Single Pole (One location) or 3-Way (Multi-location) Incandescent Dimmer Cat. No. RZI6-1L, 600W (Lighted) Compatible with TM enabled products!
DI-000-RZI06-00A-X0 120VAC, 60Hz INSTALLATION INSTRUCTIONS WARNINGS AND CAUTIONS:
To be installed and/or used in accordance with appropriate electrical codes and regulations. To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-
If you are unsure about any part of these instructions, consult a qualified electrician. operated appliance. Use with incandescent or 120V halogen fixtures only. Vizia RF dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia RF remotes for multi-location dimming. Use only one (1) Vizia RF dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or Vizia RF controllers. The remote(s) will turn the light on at the brightness level selected at the dimmer. WARNINGS AND CAUTIONS:
Dimmer may not operate with dioded lamps (Sylvania Designer 16 or Philips PAR-16). Total minimum load must exceed 40W. Dimmer may feel warm to the touch during normal operation. Recommended minimum wall box depth is 2-1/2". Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture. Use this device only with copper or copper clad wire. With aluminum wire use only devices marked Tools needed to install your Dimmer:
Slotted/Phillips Screwdriver Pliers Cutters Electrical Tape Pencil Ruler Changing the color of your Dimmer:
Your Dimmer may include three color options. The Dimmer ships with the White frame attached. To change color of frame, proceed as follows:
Push in side at tab to release Line up tabs and press in side to attach Installing Dimmer by itself or with other devices:
If installing Dimmer in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-device application, proceed as follows:
MULTI-DEVICE APPLICATION:
In multi-dimmer installations, the reduction of the dimmers capacity is required. Refer to the chart for maximum load per dimmer. 1 3 4 2 Single-Pole 1. Line (Hot) 2. Neutral 3. Ground 4. Load Step 1 Step 2 OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON OFF OFF OFF OFF OFF OFF INSTALLING YOUR DIMMER NOTE: Use check boxes when Steps are completed. WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
Identifying your wiring application (most common):
NOTE: If the wiring in the wall box does not resemble any of these configurations, consult a qualified electrician. A CO/ALR or CU/AL. Step 3 Preparing and connecting wires:
This dimmer can be wired using side wire terminal screws or through backwire openings. Choose appropriate wire stripping specifications accordingly. B l ON ON ON ON ON ON 5/8"
(1.6 cm) Cut
(if necessary) P R E LI M I N 2. Neutral 3. Ground 4. First Traveler note color 5. Second Traveler note color NOTE: For matching remote w/LEDs installation, the First Traveler becomes Line Hot. Side Wire Connection Side wire terminals accept
#14 AWG solid copper wire only. 3-Way 1. Line or Load (See important straight (cut if necessary). instruction below) Step 4a to Step 4b. 3 4 5 2 1 B K 2 1 Terminal Screw marked Black (BK) Single-Pole Wiring Application:
Make sure that the ends of the wires from the wall box are Remove insulation from each wire in the wall box as shown. For Single-Pole Application, go to Step 4a. For 3-Way Coordinating Remote (no LEDs) Application, go Back Wire (either hole may be used) Back wire openings use #14-12 AWG solid copper wire only. MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE More than Two Devices 2 Devices Cat. No. RZI6 Single 600W 500W 400W IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and remote wall box. Terminal Screw marked Yellow/Red
(YL/RD) YL/RD R D 3 4 Terminal Screw marked Red (RD) Terminal Label:
Use Terminal for 3-Way or More Applications Only. For Single-Pole Applications, Do Not Remove This Label. R Y Step 4a contd Strip Gage
(measure bare wire here or use gage on back of the dimmer) Black Load White Dimmer BK Green Ground YL/RD RD Hot (Black) Black Use Terminal for 3-Way or More Applications Only. For Single-Pole Applications, Do Not Remove This Label. Line 120VAC, 60Hz Load White FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving Antenna. Connect the equipment into an outlet on a circuit different from that to which Increase the separation between the equipment and the receiver. the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Step 4b contd Coordinating Remote (no LEDs) Do not use for incandescent applications. BK WH Dimmer BK Hot (Black) Green Ground YL/RD RD Green Ground YL/RD RD Line 120VAC, 60Hz Neutral (White) Neutral (White) WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw. Line Hot wall box wire to terminal screw marked "BK". Load wall box wire to terminal screw marked "RD". Dimmer terminal screw marked "YL/RD" should have Red insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked
"YL/RD", use electrical tape to cover. Proceed to Step 5. Step 4b 3-Way Wiring with Coordinating Dimming or Switching Remote (no LEDs)
(Coordinating Dimming Remote Depicted) Coordinating Remote Dimmer B K YL/RD R D 1 3 4 5 2 Terminal Screw marked Black (BK) Terminal Screw marked Yellow/Red
(YL/RD) B K YL/RD R D 1 3 4 5 2 Terminal Screw marked Red (RD) WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. Green or bare copper wire in wall box to Green terminal screw. Line Hot (common) wall box wire identified (tagged) when removing old switch to terminal screw marked BK. First Traveler wall box wire to terminal screw marked RD (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked RD. Remove Red insulating label from terminal screw marked YL/RD. Second Traveler wall box wire to terminal screw marked YL/RD
(note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked YL/RD. WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft. Green or bare copper wire in wall box to Green terminal screw. Load wall box wire identified (tagged) when removing old switch to terminal screw marked BK. First Traveler wall box wire (note color as above) to terminal screw marked RD. This traveler from the remote must go to the terminal screw on the dimmer marked RD. Second Traveler wall box wire (note color as above) to terminal screw marked YL/RD. This traveler from the remote must go to the terminal screw on the dimmer marked YL/RD. Remote terminal screw marked "WH" should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked
"WH", use electrical tape to cover. Proceed to Step 5. B) While standing close to the module (approx. 2-5 ft), press the center button to <Include> device in the network. NOTE: Only one device may be included at a time. DO NOT put multiple devices into the Inclusion mode at any time. C) While the Programmer/Controller is in the Inclusion mode and the Locator LED is ON on the dimmer, push the push pad to turn ON the dimmer. The Programmer/Controller will verify inclusion and the locator LED will turn OFF on the dimmer. If the dimmer is flashing Amber while in the Inclusion mode, the Programmer/Controller is still trying to communicate with the dimmer. Wait until the device stops flashing,then press push pad. NOTE: If the locator LED on the dimmer turns solid Red while including, there has been a communication error. Refer to Troubleshooting section. D) The Primary Programmer/Controller wil assign a node ID number (Name) for this module. NOTE: This ID number (Name) will be stored in the controller library to be used for future reference. NOTE: You may name or edit the node of this device at this time. E) The dimmer is now installed in the network. NOTE: If a dimmer has been successfully Included in the network and the user tries to Include it again without first excluding it from the network, the module will retain the first node ID it had received and ignore the second. Step 5 Testing your Dimmer prior to mounting in wall box:
Position all wires to provide room in outlet wall box for device. Ensure that the word "TOP" is facing up on device strap. Partially screw in mounting screws in wall box mounting holes. NOTE: Dress wires with a bend as shown in diagram in order to relieve stress when mounting device. Restore power at circuit breaker or fuse. Press pad until locator light is OFF. Lights should turn ON. If lights do not turn ON, press the upper half of DIM/
BRIGHT bar until the lights brighten. If lights still do not turn ON, refer to the TROUBLESHOOTING section. Step 6 Including Scene Capable Dimmer into Z-Wave Network:
NOTES:
