all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 431.10 KiB | February 09 2021 / August 09 2021 | delayed release | ||
1 |
|
Internal Photo | Internal Photos | 2.45 MiB | February 09 2021 / August 09 2021 | delayed release | ||
1 |
|
External Photo | External Photos | 484.42 KiB | February 09 2021 / August 09 2021 | delayed release | ||
1 |
|
Label Location | ID Label/Location Info | 31.22 KiB | February 09 2021 / February 10 2021 | |||
1 | Block Diagram | Block Diagram | February 09 2021 | confidential | ||||
1 |
|
Confidential Letter | Cover Letter(s) | 46.78 KiB | February 09 2021 / February 10 2021 | |||
1 |
|
MPE Test Report | RF Exposure Info | 271.14 KiB | February 09 2021 / February 10 2021 | |||
1 | Operational Description | Operational Description | February 09 2021 | confidential | ||||
1 |
|
Power of Attorney Letter | Cover Letter(s) | 39.64 KiB | February 09 2021 / February 10 2021 | |||
1 |
|
RF Test Report | Test Report | 863.04 KiB | February 09 2021 / February 10 2021 | |||
1 |
|
SDoC Attestation Letter | Attestation Statements | 38.85 KiB | February 09 2021 / February 10 2021 | |||
1 | Schematics | Schematics | February 09 2021 | confidential | ||||
1 |
|
Test Photo | Test Setup Photos | 289.37 KiB | February 09 2021 / August 09 2021 | delayed release |
1 | User Manual | Users Manual | 431.10 KiB | February 09 2021 / August 09 2021 | delayed release |
K60c and Wireless Communication System
User Guide
Release 1.0
October 16, 2020
Kwikbit is a trademark of Kwikbit Inc.
©2016-2020 Kwikbit Inc. All rights reserved.
K60c User Guide
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules (for USA) and ISED rules (for Canada). These limits are designed
interference in a residential installation. This
to provide reasonable protection against harmful
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
You can determine whether your equipment is causing interference by turning it on and off. If the
interference stops, it was probably caused by the equipment. If the equipment causes interference
to radio or television equipment, try to correct the interference by using one or more of the
following measures:
▪
▪
▪
▪
Reorient or relocate the receiving antenna.
Increase separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician.
Any modifications to this product which are not authorized by Kwikbit Inc. could void your authority
to operate this equipment.
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE
TO CHANGE WITHOUT NOTICE.
SUBJECT
AND
RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED
WITHOUT WARRANTY OF ANY KIND. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR
APPLICATION OF ANY PRODUCT.
INFORMATION,
STATEMENTS,
ALL
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE ARE
PROVIDED “AS IS” WITH ALL FAULTS. KWIKBIT DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE
PRACTICE.
IN NO EVENT SHALL KWIKBIT OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL,
CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR
LOSS OF DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF
KWIKBIT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Kwikbit K60c User Guide
- 2 -
K60c User Guide
Table of Contents
Preface
Preface overview
About this guide
Additional documentation
Additional help
Kwikbit K60 System Overview
K60 System Description
Technical Specifications
System Specifications
Radio Specifications
Mechanical, Power and Environmental Specifications
System Enclosure
System Throughput
Element and Network Management
Ethernet Bridge Support
Installation Planning
LED Indicator Codes
Using the K60 Web User Interface (UI)
Using the K60 Command Line Interface (CLI)
Requirements
K60 Web UI Page
Logging In
Requirements
Kwikbit K60c User Guide
5
5
5
5
6
6
8
11
11
11
12
13
14
14
17
17
17
18
18
19
19
21
21
- 3 -
K60 CLI commands
System Provisioning
Appendices
Glossary
Initial System Setup and IP Configurations
FCC Regulatory Statement
FCC Radiation Exposure Statement
ISED Industry Canada Regulatory Statement
ISED Industry Canada Radiation Exposure Statement
K60c User Guide
21
21
22
24
24
25
25
26
26
Kwikbit K60c User Guide
- 4 -
K60c User Guide
Thank you for choosing the K60c system from Kwikbit. This guide introduces you to system
concepts, system architecture and commonly used terms.
1 Preface
1.1 Preface overview
This preface describes:
● Audience for this guide
● Additional documentation
● Where to go for more help
1.2 About this guide
This guide provides an overview of the K60c system, its components, its network
architecture, and how it is configured and deployed.
This guide is intended for network and system administrators who must install, configure,
and manage K60 distribution networks. This guide is meant to provide an overview of the
system. This guide does not provide detailed information on network configuration.
It is assumed readers of this guide are familiar with:
● Basic networking concepts
● Layer 2 (link layer) of OSI model
● Layer 3 (network layer) of OSI model
● Routing and switching in networks
● Radio frequency (RF) systems engineering
● Virtual local area network (VLAN) technology
1.3 Additional documentation
● Information about network management is available in the Kwikbit Edge Controller
User Manual
Kwikbit K60c User Guide
- 5 -
K60c User Guide
1.4 Additional help
Kwikbit is committed to providing our customers with high quality technical support via the
following methods:
Web
Phone
support.kwikbit.com
support@kwikbit.com
+1 (952) 657-5628
2 Kwikbit K60c product versions
The K60c is also made in an enhanced-range version that uses a different internal antenna.
These units are marked “K60c+.” This guide applies to both versions. Specifications and
operation are the same except as noted.
3 Kwikbit K60c System Overview
Figure 1: K60c System in a Point-to-Multipoint (PtMP)
Wireless Communication Application
Kwikbit is a leader in gigabit wireless distribution solutions that intelligently adapt to
challenging environments to maximize performance and reliability.
The K60c system operates in the 60 GHz unlicensed frequency band and is designed
primarily for line-of-sight (LoS) operation. Non-line-of-sight (NLoS) operation is possible
Kwikbit K60c User Guide
- 6 -
K60c User Guide
within short range and in the presence of reflective surfaces. By utilizing advanced
beamforming techniques, the K60c system automatically adapts in Point-to-Multipoint
(PtMP) communication configuration and is adaptable to changes in the operating
environment. The beam forming capability also makes system installation simple for
non-technical staff as precise mechanical alignment, as required by previous generation 60
GHz systems, is not required.
The K60c system is designed for use in multiple applications including gigabit access, IoT
backhaul (sensors, security cameras, etc.), optical fiber extension, and corporate and
enterprise data services by providing 1 Gbps of symmetric throughput.
The K60c system operates in unlicensed Time Division Multiplexing (TDD) band 57.05 –
64.00 GHz in both Point-to-Point (PtP) and Point-to-Multipoint (PtMP) configurations. Some
of the main product characteristics are shown in Table 1.
Table 1: Main K60c Characteristics
Duplex Mode
Time Division Multiplexing (TDD)
Physical Layer / Antenna
System
K60c: 64 patch beamforming
antenna
K60c+: 128 patch beamforming
antenna
Operation Configuration
PtP and PtMP
Capacity
Symmetry
1.86 Gbps goodput aggregate
Dynamic downlink (DL) and uplink
(UP) based on offered load
Frequency of Operation
57.05 – 64.00 GHz
Channel Bandwidth
2.16 GHz
Network Interface
1x 1 gigabit Ethernet
Form Factor
7.3 x 3.15 x 1.2” with integrated
antenna
Kwikbit K60c User Guide
- 7 -
The K60c system consists of the following components:
K60c User Guide
● Hub Unit: control communication to one or more Remote Units
● Remote Unit: scan for available Hub Units and connect to the Hub configured or
assigned via the Edge Controller
● Edge Controller: Optional appliance computer that provides WebUI tools for
deployment planning, commissioning, network configuration, management,
monitoring and fault isolation. Edge controller is highly recommended for networks
of medium and large scale.
The K60c Hub and Remote Units are identical from a hardware perspective, only differing
in software configuration. The K60c has a small form factor that can be easily and
unobtrusively deployed in many different outdoor environments.
K60c units will interoperate with other products in the Kwikbit K60 product line.
4 K60c System Description
Kwikbit’s K60c wireless outdoor networking solution is designed to meet the requirements
of network planners where rapid and flexible deployment, high reliability, multi-gigabit
capacity and excellent latency performance are needed. Applications for the system include
IoT gateway aggregation, Wi-Fi access point backhaul, video camera connectivity and other
gigabit IP based applications. The system can function either as a Point-to-Point (PtP) or
Point-to-Multipoint (PtMP) wireless Ethernet bridge.
Some of the main characteristics of the system include:
● Time Division Duplex (TDD): The K60c solution features TDD access mode with
variable frame length.
● Adaptive Modulation with Link Adaptation: The K60c system supports BPSK,
QPSK on both the downlink and uplink path to achieve high capacity in the channel
bandwidth (1.86 Gbps Ethernet layer throughput for combined downlink and uplink
traffic).
● Beamforming: Use of the 60 GHz band allows extremely fast communication, but
also presents the challenge of limited propagation. Signals in the 60 GHz band are
also more susceptible to disruption from physical barriers than at lower
frequencies. The K60c system includes adaptive beamforming, a technique that
enables robust multi-gigabit communications at greater distances. Kwikbit’s
beamforming feature uses directional antennas to reduce interference and
automatically focus a signal between two devices into a concentrated beam. During
the beamforming process, devices establish communication and then fine-tune
Kwikbit K60c User Guide
- 8 -
K60c User Guide
their antenna settings to improve the quality of directional communication until
there is enough capacity for the desired data transmission.
One key benefit of Kwikbit’s beamforming is that if an obstacle blocks the line of sight
between two devices, for example, if someone walks between them, the devices can
quickly establish a new communications pathway. Another benefit of the K60c
beamforming is that non-technical personnel can quickly and easily install the
system. Precise physical alignment of the radios, as required with previous 60 GHz
products, is not required with the Kwikbit system. The beamforming feature also
enables the PtMP communication capability of the system.
● Power Management: The K60c system utilizes the scheduled access mode to
reduce power consumption. Devices connected with each other via a directional link
schedule the periods during which they communicate and, in between those
periods, they can sleep to save power. This capability allows devices to more
precisely tailor their power management to their actual traffic workload, reduces
potential co-channel interference and enables efficient spectrum utilization.
● Advanced Security: The K60c system utilizes strong security mechanisms, including
Galois/Counter Mode, a highly-efficient mode of encryption that is designed to
support higher communication speeds. Encryption is based on the
government-grade Advanced Encryption Standard (AES) and is implemented in
hardware for performance and efficiency.
● Integrated Antennas: The K60c units integrate a specially-designed antenna
module that enables a 90º azimuthal and 40º vertical beam sweep range.
● PtMP with Dynamic Bandwidth Allocation: The K60c system can operate in PtP or
PtMP configurations with up to eight Remotes. The capacity allocated to each
Remote is variable according to the requirements of connected devices.
● Compact Form Factor: The K60c transceiver units are highly integrated, compact,
and lightweight, so they can be easily mounted on poles, pipes and walls.
● Connectivity: K60c devices include a standard RJ45 Gigabit Ethernet port that
serves as a PoE In port.
The Kwikbit K60c system provides these network management features:
● Each K60c unit incorporates a WebUI. This WebUI enables configuration, fault
management, and administration of the unit, as well as provides system state and
performance information.
Kwikbit K60c User Guide
- 9 -
of the WebUI.
● A command-line interface (CLI) is also available. It provides features similar to those
K60c User Guide
Figure 2: K60c Hub and Remote WebUI interface page
● The Kwikbit Edge Controller is a very powerful part of the Kwikbit solution. The Edge
Controller connects through an Ethernet connection to the root K60c unit and
enables non-technical personnel to physically install an entire network without K60c
units being configured on the bench in advance. A local or remote IT resource can
design, commission and manage the network using the Edge Controller’s WebUI.
Kwikbit K60c User Guide
- 10 -
K60c User Guide
The Edge Controller can be connected to the cloud for remote management of
multiple locations.
5 Technical Specifications
5.1 System Specifications
Aggregate
capacity
Up to 1.8 Gbit/sec (Layer 2/ Ethernet)
Ethernet frame
type
Transparent bridging of all Ethernet types including VLAN
and VLAN stacking
Latency
250 microseconds average
L2 switching
Complete Layer 2 switching with VLAN support
Security
AES 128 with automatic secure key distribution
Network
Attributes
Network
Interfaces
Ethernet bridge, 802.1Q, DSCP/ToS/802.1p (IPv4/v6) and
802.1ad/ QinQ tagging
1 x GbE RJ-45 with PoE in
Other Interfaces
LED indicator for power, link condition, signal strength, and
unit location
Provisioning
Zero-touch deployment and commissioning with Edge
Controller web application
Management
Web GUI, CLI, REST API and Edge Controller (optional)
5.2 Radio Specifications
Access
Technology
Single carrier beamforming physical layer
Duplex
Time Division Multiplexing (TDD)
Kwikbit K60c User Guide
- 11 -
K60c User Guide
Modulation
BPSK, QPSK; 8 levels of adaptive modulation and coding
schemes
Frequencies
57.05 - 64.00 GHz
2.16 GHz
Channel
Bandwidth
Antenna
System
Output power
(maximum)
Typical Range
K60c+: 128 patch beamforming antenna
K60c: 64 patch beamforming antenna
Each with 90˚ horizontal and 40˚ vertical scan range
40 dBm EIRP
K60c+: 400 meters
K60c: 225-285 meters
5.3 Mechanical, Power and Environmental Specifications
Configuration
Single-piece indoor unit with integrated antenna
Dimensions
(H x W x D)
185 x 80 x 30 mm
7.3 x 3.15 x 1.2 inches
Weight
255g / 9 ounces
Power Input
802.3af PoE
Power
Consumption
K60c: 6 watts
K60c+: 8 watts
Operating
temperature
-30˚C to +55˚C
Humidity
Up to 95% non-condensing
ESD
EMC
IEC EN 61000-4-2
IEC EN 61000-4-3
Kwikbit K60c User Guide
- 12 -
K60c User Guide
5.4 System Enclosure
Figure 3: Ports on K60c (Hub and Remote)
The K60c enclosure is a rugged casing that is supplied with a combination pole and wall
mounting bracket. The mounting bracket allows for a range of orientation flexibility to
enable mounting in challenging locations. Units installed at the same location can be
interconnected for medium and large network deployments.
