all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual Revised | Users Manual | 4.71 MiB | May 06 2014 | |||
1 | Cover Letter(s) | February 06 2014 / May 06 2014 | ||||||
1 | Cover Letter(s) | February 06 2014 / May 06 2014 | ||||||
1 | Operational Description | February 06 2014 / May 06 2014 | ||||||
1 | Operational Description | February 06 2014 / May 06 2014 | ||||||
1 | External Photos | February 06 2014 / May 06 2014 | ||||||
1 | Internal Photos | February 06 2014 / May 06 2014 | ||||||
1 | ID Label/Location Info | February 06 2014 / May 06 2014 | ||||||
1 | RF Exposure Info | May 06 2014 | ||||||
1 | Test Report | February 06 2014 / May 06 2014 | ||||||
1 | Test Setup Photos | February 06 2014 / May 06 2014 |
1 | User Manual Revised | Users Manual | 4.71 MiB | May 06 2014 |
Engineering Safety Advancing Automation Matrix IntelliZone Proximity Detection System Basic Information 3rd Party 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. DO NOT DISTRIBUTE Engineering Safety Advancing Automation IntelliZone System Index Basic Information System Warnings & Disclaimers (Page 3) System Warnings & Disclaimers, System Warning Labels System Introduction (Pages 4-6) Objective, Overview, Expanding Zones, Directional Zones, Articulating Machinery, Green Zone System Components (Pages 7-10) Overview, Driver, Locator, Controller, Software Key, Interconnect Board, XP Boxes, Antenna Mounts Maintenance Guide Driver (Page 12-14) Overview, Splitter Layout, Driver Installation Controller (Pages 15) Overview, LED Statuses System Information (Pages 16-18) Available System Drawings, Fasteners, System Installation Guidelines System Troubleshooting (Pages 19-22) Driver LEDs, Locator LEDs, Audible Alarm, Locator OLED Screen, Troubleshooting Tips, System Diagnostic Codes User Guide Operating Guidelines (Page 24) System Warnings, Precautions, System Overview Driver and Locators (Page25-27) Driver Overview, Locator Overview, LED Statuses Emergency Stop Override (Pages 28-29) DC, C2C, JNA 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 2 DO NOT DISTRIBUTE Engineering Safety Advancing Automation System Warnings & Disclaimers System Warnings & Disclaimers It is important that all users / personnel that may come into contact with the IntelliZone Proximity Detection System understand its purpose. It is NOT a safety system. It is a training aid developed to teach users safe operating habits. User / Operator assumes full responsibility for control of the machine upon which the system is installed. User / Operator assumes full liability for the maintenance and operation of the IntelliZone Proximity Detection System. System Warning Label The Matrix IntelliZone System includes several highly visible WARNING labels located on the front of the machine-mounted Drivers, and the user-carried Locators. All users / personnel that may come into contact with an IntelliZone Proximity Detection System equipped machine should familiarize themselves with all WARNINGS associated with the system. Additional WARNING labels for the IntelliZone System are available free-of-charge as requested. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 3 DO NOT DISTRIBUTE Engineering Safety Advancing Automation IntelliZone System Introduction Objective The intent of IntelliZone Proximity Detection is to provide a practical, mine-duty system that will automatically warn personnel when they are entering a potentially hazardous area around a machine. The system must be able to disable some or all machine functions if a particular zone is breached. System Overview The Matrix IntelliZone Proximity Detection System assists with training personnel to stay clear of dangerous zones present around potentially hazardous equipment. The System is designed for use on mobile equipment such as continuous miners, mobile haulage, and other light and heavy vehicles. The System is typically configured for two operational awareness zones: a shutdown zone (red) can be defined closest to the equipment and a warning zone (yellow) can be defined to extend a moderate distance from the equipment. When an IntelliZone Locator is detected within the red zone, the System will prompt the equipment to immediately shutdown some or all of its functions. When an IntelliZone Locator is detected within the yellow zone, the System will prompt the equipment to reduce its speed or influence other changes in operation. If a Locator is detected within either zone, the System will initiate highly-visible flashing lights and an audible alarm on the Locator and Drivers to warn personnel of potential hazards. Additional IntelliZone awareness zones can be configured as needed and are customizable to specific equipment and applications. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 4 DO NOT DISTRIBUTE IntelliZone System Introduction Engineering Safety Advancing Automation Standard Miner Configuration Consists of a shutdown zone (red) and warning zone (yellow), as well as operator zone (green) while cutting. These zones are configurable through software. Expanding Mobile Equipment Zones On mobile equipment, zones can be configured to expand as the machine accelerates. Oversized zones are no longer required on faster moving equipment. Directional Mobile Equipment Zones On mobile equipment, zones can be configured to react to the equipments direction. This prevents the machine from being shut down by personnel walking behind it. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 5 DO NOT DISTRIBUTE IntelliZone System Introduction Engineering Safety Advancing Automation Articulating Machinery On articulating machinery, the zones can configured to react to the pivoting of the machine. This enables the zones to remain consistent even when the machine is articulated. Operator (Green) Zone Operator zones can be configured using the Intellizone GUI. These operator zones are critical in that it allows the associated Locator to be in the area without shutting down the machinery. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 6 DO NOT DISTRIBUTE Engineering Safety Advancing Automation IntelliZone System Introduction System Components The IntelliZone System is approved for use in potentially hazardous MSHA-regulated environments. Below is a typical layout for a system on a machine. System components may vary in quantity and location depending on the machine upon which it is mounted. MX3-IZ Driver (4 shown) MX3-IZ Locator MX3-IZ Splitter Box (2 shown) M3-1000 Guarding (2 shown) MX3-IZ Antenna Mounting Kit, Retrofit (2 shown) MX3-IZ Guarding (4 shown) MX3-IZ Power Supply Box MX3-IZ Proximity Controller Box 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive New-
burgh, IN 47630, USA | 812.490.1525 |
7 DO NOT DISTRIBUTE Engineering Safety Advancing Automation IntelliZone System Introduction MX3-IZ Driver The MSHA-approved Driver allows for tracking of multiple Locators. The Driver is machined from rugged polycarbonate and incorporates multi-color LEDs used for diagnostics and zone identifications. MX3-IZ Locator The MSHA-approved Locator is the device the operator wears and that is tracked around the machine. The Locator also has a built-in audible and visible warning. The operator uses this device to associate/dissociate. It can be worn in a pouch or using a belt clip. MX3-IZ Controller The Controller is the central processor for the IntelliZone System. It communicates to the mobile equipment and Locators and provides power to 4 machine-mounted Drivers. Personnel can connect to the Controller wirelessly (w/ adaptor) or with an Ethernet cable to adjust settings and view system diagnostics. This device IS NOT intrinsically safe and MUST be inside an explosion-proof enclosure when used in MSHA-regulated environments. MX3-IZ Software Key The Software Key must be installed on the Controller for the system to function. It can be moved to a new Controller in event of a failure. This stores the machine configuration and provides an Industrial Ethernet connection. The Software Key IS NOT intrinsically safe and MUST be inside an explosion-
proof enclosure when used in MSHA-regulated environments. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 8 DO NOT DISTRIBUTE Engineering Safety Advancing Automation IntelliZone System Introduction MX3-IZ Interconnect Board The Interconnect Board is the hub for all relays, inputs, outputs, power, etc. that interfaces to the Controller. This board mounts below the Controller and is designed for easy access to all wiring terminals. The Interconnect Board IS NOT intrinsically safe and MUST be inside an explosion-proof enclosure when used in MSHA-regulated environments. Controller XP Box This MSHA-approved enclosure houses the Controller, Software Key, and Interconnect Board. It features 7 ports that use 1.125-12 packing gland assemblies to ensure the enclosure remains explosion proof. Power Supply XP Box This MSHA-approved enclosure houses the Intellizone Power Supply. It features 4 ports that use 1.125-12 packing gland assemblies to ensure the enclosure remains explosion proof. Splitter XP Box This MSHA-approved enclosure is used to minimize the number of Controller XP Box ports needed. Typically 2 Splitter XP Boxes are used per system; one being placed on each side of the machinery. It features 4 ports that use 1.125-12 packing gland assemblies to ensure the enclosure remains explosion proof. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 9 DO NOT DISTRIBUTE Engineering Safety Advancing Automation IntelliZone System Introduction Driver Guarding The guarding around Driver is MSHA-approved and therefore must be manufactured to specific dimensions. The outer guarding must be at minimum 1/4 thick. The backing must be at minimum 5/8 thick. The gap between the guarding and Driver can not exceed 1/2. For more information see drawing # 10000099. Whip Antenna Kit This kit includes a 2.45Ghz Whip antenna, mounting hardware, polycarbonate cover, pipe nipple, and elbow for a large range of custom mounting configurations. This antenna kit is a proven design for haulage equipment such as shuttle cars and battery haulers. It requires much less room than the retrofit Antenna Kit. Retrofit Antenna Kit This kit includes a 2.45Ghz Whip antenna, mounting hardware, and a polycarbonate cover. It was designed to mount directly into existing guarding on equipment fitted with previous generation proximity detection systems. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 10 DO NOT DISTRIBUTE Engineering Safety Advancing Automation MX3-IZ Driver Installation Driver Cable Maintenance Guide 10000050 Shield White (Data +) Green (Ground) Red (+72VDC) Black (Data -) Front Driver Splitter Cable Back Driver 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 12 DO NOT DISTRIBUTE Engineering Safety Advancing Automation IntelliZone System Kits MX3-IZ Driver Standard Installation The MX3-IZ Guarding that protects the Drivers is specifically designed for the new smaller MX3-IZ Drivers unlike previous Matrix Proximity Systems with larger guarding. The Driver cable must be inside conduit for its entire run and must be connected to either a MX3-IZ Conduit Mounting Plate or a conduit mounting nipple that is attached to the back or top of the guarding. The driver is mounted using M12 x 85mm Hex head bolts with washers and lock washers. M12 Mounting Hardware MX3-IZ Driver MX3-IZ Conduit Mounting Plate MX3-IZ Guard 3/4 I.D. Rubber Hose Conduit S.S. Worm Gear Hose Clamp 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 13 DO NOT DISTRIBUTE Engineering Safety Advancing Automation IntelliZone System Kits MX3-IZ Driver Retrofit Installation The MX3-IZ Driver Adapter Kit is specifically designed for mounting the MX3-IZ Driver in the larger guarding that is standard on the older M3K-1000 Matrix Proximity System. The Driver cable must be inside conduit for its entire run and must be connected to either a MX3-IZ Conduit Mounting Plate or a conduit mounting nipple that is attached to the back or top of the guarding. The driver is mounted using M12 x 90mm Hex head bolts with lock washers. M12 Mounting Hardware MX3-IZ Driver Adapter Kit MX3-IZ Driver MX3-IZ Conduit Mounting Plate, Retrofit M3-1000 Guard 3/4 I.D. Rubber Hose Conduit S.S. Worm Gear Hose Clamp 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 14 Maintenance Guide 10000050 DO NOT DISTRIBUTE Engineering Safety Advancing Automation MX3-IZ Controller Overview The Controller is the central processor for the IntelliZone System. It communicates to the mobile equipment and Locators and provides power to 4 machine-
mounted Drivers. Personnel can connect to the Controller wirelessly (w/
adaptor) or with an Ethernet cable to adjust settings and view system diagnostics. This device IS NOT intrinsically safe and MUST be inside an explosion-proof enclosure when used in MSHA-regulated environments. LED States The Controller features (9) LEDs that can provide the operator with basic system diagnostics information. The LEDs are located on the top surface of the Controller, and can be in either a blinking or continuously lit (solid). Blinking Solid FUNCTION LED RESPONSE POWER HEARTBEAT I/O ACTIVITY RF ETHERNET DRIVER 0-3 CONTROLLER HAS POWER CONTROLLER SOFTWARE IS ACTIVE INTERFACE & PROXIMITY ARE ACTIVE I/O ACTIVITY (SD CARD OR SENSORS) RF ACTIVITY WIRED NETWORK ACTIVITY NORMAL OPERATION DRIVER DISABLED POWER FAILURE 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 15 DO NOT DISTRIBUTE Engineering Safety Advancing Automation Available System Drawings Maintenance Guide Drawing 10000058 10001901 10001691 10001659 10001978 10001638 10001685 10001639 10001950 10001950 10000152 10001288 10001974 10001975 10001976 10001977 10000112 10000127 10000132 10001603 Product Driver Charger Charging Rack Power Supply Box Controller Box Controller Box Controller Box Power Supply Box Antenna Kit Retrofit Antenna Kit Overall System Overall System C2C System JNA System DC System BH-18 System Category Installation Detail Product Overview Product Overview Schematic Schematic Product Overview Installation Detail Product Overview Installation Detail Installation Detail Product Overview Schematic Schematic Schematic Schematic Schematic Shuttle Car System Shuttle Car System 14CM15 R. System 14CM15 System Installation Detail Installation Detail Installation Detail Installation Detail Description Shows proper installation of Driver w/ and w/o adapter kit Provides generic Locator Charger dimensions and specs Provides generic Locator Charging Rack dimensions and specs Wiring Schematic for system power supply box Wiring Schematic for system Controller box Provides generic Controller XP Box dimensions and specs Shows proper installation of Controller XP Box w/ use of weld blocks Provides generic Power Supply Box dimensions and specs Shows proper installation of the Whip Antenna Mounting Kit Shows proper installation of the Retrofit Antenna Mounting Kit Provides a generic overview of the entire system Provides a generic overall system wiring schematic Provides an overall system wiring schematic for a JOY C2C machine Provides an overall system wiring schematic for a JOY JNA machine Provides and overall system wiring schematic for a JOY DC machine Provides an overall system wiring schematic for a JOY BH-18 machine Provides a generic system layout on a Standard Shuttle Car Provides a generic layout of Driver Guarding on a Standard Shuttle Car Provides a generic retrofit system layout on a JOY 14CM15 machine Provides a generic system layout on a JOY 14CM15 machine Multiple Drawing Numbers are available for product under the listed category. Please request drawings by Product column name to receive a list of available drawings for the desired product. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 16 DO NOT DISTRIBUTE Engineering Safety Advancing Automation Maintenance Guide Fasteners MX3-IZ Driver MX3-IZ Driver Retrofit Kit MX3-IZ Controller XP Box MX3-IZ Power Supply XP Box MX3-IZ Machine Mount Blocks Fastener Quantity Hex Head M12-1.75x85 Washer M12 Washer Split Lock M12 Hex Head M12-1.75x90 Washer Split Lock M12 Hex Head 1/2-13x1.25 Washer Split 1/2 Nut Hex Jam 3/8-16 Hex Head 1/2-13x1.25 Washer Split 1/2 Nut Hex 1/4-20 Hex Head 1/2-13x1.0 Washer Split 1/2 4 4 4 4 4 10 10 4 10 10 4 1 1 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 17 DO NOT DISTRIBUTE Engineering Safety Advancing Automation Maintenance Guide Installation Requirements Drivers can be mounted upside down, but must be vertical Controller and Power Supply XP Enclosures must pass 0.004 feeler gauge inspection Splitter XP Enclosures must pass 0.002 feeler gauge inspection XP Gland Gap (Between Gland Plug and XP Box Steel Port) must measure between 1/8 MIN, 1/4 MAX Glands must be secured with a lead tie or set screw Open gland ports must be sealed using Steel Plug, and plug must be spot welded in place Components on a common frame must be solidly frame grounded The Intrinsically safe portion of the RF Barrier must be kept isolated from the non-Intrinsically safe wiring Ensure that RF antennas are isolated from machine ground Driver cables and 8-pair Matrix Cable must be installed with protective conduit and clamps Antenna cables (LMR195-fr) do not require conduit but are highly recommended for protection Though not required, ferrules or tinning the end of all wires inside the Controller XP Box and Splitter XP Box is recommended 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 18 DO NOT DISTRIBUTE Engineering Safety Advancing Automation Maintenance Guide MX3-IZ Driver LED States The Driver features an array of (27) LEDs that can provide the operator with basic system diagnostic information. The LEDs are visible from the front of the Driver, and assume either a blinking or solid state. Knowledge of Driver LED codes can help isolate system errors, should a problem arise. The error codes are communicated to personnel by means of LED color and duration. DEFINITION TIME DURATION (SECONDS) System operational; no Locator associated as operator 1.0 System operational; Locator associated as operator 1.0 Continuous 1.0 Warning Zone Breach Shutdown Zone Breach Proximity Protection System is bypassed System Error MX3-IZ Locator Error MX3-IZ Driver Error (Diagnostic Warning); single LED MX3-IZ Driver Error (Diagnostic Error); single LED Continuous Continuous Continuous Continuous MX3-IZ Locator LED States The Locator features (3) LEDs that can provide the operator with basic system diagnostic information. The LEDs are visible from the front of the Locator, and assume either a blinking or solid state. Knowledge of Locator LED codes can help isolate system errors, should a problem arise. The error codes are communicated to personnel by means of LED color and duration. DEFINITION System Operation Normal Warning Zone Breach Shutdown Zone Breach TIME DURATION (SECONDS) 1.0 1.0 1.0 System, Locator, or Driver Error Continuous 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 19 DO NOT DISTRIBUTE Engineering Safety Advancing Automation Maintenance Guide MX3-IZ Audible Alarm The Locator also features an audible alarm that can alert users and/or nearby personnel of a zone breach. DEFINITION Warning Zone Breach Red Zone Breach TIME DURATION (SECONDS) OLED Screen The user-interface screen on the front of the Locator provides personnel with important system diagnostics information. It allows users to initiate key features of the IntelliZone System. It is important to understand the information provided and how to properly interact with the Locator. User input is provided through the push-button found atop the Locator and prompts on the OLED screen. STATUS SCREEN (PRESS + HOLD) ASSOCIATE / DISSOCIATE (DOUBLE CLICK) Signal Strength and Battery Level System Status and Locator Operating Voltage When displayed, test using MX3-IZ Locator Tester Locator Identification Development Information Development Information This allows users to associate / dissociate themselves as an operator of a particular piece of machinery. In order to do so, there must first be an Initiation Zone configured using the IntelliZone System GUI (Graphical User Interface). Standing inside this zone, the user may associate or dissociate as operator by double-clicking the Locators push-button. Double-click again to confirm association / dissociation. There will be (2) quick audible signals confirming that the process was successful. If user requests association / dissociation but fails to confirm within
(10) seconds, the Locator will timeout and default to normal operation. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 20 Power Supply DO NOT DISTRIBUTE Engineering Safety Advancing Automation Maintenance Guide Troubleshooting These issues have been observed by Matrix Technicians. Inspections Locators should be inspected for physical damage before every shift. Locators should also be tested above ground before every shift. Drivers should be inspected for physical damage before every shift. Operator Dissociating Issues RF is CRITICAL to the operation of the system. If the zones are not consistent or the Locator is not tracking well check RF cables and antenna. If the operator moves too far from the machine, he will have to re-associate to use the piece of equipment. The opera-
tor will see the green LEDs flashing on the Drivers when he is NOT the operator. If the operator is having to re-associate often, there is likely an issue with the RF antenna or cabling. If the system is not powering up, check 72VDC and 24VDC power in the interface board. If no voltage found on the interface board, check 3A glass fuses in the Power Supply XP box. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 21 DO NOT DISTRIBUTE Engineering Safety Advancing Automation System Diagnostic Errors System Diagnostic Codes The IntelliZone Proximity Detection System features machine status codes to assist the user in determining the source of an issue should one arise during operation. These codes result from diagnostic tests that are continuously executed by the Controller, and can be viewed in the IntelliView Diagnostic Data Inspection window or on an associated Locators OLED screen. Press and hold the Locators Push-button to display a 7-
digit machine status code. ERROR CODE CORRECTIVE ACTION 3.02.0000, 4.02.0000 Reboot, Replace Driver 3.02.0001, 4.02.0001 Check Driver data wires, Replace Driver 3.02.0002, 4.02.0002 Check Driver power wires, Replace Driver 3.02.0003, 4.02.0003 Check Interface board, Replace Interfaceboard, Replace Driver 3.02.0004, 4.02.0004 Contact Matrix 3.02.0005, 4.02.0005 Check 72V power supply and fuses 3.02.0006, 4.02.0006 Reboot, Replace Driver 3.03.0000, 4.03.0000 Replace Controller 3.03.0002, 4.03.0002 Too many locators or controllers in area 3.03.0003 Will display when Analog inputs are not in use 3.05.0000, 4.05.0000 Too many controllers in area 3.10.0000, 4.10.0000 Call Matrix 3.10.0001, 4.10.0001 Call Martix, Replace controller 3.10.0002 4.10.0002 Order new Software Key Replace Software Key PART Driver Driver Driver Driver Driver Driver Driver RF Module RF Module RF Module Prox Sensor Controller Controller Controller Controller 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 22 DO NOT DISTRIBUTE Engineering Safety Advancing Automation Operating Guidelines User Guide System Warning It is important that all users / personnel who may come into contact with the IntelliZone Proximity Detection System understand its purpose. It is NOT a safety system. It is a training aid developed to teach users safe operating habits. User / Operator assumes full responsibility for control of the machine upon which the system is installed. User / Operator assumes full liability for the maintenance and operation of the IntelliZone Proximity Detection System. Based upon this understanding, the following precautions must be taken. Precautions Do not use the IntelliZone system without proper training and documentation The Locator must be worn at all times Position the Locator between shoulder and waist height on the front side of the body for proper operation Do not position the Locator near metal tools, cap lamp battery, or other metal items while operating the system When operating the machinery on a grade use extra caution as the machine may coast further than normal System Overview The Matrix IntelliZone Proximity Detection System assists with training personnel to stay clear of dangerous zones present around potentially hazardous equipment. The System is designed for use on mobile equipment such as continuous miners, mobile haulage, and other light and heavy vehicles. The System is typically configured for two operational awareness zones: a shutdown zone (red) can be defined closest to the equipment and a warning zone (yellow) can be defined to extend a moderate distance from the equipment. When an IntelliZone Locator is detected within the red zone, the System will prompt the equipment to immediately shutdown some or all of its functions. When an IntelliZone Locator is detected within the yellow zone, the System will prompt the equipment to reduce its speed or influence other changes in operation. If a Locator is detected within either zone, the System will initiate highly-visible flashing lights and an audible alarm on the Locator and Drivers to warn personnel of potential hazards. Additional IntelliZone awareness zones can be configured as needed and are customizable to specific equipment and applications. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 24 DO NOT DISTRIBUTE Engineering Safety Advancing Automation MX3-IZ Driver Overview The MSHA-approved Driver allows for tracking of multiple Locators. The Driver is machined from rugged polycarbonate and incorporates multi-color LEDs used for diagnostics and zone identifications. Operators Guide 10000050 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 25 User Guide DO NOT DISTRIBUTE Engineering Safety Advancing Automation MX3-IZ Locator Overview The MX3-IZ Locator should be worn by the operator at all times. The device has audible and visible alarms to alert the operator of zone breaches. The device has LEDs the also indicate zone breaches and errors on the system. An OLED screen displays the Locator status and is used in conjunction with the multifunction button to associate or dissociate with the machine. OLED Screen STATUS SCREEN (PRESS + HOLD) ASSOCIATE / DISSOCIATE (DOUBLE CLICK) Signal Strength and Battery Level System Status and Locator Operating Voltage When displayed, test using MX3-IZ Locator Tester Locator Identification Development Information Development Information This allows users to associate / dissociate themselves as an operator of a particular piece of machinery. In order to do so, there must first be an Initiation Zone configured using the IntelliZone System GUI (Graphical User Interface). Standing inside this zone, the user may associate or dissociate as operator by double-clicking the Locators push-button. Double-click again to confirm association / dissociation. There will be (2) quick audible signals confirming that the process was successful. If user requests association / dissociation but fails to confirm within
(10) seconds, the Locator will timeout and default to normal operation. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 26 DO NOT DISTRIBUTE Engineering Safety Advancing Automation User Guide MX3-IZ Driver LED States Under normal operation the user should see these LEDs on the Drivers. DEFINITION TIME DURATION (SECONDS) System operational; no Locator associated as operator 1.0 System operational; Locator associated as operator 1.0 Continuous 1.0 Warning Zone Breach Shutdown Zone Breach Proximity Protection System is bypassed If there is an error on the system, the Drivers will display these LEDs. DEFINITION TIME DURATION (SECONDS) Proximity Protection System is bypassed System Error MX3-IZ Locator Error MX3-IZ Driver Error (Diagnostic Warning); single LED MX3-IZ Driver Error (Diagnostic Error); single LED Continuous Continuous Continuous Continuous MX3-IZ Locator LED States Under normal operation the user should see these LEDs on the Locator. DEFINITION System Operation Normal Warning Zone Breach Shutdown Zone Breach TIME DURATION (SECONDS) 1.0 1.0 1.0 If there is an error on the system, the Locator will display this LED. DEFINITION System, Locator, or Driver Error TIME DURATION (SECONDS) Continuous 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 27 DO NOT DISTRIBUTE Engineering Safety Advancing Automation User Guide Emergency Stop Override The IntelliZone Proximity Detection System features an ESO (Emergency Stop Override). This function is only to be used in Emergency situations where the Proximity System must be bypassed. For Continuous Miners this feature is activated with the machines remote control. This mode has limited functionality in that it will only allow low speed tram. It is important that all miner operators and/or other personnel that come into contact with the system daily know how this process works in the event of an emergency. JOY C2C & DC Continuous Miner 1. Toggle and hold the ESO/MMO switch in the ESO position. 2. Toggle and hold the Pump switch . 3. Release the pump switch , but continue to hold the ESO/MMO switch in the ESO position. 4. Activate the tram functions and move the machine to safe location. 5. Release the ESO switch to resume normal machine operation. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 28 DO NOT DISTRIBUTE DO NOT DISTRIBUTE User Guide Engineering Safety Advancing Automation JOY JNA Continuous Miner 1. Toggle and hold the ESO/MMO switch in the position. 2. Toggle and hold the Pump switch and2ND/3RDswitchintheUPposion. 3. Release the pump switch and2NDswitch, but continue to hold the ESO/MMO switch in the ESO position. 4. Activate the tram functions and move the machine to safe location. 5. Release the ESO switch to resume normal machine operation. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 29 DO NOT DISTRIBUTE Engineering Safety Advancing Automation User Guide FCC Compliance US FCC Compliance Statements:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. This portable transmitter with its antenna complies with FCC/IC RF exposure limits for general population / uncontrolled exposure. 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 30 DO NOT DISTRIBUTE Engineering Safety Advancing Automation User Guide Canada IC Compliance / Canada tats IC conformit Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. En vertu des rglements d'Industrie Canada, cet metteur de radio ne peut fonctionner l'aide d'une antenne d'un type et le gain maximal (ou infrieur) approuv pour l'metteur par Industrie Canada. Pour rduire le risque d'interfrence aux autres utilisateurs, le type d'antenne et son gain doivent tre choisis afin que la puissance isotrope quivalente (e.i.r.p) rayonne ne dpasse pas ce qui est ncessaire pour une communication russie. This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada RSS exemptes de licence standard (s). Son fonctionnement est soumis aux deux conditions suivantes:
1) ce dispositif ne doit pas causer d'interfrences, et 2) ce dispositif doit accepter toute interfrence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil. MX3-IZ Locator IDs FCC ID:USK-10000615 IC ID:11898A-1000615 10002008 rev 0 Matrix Design Group, LLC | 3299 Tower Drive Newburgh, IN 47630, USA | 812.490.1525 | www.matrixteam.com Copyright 2013 Matrix. All rights reserved. Do not distribute without prior consent. 31
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2014-06-05 | 2405 ~ 2475 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2014-06-05
|
||||
1 | Applicant's complete, legal business name |
Matrix Design Group, LLC
|
||||
1 | FCC Registration Number (FRN) |
0015732803
|
||||
1 | Physical Address |
3299 Tower Drive
|
||||
1 |
Newburgh, Indiana 47630
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
H******@acbcert.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
USK
|
||||
1 | Equipment Product Code |
10000615
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
T****** H******
|
||||
1 | Title |
Director of Technology and Development
|
||||
1 | Telephone Number |
(812)********
|
||||
1 | Fax Number |
(812)********
|
||||
1 |
t******@matrixteam.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Matrix Design Group LLC
|
||||
1 | Name |
T**** A****
|
||||
1 | Physical Address |
3299 Tower Drive
|
||||
1 |
Newburgh, 47630
|
|||||
1 |
United States
|
|||||
1 | Telephone Number |
81285********
|
||||
1 | Fax Number |
81249********
|
||||
1 |
T******@matrixteam.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Matrix Intellizone MS3-IZ Locator | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power Output listed is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This filing meets the SAR threshold exclusion set forth in KDB447498 and therefore can be used in mobile/portable configurations. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
LS Research, LLC
|
||||
1 | Name |
R**** U********
|
||||
1 | Telephone Number |
262-3********
|
||||
1 | Fax Number |
262 3********
|
||||
1 |
r******@lsr.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2405.00000000 | 2475.00000000 | 0.0810000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC