WIRELESS GATEWAY
(Modbus/TCP (Ethernet), Modbus-RTU Transparent 900 MHz Band Wireless Device (Child device)) MODEL WL40EW2F BEFORE USE .... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-Systems Sales Office or representatives. PACKAGE INCLUDES:
Wireless gateway.................................................................(1) Antenna ...............................................................................(1) MODEL NO. Confirm Model No. marking on the product to be exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. For information on the introduction of wireless device, refer to the 900 MHz band wireless device users manual (EM-
9085). For information on the detailed setting, refer to the operat-
ing manual (NM-9080-B). For information on Modbus specification, refer to the Mod-
bus Protocol Reference Guide (EM-5650). These manuals are downloadable at M-Systems web site
(http://www.m-system.co.jp). POINTS OF CAUTION POWER INPUT RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below:
24V DC rating: 24V 10%, 90mA 12V DC rating: 12V 10%, 170mA GENERAL PRECAUTIONS Before you remove the unit or mount it, turn off the power supply for safety. ENVIRONMENT Indoor use. When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within -20 to +60C
(-4 to 140F) with relative humidity within 10 to 90% RH in order to ensure adequate life span and operation. Attach the antenna to the unit. Attachment and adjustment of sleeve antenna; Loosen the connector (See the top-right figure.), and rotate the antenna. Holding the antenna vertical, tighten the con-
nector by hand. Make sure to fix the antenna firmly. Connector Attachment of rooftop antenna; There is a magnet on the bottom face which allows you to attach the antenna on a metal box and such. To obtain optimum performance from the antenna, attach on a metal plate (recommended dimension: 500 mm 500 mm or more). However, in the case of connecting FE1 to a metal plate, the isolation be-
tween FE1 and antenna connector will be lost. Tighten the connector with a specified torque (0.9 Nm). As a guide, finger-tighten it until the connector stops, and then rotate it 10 to 15 degrees with a wrench. Do not force the cable to bend less than acceptable radius of 3 cm. Using 7.5 m coaxial cable (model: CX-SAC0SAD0Q0750)
(OKI) for extension decreases transmission distance. WIRING Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. Use a shielded twisted pair (STP) cable as a LAN cable. AND .... The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet. CAUTION REGARDING RADIO FREQUENCY FCC NOTICE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, in-
cluding interference that may cause undesired operation. FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the users au-
thority to operate the equipment. EM-9080-A P. 1 / 8 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jpINSTRUCTION MANUAL FCC RF EXPOSURE INFORMATION This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guide-
lines. This equipment should be installed and operated keeping the radiator at least 20 cm or more away from persons body. Contains FCC ID: 2AKGW-1TD3016A1 FCC ID : 2AOTF-0000001 NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accord-
ance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to cor-
rect the interference at his own expense. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. COMPONENT IDENTIFICATION
FRONT VIEW Status Indicator LED Antenna Connector Maintenance Connector Power 920Link 920Run 24V 0V NC NC FE1 Link Link100 Network Status Indicator LED CFG Ethernet RJ-45 Modular jack IP Reset Reset Switch Connector for Power Input *
* Power input defers depending on the power input code you select. STATUS INDICATOR LED STATUS ID Power 920Link 920Run ON Blinking OFF ON 0.5 Hz blinking OFF ON COLOR Green Green Green Green Green FUNCTION Power is on. Reset switch is on. Power is off, or device error occurring. 900 MHz band wireless: operating 900 MHz band wireless: starting up 900 MHz band wireless: stopping 900 MHz band wireless: normal communication with child device NETWORK STATUS INDICATOR LED ID Link Link100 STATUS ON Blinking OFF ON OFF COLOR Green Green FUNCTION Linking via 10BASE or 100BASE Sending / Receiving data No link Linking via 100BASE Linking via 10BASE or no link RESET SW Press and hold the SW for two seconds or more, so that Power LED blinks and the existing settings are initialized to the facto-
ry settings. Release the SW after confirming the power LED is blinking, so that the initialization starts and the unit reboots. Use this procedure if you are not sure of IP address or other settings. EM-9080-A P. 2 / 8 WL40EW2F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp TERMINAL ASSIGNMENTS Connectors for power input Unit side connector: MSTBV2,5/5-GF-5,08AU (Phoenix Contact) Cable side connector: TFKC2,5/5-STF-5,08AU (Phoenix Contact) Power input code: R (24 V DC) Power input code: S (12 V DC) 24V 0V NC NC FE1 ID 24V 0V NC NC FE1 FUNCTION Power input 24 V Power input 0 V Not used Not used Power input earth 12V 0V NC NC FE1 ID 12V 0V NC NC FE1 FUNCTION Power input 12 V Power input 0 V Not used Not used Power input earth EM-9080-A P. 3 / 8 WL40EW2F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp WEB BROWSER SETTING With web browser, settings shown below are available. Refer to the operating manual of EM-9080-B for detailed operation. TCP / IP SETTING ITEM IP address Subnet mask Default gateway MODBUS / TCP SETTING ITEM Port Modbus exception response Communication timeout WIRELESS SETTING ITEM PAN ID (group number) Radio channel number Network name Encryption key Prefix Transmitter power output Device type in a network, Number of devices in a network Set network quality Network join mode Packet filtering Filter timeout on polling Setting mode of short address 920Run timeout Retry times before route switching Short address list setting MAC address list setting Connection refusal list setting SETTING RANGE 1.0.0.0 223.255.255.255 224.0.0.0 255.255.255.255 0.0.0.0 255.255.255.255 DEFAULT 192.168.0.1 255.255.255.0 0.0.0.0 SETTING RANGE 1 65535 Not return 06 (BUSY), 0B (ERROR) /
Return 06 (BUSY), 0B (ERROR) 1 60 (min.) SETTING RANGE 0000 FFFE (hexadecimal, 4 digits) 1 43ch English one-byte characters within 16 characters
(one-byte space, -, _, ., @ are usable.) 0000...0 FFFF...F
(hexadecimal, 32 digits) 2000:0000:0000:0000 3FFF:FFFF:FFFF:FFFF 0.16mW / 1mW / 20mW Child (fixed), 1 to 30 devices /
Child (fixed), 31 to 60 devices /
Child (fixed), 61 to 100 devices /
Child (fixed) + child (moving) Standard (recommended) /
Frequency of route switching and delay (higher) /
Frequency of route switching and delay (highest) V3-compatible mode / Fast join mode None / Yes (polling type) 1.0 60.0 (sec.) Range mode: 1 device (max. multi drop number) Range mode: 1 to 4 devices (max. multi drop number) Range mode: 1 to 8 devices (max. multi drop number) Range mode: 1 to 16 devices (max. multi drop number) Range mode: 1 to 31 devices (max. multi drop number) List mode 0.0 3200.0 (sec.) Once / Twice / Three times Short address MAC address MAC address DEFAULT 502 Return 06 (BUSY), 0B (ERROR) 1 (min.) DEFAULT 0000 1ch MH920 0000...0 2000:0000:0000:0000 20mW Child (fixed), 1 to 30 devices Standard (recommended) V3-compatible mode Yes (polling type) 4.0 (sec.) List mode 5.0 (sec.) Three times Note: For version confirmation of communication module, refer to the operating manual of EM-9080-B for detailed operation. EM-9080-A P. 4 / 8 WL40EW2F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp INSTALLATION DIN RAIL MOUNTING A) Hang the upper hook at the back of the unit on the DIN rail. B) Push the lower part of the unit to fit in the DIN rail. DEMOUNTING A) Pull down the DIN rail adaptor using a minus screw-
driver. B) Pull out the lower part of the unit. C) Remove the upper part from the DIN rail. B B A C A EM-9080-A P. 5 / 8 WL40EW2F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp TERMINAL CONNECTIONS Connect the unit as in the diagram below. EXTERNAL DIMENSIONS unit: mm (inch) With sleeve antenna
[R165 (6.50)]
]
) 4 2
. 0 1
(
0 6 2
[
) 3 1
. 4
(
5 0 1
) 0 2
.
(
5
]
) 0 1
. 6
(
5 5 1
[
DIN RAIL 35mm wide 60 (2.36) 45 (1.77) 107 (4.21) 3 (.12) With rooftop antenna
[200 (7.87)]
3 (.12) 1.2 (.05)
) 5 1
. 3
(
0
)8 2 4
. 1
(
6 3 8 (.31) Hex. 27
(1.06) approx. 2500 (98.4) DIN RAIL 35mm wide 20
(.79) 107 (4.21) 3 (.12) EM-9080-A P. 6 / 8 WL40EW2F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp CONNECTION DIAGRAM Antenna Connector RJ-45 Modular Jack To Other Ethernet Devices Maintenance Connector USB Connector Power Input 24V*
0V NC NC FE1
* Power input defers depending on the power input code you select. WIRING INSTRUCTIONS TENSION CLAMP (FRONT TWIN CONNECTION) FOR POWER INPUT Applicable wire size: 0.2 to 2.5 mm2 Stripped length: 10 mm Recommended terminals:
AI0,25-10YE 0.25 mm2 (Phoenix Contact) AI0,34-10TQ 0.34 mm2 (Phoenix Contact) AI0,5-10WH 0.5 mm2 (Phoenix Contact) AI0,75-10GY 0.75 mm2 (Phoenix Contact) AI1-10RD 1.0 mm2 (Phoenix Contact) AI1,5-10BK 1.5 mm2 (Phoenix Contact) AI2,5-10BU 2.5 mm2 (Phoenix Contact) CONFIRMING ETHERNET CONNECTION PREPARATION FOR NETWORK CONNECTION To configure the settings for the device WL40EW2F via a network, a Windows PC, which can be connected to the network, is required. Confirm the settings of destinations such as the PC. 1) Connect the device and the PC with a LAN cable (STP cable). 2) Set PCs IP address 192.168.0.xxx which is not the same as the device. (example: 192.168.0.10) Set subnet mask 255.255.255.0. (Factory default IP address of the device is 192.168.0.1.) If this is the first-time connection, enter the factory default IP address as below. http://192.168.0.1./
SETTING FOR THE DEVICE 1) Activate web browser, and enter the IP address of the device following http:// in the address bar. Web browser (recommended): Microsoft Internet Explorer 11 or more 2) Enter user name and password. 3) For various settings, refer to the users manual (EM-9080-B) for detailed operation. admin as user name and admin as password are designated for the first time connection. CONNECTION TO NETWORK When wiring is correct, LED of LINK or LINK100 is ON or blinks. EM-9080-A P. 7 / 8 WL40EW2F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp CHECK FOR WL40EW2F CONNECTION Open Command Prompt in Windows, and enter ping command as follows:
C: WINDOWS > ping ***.***.***.***
(***.***.***.***: Enter IP address in decimal.) ping ***.***.***.*** with 32 bytes of data:
Reply from ***.***.***.*** : bytes=32 time < 10ms TTL = 64 Reply from ***.***.***.*** : bytes=32 time < 10ms TTL = 64 Reply from ***.***.***.*** : bytes=32 time < 10ms TTL = 64 Reply from ***.***.***.*** : bytes=32 time < 10ms TTL = 64 Ping statistics for ***.***.***.***
Packets : Sent = 4, Received = 4, Lost = 0 (0% loss) Replies in case of normal connection are as shown above. If the connection cannot be established normally due to e.g. wrong IP address, other replies such as timeout will be received. MODBUS FUNCTION CODE Modbus function codes are shown below. DATA AND CONTROL FUNCTIONS CODE 01 02 03 04 05 06 15 16 NAME Read Coil Status Read Input Status Read Holding Registers Read Input Registers Force Single Coil Preset Single Registers Force Multiple Coils Preset Multiple Registers EXCEPTION CODES Digital output from the slave (read/write) Status of digital inputs to the slave (read only) General purpose register within the slave (read/write) Collected data from the field by the slave (read only) Digital output from the slave (read/write) General purpose register within the slave (read/write) Digital output from the slave (read/write) General purpose register within the slave (read/write) CODE 06 11 NAME Slave Device Busy Gateway Target Device Failed To Respond Response from 900 MHz band wireless device (child) is error, or response Devices Modbus/TCP request queue is full. timeout occurred. Note: When 900 MHz band wireless device (child) returns an exception code other than the above, the exception code is directly transmitted to upper devices. LIGHTNING SURGE PROTECTION M-System offers a series of lightning surge protector for protection against induced lightning surges. Please contact M-System to choose appropriate models. EM-9080-A P. 8 / 8 WL40EW2F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp