all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User manual 1 of 2 | Users Manual | 1.59 MiB | ||||
1 |
|
User manual 2 of 2 | Users Manual | 1.46 MiB | ||||
1 | Parts List/Tune Up Info | |||||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos |
1 | User manual 1 of 2 | Users Manual | 1.59 MiB |
THIR-6000 Bluetooth Series THIR-6000B THIR-6000HB THIR-6000DM-B Handheld Image Reader
(Linear / 2D Scanner) OPERATION MANUAL TOHKEN CO., LTD. 1st Edition April 15, 2008
[Memorandum]
Copyright 2006 Tohken Inc. and/or its suppliers. All rights reserved. COPYRIGHT NOTICE The contents of this document may not be copied or supplied in any form, in whole or in part without prior written consent from Tohken Tohken does not assume responsibility for errors or omissions and makes no guarantees or representations related to the quality, content or adequacy of the information contained in this document. Tohken does not warrant or represent any license, either expressed or implied, granted under any patent, copyright, or other intellectual property of Tohken for any product or process that uses Tohken products or services. Tohken does not endorse third party products or services published in this document. Tohken makes no guarantee of performance or suitability of its products, nor does Tohken assume any liability that occurs from the use of the product. Tohken reserves the right to make changes to its products and this document without any notice. APPLICATION NOTICE Tohken products are not designed or intended for use as a component in life support appliances or as surgical implants nor in any other application where failure of the product could cause personal injury or death. The use of Tohken products shall indemnify and hold harmless Tohken and its shareholders against any claims of injury or death associated with unintended authorized use. TRADEMARKS Tohken, Tohken and the Tohken Logo are marks of Tohken Inc. The names of any companies and products mentioned in this document may be the marks of their respective owners. Bluetooth is a registered trademark of Bluetooth SIG. Microsoft, Windows is registered trademarks or trademarks of Microsoft Corporation. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged CONTACT INFORMATION Tohken Ltd., 2-7-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo Japan 163-0710 Tel: +81-3-5325-4311 www.tohken.co.jp Introduction Thank you for purchasing this product. This manual explains the features of this product, operation, system configuration, specifications, etc. In order to use the product properly, please read this manual carefully. When there is any problem during normal use, please document it carefully to be reproduced by our support team. The contents of this manual may be changed without a notice. Please check our website for regular updates Safety Notice DO NOT DISASSENBLE Follow Please do not disassemble this product as this will void the warranty and might cause an accident. Please follow the warnings or notices of computers to be used with this product. Please stop using the product when there is smoke smell or strange sound to avoid fire. PULL OFF I Handling with care CAUTION About backup data This product has a memory backup function. This backup can not guaranteed if repair, reconstruction, and upgrade are performed on this Image Reader. CAUTION Please do not use this product at temperature or humidity ranges that are different from the product specifications or under the direct sunshine. CAUTION Please do not drip water, moisture, oil, etc. on the unit. CAUTION This unit can be damaged in environment with corrosive gas. CAUTION When stain or dust is stuck on the reading window, please follow the following steps to clean it:
- Wipe off stain lightly with cloth or swab (wet with alcohol)
- Wipe off again with the dry clothes. DO NOT Wipe off with any chemicals. CAUTION This is a high-precision optical device. Avoid shocking the product such as fall. II CAUTION This unit is designed to use with general electronics devices such as personal computer, office automation equipment, mesurement hardware, industrial robot, AV device etc. Please care specially if try to use for safety unit of transportation vehicle (cars, train, airplane), traffic right, gas leak sensor or other device for safety. Please do not use for devices for satelite, devices for nueclear or other devices which involves human lives. The frequency band of this unit (IEEE802.15.1) is also used by other industrial, scientific or medical instruments like microwave (ISM band). To avoide cross talk, please follow the following instruction. 1. Please check if there is in-building base station or small valtage wireless base station or amture wireless base station to detect mobile communication devices 2. By any possibility, if THIR-6000B causes cross talk please contact our sales department. Prohibited Please be carefull to deal with Li-ion battery. Improper treatment or use of batteries may present a danger of fire, explosion, leakage, or other hazard. Please do not disassemble the battery. Avoide strong impact on the battery. Never dispose of batteryies in a fire bacause they may explode. Never use or charge battery with opposed polarity. Never connect + and by steal wire or something. Also dont carry the battery with metal accessories or bobby pin. Never use microwave with the battery in. Never use other cradle to charge the battery. Never charge the battery by connecting it directory to outlet. Avoide colse to a fire or strong sun shine when charging the battery. Prohibited Please treat this uint gentry. This unit is a precision equipment. III Where to store CAUTION Please do not use/store this unit in the following environment to avoid electrification, fire, defect on the unit, cause damage on other device placed around.
