MAXFOR Technology Inc. MAXFOR Technology 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Smart Gateway
(MFG-G300) Users Manual MQEP-22-04 ( 1 / 10 ) R.0 A4(210297mm) MAXFOR Technology Inc. MAXFOR Technology 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea MAXFOR Technology Inc. CONTENTS 1. Symbol Description and Definition ................................................................................................................ 3 2. Notice.............................................................................................................................................................................. 4 3. Introduction ................................................................................................................................................................. 5 4. Features ......................................................................................................................................................................... 5 5. Specification ................................................................................................................................................................ 5 6. Designation .................................................................................................................................................................. 7 7. Remote access method to MFG-G300 .......................................................................................................... 8 7.1 Access method to VNC Viewer ..................................................................................................................... 8 8. Installation.................................................................................................................................................................... 9 9. Maintenance ................................................................................................................................................................ 9 10. Contact information ............................................................................................................................................ 9 MQEP-22-04 ( 2 / 10 ) R.0 A4(210297mm) MAXFOR Technology Inc. 1. Symbol Description and Definition WARNING MAXFOR Technology 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Warning messages address situations that could result in injury or critical damage to the Gateway. CAUTION Caution messages address situations that could result in damage to the Gateway. NOTE Notes relate helpful information. DC Symbol Indicates the DC power. MQEP-22-04 ( 3 / 10 ) R.0 A4(210297mm) MAXFOR Technology Inc. MAXFOR Technology 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea 2. Notice Important matter The following document is not contractually binding. MAXFOR Technology Inc. reserves the rights to revise the document at any point, following the any potential successful upgrade of the product;
First-time user, or whomever responsible for the repairing of the product, must read this manual thoroughly before operation. For the product to perform at its best, repairing or maintenance must be under the directives of personnel of, or those appointed by MAXFOR Technology Inc. Limitation of Liability MAXFOR Technology Inc. will not be held responsible for any damages such as physical damages occurred on users, if the cause is the inappropriate use of the product against the manual description. MAXFOR Technology Inc. does not appoint any agency or men, the legal rights to represent the company regarding our business. MAXFOR Technology Inc. will not be held responsible for damages or legal prosecution, caused by sales or se of products not approved by us. Use provided adaptor. When using other adaptors, make sure to use proper rating and standard product. It may causes damage the equipment. WARNING Equipment listed in the data sheet allowed range of temperature, humidity and air CAUTION pressure in use. When used in an environment that exceeds the tolerance of the device can cause malfunction or failure. This equipment is indoor use and all the communication wirings are limited to inside CAUTION of the building. MQEP-22-04 ( 4 / 10 ) R.0 A4(210297mm) MAXFOR Technology Inc. MAXFOR Technology 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea 3. Introduction The MFA-300 is functions as a gateway to transmit data to server without going through PC being collected data from wireless sensor network. 4. Features Ubiquitous Sensor Network Gateway SAMAUNG S3C6410 (ARM core) 633MHz chip. Linux Kernel 2.6.x support. Ethernet, Serial, JTAG, USB, GPIO Connectors. USN to BcN Wireless interface. 5. Specification Item Specification MAIN Process SAMSUNG S3C6410- 667MHz Memory SDRAM NAND Flash Boot Flash 128 Mbytes 64 M bytes 4 Megabit OS Linux Kernel 2.6.x Remark ARM11 Core DDR2 533MHz 100Mbps Only Parallel GPIO 4 Ports USB HOST 1 Port Serial Console 1 Port RS232 2 Port RJ-45 1 Port On-Board JTAG Converter Interface LAN Debug LED Support Device Alarm Debugging 5 Bits POWER, STATE, LINK, Tx, Rx CDMA, WLAN Light & Sound RF Option Option Freq. band 2.405G -2.475GHz IEEE 802.15.4 MQEP-22-04 ( 5 / 10 ) R.0 A4(210297mm) MAXFOR Technology Inc. RF power Sensitivity Antenna
-55dBm - 8dBm
-102dBm Dipole Antenna Temperature Range System Operation Operating Storage
-20C - 50C
-20C - 50C Humidity Range 0~95% RH, non-condensing Power In 12V DC Power Out Alarm Port: 12V
, 200mA USB Port: 5V
, 500mA Consumption Dimension IP Code Buzzer Port: 12V
, 200mA 2.0A 185(W) X 130(D) X 45(H)mm IPXX Power source MAXFOR Technology 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Boost mode Receive sensitivity AC power adapter Input: 100-240VAC, 50/60Hz, 1200mA Output: 12VDC, 3.33A Model NO: GC99D040012 NOTE Specifications are subject to change without notice. MQEP-22-04 ( 6 / 10 ) R.0 A4(210297mm) MAXFOR Technology Inc. MAXFOR Technology 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea 6. Designation Description LED ( Power, STATE, LINK, Tx, Rx) ANTENNA(Dipole antenna) DC Jack & Power On Switch Ethernet RS-232 USB HOST 2.0 Expansion Port A4(210297mm) NO. 1 2 3 4 5 6 7 MQEP-22-04 ( 7 / 10 ) R.0 MAXFOR Technology Inc. MAXFOR Technology 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea 7. Remote access method to MFG-G300
- Remote access is used to confirm only sensor data and Set values is used to Default values. If you change the setting, remote VNC connection and data linkage can be a CAUTION problem. 7.1 Access method to VNC Viewer VNC Viewer Program Installation Run VNC Viewer and Connect Server VNC connection screen MQEP-22-04 ( 8 / 10 ) R.0 A4(210297mm) MAXFOR Technology Inc. MAXFOR Technology 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea 8. Installation
- Locate the Gateway in an area easily accessible by a technician.
- Avoid locations in which the Gateway will be subjected to vibration or rapid temperature fluctuations.
- Follow local regulations and site requirements. 9. Maintenance Cleaning
- Use a soft cloth and mild detergent to clean the device. Do not use paint thinner, benzene, solvent or strong detergent.
- Be sure to turn the power key off before cleaning the device.
- Only authorized service personnel should remove the cover of the unit. Storage
- Store the equipment in an area with moderate temperature and humidity.
- If the equipment is not to be used for a long time, it is recommended to protect it from dust, dirt or humidity.
- Keep it away from any heating source, direct sunlight, water vapor, or such environment as poor ventilation, excessive shock or vibration. 10. Contact information Web site: http://www.maxfor.co.kr MAXFOR Technonogy Inc..
: 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea POST No. : 449-823 TEL : +82-31-337-0486 FAX : +82-31-339-7126 MQEP-22-04 ( 9 / 10 ) R.0 A4(210297mm) MAXFOR Technology Inc. MAXFOR Technology 48, Banjeong-ro, Yangji-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea FCC Part 15.105 statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Part 15.21 statement Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. FCC Part 15.19 statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Body-worn Operation This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum 20 cm between the radiator and your body. This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter unless authorized to do so by the FCC. MQEP-22-04 ( 10 / 10 ) R.0 A4(210297mm)