all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
user manual | Users Manual | 4.46 MiB | September 12 2022 | |||
1 |
|
internal photos | Internal Photos | 1.20 MiB | September 12 2022 | |||
1 |
|
external photos | External Photos | 328.92 KiB | September 12 2022 | |||
1 |
|
label and location | ID Label/Location Info | 282.56 KiB | September 12 2022 | |||
1 |
|
SAR exemption | RF Exposure Info | 476.59 KiB | September 12 2022 | |||
1 |
|
agent letter | Cover Letter(s) | 278.85 KiB | September 12 2022 | |||
1 | antenna part | Parts List/Tune Up Info | September 12 2022 | confidential | ||||
1 | block diagram | Block Diagram | September 12 2022 | confidential | ||||
1 |
|
confidential letter | Cover Letter(s) | 140.72 KiB | September 12 2022 | |||
1 | operational description | Operational Description | September 12 2022 | confidential | ||||
1 | parts list | Parts List/Tune Up Info | September 12 2022 | confidential | ||||
1 | schematics | Schematics | September 12 2022 | confidential | ||||
1 |
|
test report | Test Report | 2.31 MiB | September 12 2022 | |||
1 |
|
test setup photos | Test Setup Photos | 802.49 KiB | September 12 2022 |
1 | user manual | Users Manual | 4.46 MiB | September 12 2022 |
Studio Software AWRC Training Manual A W R C AUDIOMETRY & BINAURAL REM/LSM IN ONE SYSTEM D-0125128-C DRAFT 1 0123 TV SD Product Services GmbH Ridlerstrae 65 80339 Munich Germany www.medrx-diagnostics.com 1200 Starkey Rd., #105, Largo, FL 33771 U.S.A. Toll Free: (888) 392-1234 (727) 584-9600 Fax: (727) 584-9602 Email: medrx@medrx-diagnostics.com MedRx's Authorized Representative in Europe DGS Diagnostics A/S Audiometer Alle 1 5500 Middelfart Denmark MedRxs Archived manuals are available at www.medrx-diagnostics.com/support/manuals-avant-software/archive D-0125128-C DRAFT 2 Contents Getting to Know Your MEDRX AWRC ...................................................... 4 Alternate Speaker Option MEDRX AWRC ................................................. 6 Transducers and Accessories .................................................................... 7 MedRx Charger and Probe Charging ........................................................ 8 Loading Calibration Files ........................................................................... 9 AUDIOMETER MODULE Studio Software Overview .............................. 10 Audiometry ............................................................................................. 11 Top Tool Bar ........................................................................................... 11 Assign Transducers ................................................................................. 12 Preparing for Testing .............................................................................. 13 Placing the Earphones on the Patient ................................................... 13 Sound Field Testing ................................................................................ 15 Performing Audiometric Testing ............................................................ 16 Pure Tone Audiometry ........................................................................... 17 Speech Audiometry ................................................................................ 19 Word Recognition (WR) .......................................................................... 23 QuickSIN ................................................................................................. 24 VRA MODULE (Optional) ........................................................................ 26 Tinnometer MODULE (Optional) ............................................................ 35 REM / LSM MODULE Studio Software Overview ................................... 45 Pairing AWRC REM Probes ..................................................................... 46 AWRC REM Probe Connections .............................................................. 47 Live Speech Mapping .............................................................................. 47 Top Tool Bar ........................................................................................... 47 Bottom Tool Bar ..................................................................................... 48 General LSM Options .............................................................................. 49 Positioning the Speakers ........................................................................ 51 Speaker Calibration ................................................................................. 51 Probe Tube Calibration ........................................................................... 52 Step-by-Step Guide to Live Speech Mapping .......................................... 53 Speech Mapping with Recorded Inputs .................................................. 54 Speech Mapping with Live Voice Inputs ................................................. 55 Running Speech Mapping On-Top ...................................................... 56 MedRx Live Speech Mapping Protocol ................................................... 56 Real Ear Measurements .......................................................................... 57 MedRx Real Ear Measures Protocol ........................................................ 58 Additional Tests & Features .................................................................... 61 How to Perform the RECD Task............................................................... 62 Measuring Acoustic Feedback ................................................................ 63 Hearing Loss Simulator ........................................................................... 64 Master Hearing Aid ................................................................................. 64 PRINTING ................................................................................................ 66 Rainbow Passage ..................................................................................... 68 EMC Precautions ..................................................................................... 69 Safety ...................................................................................................... 75 Symbols that may be used ...................................................................... 76 Recommended Procedures for Cleaning and Disinfection ..................... 77 Permissions (Optional) ............................................................................ 78 Technical Information ............................................................................. 80 Limited Warranty .................................................................................... 83 D-0125128-C DRAFT 3 This unit is a Type 1 HFAE audiometer that meets the requirements of both ANSI S3.6 and IEC 60645-1 and IEC 60645-2. These standards specify the required precision that the MedRx AWRCMEDRX AWRC does achieve. Measurement uncertainty is +/- 1 dB. This device and transducers are intended for use at test frequencies between 125 Hz and 16000 Hz. This unit meets the requirements of both ANSI S3.46 and IEC 61669. These standards specify the required precision that the MedRx AWRC MEDRX AWRC does achieve. The MedRx AWRC MEDRX AWRC is an electronic instrument intended for the testing of human hearing using both tone and speech audiometry. This device meets the specifications and tolerances for audiometers and standard reference threshold levels for audiometric transducers such as supra-aural, circumaural and insert earphones, bone vibrators, and loudspeakers as defined in ANSI S-3.6 and IEC 60645. The MedRx AWRC MEDRX AWRC conforms to the RoHS directive 2011/65/EU when used with the supplied accessories. This manual assumes that the system hardware, software and drivers are installed and working properly. Please refer to the Studio Software Installation Manual for assistance. The Installation manual is included in the original MEDRX AWRC packaging in PDF format. The scope of this manual is to get you up and running with your MEDRX AWRC System. Please consult the interactive Help System within the software for more detailed information of features and functionality. To access this tool, press the F1 key at any time, or click the Help icon or text menu with your mouse. Access these by clicking on the ? icon at the top of the screen. Select an item from the list in the Contents tab. Also refer to the Help files for test signal characteristics, analysis, equalization methods and the effects of analyzer settings on accuracy. D-0125128-C DRAFT 4 Getting to Know Your MEDRX AWRC The MEDRX AWRC (Audiometer and Real Ear Measurement combination) represents a new era of ultra-compact diagnostic audiometry and precision in-
situ verification for your office. Compact yet rugged, this PC-Based system is USB powered and supports current ANSI and IEC audiometric and Real Ear tests. The software includes targets for DSL v5.0 and NAL-NL2. A unique feature of the Real Ear Measurement System is simultaneous, binaural Live Speech Mapping, MedRxs in-situ method for getting the fitting right the first time, every time. The device performs Real Ear Measurements where measurements are performed directly on the client's ear. These measurements can be done with or without a hearing in place. The reason to perform Real Ear Measurements for hearing instrument fittings is that shape and size of an ear canal significantly influence a hearing instrument's performance. Knowing the sound intensity outside and inside the ear enables the practitioner to determine the actual amplification and output that the patient receives through the hearing aid and make the appropriate adjustments. instrument being MedRx AWRC Audiometer Intended Use Statement:
MedRx AWRC REM Intended Use Statement:
The MedRx Audiometer is intended to be used for the purposes of determining patient hearing sensitivity. It is intended to quantify the patient's level of hearing by presenting pure tone stimuli through specific transducers at different frequencies and at different sound pressure levels. In addition to tonal stimuli, the devices can also present language-specific stimuli in order to identify further legions of the patients auditory pathway and their ability to recall what is presented to them. MedRx AWRC Audiometer Target Treated Population:
The target population for audiometry assessment includes all ages. MedRx AWRC Audiometer Indication for Use Statement:
The MedRx Audiometer is intended to be used for the identification and etiology of hearing loss in patients of any age. It is intended to be used by an audiologist, ENT, hearing healthcare professional, or trained technician in a hospital, clinic, healthcare facility or other suitable quiet environment as defined in ANSI S3.1 or equivalent. The hearing aid analyzer is intended to be used for the purposes of correctly configuring and prescribing the audible sound levels from a hearing device/aid. It is intended to measure the internal effect of such device using small and thin probe microphones which can be placed in the patients ear canal to allow the clinician to objectively quantify the benefit and effect the device has on the patients hearing. These measures are useful in the fitting and prescription of acoustic hearing aids in correspondence with the information acquired during the patients hearing assessment. MedRx AWRC REM Target Treated Population:
The target population for audiometry assessment includes all ages. MedRx AWRC REM Indication for Use Statement:
The hearing aid analyzers are to be used by trained personnel only, such as audiologists, ENT surgeons, doctors, hearing healthcare professionals or personnel with a similar level of education. The device should not be used without the necessary knowledge and training to understand its use and how results should be interpreted. D-0125128-C DRAFT 5 Alternate Speaker Option MEDRX AWRC Notice! The Red & Blue adapters are included and must be removed to attach 18 gage (1.0mm) Free Field speaker wires and then reinstalled. To Install Free Field Speaker Wires:
Screw Driver Screw Driver Unplug both the Red & Blue connectors. Place a small flat head screw driver on the small orange tabs and push down while inserting a speaker wire into the opening then remove the screw driver. Be sure the wire is secure. Repeat until all the speaker wires are secured then plug both connectors into the device as indicated above. DC Power supply must be used when using passive Free Field speakers D-0125128-C DRAFT 6 Transducers and Accessories Make sure that the correct transducers are set in the software by right clicking any transducer button on the audiometry screen and left-clicking to change the transducer. Use the accessories provided with your MEDRX AWRC. Use of unapproved accessories is not recommended. IP30 insert Earphones Talkback Microphone Patient Response Switch USB Cable Power Supply Probe Microphones Supra-Aural Headphones Bone Conductor Operator Mic &
Monitor (may vary) DD450 High Frequency Earphones Probe Mic Hanger Probe Mic Charger NOTE: The MedRx Audiometer supports IP30 Insert earphones, 3A Insert earphones, DD45, TDH-39 or DD450 earphones and HDA 300 extended high frequency earphones. The standard configuration includes either IP30 Insert Earphones or DD45 earphones D-0125128-C DRAFT 7 MedRx Charger and Probe Charging The MedRx Charger is designed to charge the MedRx AWRC REM Probes though Qi charging. The MedRx Charger comes with a USB cable and wall adapter for power. The LED lights in the MedRx Charger are designed to display the charge level of the internal battery and the AWRC REM Probe batteries. MedRx AWRC probes can be inserted into either side of the charger. It is important that the back (gray side) of the probe face toward the center of the MedRx Charger to prevent damage and ensure charging occurs. MedRx Charger with AWRC Probes attached MedRx Charger LEDs display status of Batteries NOTE: The MedRx Charger has an internal battery which can charge the REM probes during transit. MedRx AWRC probes can also be charged with a USB-C cable. LED Color Indicators Blinking Battery is charging Green Battery is 66%, Yellow battery is between 66% and 33%
charged Red Battery is 33% charged D-0125128-C DRAFT 8 Loading Calibration Files Each MedRx Audiometer is calibrated in compliance with the ANSI S3.6 standard. This calibration procedure results in a series of files that the Audiometer software reads to keep the hardware in calibration. These files are supplied on a USB Stick. The final step before using your MedRx Audiometer to evaluate hearing is to load these device specific calibration files onto the computer used to operate the Audiometer device. 2. After a few seconds, a navigation box will appear. Navigate to the files you would like to load. Click Load (choose *.set or *.cal files). 1. With the MedRx USB Flash Drive connected, open the MedRx Studio software, enter the module you will be loading calibration files into and click:
More Icon (three vertical dots). Triangle Icon. Load Calibration (in pop-up). 3. When the files are finished being loaded, this message will appear:
Click OK to complete loading the calibration. D-0125128-C DRAFT 9 AUDIOMETER MODULE Studio Software Overview The MedRx Studio software can run stand-alone or from Noah System or the TIMS Noah-Compatible Office System. Launching the MedRx Studio Software Stand Alone Double click the MedRx Studio shortcut on your Windows Desktop. Noah Launch Noah. Select a patient Launch MedRx Studio module following Noah procedures. Basic Software Options Several options are available which allow the user to customize the MedRx Studio Software to meet their needs. Access these options by clicking the settings wheel in the top right menu bar. The MedRx Studio software main screen. Icons are selectable depending on your equipment. D-0125128-C DRAFT 10 The Main Screen settings allows you to set the default modules, database, print templates and more. If you have more than one MedRx product you can show/hide modules in the Main Screen settings. NOTE: Remember, more information is always available in the Interactive Help System by clicking the ? Icon in the top right corner of the software or pressing the F1 key. Audiometry Select AUD from the main menu. Top Tool Bar The Tool Bar icons have the following functions:
Start Talk Forward Show Monitor Save Session and Exit Save Session 1. 2. 3. 4. 5. Print 6. Show Journal 7. Show Settings 8. Show Help 9. More Options The More Options icons have the following functions:
1. Save the Current Session to a File 2. Open session from a file 3. Clear Data from Current Test 4. Open Calibration 5. Data Editor D-0125128-C DRAFT 11 Configuring the AUD Software Assign Transducers It is important to note that each module will have different settings available for customization. Enter the module and click the settings wheel to customize. The Audiometry module has unique settings for the module. To navigate the settings you will:
Select the group of settings from the header (1). Then choose the setting options from the left sidebar (2). The customization options will change based on the group and settings chosen in the main body (3). Option 1: On the General Options screen click Outputs to assign specific transducers to the audiometer outputs. Option 2: You can change transducers by Right-Clicking on any transducer icon on the Audiometry screen. The main body of the settings will have options for outputs shown and default transducer by output. Select the appropriate transducer for each output. To add or remove outputs, click the desired outputs to enable or disable transducer buttons on the audiometry screen. D-0125128-C DRAFT 12 Preparing for Testing Use the accessories provided with your MedRx Audiometer. Typical acceptable transducers are shown on page 6. Operator headsets for use with the MedRx Audiometer should have 32 ohms impedance and the speaker power should be at least 50 watts. Air conduction transducers for use with this device should have an impedance of 10 ohms. The speaker voltage should match the local mains voltage where the device is used. The Operator Headset with microphone is used by the device operator to communicate with the patient. The patient talks to the operator using the Talk-Back microphone. 2. Carefully compress the tip between your fingers to allow it to fit into the patients ear canal as shown. Do not roll the tip between your fingers. Placing the Earphones on the Patient Insert Earphones IMPORTANT: The foam tips used for the insert earphones are for SINGLE PATIENT USE ONLY. Do not attempt to wash and re-use them. 1. Place a new set of foam tips on the earphone tubes as shown. These tips are designed for single patient use and should not be washed and reused. NOTE: When removing foam tips after use, be sure the clear or black plastic tubing nipple remains attached to the long earphone tube. 3. Pull up and back on the patients pinna to straighten the ear canal. 4. Place the compressed foam tip deep within the ear canal. 5. When properly placed, the outer surface of the insert tip will be flush with the opening of the ear canal as shown. D-0125128-C DRAFT 13 Supra-Aural Headphones Placing the Bone Conductor 1. Place the headphones on the patients head so the center of the headphone is directly over the opening of the ear canal. 2. Adjust the headband so the headphones remain in place, but be careful not to make it so tight as to cause patient discomfort. High Frequency Earphones - AWRC & Tinnometer (Optional) 1. Place the earphones on the patients head so the center of the earphone is directly over the opening of the ear canal. Adjust the headband so the earphones remain in place, but be careful not to make it so tight as to cause patient discomfort. 1. Locate the mastoid process behind the pinna. This is the bony shelf just behind where the ear meets the head. 2. Carefully place the bone conductor on the mastoid process and hold it in place. 3. Place the headband over the head to the opposite temple. 4. Carefully and slowly loosen your grip to check if the bone vibrator and headband will stay in place. 5. If either moves, reposition until both the headband and bone vibrator are secure. D-0125128-C DRAFT 14 Sound Field Testing The Sound Field speakers (Free Field) should be connected using optional or user supplied amplifier and speakers. They should be calibrated annually as per ISO 8253-2, located at least 1 meter from the patient ear and at the same height. To Install Free Field Speaker Wires:
Notice! The Red & Blue adapters are included and must be removed to attach 18 gage (1.0mm) Free Field speaker wires and then reinstalled. Unplug both the Red & Blue connectors on the AWRC audiometer. Screw Driver Screw Driver Place a small flat head screw driver on the small orange tabs and push down while inserting a speaker wire into the opening then remove the screw driver. Be sure the wire is secure. Repeat until all the speaker wires are secured then plug both connectors into the device as indicated above. DC Power supply must be used when using passive Free Field speakers or performing High Frequency. Device Maintenance Annual re-calibration of the transducers used with the MedRx is recommended. There are no user repairable Audiometer components of this device. Refer to the recommended procedures for cleaning and disinfection in this manual. D-0125128-C DRAFT 15 Performing Audiometric Testing The screen shot below shows the controls which are available from the Audiometer main window. The sections of the manual that follow explain how to use these tools to perform hearing evaluations using your Audiometer. 1. Test Selection Tool Bar 2. Settings Selection Bar 3. Ear Selection 4. Output Selector 5. Test Type Selector 6. Tone Type Selectors 7. Display Options
(Frequency) 8. Test and Masking Interrupter, Routing Selector 9. Output Level Potentiometers 10. Response Options 11. Screen Option Tabs 12. Test Results 13. Legend 14. Discard, Edit, Copy and other options D-0125128-C DRAFT 16 Pure Tone Audiometry Pure Tone Audiometry measures the patients peripheral hearing sensitivity, or the softest levels they can hear pure tones at a variety of frequencies. These thresholds are plotted on a standard graph called an audiogram. The MedRx Studio software controls the hardware, stores the data (if running within Noah or TIMS) and prints a standard or custom audiogram report. Pure tone Audiometry can be performed via earphones or a Bone Conductor (Bone Conduction). Prerequisites:
Before performing audiometry, careful inspection of the ear canal should be performed. This is best done with Video Otoscopy. After ensuring the ear canal is clear, place the appropriate transducer on the patient. Pure Tone Audiometry via Earphones IP30 Insert Earphones, Eartone 3A Inserts or Supra-Aural Headphones 1. From the main Window, Click the AUD button. 2. By default, the Tone button will be selected once you enter the main Audiometry Screen. Other default settings (based on typical clinical practice and procedures) are:
a. Right Ear b. AC (Air Conduction) c. Tone Stimulus d. Continuous Tone 3. All defaults can be set in each module by clicking on the settings wheel. 4. Instruct the patient that they will hear several very quiet (soft) tones (beeps) and that they should signal (raise their hand, press the patient response button, etc.) as soon as they hear it. It is helpful to also say even if it seems very far away. 5. Begin at 1000 Hz in the Right ear (unless the patient reports better hearing in the left ear). 6. Present a tone at 60 dB by pressing the space bar or clicking the 7. Test button. If the patient does not hear the tone (does not signal), raise the level 5 dB using the up arrow on your keyboard and present again. 8. Repeat step 6 until the patient signals that they hear the tone. 9. When the patient signals they hear the tone, decrease the level by 10 dB and present the tone again. 10. Repeat steps 6 through 8 until the patient responds to a tone at the same level 2 times with the level ascending. 11. Using the right arrow key, change the test frequency to 2000 Hz and repeat steps 5 through 8 to establish the threshold at 2000 Hz. NOTE: If the threshold at 2000 Hz is more than 20 dB different (less than or greater than) the threshold at 1000 Hz, repeat steps 5 through 8 at 1500 Hz (the half octave between 1000 Hz and 2000 Hz). 12. Repeat steps 5 through 8 for 4000 Hz, 8000 Hz, 500 Hz and 250 Hz. 13. Repeat steps 5 through 11 in the opposite ear. NOTE: The software automatically calculates the 3-frequency Pure Tone Average (PTA) which is displayed above and inside the legend as follows:
D-0125128-C DRAFT 17 Pure Tone Audiometry via the Bone Conductor 1. Following the instructions on page Error! Bookmark not defined. (Need to add the appropriate markup), place the Bone Conductor on the mastoid process behind the ear with better air conduction thresholds as measured above. If the thresholds are equal, place the Bone Conductor on the mastoid process behind the right ear. 2. Establish bone conduction thresholds as described above (see 3. page Error! Bookmark not defined. (Need to add the appropriate markup), steps 5-8) for 1000 Hz, 2000 Hz, 4000 Hz, 500 Hz and 250 Hz. If the Bone Conduction (BC) threshold at a given frequency is less (better) than the Air Conduction (AC) threshold by 15 dB or more, you must confirm the threshold by performing masking. Masking for Pure Tone Audiometry To use the masking function on the AVANT Audiometer, follow the steps below:
1. Click the Masking button or press the m key. The button will appear grey (as shown) indicating that the masking is on. 2. Use your mouse or hold control and use the up and down arrow keys to adjust the Masking Level Slider to the appropriate level based on your preferred method of masking. 3. If you wish to maintain the balance of signal and masking
(for example, masking always 30 dB above the signal), click the Lock button after setting the masking and signal levels. 4. The default for pure tone audiometry is to deliver narrow band masking to the ear opposite the test ear. If you wish to use a different stimulus, or route the masking to the same or both ears, click on the settings wheel to the right of the Masking button. D-0125128-C DRAFT 18 5. Use your mouse to select the new masking type and routing for your specific application. 6. When you are finished making changes to the Masking, click X. Speech Audiometry Speech audiometry evaluates how well the patient can hear and understand speech. The typical test battery includes tests of speech threshold and tests of speech discrimination. The following sections detail how to perform these tests in MedRx Studio. Speech Reception Threshold (SRT) The Speech Reception Threshold (SRT) is defined as the lowest level at which the patient can repeat Spondee words with 50% accuracy. Spondee words are two syllable words with equal vocal emphasis on each syllable such as baseball or hotdog. Instruct the patient that they will hear a series of two-syllable words that will get quieter as the test progresses. They are to repeat the words as best they can, even if they sound very far away. If they are not sure of a word, they should take a guess. SRT is typically started 10-20 dB more than the patients Pure Tone Average, which is displayed on the top of the screen. Set the level of the test signal to 10dB above the PTA and follow the steps as follows:
1. From the MedRx Studio main screen, click the AUD button. 2. Click the SRT button located on the toolbar on the top left of the screen. 3. Click the W tab on the bottom right. 4. Use the folder icon and drop-down list to select Spondee Word Lists A&B or Child Spondee from the list. D-0125128-C DRAFT 19 5. Click the Play button or press the F9 key to present a word. The word will play through the chosen transducer as well as display on the screen. 6. 7. If the patient correctly repeats the word, click the Correct button or press F7. If the patient incorrectly repeats the word, click the Incorrect button or press F8. NOTE: F7 and F8 auto advance the playlist to the next word but will not play the next word. F9 plays the highlighted word. F10 advances to the next word and plays it. The score is calculated and displayed automatically. If the patient exceeds a 50% score at a given presentation level, stop the test and decrease the level by 10 dB and repeat the steps above. If the patient fails to achieve a 50% score after 6 words at a given level, stop the test, raise the level 5 dB and repeat the steps above. When the patient scores 50% at a given level, the test is complete. The software automatically plots the score on the SRT graph. Speech MCL & Speech UCL The patients most Comfortable Level and Uncomfortable Level for speech can be obtained while you are in Word Recognition (WR). 1. From the MedRx Studio main screen, Click the AUD button. 2. Click the WR button located on the toolbar on the top of the screen. 3. Click UCL or MCL. 4. Choose an input option. 5. If you selected File or CD*, select the track you would like to play for the test in the media player at the bottom of the screen. When you have selected your track in the media player, click play on media player or hit the spacebar to start. Adjust levels up or down with keyboard arrows or by clicking below the dB level at the bottom of the test slider or masking slider. NOTE: *CD function will only be displayed if you have a disc drive D-0125128-C DRAFT 20 6. To Input & Calibrate the Rainbow Passage in WR for MCL:
c. The Rainbow Passage is now part of the MedRx Studio Audio Files for future use. a. Press the small file folder on the top right of media player. Then select Browse in the speech material. d. Use the drop down in the media player and select track 10 Calibration (1000Hz). e. Click play or start signal. b. Select Rainbow Passage by double clicking twice. f. Then click the calibration arrow next to the UV meter. g. On the VU meter pop-up, press the slider calibration icon just below the VU meter. h. Adjust with mouse or arrow keys so that the blue bar stops over the black arrow and there is no red. D-0125128-C DRAFT 21 i. Click on the channel icon just below and to the right of the VU to switch channels. j. Repeat steps d - f for the remaining channel. Note: This calibration also needs to be done with any custom word list. 8. When using the Mic option adjust your input using the slider so that it is peaking at the black triangle under the VU meter. The VU meter is just below the Test button in MedRx Studio and will become active once you press Test. 7. When using the Mic or live voice option make sure you press the Test or space bar to begin. D-0125128-C DRAFT 22 Word Recognition (WR) Word Recognition (WR) is a discrimination, or recognition type test using speech as the stimulus. WR testing measures the percentage of mono-syllable words repeated correctly from a phonetically balanced list. Unlike the SRT test, the WR test is performed at a fixed intensity
