WIRELESS TOWER LIGHT
(small size, 60 mm dia., Modbus-RTU transparent 900MHz band wireless device (child), 1 - 5 layers) MODEL IT60SW6F How to change antenna angle: Rotate the antenna after loosening the connector nut (refer to the next drawing). Tighten the nut with torque (0.98 Nm) while holding the antenna pointing to the intended direction. Otherwise, tight manually the nut, and assure it turning 10 to 15 more with a wrench. Connector Nut INGRESS PROTECTION (IP65) The IP code is conformable when the unit is mounted ver-
tically, antenna is installed and the control panel cover is locked. The compartment, where connectors are located, is not protected. When opening the control panel cover, avoid humidity and dust penetration. Dry and clean it if condensation is formed, and close the cover locking tightly. Install the antenna and tighten the connector nut tightly. In order to protect ingress of water or dust into the bot-
tom compartment, mount the unit on the flat plane, and be sure that the gasket does not roll back or dust is not on the gasket. WIRING Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. Cables to the unit must be wired indoor. AND .... The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet. BEFORE USE .... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-Systems Sales Office or representatives. PACKAGE INCLUDES:
Tower Light .........................................................................(1) Antenna ...............................................................................(1) MODEL NO. Confirm Model No. marking on the product to be exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. For information on the introduction of wireless device, refer to the 900 MHz band wireless device operating manual
(EM-9085-B). For information on Modbus specification, refer to the Mod-
bus Protocol Reference Guide (EM-5650). These manuals are downloadable at M-Systems web site
(http://www.m-system.co.jp). POINTS OF CAUTION POWER INPUT RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below:
24 V DC rating: 24 V 10%, approx. 7W GENERAL PRECAUTIONS Before you remove the unit or mount it, turn off the power supply and input signal for safety. The unit must not be subjected to external force. Do not rub the unit with organic solvent such as paint thinner. ENVIRONMENT Indoor use. Attach the antenna to the unit. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within -10 to +55C
(14 to 131F) with relative humidity within 10 to 90% RH in order to ensure adequate life span and operation. Mount the unit on a flat and robust plate. Lamps are omnidirectional. The buzzer sound is directional in front of the unit. This unit communicates by radio waves. Do not install the unit where it could be exposed to radio waves obstacles or strong electric fields. EM-2436 P. 1 / 8 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jpINSTRUCTION MANUALPATLABOR CAUTION REGARDING RADIO FREQUENCY FCC NOTICE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. FCC RF EXPOSURE INFORMATION This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines. This equipment should be installed and operated keeping the radiator at least 20 cm or more away from persons body. FCC ID : 2AOTF-0000007 (24V DC) Contains FCC ID: 2AKGW-1TD3016A1 EM-2436 P. 2 / 8 IT60SW6F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp COMPONENT IDENTIFICATION
FRONT VIEW (with the cover open)
BOTTOM VIEW Terminator SW RS-485 Connector FRONT ON Power SD 920Link 920ERR Run RD 920Run Mode Antenna 54 6 2 3 1 0 9 7 8 54 6 2 3 1 0 9 7 8 54 6 2 3 1 0 9 7 8 Lamp 1 Lamp 2 Lamp 3 Lamp 4 Lamp 5 Status Indicator LED Operating Mode Setting DIP SW Connector for Maintenance/Configurator Buzzer Aperture Gasket TERMINAL ASSIGNMENT Connector for Power Supply Unit side connector: MC1,5/5-GF-3,5 (Phoenix Contact) Cable side connector: FMC1,5/5-STF-3,5 (Phoenix Contact) DA DB DG SLD FE ID DA DB DG SLD FE FUNCTION DA DB DG Shield Functional earth STATUS INDICATOR LED ID Power COLOR Green Run Green SD Green RD Green 920Link Green 920Run Green 920ERR Red FUNCTION On when power is supplied. Blinks when the IP Reset SW is on. Off when power is not supplied or an abnormality occurs in the unit. On when Modbus communication is in normal status. Off at Modbus communication error or during no Modbus communication. On in sending data via RS-485 On in receiving data via RS-485 On when wireless link is working. Blinks with 0.5 Hz in establishing wire-
less link. Off when wireless link stops working. On when wireless communication with child device is in normal status. Off at a wireless communication error or during no communication. On when there is no detour route. Blinks at network authentication failure. Off in normal status. OPERATING MODE
(*) Factory setting Lamp Blinking Frequency: Mode-1 Mode-1 OFF ON LAMP BLINKING FREQUENCY Approx. 2 Hz (*) Approx. 10 Hz Buzzer Intermittent Frequency: Mode-2 Mode-2 OFF ON BUZZER INTERMITTENT FREQUENCY Approx. 2 Hz (*) Approx. 10 Hz Buzzer Volume: Mode-3, Mode-4 Mode-3 Mode-4 BUZZER VOLUME OFF OFF ON ON OFF ON OFF ON Quiet (*) Middle Loud Maximum Output at the Loss of Communication: Mode-6 Mode-6 OFF ON OUTPUT AT THE LOSS OF COMMUNICATION Reset the output (turned off) (*) Hold the output (maintains the last data received normally) Available for Modbus communication. Output Logic Reverse: Mode-7 Mode-7 OFF ON OUTPUT LOGIC REVERSE Non-inverted (*) Inverted Available for discrete input. Not available with blink (BLINK) or intermittence (BUZZ-
ER2), be sure to turn it off. Input Select: Mode-8 Mode-8 OFF ON INPUT SELECT Modbus/TCP (*) Discrete input Selects the input signal of lamp and buzzer control. Note: Be sure to set unused Mode-5 to OFF. TERMINATOR To enable the terminator, turn ON the terminator SW. To disable the terminator, turn OFF the terminator SW.
