www.lodar.com Instructions for 92 Series IP Transmitters
(16 Function shown) STOP button switches off the receiver and the keypad function buttons LED Blinks when transmitter is active. ON when a transmitter button is pressed. Pulses while transmitting when battery is low. SAFETY FEATURE
!
The transmitter automatically transmits a STOP signal after 30 minutes; this de-activates the receiver and the transmitter. SET Button activates the Receiver and the keypad function buttons Function buttons 4 release screws for battery compartment at rear. 4 x AAA Alkaline batteries Effective working range up to a distance of 60 metres (200 feet) 92 Series To register Transmitters to the Receiver. Switch OFF or DISCONNECT the power to the Receiver and briefly PRESS the STOP button on one or both Transmitter(s). Switch ON or Reconnect the power to the Receiver. This opens a 20 second registration window and is indicated through flashing of the FAULT LED on the Receiver PCB.
!
PRESS & HOLD both SET and F1 for a MINIMUM of 5 SECONDS F1 F2 Immediately PRESS and HOLD both the Transmitters SET and F1 Buttons. Continue to hold BOTH BUTTONS for a MINIMUM of 5 seconds during this 20 second window. When the Transmitter is Registered the Fault LED on the Receiver will be illuminated for 3 seconds. Once completed, the buttons can then be released. TO REGISTER TWO TRANSMITTERS:
and F1 When the fault light starts to flash again, Buttons of the second Transmitter. Continue to hold BOTH BUTTONS for a MINIMUM of 5 seconds or until the SET LED comes on. Both your Transmitters will now operate the Receiver. immediately PRESS and HOLD both the Transmitter SET PRIORITY. Only one Transmitter can be active at any time. For the second Transmitter to work you have to turn off the first Transmitter. Once the second Transmitter is being used then that has priority and it has to be turned off before the first Transmitter can work again. If you have any problems please phone either your local Distributor or Lodar directly:-
UK +44(0)1922 613633. US +1-877- 257-1581. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 92TX.06E.A4