submitted | available | document details (if available) | source link |
---|---|---|---|
November 02 2014 | November 02 2014 | PowPak 0-10 V/PWM Dimming Module Japan Installation Sheet Part #041434a Adobe PDF Library 10.0.1 |
various | Manual PWM | Users Manual | 3.13 MiB | November 02 2014 |
PowPak | Installation Dimming Module with PWM / 0 10 V Part of the Energi TriPak Family 041434 Rev. A 01/2014 LMJ-5PWM-DV-B 120 / 277 V~ 50 / 60 Hz 5 A PWM Control: 12 V- 150 mA 0 10 V- Control: 10 V- 60 mA Important Notes: Please read before installing. For installation by a qualified electrician in acco dance with all local and national electrical codes. Note: Use copper conductors only. Check to see that the device type and rating is suitable for the application. DO NOT install if product has any visible damage. If moisture or condensation is evident, allow the product to dry completely before installation. Operate between 0 C and 40 C ambient. 0% to 90% humidity, non-condensing. For indoor use only. WARNING Shock Hazard. May result in serious injury or death. Turn off power at circuit breaker before installing the unit. PowPak Dimming Module Install in center of room to maximize RF coverage. Radio Powr SavrTM Occupancy Sensor 7 m max PowPak Dimming Module m 0 1 Pico Wireless Control 12 m h s i l g n E All Wireless Transmitters must be installed within 7 m of the PowPak Dimming Module. Default Functionality Occupancy Sensors Occupied: All lights 100%. Unoccupied: All lights off. Daylight Sensor All lights dim in response to daylight. Link Cal. Test Wireless Controls All lights 100%
On Favorite All lights 50%
Off All lights off PowPak | Programming ALL PROGRAMMING IS OPTIONAL Programming is not required for default functionality Set a favorite light level Set high-end and low-end trim for all fixtu es Set occupancy levels Set minimum light level for all fixtures Please consult individual component installation and programming guides for more details. FCC Information (LMJ- and ULMJ- only) This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation. Modifications not expressly approved by Lutron Electronics Co., Inc. could void the users authority to operate this equipment. NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Re-orient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Limited Warranty
(Lutron Asuka Company, Ltd., will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase, or mail to Lutron Asuka Company, Ltd., No. 16 Kowa Building, 4F 1-9-20, Akasaka, Minato-ku Tokyo 107-0052 Japan, postage pre-paid, or telephone Lutron Asuka Company, Ltd., at 03.5575.8411. This warranty is the sole express warranty, and the implied warranty of merchantability, as well as the implied warranty under the Japanese Civil Code
(kashi-tampo), is limited to one year from purchase. This warranty does not cover the cost of installation, removal, or reinstallation, or damage resulting from misuse, abuse, or improper or incorrect repair, or damages from improper wiring or installation. This warranty does not cover incidental, consequential, or any special damages. Lutron Asuka Companys liability on any claim for damages arising out of or in connection with the manufacture, sale, installation, delivery, or use of the unit shall never exceed the purchase price of the unit. Lutron, Pico, and PowPak are registered trademarks and Radio Powr Savr is a trademark of Lutron Electronics Co., Inc. 2013 Lutron Electronics Co., Inc. Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 U.S.A. Required Components For each system, ensure that you have:
One PowPak PWM Dimming Module Load Status LED Raise Toggle Lower
+
At least one Wireless Transmitter Need Help? visit www.lutron.com.jp or call Lutron Technical Support at 0120.083.417 At least one PWM or 0 10 V- Fluorescent Ballast or LED Driver Consult third-party fixtu es installation guide for fixtu e-specific wiring. Link Cal. Test
+
PowPak Dimming Module with PWM / 0 10 V- (1 maximum) Radio Powr SavrTM Occupancy/Vacancy Sensor
(6 maximum) Pico Wireless Control
(9 maximum) Radio Powr SavrTM Daylight Sensor
(1 maximum) Switches up to 5 A total. May be pre-installed in light fixtu e. Control line current - PWM: 150 mA max; 0-10 V-: 60 mA Start Here 1 Mount, Wire, and Install PWM/0 10 V-
Devices and Lighting Fixtures Consult third-party device installation guide Turn off power at circuit breaker before installing unit. A Connect mains wiring (switched hot, neutral) to each fixtu e. B Connect low-voltage control (+ and ) to each fixtu e. Green/Yellow Neutral Switched Hot
+
Violet Gray To additional fixtu es Fixture Earth NEU HOT M A N S I
+
l C a s s 2 Sample ballast shown 2 Install PowPak Dimming Module Wiring for 100 V~ applications:
Junction Box Suggested Installation Location:
Install in center of room. This ensures proper RF coverage of area. If installing unit inside a junction box please see Lutron P/N 369674. For more information: www.lutron.com/powpakrelay A PowPak Dimming Module can be installed in a junction box or marshalling box using the conduit nut (provided) or with mounting screws (not provided). Please consult local and national electric codes for proper installation. B Once installed, energize the PowPak Dimming Module. C Use the Toggle button to toggle between high-end and OFF to verify ballast wiring. D Use the Raise and Lower buttons to verify control wiring. Hot (Black) Neutral (White) Switched Hot (Yellow) Neutral (White) To fixtu es 21 mm Knockout Opening Conduit Nut 3 Associate Wireless Transmitters to PowPak Dimming Module Before beginning this step, make sure that there are no other PowPak modules being set up within the same building. It is possible that wireless transmitters from other systems can be incorrectly associated to this module. 4 Install Wireless Transmitters Note: Please consult individual component installation guides for information. A On PowPak Dimming Module, hold Toggle for 6 seconds until lights flash button The Load Status LED will begin flashing twice per second. B Hold the indicated button on each transmitter for 6seconds. Lights will flash to show that wireless transmitters have been associated. Link Cal. Test C On PowPak Dimming Module, hold Toggle button for 6 seconds to save association. Lights will flash and LED will quickly blink for 2seconds. Link Test 5 Calibrate Daylight Sensor Daylight Sensor will control all wired fixtu es equally. A Set lights in room to desired light level. B Press and hold Cal. for 6seconds. C Exit room for 5 minutes to Link complete calibration. Note: When calibration has completed, all lights will flash and begin daylighting. Multiple Daylight Rows
(OPTIONAL) For every row of daylighting a separate PowPakR Dimming Module must be used. For detailed setup refer to the tuning section of the Radio Powr SavrT Daylight Sensor installation guide. Test Cal. Select the PowPakR Dimming Module that you want to adjust by pressing the toggle button 7 Set Low-End and High-End Trim Low-End Trim A Enter low-end trim adjustment mode:
Press and hold Lower button Lights will flash high-low-high and LED will begin flashin for 12 seconds. B Adjust the low-end trim:
Notes Depending on the fixtu e manufacturer or load, low-end and high-end trim may need to be adjusted. Trim low-end to ensure a stable light level because some loads will flicker or d op out if trimmed too low. Be sure that you can turn on the lights to the low-end trim level without any abnormal operation. The factory default high-end trim will normally be sufficient for mos applications. Trim as desired. Use Raise button desired low-end (1to 45%). to adjust and set the lights to the and Lower button C Save the low-end trim:
Press and hold Toggle button for 6seconds to save setting. LED will begin flashing and then tu n solid to indicate new level has been saved. High-End Trim D Enter high-end trim adjustment mode:
for Press and hold Raise button 12seconds. Lights will flash high-low-high and LED will begin flashing E Adjust the high-end trim:
Use Raise button button to adjust and set the lights to the desired high-end (55to 100%). and Lower F Save the high-end trim:
Press and hold Toggle button for 6 seconds to save setting. LED will begin flashing and then tu n solid to indicate new level has been saved. 6 Set a Favorite Light Level For Pico Wireless Controls with a Favorite Button. A Adjust lights to desired level:
Use Raise button on Pico Wireless Control. or Lower button Raise Lower B Save favorite level:
Press and hold Favorite button for 6seconds. Favorite Reset Factory Defaults Note: In some instances, it may be necessary to reset the PowPak Dimming Module and connected devices back to factory default settings. Before beginning, make sure that all devices are connected and powered. A Triple-tap any button on the PowPak Dimming Module and hold until the LED begins to flash slowly; release button. B Within 3 seconds of the start of flashing, triple-tap the same button again and the LEDs will flash rapidly indicating that the unit has been reset to factory defaults. Note: Any associations or programming previously set up with the PowPak will be erased and will need to be re-programmed. Wiring for 200 V~ applications:
(requires a 2-pole input breaker) Junction Box Hot 1 (Black) Hot 2 (White)
+
Control line to fixtu es*
* Use 0.75 mm2 to 1.5mm2 solid wire only Switched Hot (Yellow) Hot 2 (White) To fixtu es 21 mm Knockout Opening Conduit Nut Daylight Override Pressing the raise button on an associated Pico Wireless Control will temporarily override daylighting. Daylight Re-Enable Daylighting will be re-enabled when one of the following occurs:
Two hours have passed since the override.*
ON, OFF, or Favorite button has been pressed on a PicoWireless Control. All associated Occupancy Sensors have reported unoccupied.
* Each time a daylighting override occurs, the two-hour timer is reset. 8 Set Minimum Light Level Certain applications (e.g., hallways), may require that the lights never turn off. For these areas, activate Minimum Light Level mode. A Enter minimum light level adjustment mode:
Press and hold Toggle button and Lower button for 12 seconds. Lights will flash hig -low-high and LED will begin flashing If lights stop flashing and go to high-end, the minimum light level is set to OFF
(default). If lights stop flashing and go to low-end, the minimum light level is ON and set to low-end. B Change the minimum light level:
Press Raise button light level to low-end. Press Lower button light level to OFF. to set minimum to set minimum C Save the minimum light level:
Press and hold Toggle button for 6 seconds. LED will quickly flash to indicate that new level has been saved.
+
Control line to fixtu es*
* Use 0.75 mm2 to 1.5mm2 solid wire only Supplied Terminal Information Strip Length: 9 mm Torque: 2 Nm 9 mm 9 Set Occupancy Light Levels Note: Unoccupied light level is always the minimum light level and cannot be adjusted. A Set desired occupancy light levels:
on the PowPak
/
on all
/
Use Raise/Lower buttons Dimming Module or Raise/Lower buttons associated Pico Wireless Controls. Note: If certain lights should be unaffected by occupancy, turn lights off using PicoR Wireless Control(s). B Save occupancy light levels:
Press and hold Test button for 6 seconds on any associated Radio Powr SavrTM Occupancy Sensor without a a button. Release when Sensor lens starts to flash Or, press and hold a button for 6 seconds on any associated Radio Powr SavrTM Occupancy Sensor. Release when Sensor lens starts to flash www.lutron.jp Troubleshooting Ballasts cannot be controlled locally from PowPak Dimming Module. Lights do not dim as expected. Lights do not respond to Wireless Transmitter(s). Wireless Transmitter(s) cannot be associated to PowPak Dimming Module. Ensure that the breaker(s) to the PowPak Dimming Module are energized. Ensure that the PowPak Dimming Module switched hot lead is wired to the ballast(s). Ensure that the PowPak Dimming Module 0 10 V control lines are wired to the ballast(s). Reset to factory defaults. Ensure that 0 10 V control lines are wired properly. Ensure that fixtu e does not require an inverted signal (10 0 V control) Ensure that the breaker(s) to the PowPak Dimming Module and ballasts are energized. Ensure that Wireless Transmitters are associated to the PowPak Dimming Module. Reset to factory defaults. The maximum number of Wireless Transmitters have been associated to the PowPak Dimming Module. To remove a previously set up Wireless Transmitter, tap a Wireless Transmitter button three times; on the third tap hold for three seconds and then tap three more times.
This product uses the FCC Data API but is not endorsed or certified by the FCC