Connect MT150 to a PC using an RSINTOO! adapter (see Figure 3). The following communication parameters can be programmed or modified:
Protocol e Station address e System e Group Number of words (in a burst) e Alarm repetitions e Test repetitions e Periodic test (hours:min) e Parity e Input delay e Input polarity e Transmit frequency (MHz) 16-pin flat cable Figure 3: MT150 - PC Connection Configuration Operating Instructions 1. Connecting MT150 to GUP10 utility program 2. Changing Devices 3. Loading Device Parameter Values 4. Changing Device Parameter Values 5. Updating Parameter Value Changes 6. Confirming Parameter Value Changes 7. Activating Self Test Connecting MT150 to GUP10 1. Connect MT150 to a PC using the RSINTO01 adapter, see Figure 3. 2. Click Start Programs>
KP Utilities>GUP10, or click shortcut. The GUP10 main screen displays, showing the device type, version, and suitable default parameters. ae ark:
Figure 4: GUP10 Main Screen (LARS) Changing Devices Various KP devices can be programmed with GUP10 utility software. When started, the GUP 10 utility software program automatically connects to the device currently connected to the PC. Loading Device Parameter Values Device parameter values must be loaded for each device connected to GUP1O utility software. When devices are changed, ensure parameter values for the current device are loaded. To Load Device Parameter Values 1. From the GUP10 main screen, click Prompt ? (Ctrl P). 2. Click Read (Ctrl R). The name of the device type, version, and suitable parameters are displayed. Ensure the correct name and version of the device are displayed. If not, ensure the device is properly connected to the PC. If the Communication Error screen continuously appears on the screen, consult the GUP10 User Manual. Operating Voltage |_ 10 - 15 VDC Standby Current 15mA max. Tx Current | max. Power Output SW Freq. Stability +5ppm at operating temp range Operating Temp. | -23F - 141F
(-30C - 60C) Storage Temp. -40F - 158F
(-20C - 70C) Weight 0.5 Ib.
(230 gr.) Changing Device Parameter Values Device parameter values can be changed, as required. To Change Device Parameter Values Type the new parameter value in the designated parameter text box. Updating Parameter Value Changes To Update Parameter Value Changes 1. Click Send (Cal S). The Send Warning dia. og box displays Are you sure?
Choose one:
e Click Yes, to update parameter changes. OR 9 Click No, to return to the GUP10 main screen without updating changes. Confirming Parameter Changes Ensure Parameter changes have been updated. To Confirm Parameter Changes From the GUP10 main screen, click Read (Ctrl R). The GUP10 main sereen displays the updated device type, version, and suitable parameters. Performing Self Test After KP device parameter values have been loaded, perform self test to ensure the device is working properly. To Perform Self Test 1. Disconnect the device from the PC. 2. Press the self-test button. 3. Observe the self-test LED. (Refer to Table 2 for self-test results.) Online HELP To view a brief explanation of any MT150 parameter, click the required parameter text box. The cursor will appear in the text box clicked, and the valid parameter range displays at the bottom of the screen together with a brief explanation. The operator can select the suitable parameter from the online HELP line.