Electric Vehicle AC Charger Installation Instructions USER MANUAL TABLE OF CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS ........................................... 2 2. PRODUCT INTRODUCTIONS .............................................................. 6 3. VERIFY CONTENTS ................................................................................ 8 4. GATHER TOOLS..................................................................................... 10 5. PLAN THE MOUNTING ........................................................................ 11 6. MOUNT THE CHARGING STATION ................................................ 13 7. WIRE THE CIRCUIT ............................................................................... 15 8. OPERATE YOUR DEVICE ................................................................... 16 9. LIGHT CODES ......................................................................................... 20 10. WARRANTY AND MAINTENANCE .................................................. 21 1 USER MANUAL I I WARNING & CAUTION 1. Important Safety Instructions 1.1 Overall Warnings & Cautions WARNING: To avoid fire, injury or death, carefully read and follow the instructions during installation, operation and maintenance.
- DO NOT put fingers into the electric vehicle connector.
- DO NOT use this product if the flexible power cord or EV cable is frayed, insulation-broken, or any other signs of damage.
- DO NOT use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication of damage.
- DO NOT remove cover or attempt to open the enclosure because of risk of electric shock. WARNING: This device should be supervised when used around children. WARNING: This device must be grounded. WARNING: To avoid a risk of fire or electric shock, do not use this device with an extension cord. WARNING: The suitability of the use of flexible cord in accordance with CE code, part I, rule 4-012, is to be determined by the local inspection authority. WARNING: To reduce the risk of fire, connect only to a circuit provided branch circuit over-current protection in accordance with the CSA C22.115 Canadian Electrical Code, Part 1 (Canada) or NOM-001-SEDE Electrical installations (utility) (Mexico) or ANSI / NFPA 70 National Electrical Code (USA). Circuit Breaker Options table Output Amperage (A) 16A 32A 40A 48A 70A 80A Circuit Breaker Options (A) 20A 40A 50A 60A 90A 100A 2 USER MANUAL WARNING & CAUTION 1.2 Installation Requirements WARNING: Disconnect electrical power prior to installing the charging station. WARNING: Be sure to preview the user manual and ensure local building and electrical codes are reviewed before installing the AC charger. WARNING: The AC charger should be installed by a qualified technician according to the user manual and local safety regulations. CAUTION: Use appropriate protection when connecting to the main power distribution cable. CAUTION: Type B, C or D breaker with the rating current for table should be installed in the upstream AC distribution box. CAUTION: The device shall be mounted at height between 2 feet and 4 feet from ground. CAUTION: Please keep the charger in a clean area with low humidity. Not recommended to be installed in coastal environments with high humidity or high dust. 1.3 Daily Maintenance CAUTION: Avoid moisture or water in the charger. If there is water or moisture ingress in the charger, it is necessary to immediately power off to avoid immediate danger, and notify the professionals to carry out maintenance before next use. CAUTION: Please use the charger properly. Do not hit or press hard on the enclosure. If it is damaged, please contact a professional technician. CAUTION: Avoid placing the charger near hot objects and at high temperature locations and away from dangerous substances such as flammable gases and corrosive materials. CAUTION: Do not put heavy objects on the charger to avoid danger. 3 USER MANUAL WARNING & CAUTION Consignes De Scurit Importantes 1.1 Avertissement & Mise En Garde Gnraux AVERTISSEMENT : Pour viter les risques dincendie, de blessure ou de mort, il faut lire et suivre soigneusement les instructions pendant linstallation, lutilisation et lentretien.
- Ne mettez pas les doigts dans le connecteur du vhicule lectrique.
- N'utilisez pas ce produit si le cordon d'alimentation flexible ou le cble EV est effiloch, isol ou prsentant tout autre signe de dommage.
- N'utilisez pas ce produit si le botier ou le connecteur EV est cass, fissur, ouvert ou montre toute autre indication de dommage. Ne retirez pas le couvercle et n'essayez pas d'ouvrir le botier en raison du risque de choc lectrique. AVERTISSEMENT : Cet appareil doit tre surveill lorsqu'il est utilis proximit d'enfants. AVERTISSEMENT : Cet appareil doit tre mis la terre. AVERTISSEMENT : Pour viter tout risque d'incendie ou de choc lectrique, n'utilisez pas cet appareil avec une rallonge lectrique. AVERTISSEMENT : L'adquation de l'utilisation du cordon flexible conformment au code ce, partie i, rgle 4-012, doit tre dtermine par l'autorit d'inspection locale comptente. AVERTISSEMENT : Pour rduire les risques d'incendie, ne connecter qu' un circuit protection contre les surintensits des circuits de drivation conformment la norme canadienne CSA C22.1-15 Code lectrique, partie 1 (Canada) ou NOM-001-SEDE Installations lectriques (Mexique) ou ANSI / NFPA 70 National Electrical Code
(tats-Unis). Circuit Breaker Options table Output Amperage (A) 16A 32A 40A 48A 70A 80A Circuit Breaker Options (A) 20A 40A 50A 60A 90A 100A 4 USER MANUAL WARNING & CAUTION 1.2 Exigence Avant Linstallation AVERTISSEMENT : Assurez-vous de consulter le manuel d'utilisation et assurez-vous que les codes locaux du btiment et de l'lectricit sont passs en revue avant d'installer le chargeur. AVERTISSEMENT : Dbranchez l'alimentation lectrique avant d'installer la station de charge. AVERTISSEMENT : Le chargeur CA doit tre install par un technicien qualifi conformment au manuel d'utilisation et aux rglementations de scurit locales. MISE EN GARDE : Utilisez une protection approprie lors de la connexion au cble de distribution d'alimentation principal. MISE EN GARDE : Un disjoncteur de type B, C ou D avec le courant nominal indiqu dans le tableau doit tre install dans le botier de distribution CA en amont. MISE EN GARDE : Cet appareil doit tre mont une hauteur entre 2 feet and 4 feet du sol. MISE EN GARDE : Veuillez conserver le chargeur dans un endroit propre et peu humide. Il nest pas recommand de l'installer dans des environnements ctiers forte humidit ou forte poussire 1.3 Entretien Quotidien MISE EN GARDE : vitez l'humidit ou l'eau dans le chargeur. En cas d'infiltration d'eau ou d'humidit dans le chargeur, il est ncessaire de l'teindre immdiatement pour viter tout danger immdiat et d'avertir le personnel professionnel d'effectuer l'entretien avant la prochaine utilisation. MISE EN GARDE : Veuillez utiliser le chargeur correctement. Ne frappez pas ou n'appuyez pas trop fort sur le botier. Si le botier est endommag, veuillez contacter un technicien professionnel. MISE EN GARDE : vitez de placer le chargeur proximit d'objets chauds et des endroits haute temprature et loin de substances dangereuses telles que des gaz inflammables et des matriaux corrosifs. MISE EN GARDE : Ne placez pas d'objets lourds sur le chargeur pour viter tout danger. 5 USER MANUAL 2. Product Introductions CAUTION: Avoid placing the charger near hot objects and at high temperature locations and away from dangerous substances such as flammable gases and corrosive materials. 2.1 Basic Interface 2.2 Basic Dimension 4.3 LCD Screen LED Light Indication RFID Card SAE J1772 AC Charging Connector Rear Notch Charging Cable Inlet LAN Cable Inlet AC Power Inlet Enclosure Wall-Mounted Bracket 6 USER MANUAL 2.3 Specifications Model Number Rated Input Voltage Rated Output Current AC Power Frequency JNT-EVC Version 208/240VAC 16/32/40/48/70/80A 50-60 Hz Input Protection UVP, OVP, RCD, SPD, Ground Fault Protection Output Protection Output Interface Storage Temperature Operation Temperature Relative Operation Humidity Relative Storage Humidity OCP, OTP, Control Pilot Fault Protection SAE J1772AC Charging Connector
-40F to 158F
-22F to 122F 95% RH Maximum 95% RH Maximum Network Connection LAN Version /Wi-Fi Version 10M / 100M Base-T 802.11 b/g/n GSM/3G/4G 18ft (25ft optional) Type 3 Wall-Mounted 6561ft Red, Green, Blue LED Internet Function Wi-Fi Function 3G/4G Function Cable Length Protection Level Installation Type Altitude Status Indication 7 USER MANUAL 3. Verify Contents Check the box to ensure you have this installation guide and these parts:
1 4 2 3 5 6 7 8 8 USER MANUAL No. Product Name Quantity Description 1 2 3 4 5 6 7 8 AC Charger User Manual Wall-Mounted Bracket M5 Anti-Theft Round Head Screws M6 Hexagonal Expansion Screws Allen Wrench Corrugated Mounting Template RFID Card (Optional) 1 1 1 2 4 1 1 2 With attached input power cable and output charging cable Please read carefully before use For mounting the charging station to the wall/structure For securing the charging station to the Mounting Bracket For installing the Mounting Bracket to the wall/structure For tightening M5 Screws For easy drilling of 4 screws holes for wall-mounted bracket. Control the charger start/stop 9 USER MANUAL 4. Gather Tools Tools required before installing the Wall-Mounted charger, gather the following tools:
1. Wire stripper 2. Adjustable Wrench 3. Voltmeter or digital multi-meter (for measuring AC voltage at the installation site) 4. Level 5. Pencil or marker 6. Drill 7. Phillips screwdriver 1 4 2 3 5 6 7 Note: The above tools are very important, please gather them all. 10 USER MANUAL 5. Plan The Mounting WARNING: In areas with frequent thunderstorms, add surge protection at the service panel for all circuits. Ensure all power and ground connections, especially those at the breaker and bus bar, are clean and tight. CAUTION: Not recommended to be installed in coastal environments with high humidity or high dust. STEP 1 Use screwdriver to loosen the 13 fixed screws on the rear of charger, then remove the front cover . STEP 2 Insert the SIM card according to the picture's instruction . 11 USER MANUAL STEP 3 Tighten 13 screws on the front cover after the front cover is put back, the recommended screw torque is 1.0 N.m (9.6 lbf.in) . STEP 4 Select the appropriate mounting location with electrical capacity:
I. Ensure the owner has chosen a mounting location that allows the charging cable to reach the cars charging port while still providing slack. II. The device must be anchored into mounting such as 3.14 x 5.11 stud or a solid wall. III. The device shall be mounted at height between 2 feet and 4 feet from ground. STEP 5 Drill 4 Screw Holes with a diameter of 0.32and a depth of 2.04 by using our mounting template. Please drill screw holes in the direction of the template arrow. 12 USER MANUAL 6. Mount the Charging Station STEP 1 Use 4 sets Hexagonal Expansion Screws to secure the wall-
mounted bracket on the wall. Then level the brackets. STEP 2 STEP3 Align the rear notch of charger with the Tighten two M5 anti-theft screws to wall-mounted bracket and fit the screw complete the installation. holes of the right and left side. 13 USER MANUAL STEP 4 Overall outlook picture after installation. Wall-mounted cable winding Optional cable hanging (optional accessory) 14 USER MANUAL 7. Wire The Circuit WARNING: This device must be grounded. Disconnect electrical power prior to installing the charging station. WARNING: Improper connection of the equipment-grounding conductor would result in a risk of electric shock. Check with a qualified electrician or serviceman if you are not sure whether the product is properly grounded. Do not modify the plug provided with the product if it doesnt fit the outlet, have a proper outlet installed by a qualified electrician. CAUTION: Use appropriate protection when connecting to the main power distribution cable. For safe use of electricity, please set circuit breaker protection in the input part of EV Charger The wiring is not complicated, just need to follow the instructions below:
Connect the L1 lead to the grid L1, connect the L2 lead to the grid L2, connect the PE lead to the grid PE. Circuit Breaker Options table Output Amperage (A) 16A 32A 40A 48A 70A 80A Circuit Breaker Options (A) 20A 40A 50A 60A 90A 100A 15 8. Operate Your Device USER MANUAL WARNING: This device should be supervised when used around children. CAUTION: Please use the charger properly. Do not hit or press hard on the enclosure. If the case is damaged, please contact a professional technician. CAUTION: Do not put heavy objects on the charger to avoid danger. 8.1 Operating Steps with Plug and Charge STEP 1 Standby Mode: After being powered on, the lights will be all on, blue light (READY), green light (CHARGE) and red light (FAULT). Then the blue light (READY) is constantly on in standby mode. 16 USER MANUAL STEP 2 Plug the Charging Connector:
Please plug the charging connector into the vehicle charging inlet. STEP 3 Charging: The green light (CHARGE) turns to flash automatically, charging is in process. If the red light (FAULT) is on, plug the vehicle connector again. If red light is still on, please refer to "Error and Warning Messages". STEP 4 Charging finished: When the charging is finished, the green light (CHARGE) is constantly on, pull out the charging connector. 17 8.2 Operating Steps with RFID (Optional) USER MANUAL CAUTION: Please keep your RFID card properly to avoid unnecessary loss. STEP 1 Standby Mode: After power-on, blue light