(dB) level. Typical patients will score their best on WR testing at a level between 35 and 40 dB above their SRT. Before beginning the test, instruct the patient that they will hear a series of one-syllable words. They are to repeat the words the best they can. If they are not sure of a word, they should take a guess. 1. From the MedRx Studio main screen, click the AUD button. 2. Click the WR button located on the toolbar on the top of the screen. 3. Click the W tab on the bottom right. 4. Use the folder and drop-down list to select the desired Word List. The W-22 or NU-6 lists are good choices for typical adult patients. When testing children, the PBK lists are commonly used. More lists are available by calling MedRx Tech Support at 727-584-9600. 5. Click the Play button or press the F9 key to present a word. The word will play through the chosen transducer as well as display on the screen. 6. If the patient correctly repeats the word, click the Correct button or press F7. 7. If the patient incorrectly repeats the word, click the Incorrect button or press F8. NOTE: that the score is calculated and displayed automatically. The test is complete when all words in the list have been presented. The software automatically plots the score on the WR graph. 8. Click the Advance button >> or press the F10 key to present the next word. Score accordingly as described above. D-0125128-C DRAFT 23 QuickSIN The primary complaint of hearing-impaired persons is difficulty hearing in background noise. The measurement of SNR loss (signal-to-noise ratio loss) is important because speech understanding in noise cannot be reliably predicted from the pure tone audiogram (Killion & Niquette, 2000). The QuickSIN test was developed to:
1. 2. 3. 4. 5. 6. 7. Provide a one-minute estimate of SNR loss. Provide a quick way for clinicians to quantify a patients ability to hear in noise. Determine if extended high frequency emphasis improves or degrades understanding of speech in noise. Assist professionals in choosing appropriate amplification and other assistive technologies. Demonstrate that hearing aids with directional microphones improve speech intelligibility in noise. Provide a large number of equivalent test lists for use in clinical and research work. Provide information useful in counseling patients regarding realistic expectations. The screenshot above shows the key features of the QuickSIN test. 1. 2. 3. 4. 5. 6. Ear Selector Output Selector List Selector Track Display Track Control Legend D-0125128-C DRAFT 24 Performing the QuickSIN Test 1. From the MedRx Studio main screen, Click the AUD button. 2. Click the QuickSIN button located on the toolbar on the top of the screen. Present the test with earphones or in a sound field. The attenuator dial is set to 70 dB HL. For subjects with PTA hearing losses greater than 45 dB HL, the attenuator dial is set to a level that is loud but OK., this is done by the program automatically. A warning legend at the bottom of the window is shown if PTA is not available. Instruct the patient to repeat the sentences spoken by the target
(female) speaker. When testing in a sound field, have the patient hold the talkback microphone close enough so that responses are clearly audible to the tester. 1. Select a list from the List Selection Window one of the following two ways:
Click the list, then click Select. Or Double-Click the list number. 2. Play the first sentence in the list by clicking the Play button. Ask the patient to repeat the sentence. 3. To score the patients response: Click the check-box of each correct key word with your mouse. This will record the total number of correct key words in the score pull-down. 4. Click the next sentence and then click Play or click Next. This will advance & play. 5. Repeat steps 2-4 until all 6 sentences in the list have been played and scored. After all six sentences are scored, the following results are displayed:
Average SNR Loss in dB. Recommendations. D-0125128-C DRAFT 25 VRA MODULE (Optional) The VRA module is a Visual Reinforced Audiometry (VRA) module available in the MedRx Studio software. This is an optional module which must be licensed to activate. Contact your MedRx representative if you have questions regarding activation. Visual Reinforced Audiometry is a test designed for pediatrics when the child is too young for normal pure tone testing. This test is typically performed with children 6 months to 2-3 years of age. The VRA system utilizes cartoon videos reward system to help determine responses from the child. VRA Requirements The VRA system will require a PC that meets the MedRx recommended specifications:
Windows PC computer Intel i5 Quad Core or better 8 GB RAM or more Available USB 2.0, Compatible with 3.0 USB Graphics Adapter with 2GB Dedicated Video Memory 50 GB or more free hard drive space High Speed Internet Connection Windows 10 Professional 64-bit A PC that can handle from 1 to 4 monitors depending on configuration Download the iVRA app. The icon will look like this:
1. Go to the App Store app on your iPod or iPad. 2. Search for MedRx iVRA then tap the app. 3. Tap install. Consult with your local MedRx representative for assistance with installation. VRA Setup The VRA system will require initial setup in order to begin performing hearing tests. 1. Open the VRA module 2. Navigate to settings The VRA Test settings are determined inside of the iOS VRA application and cannot be adjusted in the MedRx Studio module. Screen setup will need to be determined prior to beginning a test. One Screen Setup Select 1 for Number of Presentation Screens. This will allow the rewards to be presented to only one screen. Click Identify Screens to determine which screen you would like as the reward screen. This should be the screen that will be in the testing area that the child will be present in. D-0125128-C DRAFT 26 Force Software Rendering should always be set to Yes to prevent delays in video presentation. Reset Screens will discard the selected screen set up. Reset Screens will discard the selected screen set up. Three Screen Setup Select 3 for Number of Presentation Screens. This will allow for three monitors to be used with the VRA Studio module. Two Screen Setup Select 2 for Number of Presentation Screens. This will allow for two monitors to be used with the VRA Studio module. Click Identify Screens to determine which screen you would like as the left and right reward screen. These should be the screens that will be in the testing area where the child will be tested. If there are two monitors in the testing area the left and right monitors should be assigned in relation to the childs left and right ear. If the primary screen is not being used for reward presentation this screen may keep the MedRx Studio software present or it may be hidden with Primary Screen Blackout. Force Software Rendering should always be set to Yes to prevent delays in video presentation. Click Identify Screens to determine which screen you would like as the left and right reward screen as well as the centering screen. These should be the screens that will be in the testing area where the child will be tested. Be sure that the left and right monitors are assigned in relation to the childs left and right ear. If the primary screen is not being used for reward presentation this screen may keep the MedRx Studio software present or it may be hidden with Primary Screen Blackout. Force Software Rendering should always be set to Yes to prevent delays in video presentation. Reset Screens will discard the selected screen set up. D-0125128-C DRAFT 27 VRA Test Settings Reward Video Setup Note that the Stimulus Length, Response Window, Non-Stimulus Rate, Reward Length, and Rewards Randomized are greyed out. These are to be adjusted within the iVRA App. Default Output, Default Signal, Default Pulse Type, dB Weighting, can be selected in this section. If Free Field Binaural is turned on, the thresholds will be presented and scored binaurally. If it is turned off, the thresholds will be scored per ear. Override Screensaver Timeout should always be set to Yes to prevent the computer timing out. In the Reward Video Setup, custom videos can be added and the order of video rewards can be edited. To add a new video, select the plus next to Add New Video. If you would like to recover a deleted MedRx video, they can be restored in the MedRx Video Folder (left folder). To load a custom video, click the Custom Video Folder (right folder). Select the video from your computer. Click Add to add the new video to your selection. Then click Save. D-0125128-C DRAFT 28 Connecting MedRx Studio and iVRA App To connect MedRx Studio and the iVRA app you will need to connect to the same wireless network. This can be a local network or a network with internet access. Once you have connected the devices to the same network, you will need to determine the IP address of the PC. To do so:
In Studio VRA Settings, Click Identify IP Address:
Studio will then list all available network connections. The VRA will need to be located on the same wireless network or Wi-Fi. On the iOS app, you can enter the computer name or Wi-Fi IP Address into the Server IP Address location NOTE: You cannot be connected to a VPN and use the iVRA. You must disconnect from the VPN to allow VRA connections. NOTE: You may use a local Wi-Fi network without internet access for the VRA connection. Enter the Computer Name or IP Address found in the Studio settings. The Computer Name or IP address will remain the same unless you change wireless networks or change PCs. The Port number entered will always be the same as shown in the screenshot: 39063. Click Connect in the iVRA app. After you click connect, you should see the Connection up, Handshake OK displayed in the iVRA app. You will need to click Connect at the beginning of every iVRA session. The MedRx Studio software will indicate that you have successfully connected when the iOS Icon in the VRA side bar changes from Red to Green. Disconnected Connected D-0125128-C DRAFT 29 VRA Settings The transducer selection is performed in MedRx Studio software prior to beginning the VRA test. All transducers are inherited through the AUD module. If you do not see a transducer you would like to use then you will need change the preferences in the AUD module. The MedRx Studio transducer selection will appear as below:
Type of tone (i.e. warble, pure tone, narrowband, continuous, pulsed) is also set up in MedRx Studio software prior to beginning the VRA testing. The settings for the VRA system are found in the iOS app. You can find these in the Settings tab of the app. Stim Length (s) Response Window (s) Settings Tab in the iVRA app How long the tones are presented in seconds How many seconds post stimulus in which to record a response Non-stim rate Reward Length (s) Rewards Randomized Masking Signal for Clinician How often are catch trials inserted Number of seconds to present the video reward Automatically randomizes video reward presentations during testing Determines the masking type presented to the clinician through the iOS device headphones Masking Past End of Stimulus(s) How long after stimulus end will Audio Feedback Audio Feedback Volume Double Tap (Grab Atten) the clinician be under masking Toggle feedback to be played though headphones during automatic testing (i.e. Threshold determination, levels, etc.) Level to which the clinician will hear feedback through the iOS device Present video reward to center monitor D-0125128-C DRAFT 30 iVRA Conditioning Mode The iVRA conditioning is initiated through the iOS app. The iOS app and MedRx Studio must be connected for the testing to begin. Once the iOS app and MedRx Studio are connected, navigate to the conditioning tab. The reward screens will turn black when the Start Conditioning button is clicked. Once the conditioning has begun, the iOS app will look like the left image. You may select presentation ear, frequency, level, and video reward. Note: You have the option in the Studio settings to fix presentation ear to binaural during free field testing. To present a stimulus you will swipe left on the presentation level in the center of the screen. To record a response swipe right, this will also display a reward. Rewards will always be displayed in conditioning mode. Change the presentation levels by swiping up or down on the presentation level that is displayed. If there is a centering screen, double tap the presentation level to present a video reward on the center screen. To exit the conditioning mode, you can hit back in the iOS app and immediately begin Manual and Automatic testing. If you would like to exit the conditioning mode from the PC, press the Shift + ESC key. D-0125128-C DRAFT 31 iVRA Manual Test Mode The iVRA manual test mode is initiated through the iOS app. The iOS app and MedRx Studio must be connected for the testing to begin. Once the iOS app and MedRx Studio are connected, navigate to the Tests tab. To begin manual testing, click the Manual button in the Test tab. When you click the Manual button, the reward screens will go to black and the testing will be ready. Once the manual test mode has begun, the iOS app will look like the left image. You may select presentation ear, frequency, level, and video reward. Note: You have the option in the Studio settings to fix presentation ear to binaural during free field testing. To present a stimulus you will swipe left on the presentation level in the center of the screen. To record a response swipe right, this will also display a reward. Rewards will only be shown if a stimulus was presented. Rewards are not displayed during catch trials. Change the presentation levels by swiping up or down on the presentation level that is displayed. To record a threshold, click Assign HL on the top of the screen. If there is a centering screen, double tap the presentation level to present a video reward on the center screen. Be sure to click Send in the top right of the iOS app when testing is complete. To exit the manual test mode, you can hit Quit in the iOS app. Be sure that your test results are saved prior to exiting. If you would like to exit the manual test mode from the PC, press the Shift + ESC key. D-0125128-C DRAFT 32 iVRA Automatic Test Mode To begin automatic testing, click the Automatic button in the Test tab. When you click the Automatic button, the reward screens will go to black and the testing will be ready. Once the automatic test mode has begun, the iOS app will look like the left image. You may select presentation ear, frequency, starting level, and video reward. Note: You have the option in the Studio settings to fix presentation ear to binaural during free field testing. level Presentation is Note:
automatically adjusted during the automatic test mode until threshold is determined. Only the starting level can be adjusted. Starting presentation levels can be changed by swiping up or down on the presentation level that is displayed. Once automatic testing has begun for a frequency, the levels can no longer be adjusted. These will adjust automatically based on recorded responses until a threshold is found. To present a stimulus you will swipe left on the presentation level in the center of the screen. To record a response swipe right, this will also display a reward. Rewards will only be shown if a stimulus was presented. Rewards are not displayed during catch trials. Thresholds are recorded automatically in this test mode. D-0125128-C DRAFT 33 If there is a centering screen, double tap the presentation level to present a video reward on the center screen. Be sure to click Send in the top right of the iOS app when testing is complete. To exit the automatic test mode you can hit Quit in the iOS app. Be sure that your test results are saved prior to exiting. If you would like to exit the Automatic Test Mode from the PC, press the Shift + ESC key. Video Only Mode Video Only Mode, is designed for use with a separate audiometer. Video Only Mode will control the screens only. No stimulus is being presented and no thresholds are being recorded during this type of testing. Swipe Left to display a video reward to the left screen. Swipe Right to display a video reward to the right screen. Swipe Up to display a video reward to all screens. Swipe Down to display a video reward to a center screen. To exit the automatic test mode you can hit Quit in the iOS app. VRA MedRx Studio Logging Logging of test sessions are available through MedRx Studio. To access the logs, click the Log tab in the MedRx Studio VRA sidebar. Testing information for both manual test mode and automatic test mode will be stored here. The following are what each log symbol means:
