPLY BEFORE CHECKING THE DIP SWITCH SETTINGS IN RECEIVER. Fan sounds noisy 1. Make sure all motor housing screws are snug. 2. Make sure the screws that attach the fan blade bracket to the motor hub 3. Make sure wire nut connections are not rattling against each other or are tight. the interior wall of the switch housing. CAUTION: Make sure power is off. 4. Allow a 24-hour breaking in period. Most noises associated with a new fan disappear during this time. 5. If using the Ceiling Fan light kit, make sure the screws securing the glassware are tight. Check that the light bulb is also secure. 6. Make sure the canopy is a short distance from the ceiling. It should not touch the ceiling. 7. Make sure your electrical box is secure and rubber isolator pads were used between the mounting bracket and electrical box. MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT TO MAKE ANY REPAIRS. REFER TO THE SECTION, MAKING ELECTRICAL CONNECTIONS. 10. Care of Your Fan and Troubleshooting FAN SIZE 52 SPEED VOLTS Low Med High 120 FAN POWER CONSUMPTION
(WITHOUT LIGHTS) WATTS xx xx xx AIRFLOW CFM xxxx xxxx xxxx AIRFLOW EFFICIENCY CFM/WATT
(HIGHER IS BETTER) xxx xxx xx NET WEIGHT GROSS WEIGHT CUBE FEET xx.xx Lbs xx.xx Lbs x.x This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help. CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 11. Specifications 2017 Progress Lighting, Inc. 701 Millennium Blvd., Greenville, SC 29607 All Rights Reserved