- The temperature or humidity is out rage of the Specification.
- There is a danger of water leakage and electricity leakage.
- The direct sunshine hits.
- It has a dust, salinity and a iron content etc in atmosphere around.
- The static electricity is easy to occur.
- The fire is close, or heat is easy to be confined.
- It has the inflammable or explosive gas in atmosphere around. This product is not explosion-proof construction.
- The corrosive gas is included in atmosphere around. Long-term storage CAUTION During storage this unit, be sure to avoid the place where there is vibration, dust, high humidity, low temperature, high temperature and direct sunshine. Wireless device This unit is 2.4GHz band wireless device. License, registration and/or contract to use this device are not needed to use this unit. IV Unpacking the product After opening the shipping package containing the THIR-6000, take the following steps:
1- Check for damage that might occur during the shipping process. Report the damage immediately to the carrier who delivered the shipment. 2- Save the shipping container for later storage or shipping. 3- Make sure everything ordered is present. Components THIR-6000B series Start-up Instruction Manual Items not included with the product Charging base (TBC-6000) Used to charge rechargeable battery of THIR-6000B series Qty 1 1 TBC-6000 AC Power Adaptor (Optional): In case of purchase separately, select an adapter with output DC3V to DC6V range and more than 10W. Please confirm polarity and DC plug type as below. Polarity:
DC plug type: EIAJ RC5320A Voltage Segment 2 V Table of Content INTRODUCTION .....................................................................................................................................................I SAFETY NOTICE.....................................................................................................................................................I HANDLING WITH CARE....................................................................................................................................II WHERE TO STORE..............................................................................................................................................IV CAUTION
...........................................................................................................................................IV PLEASE DO NOT USE/STORE THIS UNIT IN THE FOLLOWING ENVIRONMENT TO AVOID ELECTRIFICATION, FIRE, DEFECT ON THE UNIT, CAUSE DAMAGE ON OTHER DEVICE PLACED AROUND...................................................................................................................................................IV LONG-TERM STORAGE.....................................................................................................................................IV WIRELESS DEVICE.............................................................................................................................................IV UNPACKING THE PRODUCT...........................................................................................................................V 1. GETTING STARTED.....................................................................................................................................4 1.1 SCANNER COMPONENTS..................................................................................................................................6 1.2 HOW IT WORKS..................................................................................................................................................8 2. HOW TO USE THIR-6000B.........................................................................................................................9 2.1. BATTERY CHARGING........................................................................................................................................9 2.2 SETTING UP THE HOST COMPUTER..............................................................................................................11 2.3 SETTING VIRTUAL COM PORT ......................................................................................................................12 2.4 CONFIRMING TRANSMITTING DATA..............................................................................................................12 2.5 IMAGE PREPROCESSING [ONLY FOR DM TYPE] ..........................................................................................12 3. OPERATION..................................................................................................................................................13 3.1 BARCODE READING.........................................................................................................................................13 3.2 BEEPING SOUNDS...........................................................................................................................................14 3.3 IMAGE DATA TRANSACTION...........................................................................................................................14 3.4 VIBRATION.......................................................................................................................................................14 4. COMMUNICATIONS..................................................................................................................................15 4.1 DATA TRANSACTION.......................................................................................................................................15 4.2 IMAGE DATA TRANSACTION..........................................................................................................................15 5. SPECIFICATIONS.......................................................................................................................................16 1 5.1 GENERAL SPECIFICATIONS............................................................................................................................16 5.2 FUNCTIONAL SPECIFICATION........................................................................................................................17 5.3 READING RANGE/DEPTH...............................................................................................................................18 5.4 DEFAULT SETTINGS........................................................................................................................................22 6. DIMENSIONS....................................................................................................................................................23 6.1HOUSING DIMENSIONS...................................................................................................................................23 7. SPECIALTY FUNCTION................................................................................................................................24 7.1 GLOBAL SHUTTER..........................................................................................................................................24 7.2 AUTO DETECTION MODE................................................................................................................................26 7.2.1 Overview .................................................................................................................................................26 7.2.2 How to use...............................................................................................................................................27 7.3 FOR HIGH DENSITY BARCODES......................................................................................................................29 7.4 HOW TO CONFIGURE SECURITY SETTINGS...................................................................................................29 7.5 HOW TO CONFIRM DATA TRANSMITTING......................................................................................................30 7.6 IMAGE PREPROCESSING.................................................................................................................................32 8. TROUBLESHOOTING...............................................................................................................................33 8.1 THE UNIT DOES NOT WORK WHILE PUSHING THE READ TRIGGER SWITCH..............................................33 Does the battery have enough amounts?...................................................................................................33 8.2 CAN NOT CHARGE BATTERY...........................................................................................................................33 Is THIR-6000B placed on the cradle correctly?.........................................................................................33 Is the AC adapter inserted correctly?..........................................................................................................33 Is power supply polarity correct?..................................................................................................................33 Is the power rating of the power supply enough?.....................................................................................33 Is the charging terminal clean?....................................................................................................................33 Isnt the battery too old?.................................................................................................................................33 8.3 BARCODE CANNOT BE READ.........................................................................................................................34 Is there beep from the buzzer when THIR-6000B reads barcode? .......................................................34 Is a code setup correct?...................................................................................................................................34 Is reading distance suitable?.........................................................................................................................34 Is the surface of the code glossy?..................................................................................................................34 Is the reading window clean?........................................................................................................................34 Is the print quality of the code good?...........................................................................................................34 8.4 READING DATA GETS GARBLED.....................................................................................................................35 Do you set fixed digit for ITF.........................................................................................................................35 8.5 BLUETOOTH CONNECTION IS DISCONNECTED ............................................................................................35 Is THIR-6000B in the range or Bluetooth connection? ...........................................................................35 8.6 READING DATA IS MISSED PARTIALLY DURING TRANSMITTING.................................................................35 2 Is the connection disconnected during transmitting?..............................................................................35 8.7 KEYBOARD WEDGE INTERFACE IS NEEDED .................................................................................................36 8.8 PIN CODE IS REQUIRED WHEN BLUETOOTH CONNECTION IS ESTABLISHED........................................36 APPENDIX 1 CRADLETBC-6000..............................................................................................................37 3 1. Getting started Equipped with a powerful state-of-the-art 2D Imager Scanner and processing CPU, the THIR-6000 is ready to capture images as well as decoding 1D or 2D bar codes. The THIR-6000 is a 2D Imager Scanner that reads Liner, 2D, and Postal barcodes to meet many different requirements in Delivery, Transportation, Meter Reading, and many other applications. The ergonomic design of the THIR-6000 provides user comfort even during lengthy scanning sessions. The new THIR 6000 Bluetooth has the same powerful performance as our THIR 6000. It comes in a IP64 housing with audible sound and vibration feedback for noisy industrial environments. Together with the wireless freedom this new THIR 6000 will be very suitable for many applications in retail and industry. 1) Supported barcodes Code39 Code128 Codabar ITF (interleaved 2 of 5) JAN/EAN/UPC RSS Code93 The unit can read the following symbols:
1D bar codes:
2D codes:
Data Matrix (ECC200) QR Code Micro QR PDF 417 Micro PDF Maxi Code Composite 2) Picture taking (except THIR-6000(H)U as a Human Interface Device) The THIR-6000B can take pictures for like seal, signature or ID photo. 4 3) Ordering information THIR-6000 (H) (DM) B 1 2 3 1. Resolution If H follows THIR-6000, the scanner is high resolution type. And if there is no H, the scanner is normal resolution type. 2. Direct Parts Marking If DM follows THIR-6000 or THIR-6000H, the scanner is for direct parts marking application. DM type has special settings of optics and illumination. 3. Bluetooth B means the interface of THIR-6000 is Bluetooth. According to this rule, there are 3 types of THIR-6000B family. THIR-6000B THIR-6000HB THIR-6000DM-B 5 1.1 Scanner components Reading Window Charging terminal Reading Switch Grip Handle Figure1a. Front View 6 Indicator for battery status Indicator for Wireless connection Monitoring LED Buzzer hole Guide for setting-on to the cradle Figure1b. Side and rear View 7 1.2 How it works Monitoring LED The monitoring LED lights up either GREEN or RED depending on the operation:
GREEN light indicates the completion of successful decoding of a symbol. Flashing GREEN light indicates the image data transmission in progress. RED light indicates the failure of data transmission. Triggering Switch This switch is used to initiate the read and decode of a symbol. Turn-ON: Connected Turn-OFF: Disconnected Indicator for wireless connection GREEN light indicates the status of wireless connection.
Indicator for battery status GREEN, ORANGE, RED light indicates the status of battery.
GREEN: Remained enough ORANGE: Charging. RED: Low battery Buzzer Buzzer indicates states of reading and communication. Charging terminal Used to charge the battery Guide for setting-on to the cradle Used to adjust the position when THIR-6000B is set to the charging cradle 8 2. How to use THIR-6000B 2.1. Battery charging Insert THIR-6000B by adjusting its guide to the slit of the cradle. THIR-6000B employs Li-ion rechargeable battery. Since new batteries are not fully charged, please charge the battery by following the instruction below. Setting THIR-6000B on to the cradle starts charging the battery.
*Please see Appendix 1 for more information about the cradle. 1. 2. Lift down the charging terminal to the cradle Slit 9 3. The indicator for battery status will change to orange. When the battery is fully charged, it will turn green. Normally, the charging time is 3 hours. Indicator for battery status Green: Remained enough Orange: Charging Red: Low battery CAUTION Charging time is varied depending on remained amount Please set THIR-6000B correctly to the cradle otherwise charging process may be failed Dust and dirt on the charging terminal may prevent to be charged correctly. Please keep it clean by using cotton with ethanol or other neutrality detergent. The rechargeable battery does not last forever. If a change in the battery life is noticed, it is probably time to purchase a new battery. Criterias to know the time to change the battery are 300 times of charging/discharging or 2 years of usage under proper environmental condition. Please contact our sales department about alternative battery. 10 2.2 Setting up the Host Computer Preparation Install the software comes with Bluetooth adopter. THIR-6000 can be connected to the host computer even when it is being charged. 2.2.1 1.
*Please see the operation manual of the adapter. 2. 3. Connect THIR-6000B with the software.
*Please see the operation manual of the adapter. Start the software 2.2.2 Check the status of connection Indicator for wireless connection If the indicator for wireless connection turns green, THIR-6000B is connected to host computer. If it turns off, it is disconnected. 2.2.3 Green: Connected Off: Disconnected Security settings PIN CODE can be set for a security reason. Please see 7.4 How to configure security settings. 11 2.3 Setting virtual COM port 2.3.1. Communication settings By using profile of Bluetooth (SPP), THIR-6000B can be communicated with the host computer through virtual COM port. Communication settings, like baud rate or frame structure, are not valid for THIR-6000B. 2.3.2. Communication protocol Communication protocol is not needed to be set. The host computer has to be equipped the software with the following functions. Receiving data from THIR-6000B Sending serial command to THIR-6000B Receiving picture from THIR-6000B Please contact our sales department about sample of this software. 2.4 Confirming transmitting data Barcode data read by THIR-6000B is sent to host computer. It is possible to let users know if the data is correctly transmitted to the host by using buzzer, LED indicator and vibration. Please see more detail at 7.5. How to confirm data transmitting. 2.5 Image preprocessing [Only for DM type]
For barcodes which has low contrast or bad quality of printing/marking, THIR-6000DM-B has image preprocessing functions. These work well especially for direct parts marking application. Please see detailed command list at 7.6 Image preprocessing. For more detail about image processing, please ask our sales department about Operation manual for image preprocessing. 12 3. Operation 3.1 Barcode reading Once the user pulls the reading switch, the THIR-6000 shows two red points by LED light to indicate the proper reading area. Note: The unit turns off the red dot-shaped laser pointer automatically after 30 seconds if there is no reading operation. Triggering the READ switch, the unit again displays the red laser dot. The unit will try to read the target symbol which is in the center of red pointers as shown in the figure below:
Upon completion of successful reading, the monitoring LED lights up GREEN and the unit beeps once. Release the reading switch. 13 3.2 Beeping Sounds Event or Status of scanner Power ON Succeeded in reading Fails to transmit the data On all the other occasions Sounds beeps 5 times short, short) Short beep 1 time Short beeps 7 times remains silent
(long, long, short, 3.3 Image data transaction
*) THIR-6000U as a HID can not capture images. Bitmap/image (name*.bmp, 1280 x 1024 pixel) Transmitting the data with serial interface takes 2 min. with baud rate 15.2Kbps (THIR-6000). In case of USB1.1, (THIR-6000(H)U), transmitting the image takes approximately 10 seconds. The green monitoring LED blinks while the unit transmits the image. Notes:
A) The host computer should be provided with software to receive the transmitted data. B) The image size is changeable. 3.4 Vibration When this unit can decode a symbol successfully, it vibrates itself. To enable/disable this function, the setting barcode menu is available. 14
1 | User manual 2 of 2 | Users Manual | 1.46 MiB |
4. Communications Bar Code Data Transmission:
The unit transmits the scanned data to the host computer. Command Signal Receipt:
The host computer transmits the command signals to the unit and sets up the operation of the unit. The unit transmits the captured image data to the host computer. Refer the section 5.5 for the communication parameter conditions. 4.1 Data Transaction Image Data Transmission:
Data transaction setup should be accomplished with sending command from host computer. Asynchronous protocol is used for barcode data transmission and serial commands transmission. 4.2 Image Data Transaction The communication protocol utilizes XMODEM (SUM128) in the case of the image data output. The host side computer should be provided with the software to receive the transmitted data. The receiving unit should also be kept ready before receiving the data. 15 5. Specifications 5.1 General specifications Type Dimensions Weight Illumination Aiming beam Indicator Image sensor Minimum resolution Supported barcodes (1D) Supported barcodes (2D) Format Bluetooth interface Battery Operating time Charging time Environmental specifications Operational Temperature Storage Temperature Operational Humidity Storage Humidity Vibration Shock THIR-6000(H) 159(H)63(W)99(D)mm Approx. 220 g (including the battery) 1. White LED (THIR-6000B, THIR-6000HB) 2. Red LED (THIR-6000DM-B) Red LED (peak wave length is 644nm) Monitoring LED (3 colors), Vibration CMOS color area sensor (1.3M pixel) 1. 0.125mm (1D barcode), 0.19mm (2D barcode)
(THIR-6000B) 2. 0.1mm (1D barcode), 0.167mm (2D barcode)
(THIR-6000HB, THIR-6000DM-B) Code39, Code128, EAN128, Codabar, ITF, JAN/EAN/UPC, RSS, Code93 Data Matrix (ECC200), QR Code, Micro QR Code PDF417, MicroPDF, MaxiCode, Composite Postal code ASCII or Bitmap(image) Bluetooth 2.0 Class1
*can be worked with Windows 2000/XP Li-ion rechargeable battery (3.7V, 2200mAh) 7 hours (calculated with 5 seconds per 1 barcode reading) 3 hours 0 to 40 degrees centigrade
- 20 to 60 degrees centigrade 35 to 85 %RH (Non-condensing) 35 to 85 %RH(Non-condensing) 10 to 55 Hz(max. 4G) Durable multiple drops to concrete from 7ft. 16 5.2 Functional specification 35 degree 35 degree 360 degree 0 to 10,000 lx Reading Direction PITCH SKEW TILT Ambient Light Viewing angle 17 5.3 Reading Range/Depth Decodable Symbols Code39, Code128, EAN128, Codabar, ITF, JAN / EAN / UPC, RSS Liner:
Check digit calculation method:
Code39 Codabar ITF Modulus 43 Modulus 16 Modulus 10 2-D:
Reading Digit:
(Except ITF) 12047
(Only ITF) 2,4,62047 Data Matrix(ECC200),QR Code, Micro QR Code,PDF417, Micro PDF, Maxi Code, Composite 18 33 26 Vertical Horizontal Distance from scanner Reading Range (Normal type) 50 66 about 34 95 about 27 50 75 150 unitmm 100 1D(0.125) 70110 1D(0.15) 60130 1D(0.25) 40160 1D(0.33) 40180 2D(0.19) 80110 2D(0.25) 60130 2D(0.33) 50160 Reading ability depends on environment (brightness etc) and the printing quality of scanned barcodes. Measured in 500 to 1000(lx) of homogeneous brightness, printed with good quality, no pitch and no skew. 19 33 Vertical Horizontal Distance from scanner Reading Range (High density type) 26 50 1D(0.1) 40 to 70 2D(0.19) 40 to 75 1D(0.125) 40 to 75 2D(0.167) 40 to 70 66 about 34 95 about 27 50 75 100 150 unitmm Reading ability depends on environment (brightness etc) and the printing quality of scanned barcodes. Measured in 500 to 1000(lx) of homogeneous brightness, printed with good quality, no pitch and no skew. 20 66 about 34 95 33 26 about 27 50 75 100 150 Vertical Horizontal Distance from scanner Reading Range (DM type) 50 1D(0.1) 40 to 70 1D(0.125) 40 to 75 2D(0.167) 40 to 70 2D(0.19) 40 to 75 unitmm Reading ability depends on environment (brightness etc) and the printing quality of scanned barcodes. Measured in 500 to 1000(lx) of homogeneous brightness, printed with good quality, no pitch and no skew. 21 5.4 Default settings When the unit is shipped from the factory, the initial setup is as follows:
THIR-6000B, THIR-6000HB Enabled Symbols: all symbols. THIR-6000DM-B Data Matrix (ECC200) and QR Code Security settings As the default, security settings are not configured. Please see 7.4 How to configure security setting. 22 6. Dimensions 6.1Housing Dimensions 63 99 9 5 1 Unit: mm 23 7. Specialty Function 7.1 Global Shutter Cropping is a method to remove unwanted areas from the image to make the image small. Following is the procedure to set up this function through the serial interface. Confirming the cropping status Serial Command ?IMG<cr>
<< Example of reply>>
******** STATUS ******** THIR-6000 BBC=0 0:256 1:16 2:RLE 3:AVE 4:AVERLE 9:Color IMODE=0 PX=0 PY=0 WX=1280 WY=1024 CAPMODE=0,0,1280,1024 CAPX=0 ( 0:100%, 1:75%, 2:50%, 3:25% ) CAPY=0 ( 0:100%, 1:75%, 2:50%, 3:25% ) VMODE=0 (0:Mono 1:Color )
********* END ********** THIR-6000 System version = K85C-V1.0c Decode version = K85A-V1.0c Setting for Bolded is status of cropping. Serial Command CAPX=m, CAPY=n (m,n=0,1,2,3)
<< Value >>
0100%
175%
250%
325%
24 Cropping CAPX=0CAPY=0 CAPX=2CAPY=1 100 75 50 25 25 50%
75 100 25 7.2 Auto detection mode 7.2.1 Overview By using this mode, THIR-6000 can read and decode symbols automatically. THIR-6000 detects changes of image in its field of view, like change of environmental brightness, motion of objects. When there is such a change, THIR-6000 starts to capture an image and tries to decode. This function is designed for stand mounting use to read documents with printed barcodes. For example, it is suitable for using on the counter at post office. CAUTION With Auto Detection mode, trigging switch does not work. Plus, neither does capturing an image, receiving a Hex program and executing a Macro program. Please turn Auto Detection mode OFF if those function are needed to be used. Auto Detection mode may not work well under the too high, too low or unstable brightness. corresponding configuration barcode to change to Auto Detection mode. mode regardless of current setting of the vibration. THIR-6000 does not vibrate when it decodes a symbol successfully with Auto Detection Auto Detection mode is not a default setting. Please have THIR-6000 read the Object with barcode Field of view Note 26 7.2.2 How to use To put the THIR-6000 in the auto detection mode, please follow one of the following methods:
- Send the serial command "LFMODE=1<CR>" to the scanner.
- Read the corresponding barcode from the configuration barcode set. To exit the auto detection mode, please follow one of the following methods:
- Send the serial command "LFMODE=0<CR>" to the scanner.
- Read the corresponding barcode from the configuration barcode set. The serial command "?LF<CR>" to check which mode the scanner is available. For the details of how to work Auto Detection mode, please see the following figures, flow chart and timing chart. 27 The flow chart of Auto Detection mode Monitor LED: Orange Monitor LED: Orange Aiming beam: Blinking Aiming beam: Blinking Standby Standby Make an object with Make an object with barcodes go into barcodes go into THIR-6000s field of THIR-6000s field of view view Label in Label in Detected?
Detected?
Yes Yes Try to decode Try to decode Yes Yes No: Timeout No: Timeout No: Timeout No: Timeout Within Within decoding time decoding time limit?
limit?
Within Within detection detection ignored limit?
ignored limit?
Decoded?
Decoded?
No No Yes Yes Yes Yes Yes Yes Verify Verify Compare decoded data Compare decoded data with last decode data. with last decode data. No No Label out Label out Detected?
Detected?
Different data Different data Same data Same data Monitor LED: Green Monitor LED: Green Buzzer : beep 1 time Buzzer : beep 1 time Monitor LED: Red Monitor LED: Red Buzzer : beep 2 times Buzzer : beep 2 times Out put the decoded data Out put the decoded data 28 When THIR detects a label is coming in, this signal turns OFF This signal is kept ON until THIR decodes successfully the decoded) or the decoding time limit is not passed.)
(including discarding When THIR detects a label goes out from FOV or the detection is passed, this signal turns OFF. ignored time Label in detection Decoding Label out detection ON OFF ON OFF ON OFF Timing chart 7.3 For high density barcodes HD mode is designed to read high density barcodes (under 0.167mm of small element size) more quickly. Since this is not a default setting, please change to HD mode by reading the corresponding configuration barcode. 7.4 How to configure security settings Show status data string1 If the data is correctly received, THIR-6000B is connected to the host computer. Serial command
PIN CODE=XXXX Put 4 digit numeric to XXXX. Bluetooth connection will be disconnected when PIN CODE is set. Please enter the PIN CODE to connect again. If set PIN CODE as 0000, there is no security. WSETS Write settings to THIR-6000s flash memory (make sure the connection is established) 29 7.5 How to confirm data transmitting To make sure the connection is established, the following method is strongly recommended. It will take approx. 20 second to detect disconnection between THIR-6000 and the host computer caused. The data tried to be sent to the host during this 20 second will be lost. By using the following method, operator can know if the data is correctly transmitted or not. THIR-6000B waits response from the host after it sends data. This period can be configured as limit time. If THIR-6000B does not receive response from the host, THIR-6000B judges the data has been lost. To complete this function, the host has to have the function to send received or ACK (0x06) to THIR-6000B if it receives data from the scanner.
(1). Normal flow BCR Trigger ON Read/Decode Data transmit Buzzer beeps Vibration BCR Trigger ON Read/Decode Data transmit After time out LED ON Buzzer beeps Reading data Received or ACK HOST
(2)In case of NG HOST Reading data Received or ACK 30 How to switch confirmation ON OFF 1). Configuration barcode menu (Other document) 2). By sending serial command
By reading barcodes ANSWERBACK=X ANSWERBACKTIM=X Time out limit Confirmation ON/OFF 0: OFF (Default) 1: ON 13 second (Default:1) How it works THIR-6000B waits response from the host within the time our limit. During the time out limit, trigger signal and other serial command are not valid. After getting response from the host or passing the time out limit, trigger signal and other serial command become valid. How to indicate 1). Get response from the host Buzzer and vibrator indicate OK 2). No response from the host
Buzzer and red LED indicate NG OK NG Buzzer 2 times (high tone) 3 times (low tone) LED non Red LED ON (700msec) non Vibration 100msec 31 Contents Indicates the status of a image pre-processing setting contents 7.6 Image preprocessing Command
?PROC Article Image Preprocessing 3x3 Mask Filter 5x5 Mask Filter Article IPFUNC0=a1,a2,a3,a4,a5 FILTER33[ I ] [ j ]=a FILTER33DM=1-10000 FILTER55[ I ] [ j ]=a FILTER55DM=1-10000 No.0 Image Preprocessing Setting Set coefficient value of 3x3 mask filter.
(i, j=0 through 2, a= -99 through +99) Set magnification value of 3x3 mask filter. Set coefficient value of 5x5 mask filter.
(i, j=0 through 2, a= -99 through +99) Set magnification value of 5x5 mask filter. Description No Image preprocessing Erosion 2x2 Erosion 3x3 Erosion 5x5 Erosion 2x1 (w) Erosion 1x2 (h) Dilation 2x2 Dilation 3x3 Dilation 5x5 Dilation 2x1 (w) Dilation 1x2 (h) Reverse White & Black Cont (L12cut): Cut the rest (from the darkest) 12.5%
Cont (L22cut): Cut the rest (from the darkest) 25%
Cont (H23cut): Cut the most (from the brightest) 12.5%
Cont (H24cut): Cut the most (from the brightest) 25%
Cont (LH12cut): Cut the rest 12.5% and the most 12.5%. Cont (LH22cut): Cut the rest 25% and the most 25%. Gamma(r=0.5) Execution for Gamma Correction 0.5 Command 0 1 3 5 7 9 2 4 6 8 10 20 21 22 23 24 None Black Erosion White Dilation Reverse Contrast Enhancement 21&22 are used to enhance black 23&24 are used to enhance white Gamma Correction Smoothing Filter Median 3x3 Filter 5x5 Filter Down Size Down Size Please ask our sales department for more information. 40 41 60 61 70 71 25 26 27 Low pass Filter 3x3 average value Median filter 3x3 median value 3x3 filter FILTER33, FILTER33DM execution filtering by command 5x5 filter FILTER55, FILTER55DM execution filtering by command Down Size (Quick) Down size whole image with quick mode Down Size (Average) Down size whole image with average speed mode 32 8. Troubleshooting 8.1 The unit does not work while pushing the read trigger switch. Does the battery have enough amounts?
If the batterys voltage is not enough, THIR-6000B may not operate correctly. Please see 2.1 Charging battery. 8.2 Can not charge battery Is THIR-6000B placed on the cradle correctly?
If THIR-6000B is not placed on the cradle correctly, charging battery may be failed. Please see 2.1 Charging battery. Is the AC adapter inserted correctly?
If the AC adapter inserted correctly to the cradle, charging battery may be failed. Is power supply polarity correct?
When it is connected with reverse polarity, charging battery is failed. Correct polarity Is the power rating of the power supply enough?
Unless the power supply capacity is enough, charging battery is failed. Is the charging terminal clean?
If there is dirt/dust on the charging terminal, charging battery may be failed. Isnt the battery too old?
The rechargeable battery does not last forever. If a change in the battery life is noticed, it is probably time to purchase a new battery. Criterias to know the time to change the battery are 300 times of charging/discharging or 2 years of usage under proper environmental condition. Please contact our sales department about alternative battery. 33 8.3 Barcode Cannot be Read. Is there beep from the buzzer when THIR-6000B reads barcode?
YES Barcode is decoded, but an error is occurred during transmitting data through Bluetooth. Please see 8.4. Errors in transmitting data. NO Barcode is not decoded. Please see the following instruction to decode barcode correctly. Is a code setup correct?
Check the settings of the reader and that the 2D code is enabled Is reading distance suitable?
Reading may be impossible when the reading distance is outside the working range of reading depth. Moreover the printing quality of the code may make it non-readable even if it is within the reading range limits. Is the surface of the code glossy?
If the surface of the code is glossy, the illumination will be sometimes reflected like a mirror. To avoid this, put the scanner in angle relative to the symbol. Is the reading window clean?
If the window becomes dirty or stained, the image taken by the reader might not be good enough for reading. Clean with a lens cleaner or similar anti-scratching (non-abrasive) method. Is the print quality of the code good?
Please check whether print quality of the cells, code size, etc. conforms to the standard. 34 8.4 Reading data gets garbled Do you set fixed digit for ITF In some cases, cancellation of significant digits (reading it through with a few digits than a printed digits) in ITF(Interleaved 2 of 5) might be used. We recommend setting specific digit of ITF. 8.5 Bluetooth connection is disconnected Is THIR-6000B in the range or Bluetooth connection?
The Bluetooth unit of THIR-6000B allows staying away 10m from the Bluetooth adapter. But the distance is varied depending on conditions. Please check the strength of wave if it seems to be weak. In the utility screen of the driver, the strength can be checked. If it is weak, please use TMU-6000 to receive wave more efficiently. 8.6 Reading data is missed partially during transmitting Is the connection disconnected during transmitting?
Reading data can be missed partially if the connection is failed during the transmitting. Please check connectivity as explained 2.2 Setting up the host computer. 35 8.7 Keyboard wedge interface is needed If keyboard wedge software is installed to the host computer, THIR-6000B can be used as keyboard interface device. Please let our sales department know if keyboard wedge is needed. 8.8 PIN CODE is required when Bluetooth connection is established PIN CODE is not set at the time or shipment from our factory. To initialize PIN CODE, please use Default setting barcode in Configuration Barcode Menu. If PIN CODE is needed to be set, please see 7.4. How to configure security settings. 36 Appendix 1 CradleTBC-6000 1. Overview 2. Specification Dimensions Weight Tapped Hole Screw 3. Outlook Cradle for THIR-6000B series 72(H)90(W)241(D) Approx. 215g (AC adapter, wireless unit, and THIR-6000B are not included) 5 x 3 M4M20 2pcs (come with the cradle) Edge Rear Slit AC adapter jack Cable clamper Charging terminator Hook Please use one of the two tapped hole for charging terminator side. Tapped hole Fix the metal plate Hook the cable of AC adapter 37
[Memorandum]
Warranty Obligations Exclusive of the cases with special mentions in quotations, contracts or specifications, TOHKEN warrants this products as the following. 1. Term of warranty One year from the date of purchase. 2. Warranty Coverage TOHKEN will repair or replace the product at no charge if the reasons of defects are come from our responsibility. The losses caused by the defect of this product are not covered. If the reasons of defects are the following, they are not covered by this warranty.
(1). If the product is not used in accordance with all operation instructions.
(2). If the product is modified by outsiders of TOHKEN.
(3). If the defects are not caused by the product itself.
(4). If the defects are caused by fire, pollution, abnormal voltage, or natural disasters, such as earthquake, thunderstorm or flood. 3. Usage outside of Japan This warranty coverage is based on the usage in Japan. Please contact our sales department if there need to use this product ourside of Japan. 39 40 TOHKEN CO., LTD Head quarters 2-7-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo Japan 163-0710 03-5325-4311 to 4315 Sales Sales Promotion 03-5325-4322 Nagoya office 4-2-12 Meieki, Nakamura-ku, Nagoya Japan 450-0002 052-565-9091 Sales Osaka office Fukuoka office Hitachi office 2-9-1 Higashi-Tenman, Kita-ku, Osaka Japan 530-0044 06-6353-5476 Sales 8-36 Hakata-eki Chuogai, Hakata-ku, Fukuoka Japan 812-0012 092-441-3638 Sales 2-1-10 Hashikabe, Hitachinaka, Ibaragi Japan 312-054 029-276-9555 Sales Field support department (Technical Center 3) 1-43-2 Tamagawa, Chofu, Tokyo Japan 182-0025 042-484-5190 Field support 41
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2008-09-17 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2008-09-17
|
||||
1 | Applicant's complete, legal business name |
MARS TOHKEN SOLUTION CO. LTD.
|
||||
1 | FCC Registration Number (FRN) |
0018007625
|
||||
1 | Physical Address |
1-10-7 Shinjuku, Shinjuku-ku, Tokyo
|
||||
1 |
Tokyo, N/A 1600022
|
|||||
1 |
Japan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
m******@ccsemc.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
WK4
|
||||
1 | Equipment Product Code |
THIR-6000B
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
H****** S****
|
||||
1 | Title |
General Manager
|
||||
1 | Telephone Number |
+81 4********
|
||||
1 | Fax Number |
+81 4********
|
||||
1 |
s******@mars-tohken.co.jp
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Handheld Image Reader(Linear/2D Scanner) | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Compliance Certification Services Inc.
|
||||
1 | Name |
H**** L********
|
||||
1 | Telephone Number |
886-2******** Extension:
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
h******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 28 | 2402.00000000 | 2480.00000000 | 0.0210000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC