Microtube Manager ver.3.0 Manual
< Rev. 1.0 >
Issue date : March 22, 2011 Maxell Seiki, Ltd. Contents 1APPLICATION SOFTWARE SUMMARY.................................................................................................2 2OPERATING ENVIRONMENT................................................................................................................2 3FUNCTION ...............................................................................................................................................2 4MAIN UNIT AND SUPPLIED ITEMS .....................................................................................................2 5RW .............................................................................................................................................................3 6INSTALLATION........................................................................................................................................4 6.1 6.2 INSTALLATION OF APPLICATION SOFTWARE......................................................................................... 4 INSTALLATION OF DEVICE DERIVER SOFTWARE................................................................................... 5 7HOW TO USE APPLICATION SOFTWARE ............................................................................................9 SCREEN............................................................................................................................................... 9 7.1 SETUP DATA TITLE (SET UP)............................................................................................................ 10 7.2 SETUP TUBE ID AND INITIALIZE DATA (INITIALIZE)......................................................................11 7.3 7.4 READ DATA (READ) .......................................................................................................................... 14 7.5 WRITE DATA (WRITE)....................................................................................................................... 16 SEARCH MICROTUBES (SEARCH)..................................................................................................... 18 7.6 7.7 EXPORT DATA (EXPORT).................................................................................................................. 19 IMPORT DATA (IMPORT)................................................................................................................... 20 7.8 7.9 EXIT AN APPLICATION SOFTWARE (EXIT).......................................................................................... 21 8UNINSTALL AN APPLICATION SOFTWARE ......................................................................................21 Microtube Manager ver3.0 Manual 1 1Application Software Summary Microtube Manager ver.3.0 is an application software for the Intelligent Microtube Management System that it is possible to manage data on max. 48 made-by-Maxell_Seiki Intelligent Microtubes (extra-cost option, hereafter microtube) in a rack through a Personal Computer (hereafter PC). 2Operating Environment
<Hardware>
PC with ports more than USB1.1 CPU: PC with 1.6 gigahertz (GHz) or higher processor clock speed recommended;
Intel Pentium/Celeron family or AMD K6/Athron/Duron family RAM: 1.0 gigabytes (GB) or higher recommended HDD: 4.0 gigabytes (GB) or higher of available space
<OS>
Windows XP SP3 / Vista / 7 (32bit version) 3Function
Reads/Writes data on microtubes
Setups TUBE ID
Exports data on microtubes to a CSV file
Imports a CSV file data to microtubes
Searches microtubes in a rack by a keyword
Customizes data titles 4Main unit and supplied items
Reader/Writer unit for Intelligent Microtube (hereafter RW)
Power cable
USB cable
Installation CD-ROM 1 piece 1 piece 1 piece 1 piece
- Application software
- Device driver software
- Manual (this document) Microtube Manager ver3.0 Manual 2 5RW Antenna USB connector Power Power cable slot Microtube Manager ver3.0 Manual 3 6Installation When installing Microtube Manager ver.3.0 and device drivers of RW, follow these steps.
* Please login as Administrator.
* Images are Windows 7. Install an application software before connecting RW to PC. 6.1 Installation of application software 1. Set an installation CD-ROM on PC. 2. Double-click setup.exe. 3. When Microsoft .NET Framework 4 Client Profile is not installed on your PC, installer installs Microsoft .NET Framework 4 Client Profile. Read the terms of the pending License Agreement and them click
[Accept].
* When Microsoft .NET Framework 4 Client Profile is installed on your PC, go to step 5. 4. Click [YES] because User Account Control is displayed.
* Except Windows XP.
* Windows may require a restart of the PC. In that case, restart and then double-click setup.exe again. 5. Click [Next] because MicroTube Setup Wizard is displayed. 6. When installing to a different folder, enter it or click [Browse]. Select whether install this application software for yourself or for anyone who uses the PC, and then click [Next]. Microtube Manager ver3.0 Manual 4 7. Click [Next]. 8. Click [YES] because User Account Control is displayed.
* Except Windows XP. 9. Click [Close]. Confirm that Microtube Management.exe icon is displayed on desktop. 6.2 Installation of device deriver software Firstly, Plug a power cable and a USB cable into RW. Next, plug a power cable into an outlet and then plug a USB cable into PC after turning front-mounted power button on. Install an application software before connecting RW to PC. Dont launch an application software. Power on: Green light Microtube Manager ver3.0 Manual 5
< Windows Vista / 7 >
1 When RW is connected with PC with USB cable for the first time, the driver software is automatically installed. Perform the following steps after the message Device driver software was not successfully installed in the right image is displayed. PC cannot install the driver software automatically because RW controls 6 parts by USB hub. 2 Click in the following order:
<Control Panel> -> <Hardware and Sound> -> <Device Manager>
3 RW is recognized as Other devices. Name: RFID R/W ME-LM1M9S-A10 with ! mark Quantity: 6 pcs 4 Right-click on RFID R/W ME-LM1M9S-A10 and then select Update Driver Software. 5 Click Browse my computer for driver software. 6 Supply Driver for WindowsVista_7 in the Installation CD-ROM and then click [Next]. Microtube Manager ver3.0 Manual 6 7 Windows Security is displayed, but click Install this driver software anyway. 8 Click [Close]. 9 Repeat installation of driver software 6 times. 1) When completing installation of driver software, TAG IC R/W unit is displayed on Device Manager. 2) When opening TAG IC R/W unit, 6 Coil-on-Chip RFID System are displayed. ? mark is displayed, but RW works normally.
* Part of Windows Vista PC and Windows 7 PC may not work normally. 3) When launching application software in a state of not completing installation of driver software correctly, error message is displayed. Make sure the driver software is correctly installed in 6 RW. Microtube Manager ver3.0 Manual 7
< Windows XP >
1. When RW is connected with PC with USB cable for the first time, Found New Hardware Wizard is displayed. Select No, not this time and then click [Next]. 2. Select Install the software automatically (Recommended) and then click [Next]. 3. Click [Finish]. 4. Repeat above steps 6 times. 1) Found New Hardware Wizard is displayed 6 times. Repeat above steps 6 times. 2) When launching application software in a state of not completing installation of driver software correctly, error message is displayed. Make sure the driver software is correctly installed in 6 RW. Microtube Manager ver3.0 Manual 8 7How to use application software Double-click Microtube Manager icon on desktop. Set optional microtubes in a rack for microtube before operating and then set a rack on RW antenna. 7.1 Screen Startup Menu RACK IMAGE Status Commands DATA
* Sample image that data is written. After reading data 1 2 3 4 5 6 7 8 A B C D E F
<Front>
<RACK IMAGE zoom>
Unwritable area Writable area Microtube Manager ver3.0 Manual
< DATA zoom >
9 7.2 Setup data title (SET UP) Able to setup titles of writable area. Default is as follows:
Uncustomizable title Customizable title
: TUBE ID / LASER ID
: RACK No. / POSITION SAMPLE / RESIDUE PLACE / STORED UPDATE / WORKER Customizable title 1 Click FILE(F) from the menu and then select SET UP(S). 2 Change titles because Setup Window is displayed. The number of available characters is up to 10 characters in the single-width and the sign. When cutting the number of active titles, click the left-box to remove the check mark.
* Kinds of sign: -, ., ,, /, :, *, ( and ) Even if the displayed titles are cut, the number of characters that can be input to the title column does not increase. (Max. 10 characters) Microtube Manager ver3.0 Manual 10 7.3 Setup TUBE ID and Initialize data (INITIALIZE) Use this function when managing serial numbers by yourself. Able to select operation from the following 2 patterns.
- ALL DATA(A) : TUBE ID setting + Data initialization
- TUBE ID(T) : TUBE ID setting
< TUBE ID(T) >
1 Click EDIT(E) from the menu and then select TUBE ID(T) from INITIALIZE(I). 2 Input the first serial number on Initial Tube ID No.(Microtube A1) and then click [OK]. Serial number of End Tube ID No.(Microtube F8) that adds 47 to the first serial number is set automatically. EX) Microtube A1: 100 -> Micortube F8: 147 1) TUBE ID is serial numbers. Order is as follows:
A1, A2, ->, A8, B1, B2, -> F7, F8 2) Input a serial number by the decimal number. 3) Writable serial number range on Microtube A1:
0 - 99999952 When an out-of-serial number is input, the error message is displayed. 3 Click [OK]. Microtube Manager ver3.0 Manual 11 4 Confirm that a rack is set on the antenna of RW. When clicking
[OK], RW writes TUBE ID. Able to confirm data because RW reads data automatically after completing INITIALIZE.
< ALL DATA(A) >
1 Click EDIT(E) from the menu and then select ALL DATA(A) from INITIALIZE(I). 2 Input the first serial number on Initial Tube ID No.(Microtube A1) and then click [OK]. Serial number of End Tube ID No.(Microtube F8) that adds 47 to the first serial number is set automatically. EX) Microtube A1: 100 -> Micortube F8: 147 1) TUBE ID is serial numbers. Order is as follows:
A1, A2, ->, A8, B1, B2, -> F7, F8 2) Input a serial number by the decimal number. 3) Writable serial number range on Microtube A1:
0 - 99999952 When an out-of-serial number is input, the error message is displayed. Microtube Manager ver3.0 Manual 12 3 Click [OK]. 4 Confirm that a rack is set on the antenna of RW. When clicking
[OK], RW writes TUBE ID and initializes data. Able to confirm data because RW reads data automatically after completing INITIALIZE. Only TUBE ID and LASER ID are displayed on DATA. Microtube Manager ver3.0 Manual 13 7.4 Read data (READ) When reading Intelligent Microtube data for the first time, the following window is displayed. 1 Reads data by clicking [READ].
* Only TUBE ID and LASER ID are displayed.
* As for the following images, data is written on Intelligent Microtube. When failing in reading Intelligent Microtube data, MICROTUBE DETECTED mark is not displayed on failed Intelligent Microtube. Please confirm that Intelligent Microtubes are set in a rack exactly and click [READ] again. Success Failure Microtube Manager ver3.0 Manual 14 2 After reading data, the result is displayed on RACK IMAGE. Data of 8 Intelligent Microtubes on A line is displayed on DATA.
* Selected line is displayed in light green. 3 When clicking an any mark in RACK IMAGE, the background color is displayed in orange and data of 8 Intelligent Microtubes in same line is displayed in DATA. At the same time, a selected data changes to the Edit mode. Default of DATA title:
TUBE ID / LASER ID / RACK No. / POSITION / SAMPLE / RESIDUE / PLACE / STORED / UPDATE / WORKER Edit mode Microtube Manager ver3.0 Manual 15 7.5 Write data (WRITE) 1 When selecting the Intelligent Microtube on RACK IMAGE that you would like to write data on with the mouse, an applicable line is displayed on DATA. 2 When clicking a cell on DATA that you would like to edit data, the background color of cell is displayed in white, and changes to DATA EDIT MODE. The available characters is up to 13 characters in the single-width and the sign.
* Kinds of sign: -, ., ,, /, :, *, ( and ). Selecting After edit Editing Image of edit 3 Finishes the edit of data by typing the Enter key, and the background color of cell is displayed in green. When resetting the change of data, select BACK(B) from EDIT(E). Able to return to previous data by one by clicking BACK(B). 1) When editing some items of data, repeat step 2 and 3. 2) Able to control step of cell with the mouse and the keyboard. Control with keyboard is as follows:
Up-and-down: Up-and down arrow Right: TAB or ENTER Left: SHIFT and TAB 3) To complete WRITE, perform next step. Microtube Manager ver3.0 Manual 16 4 When clicking [WRITE], RW writes data on the Intelligent Microtubes. When completing WRITE correctly, the background color on RACK IMAGE of Intelligent Microtube that data has been written is displayed in yellow. When failing in writing data, the background color of Intelligent Microtube is displayed in gray. In that case, check whether a rack is correctly set on the antenna of RW or the Intelligent Microtube is correctly put into a rack and then click [WRITE] again. 1) When confirming written data, click [READ] again. 2) Data is written in each line. 3) Able to setup titles of DATA with SET UP(S). Regarding the details of SET UP(S), please refer to 7.2 Setup data title (SET UP). 4) Unable to change LASER ID. Success Failure Microtube Manager ver3.0 Manual 17 7.6 Search microtubes (SEARCH) Able to search the positions of microtube in a rack by selecting a title from SEARCH AREA. 1 Select a title from SEARCH AREA. Edited titles are displayed. ALL searches a keyword from all titles. 2 Input a keyword into a search box. EX) When inputting DNA as a keyword, both of DNA-1 and DNA-2 match DNA as the result. 3 When clicking
[SEARCH], application software searches a keyword and displays the result. 4 When data matches, the background color of microtube in RACK IMAGE is displayed in red. Match Unmatch Microtube Manager ver3.0 Manual 18 7.7 Export data (EXPORT) Exports all microtube data in a rack as a CSV file. 1 Click FILE(F) from the menu and then select EXPORT(E). 2 Supply a destination folder, input a file name and then click [Save]. 3 Confirm that a rack is set on the antenna of RW. When clicking
[OK], RW reads data and exports the data. Able to open the data with software such as Microsoft Excel or Notepad. EX) CSV file image when opening data with Excel. Microtube Manager ver3.0 Manual 19 7.8 Import data (IMPORT) Able to write data of a prepared CSV file in one pass. 1 Click FILE(F) from the menu and then select IMPORT(I). 2 Supply a data file and then click [Open]. 3 Click [OK]. 4 Confirm that a rack is set on the antenna of RW. When clicking
[OK], RW imports data. 1) Impotable data must follow same data format as exported CSV file . 2) We recommend using a file that is saved in 7.7 Export data (EXPORT) as a CSV data format. 3) Dont delete the title written in the first line in CSV data format. Moreover, even if titles are changed, these are not updated with imported data. Regarding the change of title, please refer to 7.2 Setup data title (SET UP). Microtube Manager ver3.0 Manual 20 7.9 Exit an application software (EXIT) 1 Click FILE(F) from the menu and then select EXIT(C) or then click button on screen. 2 Click [Yes]. 8Uninstall an application software
< Windows Vista / 7 >
1 Click in the following order.
<Control Panel> -> <Uninstall a program>
2 Select MicroTube from the list, right-click on it and then click [Uninstall].
< Windows XP >
1 Double-click Add or Remove Programs in Control Panel. 2 Select MicroTube from the list and then click [Remove].
* Windows, Excel and Notepad are trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. For inquiries about Microtube Manager ver3.0, please contact authorized distributor for assistance. Microtube Manager ver3.0 Manual 21