A) If using a non-Leviton Programmer/Controller, refer to the Programmer/Controller instruction sheet for Including a device. If using a Leviton Z-Wave Programmer/Controller, Cat. No. RZCPG, press the Menu button and scroll down to System Setup. Press the center button to select System Setup Menu. Press the center button to select Network. Programmer/Controller Cat. No. RZCPG Center Button RZCPG Programmer/Controller Menu Button NOTE: Remote must be in close proximity to dimmer when including in the network. Step 7 1 ON 2 ON 3 ON 4 ON OFF OFF OFF OFF Excluding Dimmer from Network:
NOTE: It is very important to accurately Exclude devices from the network when moving or removing a device from a Z-Wave network. This ensures that all information has been removed from your Primary Programmer/Controllers information table and is not counted on to be a part of the mesh network. System Setup. Press the center button to select System Setup Menu. Press the center button to select Network. B) While standing close to the module, press the center button to <Exclude> device from the network. C) While the Programmer/Controller is in the Exclusion mode and the locator LED is ON on the dimmer, press the push pad on the dimmer. The Programmer/Controller will verify Exclusion and the locator LED will turn OFF on the dimmer. If the dimmer is flashing Amber while in the Exlusion mode, the Programmer/Controller is still trying to communicate with the dimmer. Wait until the device stops flashing, then press the push pad. Factory Default:
If your dimmer is not responding, or you are unable to control it after you have tried to Include/Exclude it multiple times, it may be necessary to reset the dimmer to its original factory settings. To accomplish this, proceed as follows:
On the dimmer, engage he air-gap switch (refer to Operation section) and wait 5 seconds. Press push pad back into frame and hold push pad until the locator LED flashes Amber and turns solid Red. The dimmer is now reset. Once the dimmer is reset, it will be necessary to Re-Include it to a network before it can be used. Step 8 Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE. CAUTION: SETTING A DEVICE TO A FACTORY DEFAULT DOES NOT EXCLUDE THAT DEVICE FROM A NETWORK. THE EXCLUSION PROCEDURE MUST STILL BE FOLLOWED TO REMOVE THE DEVICE FROM THE PRIMARY CONTROLLERS INFORMATION TABLE. FAILURE TO DO SO MAY RESULT IN A SYSTEM THAT IS SLOW TO RESPOND, OR MAY FAIL TO RESPOND TO SOME DEVICES. P R E LI M I N OPERATION NOTE: The locator light will illuminate when the load is in the OFF position to facilitate access in the dark. NOTE: If using the dimmer in a 3-way application, the lights will turn ON at brightness set on dimmer's DIM/BRIGHT bar. The lighting can be controlled from either the dimmer or the remote location. Restore Power: Restore power at circuit breaker or fuse. Installation is complete. Installation may now be completed by tightening mounting screws into wall box. Attach wallplate. Step 9 DIM/BRIGHT Brightness Display LED Bar Push Pad (Default settings) Turn ON from OFF position:
Tap Lights turn ON to preset level. Press and Hold Lights turn ON to full bright. Turn OFF from ON position:
Tap Lights turn OFF. Press and Hold until lights DIM to lowest level and LED in LED Brightness Display starts to blink Lights remain ON for 10 seconds and then turn OFF. DIM/BRIGHT Bar BRIGHTEN:
Press upper half of DIM/BRIGHT Bar Lights brighten to desired level. DIM:
Press lower half of DIM/BRIGHT Bar Lights dim to desired level. If you continue to hold the lower half of the DIM/BRIGHT Bar, the lights will DIM to minimum level and then turn OFF. NOTE: When lights are OFF you can change the light level that the lights will turn ON to using the DIM/BRIGHT Bar. If there is a power outage, when the power is restored the lights will return to the last setting before the power interruption. Air-Gap Switch: On the dimmer only, engage the air-gap switch by gently pulling the bottom of the push pad until it lifts completely out of the frame and a click is heard and all LEDs are OFF (refer to Figure). This will cut power to the fixture to replace the bulb. After servicing is complete, push the push pad back for normal operation. R Y A Cleaning: Clean with a damp cloth. DO NOT use chemical cleaners. Gently lift bottom of push pad out ADVANCED PROGRAMMING FEATURES Mode 1 Set Minimum Brightness: Set the minimum brightness level that the lights can dim to prior to turning full OFF. Mode 2 Set Dim-Lock: Set the brightness level that the lights will turn on to regardless of the previous light level at which they were turned OFF. Mode 3 Set Fade Rate: Set the amount of time (in seconds) that the lights will have to turn ON or OFF. Fade rates can be set to one of five different settings. Advanced Features Summary Mode Description 1 2 3 Set Min. Brightness 1-50%
Set Dim-Lock Level 0-100%, 0=no lock 0 Select Fade Rate Range 1, 2, 3, 4, 5, 6 or 7 Preset #1 Default 25%
To Program:
NOTE: Have a flashlight handy if this dimmer controls the only light source in the room. 1. On the dimmer only, engage the air-gap switch by gently pulling the bottom of the push pad until it lifts completely out of the frame and a click is heard and all LEDs are OFF. 2. Press push pad back into frame and hold push pad for 7 seconds until the locator light and the top LED (LED 1) starts blinking. 3. Upon releasing the push pad, the locator light will continue to blink once per second indicating the dimmer is in Mode 1, Set Minimum Brightness mode. To change the current Minimum Brightness level from 1-50%, use the DIM/BRIGHT Bar. This setting will automatically be saved. 4. Tap the push pad to change to Mode 2, Set Dim-Lock Level mode. The locator light will blink twice per second. To change the current Set Dim-Lock level from 1-100%, use the DIM/BRIGHT Bar. If this feature is not desired, press and hold the lower half of the DIM/
BRIGHT Bar until no LED is lit. This setting will automatically be saved. 5. Tap the push pad to change to Mode 3, Set Fade Rate mode. The locator light will blink 3 times per second. To change the current Fade Rate, use the DIM/BRIGHT Bar to move the LED to the desired preset level. This setting will automatically be saved by tapping the push pad to exit programming mode. The LED Brightness Display is separated into 7 segments. Each LED represents a preset level with LED 1 (Preset 1) located at the top and LED 7 (Preset 7) located at the bottom. Refer to chart for settings and defaults. NOTE: The dimmer will exit program mode after 3 minutes of activity. Preset LED**
1*
2***
3 4 5 6 7 1 2 3 4 5 6 7 Fade Rate Presets Fade On Fade Off Approx. 1.5s from full off Approx. 3s from full on No Fade No Fade No Fade Approx. 3s from full on Approx. 0.5s from full off Approx. 3s from full on Approx. 0.5s from full off Approx. 1.5s from full on Approx. 1.5s from full off Approx. 5s from full on Approx. 1.5s from full off Approx. 10s from full on default
** LED #1 is located at the top
*** The press and hold feature for the 10 second delayed off is disabled in this mode. 1 2 3 4 5 6 7 LED Brightness Display TROUBLESHOOTING Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of dimmer and/or remote.
- Local switch, ON Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
- Confirm that the device is being supplied from a 120V, 60Hz AC source ONLY.
- Confirm that unit is programmed properly. Repeat TO INSTALL section to verify that it has been included in the Z-Wave network. Intermittent dimmer operation
- Minimum load is under 40W.
- Confirm that the Load being controlled does not exceed the 600W dimmer limit. Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft. For additional information, contact Levitons Techline at 1-800-824-3005 or visit Leviton's website at www.leviton.com DI-000-RZI06-00A-X0 U.S. & Foreign Patents Pending Copyright 2006 Leviton Manufacturing Co., Inc. All Rights Including Trade Dress Rights Reserved A) If using a Leviton Z-Wave Programmer/Controller, Cat. No. RZCPG, press the Menu button and scroll down to Push Pad Locator Light Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Levitons only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. LIMITED 5 YEAR WARRANTY AND EXCLUSIONS LEVITON INSTRUCTION SHEET/MANUAL LEVITON INSTRUCTION SHEET/MANUAL SPECIFICATIONS SPECIFICATIONS DI-000-RZI06-00A-X0 Black Helvetica 40 Lb. offset Paper size:
Paper size:
Overall size:
Overall size:
Final fold size:
Final fold size:
16.5" X 9"
2.75" X 3"
DOCUMENTATION DOCUMENTATION N/A KKC 1/23/06 FOLD SCHEME 16.5 Cat. No. 9.0 6 5 4 3 2 1 Cat. No. 2.75 Cat. No. 3.0 Final Fold Size Fold Line Panel Line
#'s = Fold Sequence