P&P Large Module with USB or optional with RS232 Version 1.3 User - Manual Kronegger GmbH Parkring 1 A-8074 Grambach Austria Phone +43 (0) 316-403125 Documentation P&P Large Module with USB V1.3 07.07.11 Table of Contents Table of Contents .................................................................................................... 2 1 Introduction ..................................................................................... 3 2 Getting Started ................................................................................ 4 3 Instruction Set ................................................................................. 5 Generic Commands Overview ............................................................................. 5 4 Hardware ......................................................................................... 6 4.1 Features ....................................................................................................... 6 4.2 Dimensions:.................................................................................................. 7 4.3 Pinout ........................................................................................................... 7 Electrical characteristics of USB Supply Pins ............................................... 8 4.4 Electrical characteristics of RS232 Supply Pins ........................................... 8 4.5 4.6 Electrical characteristics of LED Pins ........................................................... 9 Integration ....................................................................................... 9 5 Kronegger GmbH 2 Introduction Documentation P&P Large Module with USB V1.3 07.07.11 1 Kronegger GmbH. provides customer support and optional design in services for properly integrating the products. Since we do not have full information on customers applications or products, it is due to the customer to verify that the integrated products are suitable for the application intended and that no patents or intellectual property rights are infringed. Integrating the products into the customers application is a development process that requires special experience, professional skills and involves usual technical risks. Kronegger GmbH. assumes no responsibility or liability for customers applications, their performance, the required development effort, production, installation, operation, their suitability, reliability and safety. The products are not designed for applications where malfunction could cause potential risk of death, personal injury or environmental damage. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. If using a permanently affixed label, the modular transmitter must be labeled with its own FCC identification number, and, if the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: Contains Transmitter Module FCC ID ZKCPP-0403-3003 or contains FCC ID ZKCPP-0403-
3003. Any similar wording that expresses the same meaning may be used. FCC Compliance Statement:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. The manual has been written to the best of our knowledge. We do not guarantee the correctness and completeness of the provided information and insist on the good practice of crosschecking during the customers development process through sufficient testing coverage. Feedback on errors in the manual are highly appreciated. This document may be used to support the integration of Kronegger products. Any other use, duplication, storage or circulation is not authorized shall be prosecuted as a violation of copyright laws. Kronegger GmbH 3 Documentation P&P Large Module with USB V1.3 07.07.11 2 Getting Started As factory default the data are transmitted at 115200, n, 8, 1 and no handshake. Two protocol modes are available. As default the binary protocol is used. To change the protocol type or the baud rate you have to configure the EEPROM (see EEPROM Memory Organization). First of all you need a Mifare+ reader with an USB cable (Type A to mini B) For the communication with the reader you have to download a virtual com-port driver (VCP) for the USB interface. Please check the following link for the latest version:
http://www.ftdichip.com/Drivers/VCP.htm The driver will map the USB to a serial communication port. Install the driver and connect the reader. It will show new hardware detected. You can check your setup under System Setting/System/Hardware/Device Manager to find out which com-port had been assigned to your reader. Optionally you can change the com number in the advanced settings of the com-port. For the communication with the reader you need the ReaderTool which is delivered with any Kronegger Reader. The Microsoft .NET Framework 2.0 (or any higher version) needs to be installed first in order to run the ReaderTool:
http://www.microsoft.com/downloads/details.aspx?familyid=0856EACB-4362-4B0D-
8EDD-AAB15C5E04F5&displaylang=en The ReaderTool needs no installation, simply start it and the reader will be selected automatically. Now you can communicate with your Mifare+ reader. Step by Step:
Download and install the FTDI driver Connect the Reader via the USB cable to the PC Download and install the Microsoft .NET Framework Start the ReaderTool Now you can communicate with the reader Kronegger GmbH 4 Instruction Set Documentation P&P Large Module with USB V1.3 07.07.11 3 Following table describes all commands of the reader device. Each command sends a response to the host. Exceptions are mentioned explicitly. The green LED is acknowledging a successfully executed command. The red LED indicates an error. Generic Commands Overview Generic commands apply to all supported tags. Command Description b
'c'
e k Get Serial Number Continuous Read Send SAM APDU Lock Block
'poff '/'pon'
Antenna Power off/on
'pp'
Set/Get User ports pr/pw Read/Write User ports
're'
's'
t
'v'
vs
'we'
'x'
Read EEPROM register Select Send 14443-4 APDU get Version Set Version Write EEPROM register Reset Applicable OEM Micro Plus XXL
Kronegger GmbH 5 Documentation P&P Large Module with USB V1.3 07.07.11 4 Hardware 4.1 Features Dimensions Antenna Interface type Reading distance up to 100mm depending on tag Signaling Power supply 2 reading LEDs, power LED 5 VDC 10% regulated 110,0 x 67,0 x 7,0 (LxWxH) 1 mm on board USB 2.0; RS232 (optional) Kronegger GmbH 6 Documentation P&P Large Module with USB V1.3 07.07.11 4.2 Dimensions:
All dimensions listed in mm PCB thickness: 1,5 0.1 mm 4.3 Pinout Note: if RS232 option is provided, USB will not be available and vice versa. Header (male) for RS232 USB Connector 1 2 3 4 5 1 2 3 4 5 Reading LEDs LEDG LEDR GND
+5V Power LED Kronegger GmbH 7 Documentation P&P Large Module with USB V1.3 07.07.11 4.4 Electrical characteristics of USB Supply Pins PIN No. Min. Typ. 5 V Max. 100 mA 500 mA Description Supply Voltage Supply Current
-0,5 V
-0,5 V 3,3 V 3,3 V 3,8 V Data Minus Data Plus 3,8 V 1,5 k pull up
Do not connect Power Ground PIN VCC D-
D+
RFU GND 1 2 3 4 5 4.5 Electrical characteristics of RS232 Supply Pins PIN RFU
+5V GND RX TX PIN No. Min. Typ. Max. Description 1 2 3 4 5 4,5 V Do not connect 5,0 V 150 mA 5,5 V 250 mA Supply Voltage Supply Current GND Ground for Power Supply and Interface
-15 V 3 k 5 V 200 k 5 k 9 V
+15 V 7 k RS232 Voltage Levels Input Impedance RS232 Voltage Levels Output Impedance Kronegger GmbH 8 Documentation P&P Large Module with USB V1.3 07.07.11 4.6 Electrical characteristics of LED Pins PIN PIN No. Min. LEDG LEDR GND
+5V 1 2 3 4 Typ. 1,4 V Max. Description VDDmax Read-LED +
@11 mA 11 mA 15 mA 1,4 V VDDmax Read-LED -
@11 mA 11 mA 15 mA GND 1,4 V Power -
VDDmax Power +
@11 mA 11 mA 15 mA Integration 5 Kronegger GmbH 9 Documentation P&P Large Module with USB V1.3 07.07.11 Version History Date Revision Number 14.01.2011 Version 1.1 14.03.2011 Version 1.2 07.07.2011 Version 1.3 Kronegger GmbH 10