Correct Response No Response False Positive Catch Trial Success All log information will be stored in the session data. To recall the log information, open the session which contains the VRA results D-0125128-C DRAFT 34 Performing the Tinnometer Testing 1. From the MedRx Studio main screen, Click the Tinnometer button. 2. Add Clinic Information to Templates. Go up to Information in the top tool bar. 3. Enter Information into the pop-up form. Tinnometer MODULE (Optional) Purpose of the Tinnometer Tinnitus is experienced by millions of people worldwide. The Tinnometer is designed to mimic the sounds of tinnitus in order to provide an accurate and flexible tinnitus assessment. Tinnitus assessment increases patient rapport with the clinician when an equivalent tinnitus sound can be created. The Tinnometer can accurately create tinnitus sounds for fast and reliable tinnitus assessment. All test results should be used to help counsel the patient on their specific tinnitus and what the assessment has found. The Tinnometer test was developed to:
Break away from the traditional assessment with an audiometer. limitation of tinnitus Produce accurate and flexible sounds that mimic patient tinnitus. Provide extended frequency ranges to more accurately match tinnitus sounds. Decrease the time needed to complete a tinnitus assessment Standardize reporting needed when completing tinnitus assessment. Allow clinicians to save and recall prior tinnitus assessments. Provide general guidelines for implementing results into tinnitus sound therapies provided by leading hearing aid manufacturers. D-0125128-C DRAFT 35 Key features of the Tinnometer Main Screen:
1. Toggle Switch to Start/Stop stimulus 2. Sliders to control frequency, bandwidth, slope and tempo of the stimulus 3. Slider to control the intensity of the stimulus 4. Buttons used in determining tinnitus match, threshold and minimum masking level 5. Area where description of items will be displayed 6. Channels designed to present multiple types of tinnitus sound 7. A graphical display of the sounds being played for the patient. Stimulus and Audiogram are display in dB SPLsection D-0125128-C DRAFT 36 Interactions with the Patient are Controlled as Follows:
Step 1: Identify Patients Tinnitus 1. Patient Response Switch Indicator 2. Patient Monitor Microphone 3. Talk Forward 4. Undo 5. Toggle Help Section 6. Return to Studio There are 3 Steps Needed for Tinnitus Assessment with the Tinnometer 1. Identify patients tinnitus by frequency, bandwidth, slope and tempo. 2. Lower the identified tinnitus until patient threshold is reached. 3. Raise the tinnitus level above the identified tinnitus intensity
(widen bandwidth if needed) until the patient states they no longer hear the tinnitus. Play stimulus for 60 seconds to ensure masking is achieved. 1. Start by selecting the tinnitus type that has been described by the patient. This is an approximation of the tinnitus sound your patient hears. Tinnitus type will provide a starting frequency, bandwidth and slope to help speed up testing time. 2. Use the stimulus start/stop toggle to present the selected signal to the patient. D-0125128-C DRAFT 37 Step 2: Find Identified Tinnitus Threshold 3. Use frequency slider to match the pitch of the patients perceived tinnitus. 1. Use down arrow on your keyboard to lower stimulus until patient states they are no longer able to hear the tinnitus. 2. Click Threshold Level button. 4. Use volume slider to match patients perceived intensity of tinnitus. Step 3: Masking Tinnitus for 60 Seconds 5. Adjust bandwidth, slope and tempo (for pulsating tinnitus or prevention of adaptation) as needed. 6. Buttons to allow greater flexibility in bandwidth and slope of tinnitus. Allows the addition of high/low frequency sounds independently. 7. Allows for independent right/left volume control. 8. Press Tinnitus Level button once the patients tinnitus is matched. 1. Use volume slider to increase intensity of the stimulus until the patient states they are no longer able to hear their tinnitus. NOTE: Lower levels of masking may be achieved by increasing bandwidth of the masking stimulus. Pulsating the masking noise can prevent tinnitus adaptation. 2. Press the MML button and continue presenting stimulus until 60 second countdown ends. If patient begins to hear their tinnitus within the 60 seconds, raise intensity until masking is achieved and repeat number 2. D-0125128-C DRAFT 38 Tinnometer Modulation Tab The Tinnometer modulation tab is designed to simulate sound generators when hearing aid demonstrations cannot be performed. The following are controls used in Modulation. 1. Type of Modulation Sound 2. Speed of Modulation 3. Frequency of Modulation 4. Modulation Volume Range 2. Enter the modulation tab on the right side of Tinnometer software. To use the Modulation features within Tinnometer, you must first complete the three steps involved with tinnitus assessment. Once tinnitus assessment is complete, you can use modulation by:
3. Adjust the modulation stimulus with sliders as a counseling tool for the patient. 1. Activating the channel in which the tinnitus assessment was performed. D-0125128-C DRAFT 39 Tinnometer Audiometry Scan The Tinnometer Scan tab is designed for various forms of air conduction audiometry. There are three types of audiometry that can be performed with Tinnometer. You can access the forms of audiometry with the buttons located in the image to the left. Tinnometer Residual Inhibition (RI) The Tinnometer RI tab is designed for Residual Inhibition (RI) testing for a patients tinnitus. The controls in the RI tab are as follows:
A complete tinnitus assessment must be performed prior to performing testing in the RI tab. Once tinnitus assessment testing is completed, optional residual inhibition testing can be performed with the following steps:
1. Activating the channel in which the tinnitus assessment was performed. 2. Select the RI tab on the right side of the Tinnometer software. 1. Scale from 0-10 of tinnitus bothersome level. 2. Stop watch to begin stimulus. 3. Tracking of patients tinnitus bothersome level as a function of time. 3. Ask the patient the bothersome level of their tinnitus from 1 to 10 and mark their response. D-0125128-C DRAFT 40 4. Click the stop watch to begin the masking stimulus (stimulus to play for 60 seconds). Tinnometer Report Printing The Tinnometer has four reports available for printing:
Tinnitus Assessment Report. Manufacturer Guidance Report. Questionnaire Report. Channel Report. The following are common features found across reports:
1. To generate your report, select printer from the File menu. 5. Stimulus will play for 60 seconds and automatically stop at the 60 second point. 6. When the stimulus stops the patient must redefine their tinnitus bothersome level every 30 seconds. The bothersome level will increase with time. 7. The test continues until the bothersome level returns to pre-
test level. 2. Select the paper style you are printing. 3. Confirm all patient information is correct. 4. Choose your print preferences. 5. Change the zoom of your print preview. 6. Print your Report. D-0125128-C DRAFT 41 Tinnitus Assessment Report Tinnitus assessment reports are able to be generated after completing the three steps to tinnitus assessment. Once all steps are complete you are able to print a report 1. To generate your tinnitus assessment report, select printer from the File menu. 2. The Channel reports are the tinnitus assessment reports. Select the channel used for testing or All Channels when multi-channel testing is completed. 5. Print the Report. 3. Use the drop down box to select a diagnosis for the patient. 4. Comments can be entered in 4 separate lines with a maximum of 60 characters. D-0125128-C DRAFT 42 Manufacturer Guidance Report Manufacturer guidance reports are designed to provide hearing aid sound therapy guidance to a clinician based on tinnitus assessment results. Sound therapy is an option to tinnitus treatment. We encourage all clinics to develop a tinnitus treatment protocol that is in line with their tinnitus treatment goals. Manufacturer guidance generated by the Tinnometer is designed to be a starting point in sound therapy and each patient may differ in preferred sound. Manufacturer guidance reports are able to be generated after completing the three steps to tinnitus assessment. Once all three tinnitus assessment steps are complete you are able to print a report. 1. Select the manufacturer that you would like to have printed in your report. 2. To generate your tinnitus assessment report, select printer from the File menu. 3. Select Hearing Aid Guidance from the list of reports 4. Use the drop down box to select a diagnosis for the patient. 5. Comments can be entered in 4 separate lines with a maximum of 60 characters. 6. Print the report. D-0125128-C DRAFT 43 Graph Channel Report Questionnaire Report Graph channel reports will print a patient report which displays an image of the patients tinnitus with QR codes for YouTube videos that play a wind modulation noise nearest to their tinnitus. To generate the report you must:
Questionnaire reports will only show as an option once the questionnaire has been completed. Once a questionnaire has been completed and you are ready to print a report you must:
1. To generate your tinnitus assessment report, select printer from the File menu. 2. Select Graph Channel from the list of reports. Select the channel number which you used to match your patients tinnitus sound. 1. To generate your tinnitus assessment report, select printer from the File menu. 2. Select the name of the questionnaire you want to print from the list of reports. 3. Print the report. 3. Print the report. D-0125128-C DRAFT 44 REM / LSM MODULE Studio Software Overview The MedRx Studio software can run stand-alone, from Noah System or the TIMS Noah-Compatible Office System. Launching the MedRx Studio Software Basic Software Options Several options are available which allow the user to customize the MedRx Studio Software to meet their needs. Access these options by clicking the settings wheel in the top right menu bar. Stand Alone Double click the MedRx Studio shortcut on your Windows Desktop. Noah Launch Noah. Select a patient. Launch MedRx Studio module following Noah procedures. The MedRx Studio software main screen. Icons are selectable depending on your equipment. D-0125128-C DRAFT 45 The Main Screen settings allows you to set the default modules, database, print templates and more. Pairing AWRC REM Probes New AWRC devices will have the REM Probes pre-paired with the main unit. There will be no need to manually pair probes. Manually Pair Replacement AWRC Probes To pair replacement AWRC REM probes 1. Open Studio and Enter the REM or LSM module The Probe Indicator should show ? in the battery which indicates the software is searching for AWRC Probes 2. Plug in the new AWRC probe to USB power while pushing the power button to enter pairing mode. Release the button after 5 seconds. If you have more than one MedRx product you can show/hide modules in the Main Screen settings. NOTE: Remember, more information is always available in the Interactive Help System by clicking the ? Icon in the top right corner of the software or pressing the F1 key. 3. The Studio software will lightly fill the status bar when a connection is established D-0125128-C DRAFT 46 AWRC REM Probe Connections Live Speech Mapping NOTE: The AWRC REM Probe will only connect while MedRx Studio is in either the REM or LSM Module. Select LSM from the main menu. To connect AWRC REM probes to the baseboard 1. Open Studio and Enter the REM or LSM module The Probe Indicator should show ? in the battery which indicates the software is searching for AWRC Probes 2. Power on the AWRC REM Probes. LED will blink blue indicating probe is searching for connection. 3. The Studio software will lightly fill the status bar when a connection is being established 4. The AWRC is fully connected and ready for testing when the status bar has dark filled circles and battery status is available. 5. The AWRC REM Probe LED will turn green upon successful connection. Note: AWRC Probes will automatically turn off 30 seconds after powering on if MedRx Studio is not in either REM or LSM modules. Top Tool Bar The Tool Bar icons have the following functions:
1. On-Top Window 2. Tube Calibration 3. Speaker Calibration 4. Save Session and Exit 5. Save Session 6. Print 7. Show Journal 8. Show Settings 9. Show Help 10. More Options The More Options icons have the following functions:
1. Save the current session to a file 2. Open session from a file 3. Clear Data from Current Test 4. Probe Monitor 5. Microphone Calibration D-0125128-C DRAFT 47 Bottom Tool Bar The Bottom Tool Bar icons have the following functions: ___________________________________________________________________________ The Wrench icon displays options for:
1. Ear Selection 2. Stimulus Selection 3. Viewing Mode 4. Open Fit Function 5. Reset Averages 6. Probe Connection 7. Start & Stop buttons The Target Selection icon sets up:
1. Target type 2. Client information 3. Hearing aid parameters The Display icon sets up which target lines to display on the measurement screen. NOTE: Probe connections: empty circle not connected, light circle connecting, dark circle connected. NOTE: Remember that more information is always available in the Interactive Help System by clicking the Help Icon or pressing the F1 key. D-0125128-C DRAFT 48 General LSM Options Click the settings wheel in the top right menu bar. The Fitting tab sets the default fitting rule, client information, output and hearing aid parameters. The LSM tab sets your default view and default target levels. The General tab defines the default appearance of the Live Speech Mapping test environment. The Fitting tab also sets default NAL or DSL default settings. D-0125128-C DRAFT 49 The Signal tab sets the signals displayed on the Live Speech Mapping Screen. The REUR tab sets the view options. The Shown Tests tab sets the tests displayed in the Live Speech Mapping module. The REOR tab sets the view options. The Percentiles tab sets the view options. D-0125128-C DRAFT 50 Preparing for Testing Positioning the Speakers Proper positioning of the loudspeakers relative to the patients hearing aids is critical for making accurate and repeatable measurements. Seat the patient so their ear is between 19 and 39 inches from the loudspeaker. The speaker is designed to sit at desk height. When using Live Speech inputs, position the patient and loudspeaker as shown below. Speaker Calibration Open the Speaker Calibration screen by clicking the Speaker icon from the REM/LSM top menu bar. The speaker should be positioned in such a way that nothing blocks the path of the emanated sound in front and on the sides of the speaker. For example, positioning a speaker behind a monitor is incorrect and can severely affect its response at the measurement location. The speaker diaphragm should be at about the same level as the patient's ear and the reference microphone. Place the reference microphone on the patient about 1 meter from the speakers. Click on Start to begin the calibration and wait until it ends. Observe the response curve to flatten itself out. The darker curve is showing the response used by the equalization algorithm, the lighter curve is showing the current microphone input. Use of the powered speaker supplied with this device is recommended. D-0125128-C DRAFT 51 Probe Tube Calibration For reasons of infection control and reliability of results, MedRx recommends that a new probe tube be used with each patient. To ensure accurate measurements, it is necessary to calibrate the probe tube each time it is replaced. 1. Place a new probe tube on the probe micro-
phone port as shown. 2. Place the probe tube between the calibration nibs as shown. Be sure that the opening of the probe tube is centered on the opening of the reference microphone. In the MedRx Studio LSM software, click the Probe Tube Calibration icon. Position probe microphone between 19 and 39 inches from the loudspeaker and click Start Both to run simultaneously. The signal must be at least 70 dB to complete a valid calibration. If the screen prompt indicates the signal is too low, increase the volume on the loudspeaker or move the patient closer and restart the calibration. Repeat for the other probe if calibrated one at a time. Valid calibrations have the same approximate shape as the gray target curve. If the measured calibration curve differs greatly in shape or amplitude from the gray target curve, check or replace the probe tube and re-calibrate. If this does not correct the problem, contact MedRx technical support at
(888) 392-1234. The calibration values are available under the Calibration top menu icon. Click the More Options icon (3 dots) then click the Calibration icon. Return Probe Microphones to MedRx for annual re-calibration. Annual re-calibration of the MedRx REM+ Probe Microphones is recommended. There are no user repairable components on this device. D-0125128-C DRAFT 52 Step-by-Step Guide to Live Speech Mapping Ensure that the Audiogram is entered Before making Live Speech Mapping measurements, the patients pure tone audiogram must be available to the software. This can occur several ways:
1. The audiogram was automatically entered by MedRx Studio software when testing. 2. The audiogram was manually entered into the Noah audiogram module or Noah 4 software and saved. 3. The audiogram was entered using another manufacturers audiogram module. If none of these have occurred, you may manually enter the audiometric data into the REM software as follows:
1. Under General, then Shown Tests, select show Tone. 2. Select AUD module located at the top left of the software. 3. Using your mouse, select the test ear. 4. Select the test type AC. 5. Enter thresholds by clicking the intersection points with the mouse. (You may also enter the audiogram by selecting the audio tab in either the REM or HLS/MHA screens). 6. Repeat for UCL (Bone and MCL optional). 7. Repeat steps 3-5 for the other ear. After the audiogram is entered, click the LSM button to return to the MedRx Studio LSM testing screen. The Operator Headphone (optional) is used by the operator to monitor the signal being received by the probe microphone. D-0125128-C DRAFT 53 Speech Mapping with Recorded Inputs It is also possible to use an audio CD, such as the patients favorite music to perform Speech Mapping. The Studio software provides several digital audio files to use as a repeatable stimulus for Speech Mapping. These are accessed by clicking the File button on the right and then selecting the desired track from the pull-down menu in the audio player. Peak measurements are recommended. Once the desired pure tone or white noise track is selected, click the Start button to begin measuring. A pure tone or white noise will be presented and once it reaches the selected input level with the slide bar, the chosen track will play. When enough data is collected, click the Stop button to stop the recording and record the measurement. Select CD as an option under General and Signal. Select the CD button and then select a track. Use the sound level meter on screen to check the proper level. Adjust the output of the speaker to desired level using the sound level meter.
(Remember conversational speech is 65 dB at 1 meter). D-0125128-C DRAFT 54 The screen shot below provides an overview of all the tools and controls on the Live Speech Mapping screen. For more information on these features, please consult the Interactive Help system by pressing the F1 key or clicking the Help icon. Speech Mapping with Live Voice Inputs 1. Sound Level Meter 2. Settings Selection Bar 3. Ear Selection 4. Test Stimulus 5. Measurement Type Peaks LTAS 6. Open Fit Function 7. Reset Button 8. Probe Connection Status 10. Tools Tab, Target Selection Tab, and Display Tab 11. VU Meter 12. Target Area can be any of the following:
MedRx Modified Speech Spectrum DSL IO NAL-NL2 NAL-NL1 9. Start and Stop Buttons 13. Legend Using the microphone allows measurement of both the professionals voice and that of a third party e.g., the patients significant other or family members. To improve repeatability of measurements, it is recommended that the speaker read a standard passage such as the Rainbow Passage which is provided on page 69. NOTE: The screen shot above shows the MedRx Modified Speech Spectrum
(Canoe). It is also possible to use DSL IO or NAL-NL2 targets on this screen. Click the Setting wheel in the menu bar on the top right of the screen to select and configure these targets to meet the needs of your practice. D-0125128-C DRAFT 55 Running Speech Mapping On-Top The MedRx Studio system is tightly integrated with Noah, the industry standard for audiometric and fitting data storage and retrieval. The On-Top mode of the LSM software allows you to effortlessly alternate between measurement and fitting adjustments. From the MedRx Studio LSM main screen, click the On-Top Window. The LSM window will reduce in size and float on top of your fitting software. Use the text menus and green (start) and red (stop) buttons in the floating LSM window to preform Speech Mapping measurements. Completing the On-Top Mode Process Close the REM module by clicking the X button or the back arrow in the top left. Save the session as normally. MedRx Live Speech Mapping Protocol Unlike other products, the AVANT REM+ system places full control over the measurement environment firmly in the hands of the hearing care professional. The system is powerful, yet extremely flexible, allowing each provider to use Live Speech Mapping in a way that complements their practice style rather than compromising it. In order to get you up and running with the AVANT REM+ system, MedRx has developed the following protocol. This simple procedure has been found to be effective with both audiologists and hearing instrument specialists. After mastering the basic operation of the system utilized in this protocol, you are encouraged to further expand your use of Live Speech Mapping in your practice. Feature-specific help is available by simply pressing the F1 key or clicking on the Help icon or text menu. 1. Complete a careful otoscopic examination as instructed by the manufacturer of your otoscope. a. For MedRx Video Otoscopes, refer to the Help system within the software by pressing the F1 key or clicking the Help icon or text menu. 2. Basic Diagnostics. D-0125128-C DRAFT 56 a. Using your audiometer, measure and record the following values:
b. Pure Tone Air and Bone conduction thresholds. c. Narrow Band Noise or Pure Tone UCL at 500, 1000, 2000 and 4000 Hz. d. Other tests if needed in your practice or jurisdiction. 3. Position patient as described earlier in this manual on page 68
(Update). 4. Calibrate Probe Tube as described earlier in this manual on page 48
(Update). 5. Measure and place the probe tube in the ear canal. (Use chart to the left). 6. Complete a Live Speech Mapping measurement UNAIDED (RUER). a. ISTS or file input b. Peak Measures c. 1/3 Octave resolution 7. Carefully place the hearing instrument in the ear without disturbing the probe tube. 8. Complete a Live Speech Mapping measurement AIDED (LSM). 9. Using the On-Top mode, make any adjustments needed to the hearing instrument so that:
a. The LSM curve for Quiet Speech (50 dB) is at the bottom of the white modified speech spectrum (canoe). b. The LSM curve for Conversational Speech (65 dB) should be within the white modified speech spectrum. c. The LSM curve for loud sounds (80 dB) (very loud speech, clapping hands, etc.) is approximately 10 dB below the UCL curve. Real Ear Measurements In addition to Live Speech Mapping, the Avant REM+ supports all conventional Real Ear Measurements (REM). All these tests are accessed from the main REM screen. To begin, click the REM icon on the MedRx Studio main screen. D-0125128-C DRAFT 57 Real Ear Measurement Settings The screen shot below provides an overview of all the tools and controls on the REM screen. For more information on these features, please consult the Interactive Help system by pressing the F1 key or clicking the Help icon. tab at the top of the screen, and selection Help Topics. Select an item from the list in the Index tab, and click Display. MedRx Real Ear Measures Protocol 1. Complete a careful otoscopic examination as instructed by the manufacturer of your otoscope. a. For MedRx Video Otoscopes, refer to the Help system within the software by pressing the F1 key or clicking the Help icon or text menu. 1. REM Test Options 2. Settings Selection Bar 3. Ear Selection 4. Test Stimulus 5. Open Fit Function 6. Probe Connection Status 7. Time Indicator 8. Start and Stop Buttons 9. MSC Continuous Play 10. Tools Tab, Target Selection Tab, and Display Tab 11. Target Area can be any of the following:
a. DSL IO b. NAL-NL2 c. NAL-NL1 12. Legend Descriptions of the various Stimulus options are presented in the Help files under the topic Signal Types. Access these by clicking on the Help 2. Basic Diagnostics. a. Using your audiometer, measure and record the following values:
b. Pure Tone Air and Bone conduction thresholds. c. Narrow Band Noise or Pure Tone UCL at 500, 1000, 2000 and 4000 Hz. d. Other tests if needed in your practice or jurisdiction. 3. Position patient as described earlier in this manual on page 68
(Update). D-0125128-C DRAFT 58 4. Calibrate Probe Tube as described earlier in this manual on page 48
(Update). 5. Measure and place the probe tube in the ear canal. (Use chart to the left). 6. Complete a Real Ear Measurements UNAIDED (RUER). a. ISTS or file input b. Peak Measures c. 1/3 Octave resolution 7. Complete a Real Ear Measurement AIDED (REAG) 8. Using the On-Top mode, make any adjustments needed to the hearing instrument so that:
a. The REM curve for Quiet Speech (50 dB) is within 3 to 5 dB of all of the points on the prescription curve. b. The REM curve for Conversational Speech (65 dB) is within 3 to 5 dB of all of the points on the prescription curve. c. The REM curve for Loud Speech or sounds (80 dB) is approximately 10 dB below the UCL curve. 9. If measuring for Insertion Gain (REIR), then it is suggested that REUR (no hearing aid seated in the canal) and REAG (hearing aid seated in the canal and functioning) be completed. After the REUR is run, a curve will be plotted by the software on the REUG screen as well. It is suggested because REIR = REAG REUG. See the description of each measurement under REM tests in the manual, by clicking on F1 or by clicking on the question mark symbol at the top right of the window. Stimulus Signal Types Pure Tone: A pure sine wave. Crest Factor = 1.41 (3.0dB) Broadband Noise (BBN): Uniform random noise with normal
(Gaussian) amplitude distribution. Can be weighted to White, Pink, Speech ANSI, and Speech Byrne (see below.) Pseudo Random Noise (PRN): A "synthetic" broadband random noise. It is less uniform than BBN, has lower spectral density and random volleys. Can be weighted to White, Pink, Speech ANSI, and Speech Byrne (see below.) ICRA Noise: This stimulus was developed for measuring characteristics of non-linear instruments. The noise is weighted to Byrne LTASS. ISTS: (International Speech Test Signal) Initiated by European Hearing Instrument Manufacturing Association (EHIMA.) This signal is based on natural recordings of 21 female speakers in six different languages -
American English, Arabic, Chinese, French, German and Spanish. The signal is largely non-intelligible because of segmentation and remixing. The speech material was filtered to Byrne LTASS. Crest Factor: 9.23 (19.3dB) Rainbow Passage: Natural recordings of several voices reciting the rainbow passage. Shaped to Byrne LTASS. Broadband Noise Weighting White: This is essentially no weighting or filtering. The White Noise has flat power spectral density. Power at every frequency is equal. Because D-0125128-C DRAFT 59 the density of frequencies (individual cycles) raises with frequency, there is more energy in high octaves. required by the hearing aid to reach targets, but may result in under-
fitting at high frequencies. White-weighted noise can be used mostly for testing of equipment. It is not recommended to use it for hearing aid fitting, unless specified by the manufacturer. Crest Factor: BBN = 1.73 (4.8dB), PRN = 7.86 (17.9dB) Pink: The noise is filtered so its energy per frequency (power spectral density) is inversely proportional to the frequency. Each octave carries the same amount of energy. Comparing to White Noise, the Pink Noise energy drops approximately 3dB per octave. Pink-weighted noise can be used mostly for testing of equipment. It is not recommended to use it for hearing aid fitting, unless specified by the manufacturer. Crest Factor: BBN = 3.67 (11.3dB), PRN = 6.55 (16.3dB) Speech Byrne: The noise is approximately weighted to International Long Terms Average Speech Spectrum (ILTASS) as described in Byrne et. al., 1994. The noise with this weighting is preferred for hearing aid fitting because its spectrum is the best approximation of the spectrum of real human speech. Crest Factor: BBN = 4.22 (12.5dB), PRN = 3.47 (10.8dB) Speech ANSI: The noise is approximately weighted to ANSI S3.42 Speech Noise. The noise with this weighting can be used for fitting hearing aids. The slope of ANSI-weighted noise is not as steep as Byrne-weighted, so there is more power in higher octaves. This will result in less gain Crest Factor: BBN = 4.46 (13.0dB), PRN = 5.17 (14.3dB) To activate specific REM tests, click the buttons as follows:
Opens the audiometry data entry screen. Use this if audiometry has not been previously measured and entered into Noah. Real Ear Unaided Response - Measures the additive effect of the ear canals resonance to a stimulus. Reported as dB SPL of output. Real Ear Unaided Gain - Measures the additive effect of the ear canals resonance to a stimulus. Reported as dB SPL of gain. If a real ear unaided response (REUR) curve has been measured, the corresponding real ear unaided gain curve is automatically plotted to the REUG screen. The difference between the REUG and the REAG is called the Real Ear Insertion Gain (REIG). This Insertion Gain information is used to compare to the target gain curve selected for the client. The Real Ear Aided Response (REAR) is the sound pressure in the ear canal measured with the probe level microphone close to the eardrum and the operating hearing instrument inserted in the ear and turned on. ANSI defines REAR as the SPL, as a function of frequency, at a specified measurement point in the ear canal for a specified sound field, with the hearing aid in place and turned on. D-0125128-C DRAFT 60 five 90dB tone bursts at the following frequencies: 500Hz, 1000Hz, 2000Hz, 4000Hz, 5000Hz. Additional Tests & Features Real Ear to Coupler Difference (RECD) The Real Ear to Coupler Difference (RECD) is used to simulate real ear measurements by coupler measurements and is useful when fitting children or difficult to fit patients. RECD measurements can be conducted outside of a Hearing Instrument Test Box when using the optional MedRx RECD Coupler. The REAG is simply the REAR expressed as gain rather than SPL. Selecting REAG allows you to see the gain at each frequency for each of the REAR curves measured. REOR measures the effect on the natural external ear effects resulting from inserting an ear mold or a hearing instrument, before it is turned on, into the ear canal. The REOR is also referred to as Insertion Loss. REOR is also useful for validating the effectiveness of venting or canal length changes to the mold. The Real Ear Occluded Gain (REOG) is the difference in decibels, as a function of frequency, between SPL in the ear canal and SPL at the reference microphone at the entrance of the ear canal with the hearing aid in the ear and turned off. For each REOR measurement curve, the corresponding REOG curve is calculated and automatically plotted to the REOG screen. The REOG function is useful in determining the acoustic seal of a hearing aid, relative to a sound field outside the ear. Some clients report they seem like they are speaking in a barrel or feel blocked up. These are signs of a build-
up of self-generated low frequency energy in the ear canal. This excessive occlusion can be measured objectively in the Occlusion Effect task. The Real Ear to Coupler Difference (RECD) is used to simulate real ear measurements by coupler measurements and is useful when fitting children or difficult to fit patients. See the section on RECD later in this manual for more detail. The Maximum Power Output test measures hearing aid response at high input levels. The software measures MPO with ISTS multitalker noise played at 55dB and then The RECD values are used as a correction to coupler measures for that clients hearing instruments. By performing all subsequent measures in the coupler and applying the RECD corrections to the coupler D-0125128-C DRAFT 61 measures, the real ear factors are incorporated into the results. The resulting simulated measurements provide information to select and make adjustments to the hearing instrument and verify adjustments in the MedRx coupler rather than in the uncooperative clients ear. This is particularly important in the case of children, whose small volume ear canals enhance high frequency amplification more so than in average adults. This is an essential consideration in determining the maximum output of the hearing instrument. If RECD data is present, the software will display an option to choose between Ear or Coupler measurement on all Real Ear screens where measurements in a coupler are appropriate. There are two ways to measure the REAR response with optional RECD coupler: using an insert headphone or a hearing instrument. If a hearing instrument is used, its volume control setting and other parameters should remain the same for both REAR and coupler measurements. Set the volume control to moderate, and turn the compression and noise reduction circuits off. Using open-fit hearing aids for RECD measurements may result in invalid low and mid-frequency measurements because of insufficient gain at those frequencies. Please contact your hearing aid manufacturer for recommendations. How to Perform the RECD Task First, perform the REAR task to obtain a REAR curve. This can be measured with a hearing instrument or an insert earphone. REAR with a hearing instrument Adjust volume of the hearing instrument to comfortable listening level. Turn the compression and noise reduction circuits off. Position the client less than one meter from the speaker and facing the speaker. Place the hearing instrument and the probe microphone tube as for all REM measurements. Select START to open the measurement type selection screen. Choose the REAR with a Hearing Aid option. Select OK to begin the test and wait until it concludes. REAR with an insert headphone Place the probe microphone tube as for all REM measurements but use the insert headphone instead of a hearing instrument. Select START to open the measurement type selection screen. Choose the REAR with an Insert Headphone option. Select OK to begin the test and wait until it concludes. D-0125128-C DRAFT 62 Coupler Response When the REAR measurement is complete, you are prompted to perform a coupler response. NOTE: After measuring RECD, it is possible to perform Live Speech Mapping in the coupler as well. Look for the Measuring in option on the LSM screen. Attach the hearing instrument or the insert headphone (must be the same as in the REAR test) to the appropriate coupler and place the probe tube inside the coupler. If a hearing instrument is used, be sure to perform this measurement at the same volume control setting as the first measurement. Select START to open the measurement type selection screen. Choose the Coupler Response option or Use Stored to skip the measurement
(see note below.) Select OK and wait until the test completes. The calculated RECD curve is automatically displayed on the screen and is stored in memory for correction of subsequent coupler measurements made from the RECD function. NOTE: If the REAR and the coupler response were measured with the insert headphone, the program saves the coupler response curve for later use. In this case to obtain another RECD, only REAR with insert headphone measurement is necessary. This is possible because the coupler response does not change provided that neither the coupler nor the insert earphone has changed. Measuring Acoustic Feedback Feedback (whistling, howling) is one of the most common complaints of hearing instrument users. Even though many modern hearing instruments have sophisticated feedback management systems, knowing exactly where the feedback is occurring can greatly reduce the time required to resolve the problem. The AVANT REM+ system does an excellent job measuring and displaying acoustic feedback. 1. Place the calibrated probe tube in the ear canal as instructed previously. 2. Place the hearing instrument in the ear without disturbing the probe tube. 3. Begin a Live Speech Mapping session as instructed previously. 4. When feedback is present, click the Start button. 5. Acoustic feedback appears as a large spike in the LSM response. D-0125128-C DRAFT 63 If a more specific frequency analysis of the feedback is desired, change the resolution of the system to 1/24 octave and adjust the smoothing in the General LSM or REM settings menu. This image shows the similar feedback as above at 1/24 octave, smoothing 1. Using this information, make any necessary adjustments to the hearing instrument to reduce or remove the feedback. Hearing Loss Simulator The Hearing Loss Simulator demonstrates the effect of the clients hearing loss for the significant third party. The program attenuates an input signal to simulate the audiogram. The third party listens to the free field speakers. The Hearing Loss Simulator requires the clients Audiogram data. This data can be manually entered in the Audio screen of this or any other task. How to use the Hearing Loss Simulator 1. Select the Hearing Loss Simulator tab on the toolbar. 2. Enter the Audiogram values manually if the data is not automatically imported to this screen. 3. Select the input signal type: File or CD. Select the track and the Play button on the control panel. The HLS output is directed to the free field loudspeakers. 4. Select Simulate to turn on the simulation of the client's hearing loss. Deselect Simulate to present the stimulus as a normal hearing person would perceive the sound. Toggle between these selections as necessary. 5. The Reset option restores the audiogram to the original state. Use this option if you have modified the audiogram while in the simulate mode but want to undo the changes. The changes to the Audiogram that are made on the HLS screen are temporary and will not affect the client's original audiometry record. 6. A volume control adjustment bar allows modifying the audio for manual adjustment of the output level of the free field speakers. This allows the practitioner to demonstrate improvements to hearing loss with amplification or what happens when further hearing loss occurs. 7. To stop the playback, select the Stop button on the player. Note: It is recommended you use a variety of tracks from the list to demonstrate the hearing loss. Master Hearing Aid Master Hearing Aid is an alternative to using a stock hearing aid to demonstrate the benefits of amplification to an inexperienced user. The system applies the fitting rules by default to the patient's audiogram and simulates a hearing aid. The patient listens to this signal through the headphones. Options for editing the gain applied to the audiogram are provided. About the Master Hearing Aid Display The Master Hearing Aid screen displays a graph with dB Gain on the vertical axis and Frequency in Hz on the horizontal axis. The plot on the graph represents the gain applied to the patients Audiogram. The NAL-
D-0125128-C DRAFT 64 RP is applied by default. A new rule can be selected from the list on the right side of the display. A volume adjustment bar allows for manual adjustment of the output level. The control panel on the right of the display provides options for input signal source and the task icons for Normal and Simulate. The Master Hearing Aid applies gain separately for each ear. If audiogram values are entered for the left and right ear, the selected fitting rules will be applied to each ear separately. Different rules may be entered for each ear (i.e. NAL-RP for left ear and BERGER for right ear). If an audiogram is entered only for one ear, the gain will not be adjusted for the opposite ear and the sound for that ear will be normal. If Binaural mode is selected, the sound will be heard from both channels (left and right). If Monaural mode is selected, the sound will be heard only from the channel corresponding to the active ear when the channel for the opposite ear will be muted. Input signal File allows the user to play sound files. The program supports MP3 and WAV files and comes with a preset MedRx Sounds Sensations set of files. After the option is activated, use the player panel to control the playback. CD allows the user to play music CDs. After the option is activated, use the player panel to control the playback. How to use the Master Hearing Aid:
1. Select the Master Hearing Aid (MHA) icon from the main screen. 2. Enter the Audiogram values manually if the data is not input signal through to the automatically imported to this screen. 3. Select the input signal type: File or CD. 4. Select Monaural or Binaural. 5. Select the Simulate icon to modify the input signal according to the selected rule. This selection allows the patient to hear the benefits of amplification. Deselect the Simulate icon which will send the inserts without modification. The patient is listening to the signal without any amplification benefit. Toggle between these two selections as necessary. If the simulated frequency response needs to be adjusted based on feedback from the patient, manually edit the response by clicking on the gain curve at the desired frequency and new gain level. The gain curve of the selected test ear on the control panel can be edited. To edit the other ear, click the appropriate test ear icon on the control panel first. 6. Hint: Use the track return icon on the player control panel to replay one track continuously. The Reset option restores the rule to the original state. Use this option if you have modified the rule but want to undo the changes. D-0125128-C DRAFT 65 PRINTING Printing within the MedRx Studio software. You can use the templates provided at installation or create your own templates to suit your needs. Icons in the Print Window To Use an Existing Print Template 1. Click the print icon in the top tool bar or hold down the Ctrl key and click the P key on your keyboard. 4. Click the print icon. 1. Create a new template. 2. Preview template icon. 3. Print template icon. 4. Select the template you would like to use. 5. Shortcut to templates folder on your desktop. 6. Studio Help icon. 7. Edit the template with the pencil icon. Editing a template will open the print editor and allow you to adjust print elements. 8. Duplicate existing templates icon. 9. Delete template icon. 2. Select the template you would like to use. 3. Click the print preview icon to see the patients data
& images on the template before printing. 5. The printer options box will pop-up. 6. Click print. 7. Or click Ctrl+Shift+P to print the modules default template. D-0125128-C DRAFT 66 Create New Print Templates 1. Select the printer icon. 2. Select the + icon to create a new template. 3. Name the template you are creating. 4. Choose page orientation. 5. Use the drop-down menu to choose the size of paper you will be using. 6. 7. In the bottom left, Page Zoom will allow you to zoom in/out of the template for easier editing. In the bottom left, the Page Margin is set by default to the ideal level. Adjusting this will determine how far items will print from the edges. 8. Drag and drop elements onto the page to create your template. a. You can combine data from multiple modules into a single template. b. Elements may overlap and will stack/cover previously added elements. c. Certain elements will have settings that can be adjusted after dropping onto the page. d. You can resize all elements. The contents of each element will resize within the box depending on the amount of data in the element. 9. Use the + button to add additional pages if needed. 10. After template completion, use the Save, Save As, Preview and Print Icons for your template. a. Saved templates will be available for future sessions. b. Print a template to ensure that all elements print as expected. D-0125128-C DRAFT 67 Rainbow Passage When the sunlight strikes raindrops in the air, they act like a prism and form a rainbow. The rainbow is a division of white light into many beautiful colors. These take the shape of a long round arch, with its path high above and its two ends apparently beyond the horizon. There is, according to legend, a boiling pot of gold at one end. People look, but no one ever finds it. When a man looks for something beyond his reach, his friends say he is looking for the pot of gold at the end of the rainbow. D-0125128-C DRAFT 68 EMC Precautions MedRx AWRC should be operated only in a professional healthcare facility by trained professionals with education and/or training in the field of audiometry. Further the equipment cant be used in a residential environment. The EMISSIONS characteristics of this equipment make it suitable for use in industrial areas and hospitals. If it is used in a residential environment this equipment might not offer adequate protection to radio-frequency communication services. The user might need to take mitigation measures, such as relocating or re-orienting the equipment. BLE Uses 40 channels with a channel spacing of 2MHz in the 2.4GHz ISM band. This band ranges from 2402 MHz (Channel 0, logical channel 37) to 2480 MHz (Channel 39, logical channel 39). Logical Channels 37,38 and 39 are the advertising channels and channels 0 to 36 are the data channels. The three advertising channels are arranged in the frequency band so they cannot be disrupted by Wi-Fi channels. As a basic safety features the device is designed in such a way that the output from the transducer never goes beyond 80db irrespective of the short-term disruptions that may occur. The transmit power in BLE lies between -20dBm and 20dBm The MedRx AWRC needs special precautions regarding EMC and needs to be installed and put into service according to the following EMC information. List of all cables and maximum lengths of cables, transducers and accessories:
Transducer / Accessories Maximum Cable length USB Cable Insert Earphones Bone B-71 All Headsets All Microphones REM Probe All Speakers 3 meters 2 meters 2 meters 2 meters 2 meters 2 meters 3 meters D-0125128-C DRAFT 69 Warnings!
The use of accessories, transducers and cables other than those specified, with the exception of transducers and cables sold by the manufacturer of the MedRx AWRC as replacement parts for internal components, may result in increased emissions or decreased immunity of the MedRx AWRC. The MedRx AWRC should not be used adjacent to or stacked with other equipment and if adjacent or stacked use is necessary, the MedRx AWRC should be observed to verify normal operation in the configuration in which it will be used. The MedRx AWRC may be interfered with by other equipment, even if that other equipment complies with CISPR emission requirements. The MedRx AWRC does not have life supporting function. Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the MedRx AWRC, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result D-0125128-C DRAFT 70 Guidance and manufacturers declaration electromagnetic emissions Guidance and manufacturers declaration electromagnetic immunity The MedRx AWRC is intended for use in electromagnetic environment specific below. The customer or the user of the MedRx AWRC should assure that it is used in such an environment. The MedRx AWRC is intended for use in electromagnetic environment specific below. The customer or the user of the MedRx AWRC should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment -
guidance Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance RF emissions CISPR 11 Group 1 The MedRx AWRC uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. Class A Non applicable Non applicable The MedRx AWRC is suitable for use in all establishments other than domestic and those directly connected to the public low-
voltage power supply network that supplies buildings used for domestic purposes. RF emissions CISPR 11 Harmonic emissions IEC 61000-3-2 Voltage fluctuations /
flicker emissions IEC 61000-3-3 Electrostatic discharge
(ESD) IEC 61000-4-2
+/- 8 kV contact discharge
+/- 8 kV contact discharge
+/- 2, 4, 8
&15kV
+/- 2, 4, 8
&15kV Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%. air discharge air discharge Electrical fast transient /
burst
+/- 2 kV for power supply lines
+/- 2 kV for power supply lines
+/- 1 kV for input /
output lines
+/- 1 kV for input / output lines NA NA IEC 61000-4-4 Power frequency
(50/60 Hz) Magnetic field IEC 61000-4-8 Mains power quality should be that of a typical commercial or hospital environment. Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. D-0125128-C DRAFT 71 Guidance and manufacturers declaration electromagnetic immunity The MedRx AWRC is intended for use in electromagnetic environment specific below. The customer or the user of the MedRx AWRC should assure that it is used in such an environment. Immunity test IEC 60601- test level Compliance level Electromagnetic environment - guidance Portable and mobile RF communications equipment should be used no closer to any part of the MedRx AWRC, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance:
Conducted RF IEC 61000-4-6 0.15 - 80 MHz 3 Vrms & 6Vrms in ISM Band 1 kHz AC Mains 0.15 - 80 MHz 3 Vrms & 6Vrms in ISM Band 1 kHz AC Mains d = 1,17 Radiated RF 3 V/m 3 V/m IEC 61000-4-3 80 MHz to 2,5 GHz d = 1,17 80 to 800 MHz d = 2,33 800 MHz to 2,5 GHz Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey a, should be less than the compliance level in each frequency range b. Interference may occur in the vicinity of equipment marked with the following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency ranges applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the MedRx AWRC is used exceeds the applicable RF compliance level above, the MedRx AWRC should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the MedRx AWRC. b. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.m. D-0125128-C DRAFT 72 PPP MedRx AWRC Baseboard and MedRx Wireless REM Probe ISED non-interference disclaimer This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas license-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) Lappareil ne doit pas produire de brouillage;
(2) Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. MedRx AWRC Baseboard ISED RF Exposure statement This equipment complies with ISED RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm (7.6 inches) between the radiator and any part of your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Pour se conformer aux exigences de conformit ISED RSS-102 RF exposition, une distance de sparation d'au moins 20 cm doit tre maintenue entre l'antenne de cet appareil et toutes les personnes. Lanceurs ou ne peuvent pas coexister cette antenne ou capteurs avec dautres. MedRx Wireless REM Probe ISED SAR exemption statement RF output power is 5 mW which falls below the ISED SAR exemption limits for a device with a separation distance of 86 mm from the human body. These exemption limits are in accordance with ISED RSS-102, Section 2.5.1. D-0125128-C DRAFT 73 MedRx AWRC Baseboard and MedRx Wireless REM Probe FCC compliance statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Please note that changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. MedRx AWRC Baseboard FCC RF Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, this equipment should be installed and operated with minimum distance 20 cm (7.6 inches) between the antenna and your body during normal operation. Users must follow the specific operating instructions for satisfying RF exposure compliance. MedRx Wireless REM Probe FCC SAR exemption statement RF output power is 5 mW which falls below the FCC SAR exemption limits for a device with a separation distance of 86 mm from the human body. These exemption limits are in accordance with FCC CFR 47 2.1093. D-0125128-C DRAFT 74 Safety Regarding electrical safety, this device is designed to be used only by professionals Storage temperature range at least from -20C to 50C and humidity level from 10%
in the hearing healthcare industry. to 90%. It is Class II Medical Electrical (ME) equipment that is part of an ME system. This device provides Type B protection
(Type B equipment, Type B applied part) This device is not protected from ingress of water. Power is supplied by an un-
grounded mains power cable to a medical grade power supply and also supplied by the USB cable connected to a computer. The USB computer power must be able to supply at least 500mA at the standard USB voltage. Power is supplied by the USB cable connected to a computer. A USB Optical Isolator, with a minimum of 1500V AC isolation should be placed in-
line between the computers USB connection and the MedRx device. The Optical Isolator should be powered by a power supply that conforms to IEC 60601-1. The computer, Optical Isolators power supply and the speakers power supply should be connected to the Medical Grade isolation transformer that conforms to IEC 60601-
1. Follow the manufacturers instructions for installation and use. All connected equipment provides 2 MOPP per IEC 60601-1. This device is to be operated on non-conductive surfaces only. The computer used with this device should conform to the requirements of IEC 60601-1. A MULTIPLE PORTABLE SOCKET-OUTLET or extension cord shall not be connected to the system. The device warm-up time is less than 5 minutes. Use only the 15 VDC, 2A medical power supply supplied with your MedRx AWRC, CUI ETMA150200UD-P5P-IC. The power supply cable should always be accessible in order to disconnect it from the supply mains. Do not connect items that are not specified as part of the system. The use environment should be between 10C and 35C
, humidity within 30% to 90%
and an atmospheric pressure range from 80 kPa to 104 kPa. All components with patient contact are made of bio-compatible materials. This device does not produce any adverse physiological effects. Install the device as directed by this manual to achieve optimal use. Clean accessories per the cleaning instructions prior to use. No Sterilization is required for components of this device. However, new probe tubes and new foam inserts are needed for each patient where applicable. Cleaning of the device and accessories should follow the procedure outlined below. The device is not intended to be operated in an environment with anesthetics, oxygen or NO. It is not an AP or APG device. This ME System is not intended for use with flammable anesthetics. This device uses Type B application parts temporarily placed on the patient during testing. They are nonconductive and can be immediately withdrawn from the patient at any time. The device is intended for continuous operation. The computer and the MedRx device or accessories may be located in the patient environment if required. The colored lights are as designated by ANSI S 3.6 and IEC 60645-1, conforming to the standard color designations for audiology. They signify that either the left (blue) channel is active or the right (red) channel is active, or no channel is active (green). The colors do not signify any dangerous or faulty condition. Contact the local MedRx distributor for safe and proper disposal of this equipment. Proper disposal may require that it be sent to collection facilities for recovery and recycling. All repairs should be sent to MedRx for evaluation and / or repair. However, necessary diagrams and repair instruction will upon request be provided to authorized repair personnel. There are no known contraindications for the use of this equipment. The Instructions for Use (the Installation and Software Training manuals) are supplied as an electronic copy on a USB flash drive. Paper copies of the manuals may be also requested from the company, and will be sent within one business day of the request. Refer to the Training manual and Help files for test options and descriptions. D-0125128-C DRAFT 75 Symbols that may be used or SN Read the instruction manuals for safe usage of the device
(operating instructions) Indicates that the device serial number will follow Type B applied part.
(Type B equipment) Manufacturer
(MedRx) Authorized Representative in Europe Non-ionizing electromagnetic radiation Special Disposal Required Humidity Limitation Caution, General warning sign Temperature limitation Read the instruction manuals for safe usage of the device
(operating instructions) Class II equipment Start (of action) Stop (of action) Percentile Setup Calibration Loudspeaker (Speaker) Headphones Microphone Recording CAUTION For Single Patient Use Only Handheld microphone
(Talkback Microphone) Medical Device Label D-0125128-C DRAFT 76 Recommended Procedures for Cleaning and Disinfection 1. Foam ear tips and probe tubes are single use components, and should not be re-used by another patient. 2. It is recommended that 70% Isopropyl Alcohol should be applied to a soft clean cloth or tissue, not directly on the component to be cleaned. The cloth should never be wet, just damp. A mild soapy water solution is an alternative cleaning liquid. 3. To ensure that cross contamination does not occur, use clean cloth or sealed Alcohol swabs for each device to be cleaned. 4. Wipe the surfaces of the Operator headset and headphone pads with the 70% Isopropyl Alcohol. Clean other transducers in the same way. Do not let 70% Isopropyl Alcohol or water enter the microphone sound inlet. 5. The white device housing may also be wiped with 70% Isopropyl Alcohol. The speaker controls, headphone ear pads, head band and other components may be cleaned in a similar way. 6. Let all components that have been cleaned, thoroughly dry before use. 7. Cleaning of the computer should be performed using the methods suggested in the computers manual. D-0125128-C DRAFT 77 Permissions (Optional) MedRx Studio uses the default windows user accounts to control access to the software. The default user settings are typically sufficient for regulatory bodies. These settings can be also adjusted if needed to comply with country requirements. MedRx Studio software does not store private information. Data control is performed by the office management system or patient management system
(i.e. Noah, Blueprint, Sycle). The below Permissions information is for advanced users only needing to comply with specific country regulations. Warning, changes to the settings below will change the overall Windows user accounts, settings and encryption. Password Protection To access the Windows User settings, navigate to the Control Panel Ensure that access to the computer is limited to those with permissions to health data. Add/Remove users as appropriate. Administrators will have access to add/remove programs, users and user settings. D-0125128-C DRAFT 78 Adjusting log out time period Create user settings to lock the computer when not in use. Navigate to local security policy and adjust the Amount of idle time required before suspending session. Adjusting this setting will prevent unintended access to the computer and health records. Setting maximum password age Local Security Policy will also identify the required password expiration timeframe. Be sure to set this to local standards. D-0125128-C DRAFT 79 Technical Information The MedRx AWRC Audiometer/REM Combination is an active, diagnostic Class IIa Medical Device according to the EU Medical Device Regulation 2017/745. Standards:
IEC 60601-1: Class II IEC 60601-1-2: Class A IEC 60645-1 IEC 61669 ANSI S3.6: Type 1 HFAE ANSI 3.46 ISO 15223-1 Medical Device Regulation 2017/745 Test-Frequencies: 125 Hz 20000 Hz Level step: 5 dB or 1 dB level steps Maximum Sound Pressure Level:
AC with earphone: - 10 dBHL to 120 dBHL BC with bone conduction with B 71: - 10 dBHL to 80 dBHL Sound field speaker: - 10 dBHL ... 90 dBHL Test Signal: Pure tone, pulse tone, warble tone Masking Signals: Narrow band noise: 5/12 Octave filter with the same center frequency resolution as pure Tone White noise:
Speech Noise: falling 12 dB/octave above 1 kHz (+/-5 dB) Masking Signals: Tone Audiometry: Narrow Band Noise
(Default), Speech Weighted Noise, White Noise. Speech Audiometry: Speech Weighted Noise (Default), White Noise, External Recorded (Opposite Channel). Speech Signals: External input is through the computer (CD, memory card, Wave file) Operator Microphone Modulation:
Pulse tone: 0.25/0.5 s on time. Warble tone: 5% sinus frequency modulation, repetition rate 5 Hz Modulation:
Pulse tone: 0.25/0.5 s on time. Warble tone: 5% sinus frequency modulation, repetition rate 5 Hz Patient Response: Handheld response switch Monitor: Build in monitor speaker, headset Communication: Talk forward and talk back Data Connection: USB Mode of Operation: Continuous Warm up Time: Less than 5 min after USB connection Dimensions: W x D x H: Approx. 7.75 x 5 x 1.25 (+/- 0.125) Weight: Less than 2 lbs. Power Supply:
100 - 240 V~ 50/60 Hz 10 % producing 15 VDC USB: 5 VDC Power Consumption:
Less than 500 mA at 15 VDC / less than 500 mA at 5 VDC Connection Sockets:
Power/Communication Power Speaker left Speaker right Pat patient response switch Talk Back microphone Operator Microphone Operator Monitor headphone Left Probe microphone (X2) Right Probe microphone (X2) Bone (bone conductor) AC phone left AC phone right Patient (Client) headphone Line Level Stereo Speaker Output Specification USB: (5 VDC) 15 VDC ZA= 4, UA= 8 Veff ZA= 4 , UA= 8 Veff RI= 500 ZI= 1 k , UI= 0.38 500 mVeff ZI= 1 k , UI= 0.38 500 mVeff ZA= 32 , UA= 3 Veff ZI= 1 k , UI= 0.38 500 mVeff ZI= 1 k , UI= 0.38 500 mVeff ZA= 10, UA= 8 Veff ZA=10 , UA=1 Veff ZA=10 , UA=1 Veff ZA= 32 , UA= 3 Veff ZA= 32 , UA= 3 Veff D-0125128-C DRAFT 80 Calibration values and Max Levels:
Headphone DD45 NBS-9A acoustic coupler Force 4-5 N, ANSI and IEC DD45 RETSPL Values RETSPL dB re 20Pa Calibration values and Max Levels:
Headphone TDH39 NBS-9A acoustic coupler Force 4-5 N, ANSI and IEC RETSPL dB re 20Pa Calibration values:
Calibration values:
Calibration values:
Calibration values:
Insert phone Eartone 3A HA-2 acoustic coupler RETSPL dB re 20Pa Insert phone IP30 HA-2 acoustic coupler RETSPL dB re 20Pa Bone conductor Radioear B71 Force: 4.9
... 5.9 N Sound Attenuation Sound Attenuation Mastoid placement ANSI S3.13 coupler Sound field (0 degree incidence) Reference equivalent threshold sound pressure level RETSPL dB 125=47.5 250=27.0 500=13.0 750=6.5 1000=6.0 1500=8.0 2000=8.0 3000=8.0 4000=9.0 6000=20.5 8000=12.0 Speech=18.5 125=45.0 250=25.5 500=11.5 750=8.0 1000=7.0 1500=6.5 2000=9.0 3000=10.0 4000=9.5 6000=15.5 8000=13.0 9000=13.0 10000=13.0 11200=13.0 12500=13.0 Speech=19.5 125=26.0 250=14.0 500=5.5 750=20 1000=0 1500=2.0 2000=3.0 3000=3.5 4000=5.5 6000=2.0 8000=0 Speech=12.5 32.5 36 37.5
36.5
33
39.5
42.5 125=26.0 250=14.0 500=5.5 750=2.0 1000=0 1500=2.0 2000=3.0 3000=3.5 4000=5.5 6000=2.0 8000=0 Speech=12.5 32.5 36 37.5
36.5
33
39.5
42.5 Air Radiation mean
/maximum
4/18 RETFL dB re1 N 125=82.5 250=67.0 500=58.0 750=48.5 1000=42.5 1500=36.5 2000=31.0 3000=30.0 4000=35.5 -
6000=40.0 10.5/31 8000=40.0 Speech=55.0
125=22.1 250=11.4 500=4.4 750=2.4 1000=2.4 1500=2.4 2000=-1.3 3000=-5.8 4000=-5.4 6000=4.3 8000=12.6 Speech=14.5 D-0125128-C DRAFT 81 Maximum Sound Levels:
Frequency Inserts Supra-aural Sound Field Bone Conduction 125 250 500 750 1000 1500 2000 3000 4000 6000 8000 75 100 110 110 115 115 115 115 115 100 90 80 100 110 110 120 120 120 120 120 105 100 65 80 90 90 90 90 90 90 90 90 80 45 60 60 70 70 70 70 60 50 45 Routine checking and subjective tests The user of the instrument should perform a subjective instrument check once a week. The purpose of routine checking is to ensure, as far as possible, that the equipment is working properly, that its calibration has not noticeably altered and that its attachments, leads and accessories are free from any defect that might adversely affect the test result. Check that audiometer output is approximately correct on both air and bone conduction by sweeping through at a hearing level of, for example, 10 dB or 15 dB and listening for just audible tones. This test shall be performed at all appropriate frequencies and for both earphones as well as the bone vibrator. Check at high level (e.g. hearing levels of 60 dB on air conduction and 40 dB on bone conduction) on all appropriate functions (and on both earphones) at all frequencies used; listen for proper functioning, absence of distortion, freedom from interrupter clicks, etc. Listen at low levels for any sign of noise or hum, for unwanted sounds (break-through arising when a signal is introduced in another channel) or for any change in tone quality as masking is introduced. Keep a record the results. D-0125128-C DRAFT 82 Limited Warranty MedRx, Inc warrants this product to be free from defects in material and workmanship for one year from the time of purchase. If this system fails to perform as specified during this period, the purchaser is responsible for calling MedRx at (888) 392-1234 or (727) 584-9600. The company's representative will advise the owner to either return specific components or the entire system to:
MedRx, Inc. 1200 Starkey Road #105 Largo, FL 33771 USA MedRx will repair or replace any defective devices, fully test the system and/or components and ship the system promptly back to the owner. There is no cost for the repair or return shipping, provided the system is one year old or less and has not been misused, abused or damaged. Such damage includes, but is not limited to, dropping, exposure to excessive heat greater than 100F and water/liquid damage. Repair or replacement of the system as provided under this warranty is the sole and exclusive remedy of the purchaser. MedRx shall not be liable for any consequential or incidental damages or for breach of any express or implied warranty. Except to the extent of applicable law, any implied warranty, merchantability or fitness of this product is limited to the duration of this warranty. MedRx will, at its discretion, service and repair out of warranty products at the purchaser's request, charging for parts and labor as necessary. The limited warranty is deemed void if software or hardware is installed on this product which is not pre-approved by MedRx, Inc. Approved software includes Noah and HIMSA approved hearing aid manufacturer programming modules for fitting hearing aids. MedRx, Inc. is not responsible for problems resulting from installation of unapproved software or hardware. In the event of unapproved software or hardware installed on the system causing a conflict, MedRx will service the product for a fee to be determined at the time of service. Any extension of this warranty past the initial one-year warranty is subject to the following (where applicable). 1. A $300 deductible per repair. 2. Extended warranty does not include cables, connectors or peripherals. D-0125128-C DRAFT 83
1 | agent letter | Cover Letter(s) | 278.85 KiB | September 12 2022 |
led ER. www.medrx-diagnostics.com 1200 Starkey Rd. #105 Largo, FL 33771 U.S.A. 888-392-1234 727-584-9600 Fax: 727-584-9602 5/16/2022 Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Authority to Act as Agent FCC On our behalf, | appoint Spencer Zhong of Nemko Canada, Inc. 303 River Road, Ottawa, Ontario, Canada K1V 1H2, to act as our agent in the preparation of this application for equipment certification. | certify that submitted documents properly describe the device or system for which equipment certification is sought. | also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, |
acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides MedRx, Inc. and 1200 Starkey Rd. #105, Largo, FL 33771. Dated this 16 Day of May 20 22 Agency agreement expiration date: 16" May 2023 By: [ A LE | ) e. Caleb Sparkman ignature Printed Title: VP Telephone: +1.727.584.9600 On behalf of: MedRx, Inc. 000000 mee 111111
1 | confidential letter | Cover Letter(s) | 140.72 KiB | September 12 2022 |
www.medrx-diagnostics.com 1200 Starkey Rd. #105 Largo, FL 33771 U.S.A. 888-392-1234 727-584-9600 Fax: 727-584-9602 8/15/2022 Nemko Canada Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 FCC ID: 2A6UNMEDRXWRP Model: MedRx Wireless REM Probe Request for Permanent Confidentiality Pursuant to Sections 0.457(d) and 0.459 of the Commissions rules, we hereby request that the following documents be held confidential:
Schematics Block diagram Bill of Materials Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated: 8/15/2022 Signed:
Printed name: Caleb Sparkman Title: President On behalf of: MedRx, Inc.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-09-12 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2022-09-12
|
||||
1 | Applicant's complete, legal business name |
MedRx, Inc.
|
||||
1 | FCC Registration Number (FRN) |
0032393662
|
||||
1 | Physical Address |
1200 Starkey Road Suite 105
|
||||
1 |
Largo, FL
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
V******@nemko.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2A6UN
|
||||
1 | Equipment Product Code |
MEDRXWRP
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
C******** S******
|
||||
1 | Title |
Vice President
|
||||
1 | Telephone Number |
72758********
|
||||
1 | Fax Number |
72758********
|
||||
1 |
m******@medrx-diagnostics.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | REM probe | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is conducted. Transmit power is below the FCC SAR exemption limits for a device with a separation distance of 8.6 mm from the human body. These exemption limits are in accordance with FCC CFR 47 §2.1093. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Nemko Canada Inc. (Cambridge)
|
||||
1 | Name |
C**** N****
|
||||
1 | Telephone Number |
613-7******** Extension:
|
||||
1 |
c******@nemko.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0043000 |