Kwikbit K60c User Guide
- 13 -
The mechanical enclosure for the transceiver Module has an RJ45 for Gigabit Ethernet
network connectivity and PoE power input (802.3at, 802.3at+, or 802.3bt).
K60c User Guide
6 System Throughput
The K60c system uses time division duplexing (TDD) access mode, employing a single
frequency for both transmit and receive paths. The throughput for the downlink and uplink
depends on a downlink-to-uplink frame bandwidth ratio. The ratio is automatically
adjusted based on the offered load in each direction, taking into account all Remotes
connected to a Hub in PtMP. Furthermore, the system’s throughput depends on the
Modulation and Coding Rate (MCS) which varies according to link and signal conditions. The
following table details Ethernet uplink and downlink combined throughput for a K60c link.
Table 8: Throughput Performance for Cyclic Prefix of 1/8
MCS Index
Modulation
NCBPS
Repetitions
Code Rate
1
2
3
4
5
6
7
8
π/2 BPSK
π/2 BPSK
π/2 BPSK
π/2 BPSK
π/2 BPSK
π/2 QPSK
π/2 QPSK
π/2 QPSK
1
1
1
1
1
2
2
2
2
1
1
1
1
1
1
1
Data Rate
(Mbit/s)
310
620
775
930
1007
1240
1550
1860
1/2
1/2
5/8
3/4
1/2
5/8
3/4
13/16
7 Element and Network Management
The K60c system supports the following network management interfaces:
Kwikbit K60c User Guide
- 14 -
K60c User Guide
● K60c Web Interface (WebUI). Accessible via HTTPS, the K60c WebUI provides an
interactive visual toolset that allows an operator to modify the full configuration of
the K60c system as well as view state, fault, and performance indicator.
● K60c Command Line Interface (CLI) provides a set of commands that allows the
operator to manage, maintain and troubleshoot the system.
● The Edge Controller WebUI application provides complete access to configuration,
state, performance and fault information for all K60c units in a network system.
The WebUI network management interface on the K60c system is accessible via HTTPS.
Power the unit with a PoE power source. Connect to the K60c system with your browser
utilizing one of the following methods:
● Local Name: Connect a K60c transceiver unit directly to your computer by plugging
an Ethernet cable into the RJ45 connector. In the URL field on your computer’s
browser type https://KB-XX-XX-XX.local where KB-XX-XX-XX is the Host name of
the unit that appears on the label on the side of the unit. For example, if the unit
Host name is KB-C5-6B-78, then the URL address of the unit is
https://KB-C5-6B-78.local. Your browser will display a warning stating that the
connection is not secure. You may ignore the warning and proceed connecting to
the unit. To avoid the warning, please go to the Kwikbit support website, download
the Kwikbit security certificate, and install it on your browser.
● Management IP Address: Connect using the IPv4 IP address. The factory-assigned
IP address appears on a temporary label on the unit. Be sure to use https:// rather
than http.
The Command Line Interface network interface on the K60c system is accessible via Secure
Shell (SSH). Power the unit with a PoE power source. Connect to the K60c system with your
terminal application utilizing one of the following methods:
● Local Name: Connect a K60c transceiver unit directly to your computer by plugging
an Ethernet cable into the RJ45 connectors. In a terminal application window on
your Linux, Unix or MAC computer type ssh kwikbit@KB-XX-XX-XX.local where
KB-XX-XX-XX is the Host name of the unit that appears on the label on the side of
the unit. For example, if the unit Host name is KB-C5-6B-78, then the command line
is ssh kwikbit@KB-C5-6B-78.local. For the password prompt enter kwikbit.
● Management IP Address: Connect using the IPv4 IP address. The factory-assigned
IP address appears on a temporary label on the unit.
The optional Kwikbit Edge Controller’s management application automatically discovers all
connected K60c devices on the network and establishes a secure connection to each one
utilizing a security certificate provided by Kwikbit and customized by the customer. For
Kwikbit K60c User Guide
- 15 -
K60c User Guide
more information on the Kwikbit Edge Controller device and associated applications, please
refer to the Kwikbit Edge Controller User Manual.
The K60c system provides the following network management functions:
1. Device configuration information and status is displayed on the WebUI page
interface as shown above in Figure 2. When the mouse cursor is hovered over an
Ethernet Port or wireless connections icon, detailed information is displayed. In the
Wireless section, the list of wirelessly connected devices is displayed. The list of LAN
connected devices is displayed in the LAN Peers section. The WebUI of a connected
device is established by clicking on the device’s name.
2. Configuration Management. The system configuration section covers several
functional areas:
● Device
o Device location
o Device description
● Wired Network
o Device IP address assignment
Static address
▪
▪ DHCP – requires DHCP server
▪ Automatic Zero Configuration address assignment
o Management VLAN
o Ethernet port
▪
Enable / Disable
● Wireless Network
o Device role
o SSID
o Airlink passcode
o Channel frequency
o Preferred Hub (if device configured as Remote)
3. Administration Operations:
● Flash LEDs of the device – used to identify location of physically installed device
● Change administrator password of the device
● Upgrade device software
● Reboot the device
To reset the device to factory defaults:
● Insert the Reset Dongle (available separately) into Ethernet Port 2
● Cycle the power
● During power-up, observe the LED.
● Remove the Reset Dongle when the LED pattern indicates that the reset has been
triggered (refer to the LED Indicator Codes section of this document)
● The device is now operating at factory default settings
● The login password is “kwikbit”
Kwikbit K60c User Guide
- 16 -
K60c User Guide
8 Ethernet Bridge Support
Designed to seamlessly integrate into existing Ethernet networks, the K60c system is built
for Ethernet connectivity services and provides network functionality as a standard Layer 2
(L2) Transparent Bridge (IEEE 802.1d), whereby the K60c cluster (a cluster being one Hub
with its group of up to seven Remotes) is the bridge, and the Ethernet ports on the Hub and
associated Remotes are the ports of the bridge.
The embedded bridge functionality performs Media Access Control (MAC) address learning
(up to 4096 MAC addresses). This function allows the Hub to perform an optimal allocation
of radio resources by sending traffic to the Remote behind which the destination of that
traffic is located.
The K60c system allows network management traffic to be encapsulated in a dedicated
management VLAN and can transport standard Ethernet frames, including oversize frames
(up to 1600 bytes including the FCS).
9 Installation Planning
When unpacking K60c units during install, be sure to do the following for each unit:
● Locate the label on the unit casing that lists the Serial Number (SN) and Host name
of the unit
● Record the SN on your registration card for future reference
● Record the Host name for future reference when provisioning the system
After installation of the K60c, perform the tasks described in Chapter 12 “System
Provisioning”.
10 LED Indicator Codes
K60c is equipped with a single double color (red and green) LED indicator. The following are
the LED indication modes. The sequences indicate the LED state during each 150ms time
slot
● during boot up: solid red
● normal operation:
o no wireless link: repeat the sequence: green, off, off, green, off, off ...
o established wireless link:
▪ Hub: solid green
Kwikbit K60c User Guide
- 17 -
K60c User Guide
▪ Remote: signal quality from 1 blink for weakest to 5 blinks for the
strongest between pauses. Example: for link quality of 3 the repeat
sequence is: pause green green green
o repeat the sequence: red, off, red, off, red, off, off, off
● error condition:
● identify the unit
o repeat the sequence: red, green
● signal for reset to factory defaults:
o repeat the sequence: green, red, green, red, green, red, off, off
● restore factory defaults is in progress:
o repeat the sequence: red, off, red, off, off, off, green, off, green, off, off, off
11 Using the K60c Web User Interface (UI)
11.1 Requirements
The K60c embedded WebUI allows for direct configuration of both Hub and Remote units.
It is a standard web application that runs directly on the K60c unit and is accessible through
the default port for HTTPS (443) at URL https://<Host name of the unit>. Your browser will
display a warning stating that the connection is not secure. You may ignore the warning
and proceed connecting to the unit. To avoid the warning, go to the Kwikbit support
website, download the Kwikbit security certificate, and install it on your browser.
The recommended browsers for the K60c WebUI are:
● Google Chrome
● Safari
Operating System (OS) support for K60c WebUI:
● Windows
● Mac OS X
● Unix
● Linux
Note: With the exception of IE9, the K60c WebUI supports the most recent web browser
and OS versions.
Required basic K60c unit configuration tasks can be performed using the units WebUI;
however, the Kwikbit Edge Controller can be used to quickly and efficiently plan,
Kwikbit K60c User Guide
- 18 -
K60c User Guide
commission, configure and monitor small to large K60c networks. See the Edge Controller
User Guide for details.
11.2 K60c Web UI Page
The K60c WebUI is a single page that provides device status as well as configuration
options.
11.2.1 Logging In
Use your browser to connect to K60c device’s WebUI as described above. It is not necessary
to login to the system in order to view the WebUI page. You will then be prompted to login
once you click on any one of the configuration tabs if you do not have a security certificate
installed on your computer. The security certificate based authentication option is available
when utilizing an Edge Controller to manage the network.
The default username and password is as follows:
User Name:
Password:
kwikbit
kwikbit
The page remains read-only if you do not login to the system and only gives general system
information.
Kwikbit K60c User Guide
- 19 -
K60c User Guide
At the top of the WebUI screen, general node information including unit name, description,
and location is displayed. There are two network sections on the page, Wireless and LAN.
The Wireless section displays the connection SSID, the unit role (Hub or Remote) and all
current wireless connections. If the unit is a Hub, all currently linked Remotes will be
displayed under connections. If the unit is a Remote, only one connection to a Hub can be
listed. Each connection displays the connected unit name as well as graphical
representation of the signal quality of the connection. By clicking on the connected device’s
name, a browser page of that device is opened. By hovering over the signal quality graphic,
detailed signal level information is displayed. You can change SSID and unit Role
Kwikbit K60c User Guide
- 20 -
K60c User Guide
configuration by clicking on the tool icon in the section banner, assuming you are an
authorized user.
The LAN section displays the unit’s assigned IP address and the status of the Gigabit
Ethernet port. By hovering over the Ethernet port icon, detailed port status information is
displayed. The unit’s IP configuration can be changed by clicking on the tool icon in the
section banner.
The Device section displays and provides configuration capability for Device Location and
Device Description.
The LAN Peers section displays the names of all K60c units that are connected to the
current unit over a LAN connection. In most cases, these would be collocated units that
provide additional wireless connectivity from that location.
The Administration section displays the software and the hardware versions of the device
and includes controls to change user password, upgrade device software, flash device LEDs
for device identification, and to reboot the device.
12 Using the K60c Command Line Interface (CLI)
12.1 Requirements
The K60c CLI allows for direct configuration of both Hub and Remote units. To connect
using Command Line Interface from a Linux, Unix or MAC computer terminal window type
ssh kwikbit@KB-XX-XX-XX.local where KB-XX-XX-XX is the Host name of the unit that
appears on the label on the side of the unit. For example, if the unit Host name is
KB-C5-6B-78, then the command line is ssh kwikbit@KB-C5-6B-78.local. For the password
prompt enter kwikbit. You should receive a command prompt
12.2 K60c CLI commands
The K60c CLI provides device status as well as configuration options commands.
At the prompt type “?” for the list of commands and their operation.
13 System Provisioning
Network planning, installation procedure and commissioning are most efficiently
performed using the Kwikbit Edge Controller. In addition, the Edge Controller enables
centralized network operation view and management. Please see the Kwikbit Edge
Controller User Guide for detailed information.
Kwikbit K60c User Guide
- 21 -
If it is desired to provision a K60c network without the use of edge controller, the following
tasks associated with preparing a K60c system must be followed:
K60c User Guide
Initial system setup and IP configurations
1.
2. Setting units’ roles
3. Setting SSID and airlink connectivity passcode
4. Setting communication channel frequency
13.1 Initial System Setup and IP Configurations
All new K60c units shipped from the factory are identical with a default software
configuration loaded. You must connect to the management interface in order to configure
the following system management parameters:
1. Connect your computer directly to the unit with an Ethernet cable. Once connected,
open a browser on the computer and enter the IP address found on the unit’s label.
2. After successfully opening the WebUI page, the unit’s IP address can be changed by
clicking on the Wired Network section tool icon:
● When prompted for username, enter kwikbit for the username and kwikbit for
password.
● Select the desired address assignment protocol. If static address is selected,
enter the network mask and default gateway.
● Click Submit and the unit will reboot with the new address assignment. Your
browser will automatically reconnect and display the page.
3. Click on the Wireless section tool icon to configure wireless communication
parameters:
● Select the role of the unit. When configuring a PtP or PtMP communication
system, only one of the wirelessly connected devices may be configured with
a Hub role. The units connecting to the Hub wirelessly must be configured as
Remotes.
● Configure SSID, airlink passcode and channel frequency (not required on
remote). These parameters must match between the Hub and all wirelessly
connected Remotes in order to establish wireless communication.
● If a configured Remote can connect to multiple Hubs, you may want to set
the optimal Hub in the Preferred Hub field.
● There needs to be a Hub node configured with Network Root = enable.
Alternatively, each remote needs to be configured with “Preferred Hub”.
Lacking both of these will result in Remote nodes periodically scanning
attempting to locate the Root node.
● Click Submit to save changes.
Kwikbit K60c User Guide
- 22 -
K60c User Guide
4. Click on the tool icon in the Device section to configure the Location at which the
device will be physically installed and the description of the device. Click Submit.
In the Admin section, click on the second icon to change the management interface
password.
5.
The unit is now configured and ready to be installed.
Kwikbit K60c User Guide
- 23 -
14 Appendices
14.1 Glossary
K60c User Guide
DHCP Dynamic Host Configuration Protocol
DL
Downlink
DNS
Domain Name System
FCC
Federal Communications Commission
FTP
File Transfer Protocol
Gbps
Gigabits per second
GHz
Gigahertz
HU
Hub Unit
IEEE
ISED
Institute of Electrical and Electronics
Engineers
Innovation, Science, and Economic
Development Canada
L2
Layer 2
LAN
Local Area Network
LED
Light Emitting Diode
LoS
Line-of-Sight
MAC Media Access Control
Mbps Megabits per second
MCS
Modulation and Coding Scheme
MHz
Megahertz
NLoS
Non-Line-of-Sight
Kwikbit K60c User Guide
- 24 -
K60c User Guide
NMS
Network Management System
PC
Personal Computer
PtMP
Point-to-Multipoint
PtP
Point-to-Point
QAM
Quadrature Amplitude Modulation
RF
RU
Radio Frequency
Remote Unit
SSID
Service Set Identifier
TDD
Time Division Duplexing
UL
Uplink
VLAN
Virtual Local Area Network
VDC
Volts Direct Current
14.2 FCC Regulatory Statement
Any changes or modifications not expressly approved by Kwikbit Inc. could void the user’s
authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.
This device is not to be operated on aircraft except for the conditions listed in 47 CFR
§15.255 (b).
14.3 FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. A minimum of 30 centimeters (12 inches) of separation between the K60c
and all persons shall be maintained.
Kwikbit K60c User Guide
- 25 -
K60c User Guide
14.4 ISED Industry Canada Regulatory Statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired
operation of the device.
This device is not to be operated on aircraft except for the conditions listed in ISED RSS-210
Annex J.1.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage
susceptible
d'encompromettre le fonctionnement.
radioélectrique
le brouillage
subi, même
est
si
Cet appareil ne doit pas être utilisé à bord d'un avion, sauf dans les conditions énumérées
dans ISDE RSS-210, annexe J.1.
14.5 ISED Industry Canada Radiation Exposure Statement
IC Radiation Exposure Statement: This equipment complies with IC RSS-102
NOTE:
radiation exposure limits set forth for an uncontrolled environment. A minimum of 30
centimeters of separation between the K60c and all persons shall be maintained.
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour
un environnement non contrôlé. Un minimum de 30 centimètres de séparation entre le
K60c et toutes les personnes doit être maintenu.
Kwikbit K60c User Guide
- 26 -
1 | External Photo | External Photos | 484.42 KiB | February 09 2021 / August 09 2021 | delayed release |
1 | Label Location | ID Label/Location Info | 31.22 KiB | February 09 2021 / February 10 2021 |
SN: 697102KM20350001007KB-C6-03-A6:2 This device complies with part 15 of the FCC HN: KB-C6-03-A6 Rules. Operation is subject to the following MA: 70:88:6B:C6:03:A6 two conditions: (1) This device may not PN: 1900-6971-5611 cause harmful interference, and (2) this
: : device must accept any interference MN: K60c RV: 02 received, including interference that may FCC ID: 2AMPSK60C cause undesired operation. IC: 22992-K60C Kwikbit Made in USA VONICES SE] NNESIE)
1 | Confidential Letter | Cover Letter(s) | 46.78 KiB | February 09 2021 / February 10 2021 |
7801 E. Bush Lake Rd Suite 300 Minneapolis Minnesota United States 55439 Kwikbit Inc. Confidential Letter Date: 2021/2/2 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID2AMP5K60C To Whom It May Concern:
Long Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the Commissions Rules, we hereby respectfully request confidential treatment of information accompanying this application as outlined below:
Block Diagrams Schematics Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We understand that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Short Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the Commissions Rules, we hereby respectfully request short-term confidential treatment of information accompanying this application as outlined below until 180 days after the Grant Date of Equipment Authorization in order to ensure sensitive business information remains confidential until the actual marketing of the device:
External Photos Internal Photos Test Setup photos Users Manuals Respectfully, Applicants company name
: Kwikbit Inc. Applicants company address
: 7801 E. Bush Lake Rd Suite 300 Minneapolis Minnesota United States 55439 Signature
Name and Job Title
: Tim Blom / Principal Hardware Engineer E-Mail Tel Fax
tblom@kwikbit.com
: 507-521-0598
: N/A
1 | Power of Attorney Letter | Cover Letter(s) | 39.64 KiB | February 09 2021 / February 10 2021 |
Kwikbit Inc. 7801 E. Bush Lake Rd Suite 300 Minneapolis Minnesota United States 55439 Power of Attorney Date: 2021/2/2 I hereby have entrusted the following person to be a proxy regarding application for Type Address
: No.8, Lane 724, Bo-ai St., Jhubei City, HsinChu County 302, Taiwan, R.O.C. e-mail
: Leohuang@sporton.com.tw I am therefore responsible for the contents of the application. Dear Sir, Certification. Sporton International Inc. Name
: Leo Huang Job Title
: Manager FCC ID: 2AMP5K60C Respectfully, Applicants company name
: Kwikbit Inc. Applicants company address
: 7801 E. Bush Lake Rd Suite 300 Minneapolis Minnesota United States 55439 Signature
Name and Job Title
: Tim Blom / Principal Hardware Engineer E-Mail Tel Fax
tblom@kwikbit.com
: 507-521-0598
: N/A
1 | SDoC Attestation Letter | Attestation Statements | 38.85 KiB | February 09 2021 / February 10 2021 |
Kwikbit Inc. 7801 E. Bush Lake Rd Suite 300 Minneapolis Minnesota United States 55439 SDoC Attestation Letter Date: 2021/2/2 We Kwikbit Inc., as the grantee of this project (FCC ID: 2AMP5K60C / Brand Name: Kwikbit / Model No.: K60c), would like to declare that the composite portion has been authorized under the Supplier's Declaration of Conformity procedures (Sporton report No.: FD0O1617, FCC designation number: TW1096). The final product shall consequently comply with the FCC rule applied for SDoC Procedure. Respectfully, Applicants company name
: Kwikbit Inc. Applicants company address
: 7801 E. Bush Lake Rd Suite 300 Minneapolis Minnesota United States 55439 Signature
Name and Job Title
: Tim Blom / Principal Hardware Engineer E-Mail Tel Fax
tblom@kwikbit.com
: 507-521-0598
: N/A
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2021-02-10 | 58320 ~ 62640 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2021-02-10
|
||||
1 | Applicant's complete, legal business name |
Kwikbit Inc.
|
||||
1 | FCC Registration Number (FRN) |
0023885312
|
||||
1 | Physical Address |
7801 E. Bush Lake Rd Suite 300
|
||||
1 |
7801 E. Bush Lake Rd
|
|||||
1 |
Minneapolis, MN
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@timcoengr.com
|
||||
1 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AMP5
|
||||
1 | Equipment Product Code |
K60C
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
T**** B********
|
||||
1 | Title |
Principal Hardware Engineer
|
||||
1 | Telephone Number |
507-5********
|
||||
1 | Fax Number |
NA********
|
||||
1 |
t******@kwikbit.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 08/09/2021 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | 60 GHz Outdoor Distribution System | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Sporton International Inc.
|
||||
1 | Name |
A****** C****
|
||||
1 | Telephone Number |
+886-********
|
||||
1 | Fax Number |
+886-********
|
||||
1 |
a******@sporton.com.tw
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 58320.00000000 | 62640.00000000 | 0.0210000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC