Confidential Preliminary-Subject to Change User manual Model Name: SmartTraxx go 1.1 By Locus Solutions December 22, 2015 Revision History Revision Date X1.00 12/22/15 Initial Release Description 2013 Locus Solutions Page 1 of 6 Confidential Preliminary-Subject to Change Scope This document is a user manual for the SmartTraxx go 1.1 monitoring temperature device. Description The SmartTraxx go 1.1 is a self integrated commercial grade monitoring temperature device that uses in the cold storages. SmartTraxx go 1.1 is optimized for reliability, cost and size. All antenna including GSM antenna are internal to the device. Data reporting can be initiated by a command center or by the device itself via GSM/GPRS, SMS or PDP pathways. The SmartTraxx go 1.1 is unique in that it is intrinsically expandable. A screw fastened expansion door secures SIM card access. The SmartTraxx go 1.1 has a embedded lithium battery, the battery has 1800mAh capacity . The SmartTraxx go 1.1 is based on chip level design. The application software executes on the base level Central Processing Unit (CPU) under direct Operating System (OS) control.This approach provides a much more reliable, lower power and faster response than module/processor architectures. Unlike in common module/processor based designs; the SmartTraxx go 1.1 design allows direct operating system access by the application, thus mitigating the need for a redundant external processor. For added monitoring temperature application ,a temperature sensor IC oversees the SmartTraxx go 1.1 system operation. The SmartTraxx go 1.1 Device can be provisioned for UDP and SMS data services for both application command and data transactions within the 850 & 1900 or 900 & 1800 MHz GSM bands. Network provisioning is done with standard SIM cards. A separate dedicated one wire UART port is provided for general use as well as development and programming support. A USB Port that is compliant with Version 2.0 of the USB standard for high speed operation is provided for upgrade/download the program. The power input, ground that are provided by the internal lithium battery that supports connection of a rechargeable battery. Over The Air (OTA) application firmware updates are supported through at TFTP connection to a server. The entire image can be updated using one simple command. This includes transient electrical noise and Electro Static Discharge (ESD). The SmartTraxx go 1.1 is a small yellow - white box with unremarkable features. Two LED status indicators are provided to verify correct installation and initial operation. A unique power management feature allows these LEDs to be extinguished once installation is verified to be correct. This feature reduces power. As with all monitoring temperature device , the SmartTraxx go 1.1 should be used in a Cold storages that it is a enclosed space . Double sided foam tape can be used to secure the surface not facing the sky if needed. Physical Attributes Figure 1 shows various views of the SmartTraxx go 1.1 Device and its critical physical features. 2013 Locus Solutions Page 2 of 6 Confidential Preliminary-Subject to Change Figure 1 SmartTraxx go 1.1 Physial Attributes 2013 Locus Solutions Page 3 of 6 Confidential Preliminary-Subject to Change CE Regulations:
Caution Risk of explosion if battery replaced aced by an incorrect type. Dispose of used batteries according to the instructions. Please make sure the temperature for device will not be higher than 55C The device is tested for typical body worn operation. The minimum distance between the user and/or any bystander and the radiating structure of the transmitter is 20cm. Complies with the essential requirements of Article 3 of the R&TTE 1999/5/EC Directive, if used for its intended use and that the following standards have been applied:
1. Health (Article 3.1(a) of the R&TTE Directive) EN 62311: 2008 2. Safety (Article 3.1(a) of the R&TTE Directive) Applied Standard(s):
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2: 2013 3. Electromagnetic compatibility (Article 3.1 (b) of the R&TTE Directive) Applied Standard(s):
EN 301 489-1 V1.9.2/-7 V1.3.1 4. Radio frequency spectrum usage (Article 3.2 of the R&TTE Directive) Applied Standard(s):
EN 301 511 V9.0.2 All the reports of the applied standards have the Positive Opinion of Notified Body:
PHONEIX TESTLAB, Knigswinkel 10 D-32825 Blomberg, Germany Identification mark: 0700 (Notified Body) CE The technical documentation relevant to the above equipment will be held at: Locus Solutions 2013 Locus Solutions Page 4 of 6 Confidential Preliminary-Subject to Change FCC Regulations:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Cet appareil est conforme aux dispositions de la partie 15 des rgles de la FCC et des normes CNR d'Industrie Canada sur les appareils radio exempts de licence. Son utilisation est assujettie aux deux conditions suivantes : (1) Cet appareil ne doit pas causer d'interfrence nuisible; et (2) cet appareil doit accepter toute interfrence reue, y compris l'interfrence qui pourrait causer un fonctionnement non dsir. Cet quipement a t test et jug conforme aux limites d'un appareil numrique de la Classe B, en vertu de la partie 15 des rgles de la FCC et de la NMB-003 canadienne. Ces limites sont conues pour fournir une protection raisonnable contre l'interfrence nuisible dans une installation rsidentielle. Cet quipement gnre, utilise et peut mettre de l'nergie radiofrquence et, s'il n'est pas install et utilis conformment aux instructions, peut causer une interfrence nuisible aux communications radio. Toutefois, il n'est pas garanti que l'interfrence ne se produira pas dans une installation particulire. Si cet quipement cause une interfrence nuisible la rception radio ou de programmes de tlvision, laquelle peut tre dtermine en teignant et en allumant l'quipement, l'usager est encourag essayer de corriger l'interfrence par l'une ou plusieurs des mesures suivantes. Rorientez ou relocalisez l'antenne de rception. Augmentez la sparation entre l'quipement et le receveur. Connectez l'quipement une prise sur un circuit diffrent de celui auquel de le receveur est connect. Consultez le vendeur ou un technicien radio/de tlvision pour obtenir de l'aide. La FCC ou Industrie Canada peut vous obliger arrter d'utiliser votre appareil si une telle interfrence ne peut pas tre limine. SmartTraxx go 1.1 n'a pas approuv les changements ou modifications apports cet appareil par l'usager. Tous les changements ou modifications apports peuvent entraner la rvocation de l'autorisation d'utilisation de l'appareil. RF Exposure Information This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) 2013 Locus Solutions Page 5 of 6 Confidential Preliminary-Subject to Change during normal operation. IC Notice This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. IC: 10124A-101006 IC Exposure Information This device complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the IC RSS-102 radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) during normal operation. Cet appareil est conforme aux limites d'exposition aux rayonnements de la IC CNR-102 dfinies pour un environnement non contrl. Afin d'viter la possibilit de dpasser les limites d'exposition aux frquences radio de la IC CNR-102, la proximit humaine l'antenne ne doit pas tre infrieure 20 cm (8 pouces) pendant le fonctionnement normal. 2013 Locus Solutions Page 6 of 6