Confidential Preliminary-Subject to Change User manual Model Name: GO Tracker 1.3 By Locus Solutions, LLC 05 ,22, 2017 Revision History Revisio n X1.00 Date 17/22/05 Initial Release Descriptio n 2013 Locus Solutions, LLC Page 1 of 6 Confidential Preliminary-Subject to Change Scope This document is a user manual for the GO Tracker 1.3 monitoring temperature device. Description The GO Tracker 1.3 is a self integrated commercial grade monitoring temperature device that uses in the cold storages. GO Tracker 1.3 is optimized for reliability, cost and size. All antenna including GSM antenna are internal to the device. Data reporting can be initiated by a command center or by the device itself via GSM/GPRS, SMS or PDP pathways. The GO Tracker 1.3 is unique in that it is intrinsically expandable. A screw fastened expansion door secures SIM card access. The GO Tracker 1.3 has a embedded lithium battery, the battery has 1800mAh capacity . The GO Tracker 1.3 is based on chip level design. The application software executes on the base level Central Processing Unit (CPU) under direct Operating System (OS) control.This approach provides a much more reliable, lower power and faster response than module/processor architectures. Unlike in common module/processor based designs; the GO Tracker 1.3 design allows direct operating system access by the application, thus mitigating the need for a redundant external processor. For added monitoring temperature application ,a temperature sensor IC oversees the GO Tracker 1.3 system operation. The GO Tracker 1.3 Device can be provisioned for UDP and SMS data services for both application command and data transactions within the 850 & 1900 or 900 & 1800 MHz GSM bands. Network provisioning is done with standard SIM cards. A separate dedicated one wire UART port is provided for general use as well as development and programming support. A USB Port that is compliant with Version 2.0 of the USB standard for high speed operation is provided for upgrade/download the program. The power input, ground that are provided by the of a rechargeable battery. internal lithium battery that supports connection Over The Air (OTA) application firmware updates are supported through at TFTP connection to a server. The entire image can be updated using one simple command. This includes transient electrical noise and Electro Static Discharge (ESD). The GO Tracker 1.3 is a small yellow - white box with unremarkable features. Two LED status indicators are provided to verify correct installation and initial operation. A unique power management feature allows these LEDs to be extinguished once installation is verified to be correct. This feature reduces power. As with all monitoring storages that it is a enclosed space . Double sided foam tape can be used to secure the surface not facing the sky if needed. temperature device , the GO Tracker 1.3 should be used in a Cold Physical Attributes Figure 1 shows various views of the GO Tracker 1.3 Device and its critical physical features. 2013 Locus Solutions, LLC Page 2 of 6 Confidential Preliminary-Subject to Change Figure 1 GO Tracker 1.3 Physial Attributes 2013 Locus Solutions, LLC Page 3 of 6 Confidential Preliminary-Subject to Change CE Regulations:
Caution Risk of explosion if battery replaced aced by an incorrect type. Dispose of used batteries according to the instructions. Please make sure the temperature for device will be from -10C to 45C . The manufacturer specified the maximum ambient temperature for use in charging mode of 40 C and for use in non-charge mode of 45 C. Adapter is not shipped with the product, but if used adaptor, need to select output rated of DC5V, 0.8A min and ambient 40 C minimum. The minimum distance between the user and/or any bystander and the radiating structure of the transmitter is 20cm. This radio equipment operates with the following frequency bands and maximum radio-
frequency power GSM90035dBm GSM180032dBm Complies with the essential requirements of Article 3 of the RED 2014/53/EU Directive, if used for its intended use and that the following standards have been applied:
1. Health (Article 3.1(a) of the RED Directive) EN 62311: 2008 2. Safety (Article 3.1(a) of the RED Directive) Applied Standard(s):
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 3. Electromagnetic compatibility (Article 3.1 (b) of the RED Directive) Applied Standard(s):
Draft EN 301 489-1 V2.2.0 (2017-03) Draft EN 301 489-52 V1.1.0 (2016-11) 4. Radio frequency spectrum usage (Article 3.2 of the RED Directive) Applied Standard(s):
EN 301 511 V9.0.2 All the reports of the applied standards have the Positive Opinion of Notified Body:
PHONEIX TESTLAB, Knigswinkel 10 D-32825 Blomberg, Germany
(Notified Body) CE Identification mark:
Uitbreidingsstraat 84, Berchem, Antwerpen, 2600, Belgium |
The technical documentation relevant to the above equipment will be held at: Locus Solutions, LLC FCC Regulations:
This device complies with part 15 of the following two conditions:
the FCC Rules. Operation is subject to
(1) This device may not cause harmful 2013 Locus Solutions, LLC Page 4 of 6 Confidential Preliminary-Subject to Change interference, and (2) this device must accept any interference received, interference that may cause undesired operation. including This device has been Class B designed residential frequency energy and, if not instructions, may cause harmful is no guarantee that equipment does cause can be determined by to to correct the try tested and found to comply with the limits for a digital device, pursuant to Part to provide reasonable protection against harmful 15 of the FCC Rules. These limits are interference in a installation. This equipment generates, uses and can radiated radio installed and used in accordance with the interference to radio communications. However, there interference will not occur harmful interference turning the equipment off and on, in a particular to radio or television the user installation If this reception, which is encouraged interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect which
-Consult the dealer or an experienced radio/TV technician for help. the receiver is connected. the equipment into an outlet on a circuit different from that to Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Cet appareil est conforme aux dispositions de la partie 15 des rgles de la FCC et des normes CNR d'Industrie Canada sur les appareils radio exempts de licence. Son utilisation est assujettie aux deux conditions suivantes : (1) Cet appareil ne doit pas causer d'interfrence nuisible; et (2) cet appareil doit accepter toute interfrence reue, y compris l'interfrence qui pourrait causer un fonctionnement non dsir. Cet quipement a ttestet jugconforme aux limites d'un appareil numrique de la Classe B, en vertu de la partie 15 des rgles de la FCC et de la NMB-003 canadienne. Ces limites sont conues pour fournir une protection raisonnable contre l'interfrence nuisible dans une installation rsidentielle. Cet quipement gnre, utilise et peut mettre de l'nergie radiofrquence et, s'il n'est pas installet utilisconformment aux instructions, peut causer une interfrence nuisible aux communications radio. Toutefois, il n'est pas garanti que l'interfrence ne se produira pas dans une installation particulire. Si cet quipement cause une interfrence nuisible la rception radio ou de programmes de tlvision, laquelle peut tre dtermine en teignant et en allumant l'quipement, l'usager est encouragessayer de corriger l'interfrence par l'une ou plusieurs des mesures suivantes. Rorientez ou relocalisez l'antenne de rception. Augmentez la sparation entre l'quipement et le receveur. Connectez l'quipement une prise sur un circuit diffrent de celui auquel de le receveur est connect. Consultez le vendeur ou un technicien radio/de tlvision pour obtenir de l'aide. La FCC ou Industrie Canada peut vous obliger arrter d'utiliser votre appareil si une telle interfrence ne peut pas tre limine. GO Tracker 1.3 n'a pas approuvles changements ou modifications apports cet appareil par l'usager. Tous les changements ou modifications apports peuvent entraner la rvocation de l'autorisation d'utilisation de l'appareil. 2013 Locus Solutions, LLC Page 5 of 6 Confidential Preliminary-Subject to Change RF Exposure Information This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) during normal operation. IC Notice This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. IC: 10124A-101007 IC Exposure Information This device complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the IC RSS-102 radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) during normal operation. Cet appareil est conforme aux limites d'exposition aux rayonnements de la IC CNR-102 dfinies pour un environnement non contrl. Afin d'viter la possibilitde dpasser les limites d'exposition aux frquences radio de la IC CNR-102, la proximithumaine l'antenne ne doit pas tre infrieure 20 cm
(8 pouces) pendant le fonctionnement normal. 2013 Locus Solutions, LLC Page 6 of 6