Kronegger XXL+ P&P Reader Version 2.0 User - Manual Kronegger GmbH Parkring 1 A-8074 Grambach Austria Phone +43 (0) 316-403125 Documentation Kronegger XXL+ P&P Reader 19.4.12 Table of Contents Table of Contents .................................................................................................... 2 1 Introduction ..................................................................................... 3 2 Getting Started ................................................................................ 4 3 Instruction Set ................................................................................. 5 Generic Commands Overview ............................................................................. 5 4 Hardware ......................................................................................... 6 4.1 Features ....................................................................................................... 6 4.2 Dimensions:.................................................................................................. 7 4.3 Pinout ........................................................................................................... 7 Electrical characteristics of Connector1: ...................................................... 8 4.4 4.5 Electrical characteristics of Connector2: ...................................................... 9 5 Integration ..................................................................................... 10 Kronegger GmbH 2 Documentation Kronegger XXL+ P&P Reader 19.4.12 1 Introduction Kronegger GmbH. provides customer support and optional design in services for properly integrating the products. Since we do not have full information on customers applications or products, it is due to the customer to verify that the integrated products are suitable for the application intended and that no patents or intellectual property rights are infringed. Integrating the products into the customers application is a development process that requires special experience, professional skills and involves usual technical risks. Kronegger GmbH. assumes no responsibility or liability for customers applications, their performance, the required development effort, production, installation, operation, their suitability, reliability and safety. The products are not designed for applications where malfunction could cause potential risk of death, personal injury or environmental damage. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. If using a permanently affixed label, the modular transmitter must be labeled with its own FCC identification number, and, if the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: Contains Transmitter Module FCC ID ZKCFORT-9912-2009 or contains FCC ID ZKCFORT-
9912-2009. Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an example of which must be included in the application for the equipment authorization, or, must provide adequate instructions along with the module which explains this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. The manual has been written to the best of our knowledge. We do not guarantee the correctness and completeness of the provided information and insist on the good practice of crosschecking during the customers development process through sufficient testing coverage. Feedback on errors in the manual are highly appreciated. This document may be used to support the integration of Kronegger products. Any other use, duplication, storage or circulation is not authorized shall be prosecuted as a violation of copyright laws. Kronegger GmbH 3 Documentation Kronegger XXL+ P&P Reader 19.4.12 2 Getting Started As factory default the data are transmitted at 115200, n, 8, 1 and no handshake. Two protocol modes are available. As default the binary protocol is used. To change the protocol type or the baud rate you have to configure the EEPROM (see EEPROM Memory Organization). First of all you need a Mifare+ reader with an USB cable (Type A to mini B) For the communication with the reader you have to download a virtual com-port driver (VCP) for the USB interface. Please check the following link for the latest version:
http://www.ftdichip.com/Drivers/VCP.htm The driver will map the USB to a serial communication port. Install the driver and connect the reader. It will show new hardware detected. You can check your setup under System Setting/System/Hardware/Device Manager to find out which com-port had been assigned to your reader. Optionally you can change the com number in the advanced settings of the com-port. For the communication with the reader you need the ReaderTool which is delivered with any Kronegger Reader. The Microsoft .NET Framework 2.0 (or any higher version) needs to be installed first in order to run the ReaderTool:
http://www.microsoft.com/downloads/details.aspx?familyid=0856EACB-4362-4B0D-
8EDD-AAB15C5E04F5&displaylang=en The ReaderTool needs no installation, simply start it and the reader will be selected automatically. Now you can communicate with your Mifare+ reader. Step by Step:
Download and install the FTDI driver Connect the Reader via the USB cable to the PC Download and install the Microsoft .NET Framework Start the ReaderTool Now you can communicate with the reader Kronegger GmbH 4 Documentation Kronegger XXL+ P&P Reader 19.4.12 Instruction Set 3 Following table describes all commands of the reader device. Each command sends a response to the host. Exceptions are mentioned explicitly. The green LED is acknowledging a successfully executed command. The red LED indicates an error. Generic Commands Overview Generic commands apply to all supported tags. Command Description b
'c'
e k Get Serial Number Continuous Read Send SAM APDU Lock Block
'poff '/'pon'
Antenna Power off/on
'pp'
Set/Get User ports pr/pw Read/Write User ports
're'
Read EEPROM register
's'
t
'v'
Select Send 14443-4 APDU get Version vs Set Version
'we'
Write EEPROM register
'x'
Reset Applicable OEM Micro Plus XXL Kronegger GmbH 5 Documentation Kronegger XXL+ P&P Reader 19.4.12 4 Hardware 4.1 Features Dimensions 73,0 x 67,0 x 10,0 (LxWxH) 1 mm Antenna 45,0 x 70,0 x 10,0 (LxWxH) 1 mm (only P&P small) on board Interface type RS232 Reading distance up to 50mm depending on tag Signaling reading LED, power LED Power supply 5, 12 VDC 10% regulated Kronegger GmbH 6 Documentation Kronegger XXL+ P&P Reader 19.4.12 4.2 Dimensions:
All dimensions listed in mm PCB thickness: 1,5 0.1 mm 4.3 Pinout 7 6 5 4 3 2 1 Connector1 Connector2 7 6 5 4 3 2 1 Kronegger GmbH 7 Documentation Kronegger XXL+ P&P Reader 19.4.12 4.4 Electrical characteristics of Connector1:
PIN PIN No. Min. Typ. Max. Description RFU VCC1 GND RX RS232 TX RS232 RX TTL TX TTL 1 2 3 4 5 6 7 NC 4,5 V 5,0 V 5,5 V Supply Voltage 150 mA 250 mA Supply Current GND Ground for Power Supply and Interface
-30 V 3 k
+30 V RS232 Voltage Levels 5 k 7 k Input Impedance 5 V 9 V RS232 Voltage Levels 300 Output Impedance 3,3 V 8 mA 3,3 V 8 mA 5,5 V TTL Input from Host 25 mA 3,6 V TTL Output to Host 25 mA Kronegger GmbH 8 Documentation Kronegger XXL+ P&P Reader 19.4.12 4.5 Electrical characteristics of Connector2:
PIN PIN No Min. Typ. Max. Description VCC2 RFU GND RX RS232 TX RS232 RX TTL TX TTL 1 2 3 4 5 6 7 11 V 12 V 13 V Supply Votage 150 mA 250 mA Supply Current GND RFU Ground for Power Supply and interface
-30 V 3 k
+30 V RS232 Voltage Levels 5 k 7 k Input Impedance 5 V 9 V RS232 Voltage Levels 300 Output Impedance 3,3 V 8 mA 3,3 V 8 mA 5,5 V TTL Input from Host 25 mA 3,6 V TTL Output to Host 25 mA Kronegger GmbH 9 Documentation Kronegger XXL+ P&P Reader 19.4.12 5 Integration Kronegger GmbH 10 Documentation Kronegger XXL+ P&P Reader 19.4.12 Version History Date Revision Number 19.04.2012 Version 2.0 Kronegger GmbH 11