(Factory set to OFF) EM-2436 P. 3 / 8 IT60SW6F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp CONFIGURATOR SOFTWARE SETTING With configurator software, settings shown below are available. Refer to the software manual of ITCFG for detailed operation. WIRELESS SETTING ITEM Preferred PAN ID (group number) Radio channel number Short address Network name Encryption key Transmitter power output Low-speed moving mode Device type in a network, Number of devices in a network Set network quality Network join mode Fixed route Destination short address Temporary detour Packet filtering Filter timeout on polling 920Run timeout Modbus node address Retry times before route switching SETTING RANGE 0000 FFFE (hexadecimal, 4 digits) 1 43 (selectable up to 10 channels) 0000 FFFD (hexadecimal, 4 digits) English one-byte characters within 16 characters
(one-byte space, - , _ , . , @ are usable.) 0000...0 FFFF...F
(hexadecimal, 32 digits) 0.16 mW / 1 mW / 20 mW No / Yes Child (fixed), 1 to 30 devices /
Child (fixed), 31 to 60 devices /
Child (fixed), 61 to 100 devices /
Child (fixed) + child (moving) Standard (recommended) /
Frequency of route switching and delay (higher) /
Frequency of route switching and delay (highest) V3-compatible mode / Fast join mode No / Yes 0000 FFFD (hexadecimal, 4 digits) No / Yes None / Yes (polling type) 1.0 60.0 (sec.) 1.0 60.0 (sec.) 1 247 Once / Twice / Three times DEFAULT 0000 None 0000 Blank 0000...0 20 mW No Child (fixed), 1 to 30 devices Standard (recommended) V3-compatible mode No 0000 Yes Yes (polling type) 1.0 (sec.) 3.0 (sec.) 1 Three times Note: For version confirmation of communication module, refer to the software manual of ITCFG. MODBUS SETTING ITEM Transfer rate Parity bit Stop bit SETTING RANGE 38400 / 19200 / 9600 / 4800 bps Odd / Even / None 1 bit / 2 bits DEFAULT 38400 bps Odd 1 bit EM-2436 P. 4 / 8 IT60SW6F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp A 192 224 256 288 320 352 Lamp Layers 0 1 2 3 4 5 R 1 6 5
*1. Consult M-System for other bolt length. TERMINAL CONNECTIONS Connect the unit as in the diagram below. EXTERNAL DIMENSIONS unit: mm 601.5dia. 4 A
*
s h t g n e l 6 1 3 Bolts and Nuts (M4) Control Panel Cover Antenna
) 5 8
(
Approx. 1500
(60) 43 1.5 dia.
(30 dia.) Lead wires MOUNTING REQUIREMENTS unit: mm W irin g H ole 3 0 dia.*
43 dia. 3 Holes (5 dia.) 120 Front
* Protect wires to prevent scratching them at the edge of the compartment. EM-2436 P. 5 / 8 IT60SW6F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp CONNECTION DIAGRAM To other Modbus devices Antenna Connector DA DB DG SLD FE LAMP 1 INPUT LAMP 2 INPUT LAMP 3 INPUT LAMP 4 INPUT INPUT LAMP 5 INPUT Red*2 LAMP1*1 Amber*2 LAMP2*1 Green*2 LAMP3*1 Blue*2 LAMP4*1 White*2 LAMP5*1 BUZZER INP 1 Continuance Purple BUZZER1 BUZZER INP 2 Intermittence Cyan BUZZER2 LAMP BLINK COM POWER Brown BLINK Orange COM Gray Black
+
FE Green/Amber FE1 Connector for Maintenance/Configurator USB Connector
*1. Example of 5 layers in order: red, yellow, green, blue and white. Lamp and wire color are the same.
*2. When selecting the same color for more than one layer, cable colors comply with ordering information sheet. WIRING TO INPUT SIGNAL Contact input e.g. ON BLINK TOWER LIGHT LAMP1 LAMP2 LAMP3 LAMP4 LAMP5 BUZZER1 BUZZER2 BLINK COM NPN input e.g. BLINK TOWER LIGHT ON LAMP1 LAMP2 LAMP3 LAMP4 LAMP5 BUZZER1 BUZZER2 BLINK COM Note: If On and Blink are set simultaneously for a single lamp, Blink is disabled. At this time, if other lamps are being set to "Blink", they are also affected and work in the same manner. EM-2436 P. 6 / 8 IT60SW6F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp COMMUNICATION CABLE CONNECTIONS WIRING CONNECTION WITH SLAVE DEVICES WIRING CONNECTION WITH SLAVE DEVICES TERMINATOR
*
* The Unit DA DB DG SLD FE Remote Unit Remote Unit DA DB DG SLD FE TERMINATOR
* DA DB DG SLD FE
*1. Connect SLD and FE for reducing noise interference if necessary.
*2. For units at both ends of communication line, DA and DB must be connected with a terminator, however, for the unit, it is possible to set it by turning Terminator SW ON instead. TENSION CLAMP TERMINAL BLOCK Applicable wire size: 0.2 1.5 mm2 Stripped length: 10mm Recommended solderless terminal AI0,25-10YE 0.25 mm2 (Phoenix Contact) AI0,34-10TQ 0.34 mm2 (Phoenix Contact) AI0,5-10WH 0.5 mm2 (Phoenix Contact) AI0,75-10GY 0.75 mm2 (Phoenix Contact) MODBUS FUNCTION CODES & SUPPORTED CODES DATA AND CONTROL FUNCTIONS CODE 01 02 03 04 05 06 15 16 NAME Read Coil Status Read Input Status Read Holding Registers Read Input Registers Force Single Coil Preset Single Registers Force Multiple Coils Preset Multiple Registers EXCEPTION CODES CODE 01 02 03 04 05 06 07 NAME Illegal Function Illegal Data Address Illegal Data Value Slave Device Failure Acknowledge Slave Device Busy Negative Acknowledge Digital output from the slave (read/write) Status of digital inputs to the slave (read only) General purpose register within the slave (read/write) Collected data from the field by the slave (read only) Digital output from the slave (read/write) General purpose register within the slave (read/write) Digital output from the slave (read/write) General purpose register within the slave (read/write) Function code is not allowable for the slave. Address is not available within the slave. Data is not valid for the function. EM-2436 P. 7 / 8 IT60SW6F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp MODBUS I/O ASSIGNMENTS ADDRESS DATA TYPE Coils (0X) Inputs (1X) Input Registers (3X) Holding Registers (4X) Note: DO NOT access addresses other than the above. Such access may cause problems such as inadequate operation. DATA Digital Output (lamp, buzzer) Digital Input (lamp, buzzer) Unused Unused 1 16 1 16
----
----
----
----
OUTPUT DATA INPUT DATA 15 0 15 0 Output 0 Output 1 Output 15 Input 0 Input 1 Input 15 Output 0 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Lamp 1 Lamp 2 Lamp 3 Lamp 4 Lamp 5 Buzzer Lamp 1 Lamp 2 Lamp 3 Lamp 4 Lamp 5 Buzzer 0: Off, 1: On 0: Off, 1: On 0: Off, 1: On 0: Off, 1: On 0: Off, 1: On 0: Off, 1: Continuous 0: Off, 1: Blinking 0: Off, 1: Blinking 0: Off, 1: Blinking 0: Off, 1: Blinking 0: Off, 1: Blinking 0: Off, 1: Intermittent Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 Input 9 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Lamp 1 Lamp 2 Lamp 3 Lamp 4 Lamp 5 Buzzer Lamp 1 Lamp 2 Lamp 3 Lamp 4 Lamp 5 Buzzer 0: Off, 1: On 0: Off, 1: On 0: Off, 1: On 0: Off, 1: On 0: Off, 1: On 0: Off, 1: Continuous 0: Off, 1: Blinking 0: Off, 1: Blinking 0: Off, 1: Blinking 0: Off, 1: Blinking 0: Off, 1: Blinking 0: Off, 1: Intermittent Note: If On (Continuous) and Blinking (Intermittent) are set simultaneously for a single lamp (buzzer), Blinking is disabled. EM-2436 P. 8 / 8 IT60SW6F5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPANPhone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp