SE EM3000 0 Series s Opera ation M Manual Versio n 2.0 (M March 2, 2015 5) Usin ng a cross h ead or flat bladed screw wdriver, rem move the Sen nder Unit ba attery compa artment cov ver and inser rt 3C batt eries. Press t the RESET b button locate ed on the re ar of the Tra ansmitter Slide e the rear ba attery comp artment off the Display Unit. Insert 3 AA batter ies in the Di isplay Unit. 1)Pr ess and hold d the CHECK K key 5 seco onds on the rear of the C CRT3000 Tra nsmitter unt til the red LE ED flashes. If yo ou are using PIT3000 Tra ansmitter, pr ess [SET] bu utton at the f front side of f PIT3000 un ntil the red L LED flashes. 2)Ch heck the [CH HANNEL] ke ey located o n the botto om right han nd side of th he SEM3000 0 Display Un nit is showin ng. If not, Press [MEN NU] key to ch hange [SET]
-> [CHANN NEL]. Press a nd hold the
[CHANNEL]
] key 3 seco onds, Release e the
[CHA ANNEL] key on hearing a short bee p. see below s symbol NOW W ENERGY sc creen on Top pe left side. 3)No ow you can 4)Af fter synchron nization, the e screen dis play as belo ow: If your are using 9 99V, please change it w with [UP][DO OWN]
key. 5)Pr ess the [CHA ANGE] key o of Display un nit for to sto ore. The e radio wave e icon, in the e top left ha and corner o of the main s screen, will s show radio w wave power strength. The two units w will now con nect. Please note, this m may take up to 2 minute es. Once con nnected the radio wave icon in th he top left o of the screen n will be fully y illuminated d and a 0 w will be displa ayed in the main display y. You can positio on the Disp play Unit up p to 40 met ters away fr rom the CR RT3000 Trans smitter (sub bject to buil lding cons struction). YOU UR DISPLA AY UNIT H AS 6 SCR REEN WITH H 5 SECTIO ON. The top section shows Rad io Icon, Cha nnel numbe er (1-10), 4-
different Ala arm Display and Battery y power stre ength disp play for trans smitter and receiver eac h. 2nd s mar Add seco Top is 4-
section disp k. itionally it a onds. Addit left side sh
-step tiered lays Now En nergy with W Watt unit and d 1 Month e estimated Co ost with \, $
$, , , cur rrency symbo ol lso shows U tionally it als ows the ene tariff rate se Up, Down sym so shows the ergy billing m election 2 i mbol mark a e energy con method sele is special rat and the ener nsumption p ection from te tariff selec rgy increase percentage (
0 to 2. ction. and decrea
(%) vs month 0 is the sin se differenc hly target. ngle tariff ra e on every 1 12 ate selection
. 1 3rd s section show ws History d data like thi is day (toda ay), this wee ek, this mon nth and 1 m month (31da ays) accumu lated ener rgy consump ption in kWh h. The right hand side, it t shows the actual energ gy cost of it with curren cy symbol m mark. Und derneath of i t, it shows t oday graph and this we eek graph sim multaneously y. 4th s section show ws channel number, tim me, date, we eek, month and year d display. The e right han d side, it sh hows tem perature (C C. F) and CO O2 emission display. 5th section show ws touch k keys. . You w will hear a short beep p every time e you press s one of th e keys, [ME ENU], and [SET]. W We recomm mend you us se the sound d to help y you program m the
[CHA ANGE], [DOW WN], [UP],
[CHANNEL]
setti ings accurat ely. A. T IME/CLOCK:
[C1]
1)Pr ess and ho ld the [MEN NU] key unt til you hear r a beep. [S SET] icon wi ll appear in n bottom rig ght hand co orner inste ead of [CHA ANNEL]. 2)Pr ess [SET] key y 3 seconds and you co ould see belo ow symbol o on NOW EN ERGY:
3)Pr ess [SET] key y to see [F]
[YEAR] blink king. Press [
UP][DOWN]
key to adju ust the corre ect [YEAR] an nd press [SE T] to conf firm. 4)[M MINUTE] is b linking. Pres ss [UP][DOW WN] key to ad djust the co rrect [MINUT TE] and pres ss [SET] to co onfirm. 5)[H HOUR] is blin nking. Press
[UP][DOWN
] key to adju ust the corre ect [HOUR] a and press [S SET] to confir rm. 6)[D DAY] is blinki ng. Press [U P][DOWN] k key to adjust t the correct t [DAY] and press [SET] t to confirm. 7)[M MONTH] is b linking. Pres ss [UP][DOW WN] key to ad djust the adj just [MONTH H] and press s [SET] to co onfirm. 8)Pr ess [CHANG GE] key to sto ore. B. TA ARIFF SELEC TION: [C2]
1)Pr ess [MENU]
key for to c change [CHA ANNEL] -> [S SET]
2)Pr ess the [SET T] key 3 seco onds to see
[F] [C1] symb bol. Press [M MENU] key o once to chan nge [C1] >
[C2]. 3)Pr ess [SET] key y to see [F]
blinking to s see [0]. Pre ess [UP][DOW WN] key to s select [0] ->
[2] .
[0]:
: Single Rate e (Flat Rate),
, [1]: 4-step Tiered Rate,
, [2]: Time o of Use Rate f for all week(
(7 Day) [3] T Time of Use Rate for w weekdays +
weekend 4)Pr ess [CHANG GE] to go no rmal display y C. TARIFF RATE FOR SINGLE (FLAT) RATE: [C3]
1)Press [MENU] key for to change [CHANNEL] -> [SET]
2)Press the [SET] key 3 seconds to see [F] [C1] symbol. Press [MENU] key 2 times to change [C1] > [C3]. 3)Press [SET] key to see [F] blinking. Press [SET] key again to see Single (Flat) rate [$0.20] on COST screen. 4)Move cursor to proper position using [MENU] key. 5)Press [UP][DOWN] key to adjust the correct value. 6)Press [MENU] to move next position and adjust the correct value. Change all the correct value continuously. 7)Press [CHANGE] to store. D. TARIFF RATE FOR 4-STEP TIERED RATE: [C4]
TIER No. BASE BILLING TIER1
$0 TIER2 TIER3 THRESHOLD 0 ~ 1300kwh 1300~2300kwh 2300kwh over RATE
$0.10/kwh
$0.16/kwh
$0.24/kwh 1)Press [MENU] key for to change [CHANNEL] -> [SET]
2)Press the [SET] key 3 seconds to see [F] [C1] symbol. Press [MENU] key 3 times to change [C1] > [C4]. 3)Press [SET] key to see [F] blinking. Press [SET] key again to see 1-STEP Tiered rate [$0.10] on COST screen. 4)Move cursor to proper position using [MENU] key. 5)Press [UP][DOWN] key to adjust the correct value. 6)Press [MENU] to move next position and adjust the correct value. Change all the correct value continuously. 7)Press [SET] to see 1-THRESHOLD Range [1300KWh]. 8)Press [MENU] to move next position. And adjust the correct value Change all the value continuously. 9)Press [MENU] key to see [F] [1300kWh] blinking. Press [UP] key to change the [Tier 2] and you can see [2300 KWh]. 10)You can see [$0.16] If it is okay, press [UP] key to see [$0.24] If it is okay, press [SET] key to see [00000 KWh]
11)Press change to store. E. SET TARIFF TIME OF USE WEEK BILLING RATE: [C5]
OFF PEAK MID PEAK ON PEAK
. BILLING RATE
$0.10/KWh
$0.16/KWh
$0.24/KWh WEEK DAYS WEEK ENDS MO ~ FR SUNDAY, SATURDAY 1)Press [MENU] key for to change [CHANNEL] -> [SET]
2)Press the [SET] key 3 seconds to see [F] [C1] symbol. Press [MENU] key to change [C1] > [C5]. 3]Press [SET] key to see [MON][TUE][WED][THU][FRI] and [F][COST] is blinking. Please change the [MID PEAK COST $0.16/KWh]. Press [SET] to change [ON PEAK COST $0.24/KWh]
4)Press [SET] key to change [OFF PEAK COST $0.10/KWh]
5)Press [SET] key to see [SUN][SAT] and [OFF PEAK COST $0.10/KWh]. Press [SET] to change [MID PEAK COST
$016/KWh]
6)Press [CHANGE] to save it. F. SELECT TARIFF TIME OF USE WEEK SELECTION & BILLING RATE: [C6]
1)Press [MENU] key for to change [CHANNEL] -> [SET]
2)Press the [SET] key 3 seconds to see [F] [C1] symbol. Press [MENU] key 5 times to change [C1] > [C6]. 3)Press [SET] key to see [F] blinking. Press [SET] key again to see "00:" on TIME screen. 4)Move cursor to proper position using [SET] key. 5)Press [UP][DOWN] key to adjust the Tier level, Time, Rate. 6)Press [SET] to move next position and adjust the correct value. Change all the correct value continuously. 7)Press [CHANGE] to store. G. TARIFF RATE FOR BASIC RATE: [C7]
1)Press [MENU] key for to change [CHANNEL] -> [SET]
2)Press the [SET] key 3 seconds to see [F] [C1] symbol. Press [MENU] key 6 times to change [C1] > [C7]. 3)Press [SET] key to see [F] blinking. Press [SET] key again to see Basic rate [$0.00] on COST screen. 4)Move cursor to proper position using [MENU] key. 5)Press [UP][DOWN] key to adjust the correct value. 6)Press [MENU] to move next position and adjust the correct value. Change all the correct value continuously. 7)Press [CHANGE] to store. H. MONTHLY KWH TARGET SETTING: [C8]
Your default setting is 300KWh. This is useful if your household is running on a monthly budget and you need to monitor costs closely. 1)Press [MENU] key for to change [CHANNEL] -> [SET]
2)Press the [SET] key 3 seconds to see [F] [C1] symbol. Press [MENU] key to change [C1] > [C8]. 3)Press [SET] key to see [F] blinking. Press [MENU] [UP][DOWN] key to adjust the correct wattage (W). 4)Press [CHANGE] to store. I. VOLTAGE SETTING: [C9]
Your default setting is 110 Volts. 1)Press [MENU] key for to change [CHANNEL] -> [SET]
2)Press the [SET] key 3 seconds to see [F] [C1] symbol. Press [MENU] key 8 times to change [C1] > [C9]. 3)Press [SET] key to see [F] blinking and [0 V]. Press [UP] key continuously until you reach [110V = AUTO V]. 4)Press [CHANGE] to store.
*If you are using Channel 2 10 with PIT3000, Your CRT3000 Channel (e.g. No.1) will get the Voltage value from PIT3000 automatically when you set the Voltage as [AUTO]. J. TEMPERATURE: [C10]
Your default setting is Centigrade, shown as C. You can choose to display the temperature in Fahrenheit, shown as F. 1)Press [MENU] key for to change [CHANNEL] -> [SET]
2)Press the [SET] key 3 seconds to see [F] [C1] symbol. Press [MENU] key 9 times to change [C1] > [C10]
3)If you want to select C, you must select [CELSI 0]
4)If you want to select F, you must select [FARRE 1]
5)Press [CHANGE] to save it. K. SELECT SYMBOL for the MONEY UNIT FOR EACH COUNTRY: [C11]
1)Press [MENU] key for to change [CHANNEL] -> [SET]
2)Press the [SET] key 3 seconds to see [F] [C1] symbol. Press [MENU] key to change [C1] > [C11]. 3)Press [SET] key to see [F] blinking. Press [MENU] [UP][DOWN] key to adjust symbol for the money unit. 4)Press [CHANGE] to store. It takes 20 seconds. L. ERASE THE KWh MEMORY (FACTORY DEFAULT SETTING): [C12]
1)Press [MENU] key for to change [CHANNEL] -> [SET]
2)Press the [SET] key 3 seconds to see [F] [C1] symbol. Press [MENU] key to change [C1] > [C12]. 3)Press [SET] key to see [F] blinking. Press [MENU] [UP][DOWN] key to adjust the correct number [0] ->[1]
4)Press [CHANGE] to store. It takes 20 seconds. 5)if you do not want to erase the kWh memory, please change [1] -> [0] and press [CHANGE]. M. GREEN HOUSE GAS UNITS:
Your SEM3000 can calculate the amount of CO2 emissions per unit of electricity used. Existing setting: 0.42kg/kwh N. TO REVIEW YOUR SETTINGS 1)Press [MENU] key for to change [CHANNEL] -> [SET]
2)Press the [SET] key 3 seconds to see [F] [C1] symbol. Press [MENU] key to scroll through your settings [C1] >
[C9]. 3)After review all the settings, press [MENU] to change [SET] -> [CHANNEL]
O. CALIBRATION STOP If you do not want to save the calibration data or made mistake during the calibration procedure, please do this:
Press [MENU] key continuously and you could see normal display state without calibration. Iden ntify live out going suppl y cable to e electricity me eter (usually look k at the mete er). grey, red or r brown and d located on the right as s you Unc lip the Sens sor and fit a round live c cable. Snap t the clip shut t to fasten s securely in p place (see th he images to o the righ t). Plea ase Note: It i is normal fo r the sensor to be loose e fit or be ab ble to slide a along the ca able. Fix t the mountin ng bracket (o optional) to the wall or t the baseboa ard used to mount your r meter, next t to the fuse e box or n nearby. Slot the Transm mitter into its s bracket an nd connect the Sensor cable to an y one of th he three Tran nsmitter soc ckets, loca ted on the b base of the unit. The photograph h on the righ ht shows a t ypical instal lation, with the Transmit tter mounted d on its bra acket to the right of th he meter an d the Senso or fitted arou und the live electricity ca able (usually grey, red or r brown). CO NGRATULA ATIONS You have now set up and installed yo our SEM3000 0 successful lly. For Trou bleshooting and additio onal informa ation plea ase turn over r this sheet or visit www w.smartwattm meter.com Keep p the equipm ment out of the reach o of children, e especially inf fants. Insta allation of th his product m must be carr ried out by a adults only a and if there is any doub bt, a qualified d electrician
. Do not install yo our equipme ent in a hum mid room (b bathroom, lau undry, kitche en etc.) or in n close prox imity to a ta ap or wate er source. Do o not expos e the equipm ment to mo isture, splash hes or spray y. The equipment and all ass sociated com mponents ar re for indoo or use and in normal te emperature conditions only. Avo id extreme t temperatures s. Store awa y from sourc ces of heat, ignition or f fire. Do n not attempt to open, di sassemble o or repair the equipment, other than to change t he batteries
. The equipment contains a r radio transm mitter, which may affect the operatio on of medica al or emerg ency equipm ment. Befo ore using thi is equipmen t in a medic cal environm ment, always seek the ad vice of a qu alified medi cal expert. The LCD screen is made of glass and m may break if d dropped. Plea ase take spe heal lth. cial care wh hen handling g a damaged d Display sc reen, as the e liquid cryst tals may be harmful to your Do n not cover th he ventilation n holes on t he equipme nt. Plea ase ensure yo ou read this Installation and Program mming Guid de carefully b before using g the equipm ment. If O WL+USB is used in a m manner not s specified by y 2 Save Ene ergy Ltd, the e protection provided by y the equipm ment may y be impaired d. Kor rins Inc. Rm6 608, Duncho on-daero #47 74, Junwon-g gu, Seongna am City, 462
-725 Korea
-1588 Fax:
+82-31-777 7-1587 hy yh@korins.kr r www.smar rtwattmeter.c com Tel:
+82-31-777 Kori ns Inc. guara antees that the SEM300 0 will work f for a minim um period o of 12 months s from date of purchase e and that it will be free from d defects in m materials, wo orkmanship or design. If during th his limited 1 year perio od of gua rantee, from m date of pu urchase, you find that th he equipme nt is not wo orking prope erly, you ma ay return it t to us and we will repl ace, or, (at o our discretio on) repair it, free of charg ge. Kori ns Inc. will not accept any liability for defects s arising from m fair wear and tear, a accidental or r willful dam mage, misu use or failure e to follow p product or s afety instruc ctions. If yo ou return an ny equipmen nt as faulty, Korins Inc. reserves the e right to te st the equip pment and i f found to b be in perf fect working order, to re eturn it to yo ou. In this e event, Korins s Inc. reserve es the right to charge fo or any testin ng or post tage costs in ncurred. This s does not a ffect your le egal rights re elating to eq quipment, wh hich is faulty y. War rranty condit tions only ap pply where P Proof of Purc chase is prov vided. To r return your S SEM3000 co ontact hyh@
korins.kr to report the issue and re eason for ret turning your r product. K orins Inc. will issue y you a form and refere nce number r. Once we have receiv ved the com mpleted for m and proo of of purc chase we wil ll commence e the returns s process. CO MPLIANCE E The CE marking g certifies th at this prod duct meets t the main req quirements o of the Europ pean Parliam ment and Co ouncil Dire ective 1999/5 5/EC. A copy y of the sign ed and date ed Declaratio on of Confo rmity is avai lable on Req uest. Your r Korins Inc. is manufact tured under an ISO 9001 1 Quality Ma anagement S System. missing, ple ase contact us: hyh@ko orins.kr If so omething is Tha ank you fo r choosing g the SEM 3000. Follo ow these sim mple steps to o set up you ur SEM3000 and you wil l be able to
:
Calc culate the am mount of p ower being used, the c cost of that power, the amount of associated greenhouse e gas emis ssions and d download re corded data to your PC. Befo ore setting u up your SEM 3000, please e ensure you u carefully re ead the Safe ety Precautio ons. Bef ore you st tart installa ation pleas se ensure you have:
1. A n electricity bill with det tails of your tariff and ra ates head or flat t bladed scre ewdriver 2. A small cross ISSU UE POSSIB BLE CAUSE T TRY THIS Disp play is blank Batterie es 0 i is displayed
-
---- are disp played No cur rent detecte ed Batterie es or lost syn nchronizatio on C Check they r replace batte eries are correc ctly installed d or nsor is corre properly o 1 1. Check Sen and closed a
(
(SEE STEP 5)
) nsor is conn 2 2. Check Sen ectly attache over Live c ed to cable ected to Sen nder C Check batter r replace bat p process. ries are corr tteries or ectly installe start full r ed or reset Read dings appea ar high Read dings appea ar low Tariff incorrec or voltage ct settings Sensor not closed properly may be C Check your
(
(see overleaf tariff and f) and reset voltage sett tings y if necessary e sensor cli ht fit then th erly. Check t
(up to 10 nsors and p maybe clo he core may the diamete 0mm cable 17mm for l osed, y not er of for large the clip on a straight p piece A Although the i f it is a tigh c close prope y your cable s standard se s sensor). R Reposition t o of cable.
- in display S See [STEP 2]
] for the pair ring resettin g.
----
Sync 2 chronization fails in ST TEP Display radio synchro In the u fails yo back to units instruct y Unit & Tr link and onize units h ransmitter h repeating have lost STEP 2 has failed unlikely even ou will need o factory se memory b tions:
nt that synch d to reset yo ettings and followin by hronizing our OWL clear the g these USB B RATING 5Vdc 5 00mA INS STALLING S SEM3000 I IN A 3-PH ASE SUPP LY If yo ou have a 3-
-phase supp ply you will n need two ad dditional Sen nsors and po ossibly large er sensors de epending on n the size of your cab bles. Fitting the sensors s is the sam me process a as above bu ut you will n need to ide ntify the co orrect cabl es using the e informatio n below:
Insta alling SEM30 000 in USA &
& JAPAN : W We supply 2 3-P PHASE WIR RING COD ES L1 until Ap pril Red L2 Yello ow UK 2006 6 ope
(inclu ude Brown Blac k Euro UK) from m April 2006 clamps for 100V ~ 120V V measurem ment. L3 Blue Grey Neut ral Black k Earth Green/yello
(green on o ow striped old installati ons) Blue Green/yello ow striped If yo ou are unsu ure about i installation please cons sult a qualif fied electric ian or visit www.theow wl.com for m more info rmation WH HAT IS THE E ALARM F FUNCTION N?
We have 3 di ifferent ala arm display y. 1)Th he alarm fun ction is desi igned to wa rn you when n your pre-d determined e electricity us sage peaks a above a spec cified rate
. This is usef ful if your ho ousehold is running on a budget an nd you need to monitor r costs closel ly. 2)M onthly targe et setting ov ver alarm. T This is usefu l if your ho ousehold is running on a monthly budget and you need d to monito r costs close ely. 3)Bla ack out time e alarm. This s is useful fo or to support t the power plant & gov vernment. UN DERSTAND DING TARI FFS AND TIERED TA ARIFFS Elec tricity suppl iers sell elec ctricity at dif fferent rates s to different t people acr ross the cou untry. Rates may also va ry at diffe erent times o of the night or day. The e rate you pa ay for your electricity is called a ta ariff and is clearly ident tified on y your electric ity bill. Some electricity users will have primary/secondary rates based on usage. To make use of this data you will need to calculate an average based on usage and enter this figure into tariff 1. CAN I MONITOR APPLIANCE LEVEL?
The Sensor is unable to detect current flow when clipped an appliance lead with earth, neutral and live cables. The sensor will only work when clipped over a live phase cable. HOW MUCH DATA CAN BE STORED ON MY SEM3000?
Data is stored for the last 1800 days as hourly value of electricity used, cost of electricity used based on Tariff rates entered for that day, and amount of CO2 emissions based on conversion factor for that day. This data is accessible by connecting pc-cable and software. Data is also stored every 12 seconds for the last 1 day and this is accessed using the automatic download function of the software application supplied with the Display Unit. INSTALLING THE SOFTWARE APPLICATION TO DOWNLOAD THE DATA TO PC?
Please read the User Manual on the Software Application file supplied with SEM3000. Install the software following the installation guide in the user manual. Follow the Getting Started section of the User Manual, to get the New Hardware installed, and to add the USB as a Connected To device in the software. HOW DO I DOWNLOAD THE DATA TO MY PC?
Simply connect the port of the Display Unit to the PC with specially made mini-USB cable, and the last 30 days data (or number days data stored if less than 30 days) will automatically download to the software database. HOW OFTEN DO I NEED TO DOWNLOAD THE DATA TO MY PC?
Data should be downloaded every 30days since last data download or sooner. If 30 days is exceeded since last download, then the data for the days between the last 30 days and last download of data will be overwritten in the monitor, hence there will be no data saved for those days in the data abase. Rech hargeable A lkaline Batte eries can be pow wer adapter m mainly. used to ope erate your D Display Unit only few da ays. Therefor re please us e AC Plea ase Note: If y you are conc cerned or co onfused by t the installatio on process p please call c ustomer ser rvices on _82 2-31-
777-
-1588 or e mail hyh@
@korins.kr FCC ID: 2AD97-SEM3110U FCC Part 15.19 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Part 15.21 Any changes or modifications (including the antennas) to this device that are not expressly approved by the manufacturer may void the user's authority to operate the equipment. FCC Part 15.105 (B) Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications, However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. Modifications not expressly approved by the manufacturer could void your authority to operate the equipment under FCC rules.