2015.04.14 ELS 2.13 Mono Graphic Type Manual Ver. 0.2 1. ELS Description & Key Function Remote control device provides customer with several functions as below Waking Tag up from sleep mode Updating new purchase image on Tag Deleting purchase image on Tag Returning a Tag to be factory settings Display Area Profile Hook Battery Cover Remo-con description LED : One of any buttons is pushed, green led turns on. After sending some data to a Tag, green led will turn off. Registration : Updating New Purchase Information on Tag Release : Deleting Purchase Information on Tag Reset : Returning a Tag to be factory settings Keep Alive : Waking Tag up from sleep mode Copyright. 2015. All Rights Reserved. 2. Registration Key Function To change purchase information on Tag, perform the following steps :
1. 2. Put remote controller near center of Tags display Press and hold Registration button on remote controller until green LED off
(about 0.5 seconds) 3. When Tag is successfully received Registration data from remote controller, Tags display will be changed to Connected for a few minutes. That means Tag hides purchase image to read Tags IEEE MAC address through the Barcode scanner 4. In NMS Client, download new purchase image to the Tag in registration status 5. When image downloading is finished successfully, Tags display will be changed to new purchase image Copyright. 2015. All Rights Reserved. 3. Release Key Function To release(delete) purchase information on Tag, perform the following steps :
1. 2. 3. Put remote controller near center of Tag display Press and hold Release button until green LED off (about 0.5 seconds) If Tag was received Reset command from remote controller, Tag will delete purchase information and Tags display will be changed to Ready 4. After step.3, Tag goes to deep sleep mode and doesnt communicate with gateway until receiving Keep Alive or Registration data from remote controller Copyright. 2015. All Rights Reserved. 4. Keep Alive Key Function Case 1 Case 2 Case 3 To wake Tag up from sleep mode, perform the following steps :
1. 2. 3. Put remote controller near center of Tag display Press and hold Keep Alive button until green LED off (about 0.5 seconds) Tag will wake up and goes to next step. Its depends on connection information with gateway case1) If this Tag wasnt connected with a gateway before sleep mode, go to 4-1 case2) If this Tag was connected with a gateway before sleep mode, go to 4-2 4-1. Searching gateway and goes to the next step. its depends on searching results case1) If Tag was successfully connected, Tags display will be changed to Ready case2) If Tag wasnt connected, Tags display(may be Ready) will be refreshed 4-2. Sending Keep Alive packet to gateway and Tag will go to sleep mode again Copyright. 2015. All Rights Reserved. 5. Reset Key Function To make a Tag to be factory reset status, perform the following steps :
1. 2. 3. Put remote controller near center of Tag display Press and hold Reset button until green LED off (about 0.5 seconds) If Tag was received Reset command from remote controller, Tag goes back to factory settings and Tags display will be changed to Ready 4. After step.3, Tag goes to deep sleep mode and doesnt communicate with gateway until receiving Keep Alive or Registration data from remote controller Copyright. 2015. All Rights Reserved. 6. Status Display Deep Sleep mode Connected to gateway Disconnected to gateway Image downloading fail Battery is dis-charged (to need changing battery) Copyright. 2015. All Rights Reserved. 6. Regulation Information INFORMATION TO THE USER This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modifications to the equipment not expressly approved by the party responsible for compliance could void users authority to operate the equipment. This appliance and its antenna must not be co-located or operation in conjunction with any other antenna or transmitter. A minimum separation distance of 20 must be maintained between the antenna and the person for this appliance to satisfy the RF exposure requirement Copyright. 2015. All Rights Reserved.