(READY), green light (CHARGE) and red light (FAULT) all on. The blue light (READY) is constantly on when in standby mode. STEP 2 Ready to charge:
Please plug the charging connector into the vehicle charging inlet. When the green light
(CHARGE) is constantly on, the user can swipe the RFID Card 18 USER MANUAL STEP 3 Swipe the RFID Card:
Swipe the RFID card first and plug in the charging connector within 120 seconds, otherwise you need to swipe the RFID card again. STEP 4 Charging: The green light (CHARGE) turns to flash automatically, charging is in process. If the red light (FAULT) is on, plug in the charging connector again. If red light is still on, please refer to "Error and Warning Messages". STEP 5 Charging finished:
When the charging is finished or swipe your RFID card, the green light (CHARGE) is constantly on. Please press the button on connector and pull out the charging connector 19 USER MANUAL 9. Light Codes 9.1 After Start UP Standby, waiting to plug in Solid Blue Waiting to charge, communicating with vehicle Solid Green Charging in progress Finished charging Fault Green Blinking Solid Green Solid Red 9.2 Error and Warning Messages Status Input OVP Input UVP Red Remark 1 flash followed by 3 sec pause Auto Recover 2 flashes followed by 3 sec pause Auto Recover Output OCP 3 flashes followed by 3 sec pause Auto Recover OTP 4 flashes followed by 3 sec pause Auto Recover RCD Abnormal 5 flashes followed by 3 sec pause Auto Recover Ground Fault 6 flashes followed by 3 sec pause Auto Recover Control Pilot Fault Flicker Auto Recover Emergency Fault Constantly Bright Rotate to Reset Emergency Button MCU Self-Test Fail Constantly Bright Contact Customer Service RCD Self-Test Fail Constantly Bright Contact Customer Service Relay Self-Test Fail Constantly Bright Contact Customer Service RCD Abnormal Stop Charging Constantly Bright Contact Customer Service Output OCP Stop Charging Constantly Bright Contact Customer Service OTP Stop Charging Constantly Bright Contact Customer Service 20 USER MANUAL 10. Warranty and Maintenance The warranty period for this charger is three years. During the warranty period for any malfunction under normal use according to the User Manual (to be determined by certified maintenance technicians of sellers), the product shall be repaired free of charge. Except for the following situations, the charger shall be subject to the above warranty terms:
1. The warranty certificate cannot be provided or the contents of the warranty certificate are modified or inconsistent with the label indication of the repaired product. 2. Those who are unable to provide valid proof of purchase. 3. Those who exceed the manufacturer's specified warranty period. 4. Those who damage the product due to not following the product service instruction for use, maintenance and storage. 5. Damage or malfunction caused by external object entering. 6. Unauthorized repair, disassembly or modification. 7. Damage caused by force majeure (such as lightning, excessive voltage, earthquake, fire, flood, etc.). 8. Malfunction and damage caused by other unavoidable external factors. Malfunction and damage caused by improper use of equipment, such as water or other solutions entering into the equipment. 9. Malfunction and damage caused by the grid power supply and voltage which is not specified for use with the charger equipment. The above guarantees shall be made solely, and no other express or implied warranties shall be made (including the implied warranties of merchant ability, particular and applicable reason- ableness and adaptability, etc.) whether in the contract, civil negligence, or other aspects, the Company shall not be responsible for any special, incidental or consequential damages. 21 USER MANUAL This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interfer-
ence to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. WIFI moduleContians FCC ID:2AC7Z-ESPWROOM32D FCC ID:QGH-ACEVC80 To satisfy FCC RF exposure requirements, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended ISED Regulatory Compliance This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR d Innovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitat ion est autorise aux deux conditions suivantes :
1) Lappareil ne doit pas produire de brouillage;
2) Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compr omettre le fonctionnement. This equipment complies with IC RSS102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Cet quipement est conforme aux limites d'exposition aux radiations IC CNR102 tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec une distance minimale de 20cm entre le radiateur et votre corps. 22