Version: 1.2 Dated: 31 October 2022 Door sensor installation instructions Part list Transceiver bracket Transceiver Sensor Magnet 6 screws Optional: Sikaflex 295 glue Instructions 1. Connect the unit to AC power and turn it on. 2. Check the software version and update as necessary. Go to the Service menu
, line S05 Configuration and line F02 SW version. 3. Turn the unit off and disconnect the power. 4. Open the right-hand container door. 5. Measure 20 cm from the left-hand door and hold up the sensor so it is flush with the roof rim. Using a pen, mark the position of the 2 holes. 6. If using screws, drill 2 holes size 3.8 - 4.0 mm. Otherwise apply Sikaflex 295 glue to the back of the sensor. Bjerndrupvej 47 6360 Tinglev, Denmark CVR/SE no.: 13 82 37 74 www.mcicontainers.com service@starcool.com +45 7364 3400 7. Ensuring that the arrows on the label or the flat side of the sensor point out to the container door, use a screwdriver and 2 screws to mount the sensor. If using glue, press the sensor firmly into position and hold it there for 1 minute before applying some tape to hold it in place while the glue is drying. Version: 1.2 Dated: 31 October 2022 8. Warning! 2 people needed for this step!
From inside the container with the door closed, hold the magnet up so it is aligned with the sensor. Again, using a pen, mark the position of the 2 holes. Open the container door again. 9. If using screws, drill 2 holes size 3.8 - 4.0 mm. Otherwise apply Sikaflex 295 glue to the back of the magnet. Bjerndrupvej 47 6360 Tinglev, Denmark CVR/SE no.: 13 82 37 74 www.mcicontainers.com service@starcool.com +45 7364 3400 10. Use a screwdriver and 2 screws to mount the magnet. If using glue, press the magnet firmly into position and hold it there for 1 minute before applying some tape to hold it in place while the glue is drying. Leave the container door open. Version: 1.2 Dated: 31 October 2022 11. Remove the right-hand inspection cover. 12. Measure 6 cm from the evaporator back panel and place the transceiver bracket onto the evaporator centre plate. Using a pen, mark the position of the 2 holes. Be sure that the 2 holes are in the centre of the plate. Bjerndrupvej 47 6360 Tinglev, Denmark CVR/SE no.: 13 82 37 74 www.mcicontainers.com service@starcool.com +45 7364 3400 13. Using a drill size 3.8 4.0 mm, make the 2 holes. Version: 1.2 Dated: 31 October 2022 14. Use a screwdriver and 2 screws to mount the bracket. 15. Slide the transceiver into the bracket so it clicks into place. 16. Disconnect the humidity sensor from the communication cable and connect the transceiver to the communication cable and the humidity sensor. Bjerndrupvej 47 6360 Tinglev, Denmark CVR/SE no.: 13 82 37 74 www.mcicontainers.com service@starcool.com +45 7364 3400 17. Secure the cables with cable ties if necessary. The cables must not hang down touching the evaporator fins. 18. Mount the right-hand inspection cover again. Version: 1.2 Dated: 31 October 2022 19. Connect power to the unit and turn it on. 20. Ensure the container door is open. 21. Go to the Service menu value from No to Yes.
, line S05 Configuration, line F15 Door sensor and change the 22. Go to the Service menu
, line S11 Door sensor. Check that the Status is Open, the Receiver is Yes and the Sensor is Yes. 23. Close the container doors and confirm that the Status then changes to Closed. Bjerndrupvej 47 6360 Tinglev, Denmark CVR/SE no.: 13 82 37 74 www.mcicontainers.com service@starcool.com +45 7364 3400 Version: 1.2 Dated: 31 October 2022 Bjerndrupvej 47 6360 Tinglev, Denmark CVR/SE no.: 13 82 37 74 www.mcicontainers.com service@starcool.com +45 7364 3400 Version: 1.2 Dated: 31 October 2022 Technical data:
Bluetooth version: BLE 5.1 Frequency range: 2402 MHz to 2480 MHz Sekstant Door sensor maximum output power: -6.40dBm Sekstant BLE Transceiver maximum output power: -3.10dBm If you have any questions about this instruction, please contact: service@starcool.com. Bjerndrupvej 47 6360 Tinglev, Denmark CVR/SE no.: 13 82 37 74 www.mcicontainers.com service@starcool.com +45 7364 3400