all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Operator Manual V1.3 | Users Manual | 1.01 MiB | ||||
1 |
|
Operator Manual V1.4 | Users Manual | 993.81 KiB | ||||
1 |
|
Operator Manual | Users Manual | 1.04 MiB | ||||
1 |
|
Revised Operator Manual | Users Manual | 1.05 MiB | August 10 2012 | |||
1 | Operational Description | August 10 2012 | ||||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | Test Report | |||||||
1 | ID Label/Location Info | |||||||
1 | RF Exposure Info | August 10 2012 | ||||||
1 | External Photos | native | ||||||
1 | External Photos | native | ||||||
1 | External Photos | native | ||||||
1 | External Photos | native | ||||||
1 | Operational Description | |||||||
1 | Internal Photos | native | ||||||
1 | Internal Photos | native | ||||||
1 | Internal Photos | native | ||||||
1 | Attestation Statements | |||||||
1 | Cover Letter(s) | |||||||
1 | Test Report | |||||||
1 | Attestation Statements | August 10 2012 | ||||||
1 | Test Report | August 10 2012 | ||||||
1 | Test Setup Photos |
1 | Operator Manual V1.3 | Users Manual | 1.01 MiB |
MT-300 Pico Broadcaster Operator Manual MT300 Pico Broadcaster Version 1.3 OPERATOR MANUAL __ 1 MT-300 Pico Broadcaster Operator Manual Table of Contents 1. 2. PREFACE............................................................................................................................................ 3 IMPORTANT NOTICES ................................................................................................................... 3 FCC PART 15 INFORMATION TO THE USER ................................................................................................. 3 RF EXPOSURE............................................................................................................................................. 3 3. INTRODUCTION............................................................................................................................... 4 OVERVIEW ................................................................................................................................... 4 3.1 GENERAL DESCRIPTION ............................................................................................................... 5 3.2 INTELLECTUAL PROPERTY WARNING........................................................................................... 5 3.4 3.5 SYSTEM ARCHITECTURE ................................................................................................................... 5 3.6 APPLICATIONS IN DIGITAL SIGNAGE ................................................................................................. 7 3.7 LIST OF ABBREVIATIONS ................................................................................................................... 7 4. INSTALLATION ................................................................................................................................ 8 4.1 FRONT/REAR PANEL INTERFACE ....................................................................................................... 8 SETTING UP THE MT300 FOR FIRST TIME USE ................................................................................... 9 4.2 4.3 USING YOUR PICO BROADCASTER ...................................................................................................15 5. STREAMING .....................................................................................................................................16 5.1 STREAM CONTENT TO DEVICE ..............................................................................................................16 5.2 TUNE THE TV RECEIVER .....................................................................................................................18 6. TROUBLE SHOOTING ...................................................................................................................19 6.1 6.2 6.3 HARDWARE SETUP ..........................................................................................................................19 SET UP AND TEST ETHERNET CONNECTION. ....................................................................................19 TUNING THE TV RECEIVER .............................................................................................................20 Copyright 2012 by MELD Technology Inc. Information furnished in this document is believed to be accurate and reliable, but MELD assumes no responsibility for any errors that many appear in this material. __ 2 MT-300 Pico Broadcaster Operator Manual 1. Preface This document provides operator information on how to set up the MT300 (Ethernet to Broadcast) Pico Broadcaster. This device requires professional installation and the use of tools and procedures for determining location, minimum power requirements. 2. IMPORTANT NOTICES FCC Part 15 Information to the User Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the rules for TV bands devices, pursuant to part 15 of the FCC rules. These rules are designed to provide reasonable protection against harmful interference. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
(1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver.
(3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
(4) Consult the manufacturer, dealer or an experienced radio/TV technician for help. RF Exposure The radio described in this manual transmits RF energy. The concentrated energy from the antenna may pose a health hazard. All antennas used with this radio must be installed to provide a minimum separation from all persons of 40 cm (15.7 inches). The above separation distance must be maintained at all times. More information can be obtained from the FCC at the following website:
http://www.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet65/oet65.pdf
. __ 3 MT-300 Pico Broadcaster Operator Manual 3. Introduction The Meld Technology MT300 White Space radio must be professionally installed by a trained installer. The installation must be in accordance with 47 CFR Part 15 Subpart H and the instructions contained in this manual. Only the following components are approved for use with the radio. Power Supply: Stontronics 3A-401WP12 Antenna:
U Tek Technology Co. EA-79X-1 3.1 Overview MELD develops Pico Broadcast products for wirelessly distributing content to any DTV ever made for the North American market using newly opened white space frequencies and broadcast standard modulation methods. The advantages of Personal Broadcast based solutions are:
Lower cost labor for installation, modification and support Economy of scale using standard DTV receivers and components verses other specialized non-standard receivers and communication methods. MELDs Pico Broadcaster sends live full HD content wirelessly to any number of DTVs located in an unobstructed effective range of 360 feet, about the size of a football field. No cabling or infrastructure equipment investment needed. __ 4 MT-300 Pico Broadcaster Operator Manual 3.2 General Description Figure 1 - Typical Setup for Device configuration and TVWS access The MT300 is an easy to use Fixed TV bands device using a VSB modulator that is designed to provide low-power transmission of a DTV compatible signal over a limited area. It is designed to not interfere with licensed broadcast transmissions and complies with the FCC CFR 47 Part 15 subpart H rules for TV Band devices. It is designed to work with the tuner input of any Digital TV sold in North America. The MT300 is designed to accept properly formatted MPEG2 transport streams from a local PC running VLC or similar streaming software or a media server. The transmitted signal is compliant with the tuner input of a Digital TV receiver. Intellectual Property Warning 3.4 Some of the concepts described in this document are protected by appropriate patent protections or other legal means. These areas are identified in the text as being proprietary. For additional information on these subjects please contact MELD directly. The device described herein is protected by US Patent #8,063,996, other patents pending. 3.5 System Architecture __ 5 MT-300 Pico Broadcaster Operator Manual The device has two IP address:
System Control CPU (default) IP address: 192.168.1.194, Gateway IP: 192.168.1.254 This address points to a web form used for user registration and setting up the radio for FCC compliant operation including database access, and radio control for operational parameters of the system, such as preferred channels and power. Digital Modulator (default IP address) IP: 192.168.1.193 Port: 5002 This IP address is for Transport Stream content going directly to the MELD Digital Modulator for ATSC modulation. __ 6 MT-300 Pico Broadcaster Operator Manual 3.6 Applications in Digital Signage Pico Broadcast HD video distribution would enable airports, hotels, restaurants, bars, schools, hospitals, professional, industrial applications to wirelessly send high-quality video to any number of screens. Proven reliable: Used around the world; day in, day out, digital broadcast TV reliably sends perfect clear HD images and sound over large areas. Completely wireless: No messy wires run, hide or trip over. No external box need: Signal is 100% compatible with any DTV ever built. 3.7 List of abbreviations ATSC is the Government "Standard" for the Digital (RF) Broadcast Signal 8VSB is the name of the modulation standard used in ATSC Systems SMPTE 310M is the electrical interface that carries MPEG-2 transport streams to 8VSB modulators PSIP is the name of the "table" structure that defines the structure and order of the MPEG Streams in a valid broadcast stream ... per government regulations of USA __ 7 MT-300 Pico Broadcaster Operator Manual 4. Installation 4.1 Front/Rear Panel Interface Note: It is recommended the MT300 be installed and located in a secure area such as a network closet or operations center. The device must be installed in a location that provides a minimum separation from all persons and the antenna of 40 cm (15.7 inches). Please refer to the RF Exposure warning on page 3. __ 8 MT-300 Pico Broadcaster Operator Manual Setting up the MT300 for first time use 4.2 Recommended Network Setup Note: The MT300 needs internet access to be able to operate. The transmitter will not be enabled until the device successfully registers with and receives a channel list from the TV Bands database service. Use of the setup in figure 1 and configuring the router LAN IP address set to 192.168.1.254 will allow access to the White Space database for registration. Set the computers network setting in figure 1 to DHCP to acquire an address from the router. Connect the antenna provided to the RF port located on the back panel of the device.
(Use of a different antenna other than the one provided is prohibited) Plug-in the power supply adapter supplied with the MT300.
(Use of a different power supply other than the one provided is prohibited) The MT300 is shipped with the factory default network settings below and are assumed unchanged for the recommended network setup. Factory Default Network Settings Configuration Type - Static IP Address - 192.168.1.194 Subnet Mask - 255.255.0.0 Gateway Address - 192.168.1.254 Primary DNS - 192.168.1.254 Secondary DNS Streaming IP Address 192.168.1.193 Using your PC internet browser; type http://192.168.1.194 in the browser URL field to access the device webpage interface. The device registration tab will be displayed. To complete the device registration process, proceed to the Device Registration section below for registering your device. Custom Network Setup Note: Currently, the MT300 only supports network subnets that are limited to 192.168.0.0. The MT300 is shipped with the factory default network settings above. To change the default network settings to be compatible with your network addressing scheme use the __ 9 MT-300 Pico Broadcaster Operator Manual setup in figure 1 or use the alternative setup below in figure 2 to change the MT300 network configuration. If using the typical setup in figure 1, connect a PC and the MT300 to the router and set the computers IP Address to a static IP address on the same subnet as the default settings for the MT300 (e.g., 192.168.1.100). The LAN side of the router must be configured for addresses within the 192.168.0.0 subnet. Figure 2 Alternative setup for device configuration If using the alternative setup for device configuration, connect a PC to the MT300 Ethernet port and set the computers IP Address to a static IP address on the same subnet as the default settings for the MT300 (e.g., 192.168.1.100). Using your PC internet browser; type http://192.168.1.194 in the browser URL field to access the device webpage interface. The registration tab will be displayed. Select the Advanced>Network tabs to display the Network Configuration default values as shown below:
__ 10 MT-300 Pico Broadcaster Operator Manual Complete the IP setting fields on the Network tab compatible with your network addressing scheme. Click the Save & Apply button on the bottom of the page. Note: Depending on the changes made to the IP address configuration, the MT300 may no longer be reachable using the figure 1 and 2 recommended IP address configurations. Connect the MT300 to a network interface that will allow the device access to the internet. The MT300 needs internet access to be able to operate. The transmitter will not be enabled until the device successfully registers with and receives a channel list from the TV Bands database service. Using your PC internet browser; type the IP address assigned to the MT300 in the custom network setup http://192.168.x.x in the browser URL field to access the device webpage interface. The device registration tab will be displayed. To complete the device registration process, proceed to the Device Registration section below for registering your device. Device Registration - Registering your device with the White Space Database Select the White Space Registration tab and complete the White Space Registration form. All fields are required for successful registration. Click on the Save & Apply button on the bottom of the page. This will enable the FCC certified database to authenticate the system and provide white space channels that are available for use in your location. Reference the examples shown below. Note: Professional installation tools and procedures for determining location must be used to accurately determine the location within +/- 50 m accuracy. __ 11 MT-300 Pico Broadcaster Operator Manual Registration Screen NOTE: PRESS SAVE AND APPLY BEFORE GOING TO NEXT SCREEN. __ 12 MT-300 Pico Broadcaster Operator Manual Status Screen After your device communicates with the database (allow up to 1 minute) the transmitter output will be enabled. NOTE: The transmitter will not output a signal prior to being authenticated by and receiving a channel list from the White Space Registration database. __ 13 MT-300 Pico Broadcaster Operator Manual Advanced Settings Set the power level to the lowest level required by the application The FCC rules for White Space devices require that the minimum transmit power required for reception of the signal must be used. The MT300 transmit power must be adjusted to use the minimum power necessary for reception of the signal. Use the following steps to determine the minimum required transmit power:
Step 1 - Locate the TV receiver furthest from the MT300 location. Step 2 - Set the power level selection to a value of 1 by using the Power Level pull down menu. (A setting of 1 is lowest available power and a setting of 11 is the highest rated power.) Step 3 - Begin transmission as described in section 5 and adjust the power level setting by increments of 1 until a picture of the transmitted content is viewable on the digital TV. Set the preferred channels To select preferred channels from the list of available channels, fill in the Preferred Channels field with the desired channels of operation in order of preference. __ 14 MT-300 Pico Broadcaster Operator Manual Using your Pico Broadcaster 4.3 Station Identification Signal The FCC requires that Fixed TVBDs transmit identifying information sufficient to identify the device and its geographic coordinates. The MT300 ID signal is transmitted as an ATSC compliant signal that can be received by any Digital TV receiver. The following information is required in the ID message:
Transmitter Location: 34.34567 N, 119.32487 W FCC ID: OKVMT300 Manufacturer: MELD Technology Following the steps below the operator is required to stream the identification information for transmission no less than once a day. Step 1: Create a file containing the required identification identified above. Using a video editing system such as Micro Soft Movie Maker or others, create a Title Screen containing 3 lines with the following information:
Transmitter Location: 34.34567 N, 119.32487 W FCC ID: OKVMT300 Manufacturer: MELD Technology The location information above is an example only. The location will be unique for each device installation, refer to section 4.2 of this manual to obtain the registration location information for your device Step 2: Save your file as an MPEG2 standard format file Using the video editor render the Title Screen as a 3 second MPEG2 formatted file. Step 3: Stream the content to the MT300 Following the instructions in section 5.1 of this manual, stream the MPEG2 file to the MT300. Verify the information is displayed on at least one of the TV receivers tuned to the transmitting channel as shown in the example below:
__ 15 MT-300 Pico Broadcaster Operator Manual NOTE: When not streaming content to your MT300, turn off your transmitter by removing power to the device. 5. Streaming 5.1 Stream content to device If you are using a Bright Sign box youll need to refer to their manual. If you are using a PC you can use the VLC media player as an example. The application can be found here: http://www.videolan.org/vlc/index.html. If you are unfamiliar with VLC media player follow the instructions below. We are currently using VLC for streaming (www.videolan.org). This configuration has been tested using version 1.0.5 and 1.1.11. We suggest you download the latest version, its free. For more information go to www.meldtech.com/support Setting up the PC (IP address scheme assumes MT300 factory default settings) In a Command prompt window type IPCONFIG to view the PC IP address. Note: When using direct connection, make sure the PC and MT300 are in the same IP domain. Set the computers IP Address to a static address on the same subnet as the MT300 (e.g., 192.168.1.100) in a Command prompt window type ping 192.168.1.193 (This operation sets up an ARP entry on the PC) If properly working the ping command will return Request timed out message. This means the Ping command properly saw the MT300 but the MT300 did not respond back, which is to be expected as the MT300 is a one-way streamer and cannot reply. If it says not connected, check physical connection and power MT300. Make sure ARP table registry is correct In a Command prompt window type type Arp a __ 16 MT-300 Pico Broadcaster Operator Manual You should see the device Internet Address: 192.168.1.193 If using VLC GUI Streamer Configuration Set to RTP streaming mode Address:
Port:
192.168.1.193 5002 Using VLC Streamer Command line Easy streaming If you find the navigating the VLC GUI a little tedious we suggest we set up some batch files. (Some examples are provided below.) You could also use VLC with a command line interface via Command prompt window for streaming; it is easier than the GUI interface. Creating a batch file is a good way to easily and simply broadcast demo content. Of course file locations and stream names may change depending on your computer configuration. Sample Batch files Streaming an DVD What you are doing: Sending DVD stream to 192.168.1.193, port=5002
*** Sample Batch file 1: Broadcasts a DVD ***
Note: It is very easy and convenient to stream DVDs using VLC. (DVDs are a great source for TS material). We suggest you start with this Using notepad editor to create BroadcastDVD.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe" dvdsimple://D:\
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 Streaming an MPEG2 file What you are doing: Sending an MPEG2 transport stream to 192.168.1.193, port=5002 How to do it: Creating a batch file is a good way to easily and simply broadcast demo content.
*** Sample Batch file 2: Broadcast a few HD files in a loop ***
NOTE! The file MUST be MPEG2 format. __ 17 MT-300 Pico Broadcaster Operator Manual BroadcastHD.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe"
"C:\Control\worktestvideo\Shuttle.trp" loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 "C:\Control\worktestvideo\Clip4.trp" --loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 "C:\Control\worktestvideo\Thunderbirds 480I.mpg" --loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 Streaming your PC screen What you are doing: Sending your PC screen to 192.168.1.193, port=5002
*** Sample Batch file 3: Broadcasts whats on your PC screen. ***
Note: First set your screen resolution to 1480x720p Screencast.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe" screen://
:sout=#transcode{vcodec=mp2v,vb=2000,scale=1}:rtp{dst=192.168.1.193,port=5002,mu x=ts} :no-sout-rtp-sap :no-sout-standard-sap :ttl=1 5.2 Tune the TV Receiver Select antenna in on your TV. Make sure you have an antenna attached. Using the keypad, type in the preferred channel selected during the device setup. Example: 23.1. If the TV does not allow you to directly type in a channel, execute a channel scan and then type your preferred channel. Example 23.1 __ 18 MT-300 Pico Broadcaster Operator Manual 6. Trouble Shooting Hardware Setup 6.1 If the MT300 is not transmitting the supplied content, the device may be unable to contact the database or the media server may not be configured correctly. You must connect the MT300 to an internet accessible network in order to access the internet for database services. The media providing streaming content to the MT300 must be configured correctly and the TV tuner must be tuned to the correct channel to receive the transmitted content. Refer to the following steps:
Set up and test Ethernet connection. 6.2 If the power LED is not illuminated on the MT300 front panel:
Verify the power connection is securely plug in on the back panel Verify the A/C power outlet that power supply is plugged into. Check the static address setting on the PC or media delivering the content. In a Command prompt window type IPCONFIG to view the PC IP address. Note: When using direct connection, make sure the PC and MT300 are in the same IP domain: Set the computers IP Address to a static address on the same subnet as the MT300 (e.g., 192.168.1.100) If the transmit or On Air light is not illuminated on the front panel, verify the MT300 network connection to the TVWS database service. Connect a PC to the same local network connection that the MT300 is using Verify a successful reply from the TVWS service:
In a Command prompt window Type ping tvws.spectrumbridge.com ping tvws.spectrumbridge.com Pinging tvws.spectrumbridge.com [204.51.99.33] with 32 bytes of data:
Reply from 204.51.99.33: bytes=32 time=27ms TTL=242 __ 19 MT-300 Pico Broadcaster Operator Manual If the ping reply message times out without a reply, investigate potential network or internet problems. Check Ethernet connection to the MT300 in a Command prompt window type ping 192.168.1.193 If properly working the ping command will return Request timed out as shown in Fig 1.0. This means the Ping command properly saw the MT300 but the MT300 did not respond back, which is to be expected as the MT300 is a one-way streamer and can not reply. If it says not connected, check physical connection and power MT300. Make sure ARP table registry is correct In a Command prompt window type Arp a You should see the device Internet Address: 192.168.1.193 Note: If you do NOT see the device youll need to force the ARP table to map to the IP address to the physical address of the MT300 (i.e. 00 02 03 04 05 06.) Use the second mac addess printed on the label which is located on the bottom of the MT300 case. ARP command to set ARP TABLE in a Command prompt window type arp -s 192.168.1.193 00-02-03-04-05-06 Tuning the TV Receiver 6.3 If you are confident that you have correctly set up the media server and the transmit light on the MT300 is illuminated you may need to repeat the channel scan on you TV receiver. Select antenna in on your TV. Make sure you have an antenna attached. Using the keypad, type in the preferred channel selected during the device setup. Example: 23.1. If the TV does not allow you to directly type in a channel, execute a channel scan and then type your preferred channel. Example 23.1 __ 20
1 | Operator Manual V1.4 | Users Manual | 993.81 KiB |
MT-300 Pico Broadcaster Operator Manual MT300 Pico Broadcaster Version 1.4 OPERATOR MANUAL __ 1 MT-300 Pico Broadcaster Operator Manual Table of Contents 1. 2. PREFACE............................................................................................................................................ 3 IMPORTANT NOTICES ................................................................................................................... 3 FCC PART 15 INFORMATION TO THE USER ................................................................................................. 3 RF EXPOSURE............................................................................................................................................. 3 3. INTRODUCTION............................................................................................................................... 4 OVERVIEW ................................................................................................................................... 4 3.1 GENERAL DESCRIPTION ............................................................................................................... 5 3.2 INTELLECTUAL PROPERTY WARNING........................................................................................... 5 3.4 3.5 SYSTEM ARCHITECTURE ................................................................................................................... 6 3.6 APPLICATIONS IN DIGITAL SIGNAGE ................................................................................................. 7 3.7 LIST OF ABBREVIATIONS ................................................................................................................... 7 4. INSTALLATION ................................................................................................................................ 8 4.1 FRONT/REAR PANEL INTERFACE ....................................................................................................... 8 SETTING UP THE MT300 FOR FIRST TIME USE ................................................................................... 9 4.2 4.3 USING YOUR PICO BROADCASTER ...................................................................................................15 5. STREAMING .....................................................................................................................................16 5.1 STREAM CONTENT TO DEVICE ..............................................................................................................16 5.2 TUNE THE TV RECEIVER .....................................................................................................................18 6. TROUBLE SHOOTING ...................................................................................................................19 6.1 6.2 6.3 HARDWARE SETUP ..........................................................................................................................19 SET UP AND TEST ETHERNET CONNECTION. ....................................................................................19 TUNING THE TV RECEIVER .............................................................................................................20 Copyright 2012 by MELD Technology Inc. Information furnished in this document is believed to be accurate and reliable, but MELD assumes no responsibility for any errors that many appear in this material. __ 2 MT-300 Pico Broadcaster Operator Manual 1. Preface This document provides operator information on how to set up the MT300 (Ethernet to Broadcast) Pico Broadcaster. This device requires professional installation and the use of tools and procedures for determining location, minimum power requirements. 2. IMPORTANT NOTICES FCC Part 15 Information to the User Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the rules for TV bands devices, pursuant to part 15 of the FCC rules. These rules are designed to provide reasonable protection against harmful interference. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
(1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver.
(3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
(4) Consult the manufacturer, dealer or an experienced radio/TV technician for help. RF Exposure The radio described in this manual transmits RF energy. The concentrated energy from the antenna may pose a health hazard. All antennas used with this radio must be installed to provide a minimum separation from all persons of 40 cm (15.7 inches). The above separation distance must be maintained at all times. More information can be obtained from the FCC at the following website:
http://www.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet65/oet65.pdf
. __ 3 MT-300 Pico Broadcaster Operator Manual 3. Introduction The Meld Technology MT300 White Space radio must be professionally installed by a trained installer. The installation must be in accordance with 47 CFR Part 15 Subpart H and the instructions contained in this manual. Only the following components are approved for use with the radio. Power Supply: Stontronics 3A-401WP12 Antenna:
U Tek Technology Co. EA-79X-1 3.1 Overview MELD develops Pico Broadcast products for wirelessly distributing content to any DTV ever made for the North American market using newly opened white space frequencies and broadcast standard modulation methods. The advantages of Personal Broadcast based solutions are:
Lower cost labor for installation, modification and support Economy of scale using standard DTV receivers and components verses other specialized non-standard receivers and communication methods. MELDs Pico Broadcaster sends live full HD content wirelessly to any number of DTVs located in an unobstructed effective range of 360 feet, about the size of a football field. No cabling or infrastructure equipment investment needed. __ 4 MT-300 Pico Broadcaster Operator Manual 3.2 General Description Figure 1 - Typical Setup for Device configuration and TVWS access The MT300 is an easy to use Fixed TV bands device using a VSB modulator that is designed to provide low-power transmission of a DTV compatible signal over a limited area. It is designed to not interfere with licensed broadcast transmissions and complies with the FCC CFR 47 Part 15 subpart H rules for TV Band devices. It is designed to work with the tuner input of any Digital TV sold in North America. The MT300 is designed to accept properly formatted MPEG2 transport streams from a local PC running VLC or similar streaming software or a media server. The transmitted signal is compliant with the tuner input of a Digital TV receiver. Intellectual Property Warning 3.4 Some of the concepts described in this document are protected by appropriate patent protections or other legal means. These areas are identified in the text as being proprietary. For additional information on these subjects please contact MELD directly. The device described herein is protected by US Patent #8,063,996, other patents pending. __ 5 MT-300 Pico Broadcaster Operator Manual 3.5 System Architecture The device has two IP address:
System Control CPU (default) IP address: 192.168.1.194, Gateway IP: 192.168.1.254 This address points to a web form used for user registration and setting up the radio for FCC compliant operation including database access, and radio control for operational parameters of the system, such as preferred channels and power. Digital Modulator (default IP address) IP: 192.168.1.193 Port: 5002 This IP address is for Transport Stream content going directly to the MELD Digital Modulator for ATSC modulation. __ 6 MT-300 Pico Broadcaster Operator Manual 3.6 Applications in Digital Signage Pico Broadcast HD video distribution would enable airports, hotels, restaurants, bars, schools, hospitals, professional, industrial applications to wirelessly send high-quality video to any number of screens. Proven reliable: Used around the world; day in, day out, digital broadcast TV reliably sends perfect clear HD images and sound over large areas. Completely wireless: No messy wires run, hide or trip over. No external box need: Signal is 100% compatible with any DTV ever built. 3.7 List of abbreviations ATSC is the Government "Standard" for the Digital (RF) Broadcast Signal 8VSB is the name of the modulation standard used in ATSC Systems SMPTE 310M is the electrical interface that carries MPEG-2 transport streams to 8VSB modulators PSIP is the name of the "table" structure that defines the structure and order of the MPEG Streams in a valid broadcast stream ... per government regulations of USA __ 7 MT-300 Pico Broadcaster Operator Manual 4. Installation 4.1 Front/Rear Panel Interface Note: It is recommended the MT300 be installed and located in a secure area such as a network closet or operations center. The device must be installed in a location that provides a minimum separation from all persons and the antenna of 40 cm (15.7 inches). Please refer to the RF Exposure warning on page 3. __ 8 MT-300 Pico Broadcaster Operator Manual Setting up the MT300 for first time use 4.2 Recommended Network Setup Note: The MT300 needs internet access to be able to operate. The transmitter will not be enabled until the device successfully registers with and receives a channel list from the TV Bands database service. Use of the setup in Figure 1 and configuring the router LAN IP address set to 192.168.1.254 will allow access to the White Space database for registration. Set the computers network setting in Figure 1 to DHCP to acquire an address from the router. Connect the antenna provided to the RF port located on the back panel of the device.
(Use of a different antenna other than the one provided is prohibited) Plug-in the power supply adapter supplied with the MT300.
(Use of a different power supply other than the one provided is prohibited) The MT300 is shipped with the factory default network settings below and are assumed unchanged for the recommended network setup. Factory Default Network Settings Configuration Type - Static IP Address - 192.168.1.194 Subnet Mask - 255.255.0.0 Gateway Address - 192.168.1.254 Primary DNS - 192.168.1.254 Secondary DNS Streaming IP Address 192.168.1.193 Using your PC internet browser; type http://192.168.1.194 in the browser URL field to access the device webpage interface. The device registration tab will be displayed. To complete the device registration process, proceed to the Device Registration section below for registering your device. Custom Network Setup Note: Currently, the MT300 only supports network subnets that are limited to 192.168.0.0. The MT300 is shipped with the factory default network settings above. To change the default network settings to be compatible with your network addressing scheme use the __ 9 MT-300 Pico Broadcaster Operator Manual setup in Figure 1 or use the alternative setup below in Figure 2 to change the MT300 network configuration. If using the typical setup in Figure 1, connect a PC and the MT300 to the router and set the computers IP Address to a static IP address on the same subnet as the default settings for the MT300 (e.g., 192.168.1.100). The LAN side of the router must be configured for addresses within the 192.168.0.0 subnet. Figure 2 Alternative setup for device configuration If using the alternative setup for device configuration in Figure 2, connect a PC to the MT300 Ethernet port and set the computers IP Address to a static IP address on the same subnet as the default settings for the MT300 (e.g., 192.168.1.100). Using your PC internet browser; type http://192.168.1.194 in the browser URL field to access the device webpage interface. The registration tab will be displayed. Select the Advanced>Network tabs to display the Network Configuration default values as shown below:
__ 10 MT-300 Pico Broadcaster Operator Manual Complete the IP setting fields on the Network tab compatible with your network addressing scheme. Click the Save & Apply button on the bottom of the page. Note: Depending on the changes made to the IP address configuration, the MT300 may no longer be reachable using the figure 1 and 2 recommended IP address configurations. Connect the MT300 to a network interface that will allow the device access to the internet. The MT300 needs internet access to be able to operate. The transmitter will not be enabled until the device successfully registers with and receives a channel list from the TV Bands database service. Using your PC internet browser; type the IP address assigned to the MT300 in the custom network setup http://192.168.x.x in the browser URL field to access the device webpage interface. The device registration tab will be displayed. To complete the device registration process, proceed to the Device Registration section below for registering your device. Device Registration - Registering your device with the White Space Database Select the White Space Registration tab and complete the White Space Registration form. All fields are required for successful registration. Click on the Save & Apply button on the bottom of the page. This will enable the FCC certified database to authenticate the system and provide white space channels that are available for use in your location. Reference the examples shown below. Note: Professional installation tools and procedures for determining location must be used to accurately determine the location within +/- 50 m accuracy. Additionally, professional tools and procedures must be used to determine the antenna height. The antenna height input field is expressed in meters AGL. __ 11 MT-300 Pico Broadcaster Operator Manual Registration Screen NOTE: PRESS SAVE AND APPLY BEFORE GOING TO NEXT SCREEN. __ 12 MT-300 Pico Broadcaster Operator Manual Status Screen After your device communicates with the database (allow up to 1 minute) the transmitter output will be enabled. NOTE: The transmitter will not output a signal prior to being authenticated by and receiving a channel list from the White Space Registration database. __ 13 MT-300 Pico Broadcaster Operator Manual Advanced Settings Set the power level to the lowest level required by the application The FCC rules for White Space devices require that the minimum transmit power required for reception of the signal must be used. The MT300 transmit power must be adjusted to use the minimum power necessary for reception of the signal. Use the following steps to determine the minimum required transmit power:
Step 1 - Locate the TV receiver furthest from the MT300 location. Step 2 - Set the power level selection to a value of 1 by using the Power Level pull down menu. (A setting of 1 is lowest available power and a setting of 11 is the highest rated power.) Step 3 - Begin transmission as described in section 5 and adjust the power level setting by increments of 1 until a picture of the transmitted content is viewable on the digital TV. Set the preferred channels To select preferred channels from the list of available channels, fill in the Preferred Channels field with the desired channels of operation in order of preference. __ 14 MT-300 Pico Broadcaster Operator Manual Using your Pico Broadcaster 4.3 Station Identification Signal The FCC requires that Fixed TVBDs transmit identifying information sufficient to identify the device and its geographic coordinates. The MT300 ID signal is transmitted as an ATSC compliant signal that can be received by any Digital TV receiver. The following information is required in the ID message:
Transmitter Location: 34.34567 N, 119.32487 W FCC ID: OKVMT300 Manufacturer: MELD Technology Following the steps below the operator is required to stream the identification information for transmission no less than once a day. Step 1: Create a file containing the required identification identified above. Using a video editing system such as Micro Soft Movie Maker or others, create a Title Screen containing 3 lines with the following information:
Transmitter Location: 34.34567 N, 119.32487 W FCC ID: OKVMT300 Manufacturer: MELD Technology The location information above is an example only. The location will be unique for each device installation, refer to section 4.2 of this manual to obtain the registration location information for your device Step 2: Save your file as an MPEG2 standard format file Using the video editor render the Title Screen as a 3 second MPEG2 formatted file. Step 3: Stream the content to the MT300 Following the instructions in section 5.1 of this manual, stream the MPEG2 file to the MT300. Verify the information is displayed on at least one of the TV receivers tuned to the transmitting channel as shown in the example below:
__ 15 MT-300 Pico Broadcaster Operator Manual NOTE: When not streaming content to your MT300, turn off your transmitter by removing power to the device. 5. Streaming 5.1 Stream content to device If you are using a Bright Sign box youll need to refer to their manual. If you are using a PC you can use the VLC media player as an example. The application can be found here: http://www.videolan.org/vlc/index.html. If you are unfamiliar with VLC media player follow the instructions below. We are currently using VLC for streaming (www.videolan.org). This configuration has been tested using version 1.0.5 and 1.1.11. We suggest you download the latest version, its free. For more information go to www.meldtech.com/support Setting up the PC (IP address scheme assumes MT300 factory default settings) In a Command prompt window type IPCONFIG to view the PC IP address. Note: When using direct connection, make sure the PC and MT300 are in the same IP domain. Set the computers IP Address to a static address on the same subnet as the MT300 (e.g., 192.168.1.100) in a Command prompt window type ping 192.168.1.193 (This operation sets up an ARP entry on the PC) If properly working the ping command will return Request timed out message. This means the Ping command properly saw the MT300 but the MT300 did not respond back, which is to be expected as the MT300 is a one-way streamer and cannot reply. If it says not connected, check physical connection and power MT300. Make sure ARP table registry is correct In a Command prompt window type type Arp a __ 16 MT-300 Pico Broadcaster Operator Manual You should see the device Internet Address: 192.168.1.193 If using VLC GUI Streamer Configuration Set to RTP streaming mode Address:
Port:
192.168.1.193 5002 Using VLC Streamer Command line Easy streaming If you find the navigating the VLC GUI a little tedious we suggest we set up some batch files. (Some examples are provided below.) You could also use VLC with a command line interface via Command prompt window for streaming; it is easier than the GUI interface. Creating a batch file is a good way to easily and simply broadcast demo content. Of course file locations and stream names may change depending on your computer configuration. Sample Batch files Streaming an DVD What you are doing: Sending DVD stream to 192.168.1.193, port=5002
*** Sample Batch file 1: Broadcasts a DVD ***
Note: It is very easy and convenient to stream DVDs using VLC. (DVDs are a great source for TS material). We suggest you start with this Using notepad editor to create BroadcastDVD.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe" dvdsimple://D:\
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 Streaming an MPEG2 file What you are doing: Sending an MPEG2 transport stream to 192.168.1.193, port=5002 How to do it: Creating a batch file is a good way to easily and simply broadcast demo content.
*** Sample Batch file 2: Broadcast a few HD files in a loop ***
NOTE! The file MUST be MPEG2 format. __ 17 MT-300 Pico Broadcaster Operator Manual BroadcastHD.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe"
"C:\Control\worktestvideo\Shuttle.trp" loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 "C:\Control\worktestvideo\Clip4.trp" --loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 "C:\Control\worktestvideo\Thunderbirds 480I.mpg" --loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 Streaming your PC screen What you are doing: Sending your PC screen to 192.168.1.193, port=5002
*** Sample Batch file 3: Broadcasts whats on your PC screen. ***
Note: First set your screen resolution to 1480x720p Screencast.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe" screen://
:sout=#transcode{vcodec=mp2v,vb=2000,scale=1}:rtp{dst=192.168.1.193,port=5002,mu x=ts} :no-sout-rtp-sap :no-sout-standard-sap :ttl=1 5.2 Tune the TV Receiver Select antenna in on your TV. Make sure you have an antenna attached. Using the keypad, type in the preferred channel selected during the device setup. Example: 23.1. If the TV does not allow you to directly type in a channel, execute a channel scan and then type your preferred channel. Example 23.1 __ 18 MT-300 Pico Broadcaster Operator Manual 6. Trouble Shooting Hardware Setup 6.1 If the MT300 is not transmitting the supplied content, the device may be unable to contact the database or the media server may not be configured correctly. You must connect the MT300 to an internet accessible network in order to access the internet for database services. The media providing streaming content to the MT300 must be configured correctly and the TV tuner must be tuned to the correct channel to receive the transmitted content. Refer to the following steps:
Set up and test Ethernet connection. 6.2 If the power LED is not illuminated on the MT300 front panel:
Verify the power connection is securely plug in on the back panel Verify the A/C power outlet that power supply is plugged into. Check the static address setting on the PC or media delivering the content. In a Command prompt window type IPCONFIG to view the PC IP address. Note: When using direct connection, make sure the PC and MT300 are in the same IP domain: Set the computers IP Address to a static address on the same subnet as the MT300 (e.g., 192.168.1.100) If the transmit or On Air light is not illuminated on the front panel, verify the MT300 network connection to the TVWS database service. Connect a PC to the same local network connection that the MT300 is using Verify a successful reply from the TVWS service:
In a Command prompt window Type ping tvws.spectrumbridge.com ping tvws.spectrumbridge.com Pinging tvws.spectrumbridge.com [204.51.99.33] with 32 bytes of data:
Reply from 204.51.99.33: bytes=32 time=27ms TTL=242 __ 19 MT-300 Pico Broadcaster Operator Manual If the ping reply message times out without a reply, investigate potential network or internet problems. Check Ethernet connection to the MT300 in a Command prompt window type ping 192.168.1.193 If properly working the ping command will return Request timed out as shown in Fig 1.0. This means the Ping command properly saw the MT300 but the MT300 did not respond back, which is to be expected as the MT300 is a one-way streamer and can not reply. If it says not connected, check physical connection and power MT300. Make sure ARP table registry is correct In a Command prompt window type Arp a You should see the device Internet Address: 192.168.1.193 Note: If you do NOT see the device youll need to force the ARP table to map to the IP address to the physical address of the MT300 (i.e. 00 02 03 04 05 06.) Use the second mac addess printed on the label which is located on the bottom of the MT300 case. ARP command to set ARP TABLE in a Command prompt window type arp -s 192.168.1.193 00-02-03-04-05-06 Tuning the TV Receiver 6.3 If you are confident that you have correctly set up the media server and the transmit light on the MT300 is illuminated you may need to repeat the channel scan on you TV receiver. Select antenna in on your TV. Make sure you have an antenna attached. Using the keypad, type in the preferred channel selected during the device setup. Example: 23.1. If the TV does not allow you to directly type in a channel, execute a channel scan and then type your preferred channel. Example 23.1 __ 20
1 | Operator Manual | Users Manual | 1.04 MiB |
MT-300 Pico Broadcaster Operator Manual MT300 Pico Broadcaster Version 1.0 OPERATOR MANUAL __ 1 MT-300 Pico Broadcaster Operator Manual August 21, 2012 Table of Contents 1. 2. 3. PREFACE............................................................................................................................................ 3 IMPORTANT NOTICE ..................................................................................................................... 3 INTRODUCTION............................................................................................................................... 3 OVERVIEW ................................................................................................................................... 3 3.1 DEFAULT SETTINGS...................................................................................................................... 4 3.2 GENERAL DESCRIPTION ............................................................................................................... 4 3.3 3.4 INTELLECTUAL PROPERTY WARNING........................................................................................... 5 3.5 SYSTEM ARCHITECTURE ................................................................................................................... 5 3.6 APPLICATIONS IN DIGITAL SIGNAGE ................................................................................................. 6 3.7 LIST OF ABBREVIATIONS ................................................................................................................... 6 4. INSTALLATION ................................................................................................................................ 7 4.1 FRONT/REAR PANEL INTERFACE ....................................................................................................... 7 SETTING UP MT300 FOR FIRST TIME USE .......................................................................................... 7 4.2 4.3 USING YOUR PICO BROADCASTER ...................................................................................................12 5. TROUBLE SHOOTING ..................................................................................................................14 5.1 5.2 5.3 HARDWARE SETUP ..........................................................................................................................14 SET UP AND TEST ETHERNET CONNECTION. ....................................................................................14 STREAM CONTENT TO DEVICE .....................................................................................................15 Copyright 2012 by MELD Technology Inc. Information furnished in this document is believed to be accurate and reliable, but MELD assumes no responsibility for any errors that many appear in this material. __ 2 MT-300 Pico Broadcaster Operator Manual 1. Preface This document provides operator information on how to set up the MT300 (Ethernet to Broadcast) Pico Broadcaster. This device requires professional installation. 2. IMPORTANT NOTICE This equipment has been tested and found to comply with the rules for TV bands devices, pursuant to part 15 of the FCC rules. These rules are designed to provide reasonable protection against harmful interference. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
(1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver.
(3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
(4) Consult the manufacturer, dealer or an experienced radio/TV technician for help. 3. Introduction The Meld Technology MT300 White Space radio must be professionally installed by an trained installer. The installation must be in accordance with 47 CFR Part 15 Subpart H and the instructions contained in this manual. Only the following components are approved for use with the radio. Power Supply: Stontronics 3A-401WP12 Antenna:
U Tek Technology Co. EA-79X-1 3.1 Overview MELD develops Pico Broadcast products for wirelessly distributing content to any DTV ever made for the North American market using newly opened white space frequencies and broadcast standard modulation methods. The advantages of Personal Broadcast based solutions are:
Lower cost labor for installation, modification and support __ 3 MT-300 Pico Broadcaster Operator Manual Economy of scale using standard DTV receivers and components verses other specialized non-standard receivers and communication methods. MELDs Pico Broadcaster sends live full HD content wirelessly to any number of DTVs located in an unobstructed effective range of 360 feet, about the size of a football field. No cabling or infrastructure equipment investment needed. 3.2 Default Settings. The device has two IP address. 1) System Control CPU (default) IP address: 192.168.1.194 Gateway IP: 192.168.1.254 2) Digital Modulator (default IP address) 3) Power levels:
Output Power:
IP address: 192.168.1.193 Port: 5002 11 is the highest rated power 01 is the lowest available power 3.3 General Description __ 4 MT-300 Pico Broadcaster Operator Manual Figure 1 - Typical Setup for Device configuration and TVWS access The MT300 is an easy to use Fixed TV bands device using a VSB modulator that is designed to provide low-power transmission of a DTV compatible signal over a limited area. It is designed to not interfere with licensed broadcast transmissions and complies with the FCC CFR 47 Part 15 subpart H rules for TV Band devices. It is designed to work with the tuner input of any Digital TV sold in North America. The MT300 is designed to accept properly formatted MPEG2 transport streams from a local PC running VLC or similar streaming software or a media server. The transmitted signal is compliant with the tuner input of a Digital TV receiver. 3.4 Intellectual Property Warning Some of the concepts described in this document are protected by appropriate patent protections or other legal means. These areas are identified in the text as being proprietary. For additional information on these subjects please contact MELD directly. The device described herein is protected by US Patent #8,063,996, other patents pending. 3.5 System Architecture __ 5 MT-300 Pico Broadcaster Operator Manual The device has two IP address:
System Control CPU (default) IP address: 192.168.1.194, Gateway IP: 192.168.1.254 This address points to a web form used for user registration and setting up the radio for FCC compliant operation including database access, and radio control for operational parameters of the system, such as preferred channels and power. Digital Modulator (default IP address) IP: 192.168.1.193 Port: 5002 This IP address is for Transport Stream content going directly to the MELD Digital Modulator for ATSC modulation. 3.6 Applications in Digital Signage Pico Broadcast HD video distribution would enable airports, hotels, restaurants, bars, schools, hospitals, professional, industrial applications to wirelessly send high-quality video to any number of screens. Proven reliable: Used around the world; day in, day out, digital broadcast TV reliably sends perfect clear HD images and sound over large areas. Completely wireless: No messy wires run, hide or trip over. No external box need: Signal is 100% compatible with any DTV ever built. 3.7 List of abbreviations ATSC is the Government "Standard" for the Digital (RF) Broadcast Signal 8VSB is the name of the modulation standard used in ATSC Systems SMPTE 310M is the electrical interface that carries MPEG-2 transport streams to 8VSB modulators PSIP is the name of the "table" structure that defines the structure and order of the MPEG Streams in a valid broadcast stream ... per government regulations of USA __ 6 MT-300 Pico Broadcaster Operator Manual 4. Installation 4.1 Front/Rear Panel Interface It is recommended the MT300 be installed and located in a secure area such as a network closet or operations center. The antenna may be mounted remotely in cases where such locations do not result in the desired area of RF coverage. Setting up MT300 for first time use 4.2 To configure the device for the first time:
Connect a PC to the MT300 Ethernet port and set the computers IP Address to a static IP address on the same subnet as the MT300 (e.g., 192.168.1.100). This can be done as a direct connection or via a router, please reference figure 1 and figure 2. Note: The MT300 needs internet access to be able to operate. The transmitter will not be enabled until the device successfully registers with and receives a channel list from the TV Bands database service. __ 7 MT-300 Pico Broadcaster Operator Manual Figure 2 Alternative setup for device configuration Connect the antenna provided to the RF port located on the backside of the device.
(Use of a different antenna other than the one provided is prohibited) Plug-in the power supply adapter supplied with the MT300.
(Use of a different power supply other than the one provided is prohibited) Set up With your browser to go: http://192.168.1.194/ and complete the device registration form. All fields are required for successful registration. This will enable the FCC certified database to authenticate the system and provide white space channels that are available for use in your location. Reference the examples shown below. Professional installation tools and procedures for determining location must be used to accurately determine the location within +/- 50 m accuracy. __ 8 MT-300 Pico Broadcaster Operator Manual Registration Screen NOTE: PRESS SAVE AND APPLY BEFORE GOING TO NEXT SCREEN. __ 9 MT-300 Pico Broadcaster Operator Manual Status Screen. After your device communicates with the database (allow up to 1 minute) the transmitter output will be enabled. NOTE: The transmitter will not output any signal prior to be authenticated by the White Space Registration database. __ 10 MT-300 Pico Broadcaster Operator Manual Advanced Settings Set power level and the preferred channels youd like to use. To adjust the power use the Power Level pull down menu to select the lowest setting required to successfully transmit to the area of interest. A setting of 11 is the maximum rated power and a setting of 1 is the lowest available power. To select preferred channels from the list of available channels, fill in the Preferred Channels field with the desired channels of operation. __ 11 MT-300 Pico Broadcaster Operator Manual Using your Pico Broadcaster 4.3 Station Identification Signal The FCC requires that Fixed TVBDs transmit identifying information sufficient to identify the device and its geographic coordinates. The MT300 ID signal is transmitted as an ATSC compliant signal that can be received by any Digital TV receiver. The following information is required in the ID message:
Transmitter Location: 34.34567 N, 119.32487 W FCC ID: OKVMT300 Manufacturer: MELD Technology Following the steps below the operator is required to stream the identification information for transmission no less than once a day. Step 1: Create a file containing the required identification identified above. Using a video editing system such as Micro Soft Movie Maker or others, create a Title Screen containing 3 lines with the following information:
Transmitter Location: 34.34567 N, 119.32487 W FCC ID: OKVMT300 Manufacturer: MELD Technology The location information above is an example only. The location will be unique for each device installation, refer to section 4.2 of this manual to obtain the registration location information for your device Step 2: Save your file as an MPEG2 standard format file Using the video editor render the Title Screen as a 3 second MPEG2 formatted file. Step 3: Stream the content to the MT300 Following the instructions in section 5.3 of this manual, stream the MPEG2 file to the MT300. Verify the information is displayed on at least one of the TV receivers tuned to the transmitting channel as shown in the example below:
__ 12 MT-300 Pico Broadcaster Operator Manual Stream it If you are using a BrightSign box youll need to refer to their manual. If you are using a PC you can use the VLC media player as an example. The application can be found here: http://www.videolan.org/vlc/index.html. If you are unfamiliar with VLC media player follow the instructions below and in section 5.3 of this manual. What you are doing: Sending an MPEG2 transport stream to 192.168.1.193, port=5002 How to do it: Creating a batch file is a good way to easily and simply broadcast demo content.
*** Sample Batch file 1: Broadcasts a DVD ***
Note: It is very easy and convenient to stream DVDs using VLC. (DVDs are a great source for TS material). We suggest you start with this Using notepad editor to create BroadcastDVD.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe" dvdsimple://D:\
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 Of course file locations and stream names may change depending on your computer configuration. For more information go to www.meldtech.com/support NOTE: When not streaming content to your MT300, turn off your transmitter by removing power to the device. Tune It __ 13 MT-300 Pico Broadcaster Operator Manual TV receiver: Select antenna in on your TV. Make sure you have an antenna attached. Go to channel 23.1. If the TV does not allow you to directly type in a channel, do a channel scan and then type 23.1. 5. Trouble Shooting Hardware Setup 5.1 If the MT300 is not transmitting the supplied content, the device may be unable to contact the database or the media server may not be configured correctly. You must connect the MT300 to an internet accessible network in order to access the internet for database services. The media providing streaming content to the MT300 must be configured correctly. Refer to the following steps:
Set up and test Ethernet connection. 5.2 If the power LED is not illuminated on the MT300 front panel:
Verify the power connection is securely plug in on the back panel Verify the A/C power outlet that power supply is plugged into. Check the static address setting on the PC or media delivering the content. In a DOS window type IPCONFIG to view the PC IP address. Note: When using direct connection, make sure the PC and MT300 are in the same IP domain: Set the computers IP Address to a static address on the same subnet as the MT300 (e.g., 192.168.1.100) If the transmit or On Air light is not illuminated on the front panel, verify the MT300 network connection to the TVWS database service. __ 14 MT-300 Pico Broadcaster Operator Manual Connect a PC to the same local network connection that the MT300 is using Verify a successful reply from the TVWS service:
In a DOS window Type ping www.tvws.spectrumbridge.com ping tvws.spectrumbridge.com Pinging tvws.spectrumbridge.com [204.51.99.33] with 32 bytes of data:
Reply from 204.51.99.33: bytes=32 time=27ms TTL=242 Check Ethernet connection to the MT300 in a DOS window type ping 192.168.1.193 If properly working the ping command will return Request timed out as shown in Fig 1.0. This means the Ping command properly saw the MT300 but the MT300 did not respond back, which is to be expected as the MT300 is a one-way streamer and can not reply. If it says not connected, check physical connection and power MT300. Make sure ARP table registry is correct 2.1) in a DOS window type type Arp a You should see the device Internet Address: 192.168.1.193 Physical Address: some value Note: If for you do NOT see the device youll need to force the ARP table to map to the IP address to the physical address of the MT300 (i.e. 00 02 03 04 05 06.) ARP command to set ARP TABLE in a DOS window type arp -s 192.168.1.193 00-02-03-04-05-06 5.3 Stream content to device We are currently using VLC for streaming (www.videolan.org). This configuration has been tested using version 1.0.5 and 1.1.11. We suggest you download the latest version, its free . VLC Streamer Command line. Easy streaming If you find the navigating the VLC GUI a little tedious we suggest we set up some batch files. (So examples are provided below.) You could also use VLC with a command line interface via DOS window for streaming, it is easier than the GUI interface, Sample Command line code;
Sample Batch files. Creating a batch file is a good way to easily and simply broadcast demo content. __ 15 MT-300 Pico Broadcaster Operator Manual Of course file locations and stream names may change depending on your computer configuration.
*** Sample Batch file 2: Broadcast a few HD files in a loop ***
NOTE! The file MUST be MPEG2 format. BroadcastHD.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe"
"C:\Control\worktestvideo\Shuttle.trp" loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 "C:\Control\worktestvideo\Clip4.trp" --loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 "C:\Control\worktestvideo\Thunderbirds 480I.mpg" --loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1
*** Sample Batch file 3: Broadcasts whats on your PC screen. ***
Note: First set your screen resolution to 1480x720p Screencast.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe" screen://
:sout=#transcode{vcodec=mp2v,vb=2000,scale=1}:rtp{dst=192.168.1.193,port=5002,mu x=ts} :no-sout-rtp-sap :no-sout-standard-sap :ttl=1 VLC GUI Streamer Configuration. Set to RTP streaming mode. Address:
192.168.1.193 Port:
5002 __ 16
1 | Revised Operator Manual | Users Manual | 1.05 MiB | August 10 2012 |
MT-300 Pico Broadcaster Operator Manual MT300 Pico Broadcaster Version 1.2 OPERATOR MANUAL __ 1 MT-300 Pico Broadcaster Operator Manual Table of Contents 1. 2. PREFACE............................................................................................................................................ 3 IMPORTANT NOTICES ................................................................................................................... 3 FCC PART 15 INFORMATION TO THE USER ................................................................................................. 3 RF EXPOSURE............................................................................................................................................. 3 3. INTRODUCTION............................................................................................................................... 4 OVERVIEW ................................................................................................................................... 4 3.1 DEFAULT SETTINGS ..................................................................................................................... 5 3.2 GENERAL DESCRIPTION ............................................................................................................... 5 3.3 3.4 INTELLECTUAL PROPERTY WARNING........................................................................................... 5 3.5 SYSTEM ARCHITECTURE ................................................................................................................... 6 3.6 APPLICATIONS IN DIGITAL SIGNAGE ................................................................................................. 7 3.7 LIST OF ABBREVIATIONS ................................................................................................................... 7 4. INSTALLATION ................................................................................................................................ 8 4.1 FRONT/REAR PANEL INTERFACE ....................................................................................................... 8 SETTING UP MT300 FOR FIRST TIME USE .......................................................................................... 8 4.2 4.3 USING YOUR PICO BROADCASTER ...................................................................................................13 5. STREAMING .....................................................................................................................................14 5.1 STREAM CONTENT TO DEVICE ..............................................................................................................14 5.2 TUNE THE TV RECEIVER .....................................................................................................................16 6. TROUBLE SHOOTING ...................................................................................................................17 6.1 6.2 6.3 HARDWARE SETUP ..........................................................................................................................17 SET UP AND TEST ETHERNET CONNECTION. ....................................................................................17 TUNING THE TV RECEIVER .............................................................................................................18 Copyright 2012 by MELD Technology Inc. Information furnished in this document is believed to be accurate and reliable, but MELD assumes no responsibility for any errors that many appear in this material. __ 2 MT-300 Pico Broadcaster Operator Manual 1. Preface This document provides operator information on how to set up the MT300 (Ethernet to Broadcast) Pico Broadcaster. This device requires professional installation and the use of tools and procedures for determining location, minimum power requirements. 2. IMPORTANT NOTICES FCC Part 15 Information to the User Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the rules for TV bands devices, pursuant to part 15 of the FCC rules. These rules are designed to provide reasonable protection against harmful interference. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
(1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver.
(3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
(4) Consult the manufacturer, dealer or an experienced radio/TV technician for help. RF Exposure The radio described in this manual transmits RF energy. The concentrated energy from the antenna may pose a health hazard. All antennas used with this radio must be installed to provide a minimum separation from all persons of 40 cm (15.7 inches). The above separation distance must be maintained at all times. More information can be obtained from the FCC at the following website:
http://www.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet65/oet65.pdf
. __ 3 MT-300 Pico Broadcaster Operator Manual 3. Introduction The Meld Technology MT300 White Space radio must be professionally installed by a trained installer. The installation must be in accordance with 47 CFR Part 15 Subpart H and the instructions contained in this manual. Only the following components are approved for use with the radio. Power Supply: Stontronics 3A-401WP12 Antenna:
U Tek Technology Co. EA-79X-1 3.1 Overview MELD develops Pico Broadcast products for wirelessly distributing content to any DTV ever made for the North American market using newly opened white space frequencies and broadcast standard modulation methods. The advantages of Personal Broadcast based solutions are:
Lower cost labor for installation, modification and support Economy of scale using standard DTV receivers and components verses other specialized non-standard receivers and communication methods. MELDs Pico Broadcaster sends live full HD content wirelessly to any number of DTVs located in an unobstructed effective range of 360 feet, about the size of a football field. No cabling or infrastructure equipment investment needed. __ 4 MT-300 Pico Broadcaster Operator Manual 3.2 Default Settings The device has two IP address. 1) System Control CPU (default) IP address: 192.168.1.194 Gateway IP: 192.168.1.254 2) Digital Modulator (default IP address) IP address: 192.168.1.193 Port: 5002 3.3 General Description Figure 1 - Typical Setup for Device configuration and TVWS access The MT300 is an easy to use Fixed TV bands device using a VSB modulator that is designed to provide low-power transmission of a DTV compatible signal over a limited area. It is designed to not interfere with licensed broadcast transmissions and complies with the FCC CFR 47 Part 15 subpart H rules for TV Band devices. It is designed to work with the tuner input of any Digital TV sold in North America. The MT300 is designed to accept properly formatted MPEG2 transport streams from a local PC running VLC or similar streaming software or a media server. The transmitted signal is compliant with the tuner input of a Digital TV receiver. Intellectual Property Warning 3.4 Some of the concepts described in this document are protected by appropriate patent protections or other legal means. These areas are identified in the text as being proprietary. For additional information on these subjects please contact MELD directly. The device described herein is protected by US Patent #8,063,996, other patents pending. __ 5 MT-300 Pico Broadcaster Operator Manual 3.5 System Architecture The device has two IP address:
System Control CPU (default) IP address: 192.168.1.194, Gateway IP: 192.168.1.254 This address points to a web form used for user registration and setting up the radio for FCC compliant operation including database access, and radio control for operational parameters of the system, such as preferred channels and power. Digital Modulator (default IP address) IP: 192.168.1.193 Port: 5002 This IP address is for Transport Stream content going directly to the MELD Digital Modulator for ATSC modulation. __ 6 MT-300 Pico Broadcaster Operator Manual 3.6 Applications in Digital Signage Pico Broadcast HD video distribution would enable airports, hotels, restaurants, bars, schools, hospitals, professional, industrial applications to wirelessly send high-quality video to any number of screens. Proven reliable: Used around the world; day in, day out, digital broadcast TV reliably sends perfect clear HD images and sound over large areas. Completely wireless: No messy wires run, hide or trip over. No external box need: Signal is 100% compatible with any DTV ever built. 3.7 List of abbreviations ATSC is the Government "Standard" for the Digital (RF) Broadcast Signal 8VSB is the name of the modulation standard used in ATSC Systems SMPTE 310M is the electrical interface that carries MPEG-2 transport streams to 8VSB modulators PSIP is the name of the "table" structure that defines the structure and order of the MPEG Streams in a valid broadcast stream ... per government regulations of USA __ 7 MT-300 Pico Broadcaster Operator Manual 4. Installation 4.1 Front/Rear Panel Interface Note: It is recommended the MT300 be installed and located in a secure area such as a network closet or operations center. The device must be installed in a location that provides a minimum separation from all persons and the antenna of 40 cm (15.7 inches). Please refer to the RF Exposure warning on page 3. Setting up MT300 for first time use 4.2 To configure the device for the first time:
Connect a PC to the MT300 Ethernet port and set the computers IP Address to a static IP address on the same subnet as the MT300 (e.g., 192.168.1.100). This can be done as a direct connection or via a router, please reference figure 1 and figure 2. Note: The MT300 needs internet access to be able to operate. The transmitter will not be enabled until the device successfully registers with and receives a channel list from the TV Bands database service. __ 8 MT-300 Pico Broadcaster Operator Manual Figure 2 Alternative setup for device configuration Connect the antenna provided to the RF port located on the backside of the device.
(Use of a different antenna other than the one provided is prohibited) Plug-in the power supply adapter supplied with the MT300.
(Use of a different power supply other than the one provided is prohibited) Set up With your browser to go: http://192.168.1.194/ and complete the device registration form. All fields are required for successful registration. This will enable the FCC certified database to authenticate the system and provide white space channels that are available for use in your location. Reference the examples shown below. Professional installation tools and procedures for determining location must be used to accurately determine the location within +/- 50 m accuracy. __ 9 MT-300 Pico Broadcaster Operator Manual Registration Screen NOTE: PRESS SAVE AND APPLY BEFORE GOING TO NEXT SCREEN. __ 10 MT-300 Pico Broadcaster Operator Manual Status Screen After your device communicates with the database (allow up to 1 minute) the transmitter output will be enabled. NOTE: The transmitter will not output a signal prior to being authenticated by and receiving a channel list from the White Space Registration database. __ 11 MT-300 Pico Broadcaster Operator Manual Advanced Settings Set the power level to the lowest level required by the application The FCC rules for White Space devices require that the minimum transmit power required for reception of the signal must be used. The MT300 transmit power must be adjusted to use the minimum power necessary for reception of the signal. Use the following steps to determine the minimum required transmit power:
Step 1 - Locate the TV receiver furthest from the MT300 location. Step 2 - Set the power level selection to a value of 1 by using the Power Level pull down menu. (A setting of 1 is lowest available power and a setting of 11 is the highest rated power.) Step 3 - Begin transmission as described in section 5 and adjust the power level setting by increments of 1 until a picture of the transmitted content is viewable on the digital TV. Set the preferred channels To select preferred channels from the list of available channels, fill in the Preferred Channels field with the desired channels of operation in order of preference. __ 12 MT-300 Pico Broadcaster Operator Manual Using your Pico Broadcaster 4.3 Station Identification Signal The FCC requires that Fixed TVBDs transmit identifying information sufficient to identify the device and its geographic coordinates. The MT300 ID signal is transmitted as an ATSC compliant signal that can be received by any Digital TV receiver. The following information is required in the ID message:
Transmitter Location: 34.34567 N, 119.32487 W FCC ID: OKVMT300 Manufacturer: MELD Technology Following the steps below the operator is required to stream the identification information for transmission no less than once a day. Step 1: Create a file containing the required identification identified above. Using a video editing system such as Micro Soft Movie Maker or others, create a Title Screen containing 3 lines with the following information:
Transmitter Location: 34.34567 N, 119.32487 W FCC ID: OKVMT300 Manufacturer: MELD Technology The location information above is an example only. The location will be unique for each device installation, refer to section 4.2 of this manual to obtain the registration location information for your device Step 2: Save your file as an MPEG2 standard format file Using the video editor render the Title Screen as a 3 second MPEG2 formatted file. Step 3: Stream the content to the MT300 Following the instructions in section 5.1 of this manual, stream the MPEG2 file to the MT300. Verify the information is displayed on at least one of the TV receivers tuned to the transmitting channel as shown in the example below:
__ 13 MT-300 Pico Broadcaster Operator Manual NOTE: When not streaming content to your MT300, turn off your transmitter by removing power to the device. 5. Streaming 5.1 Stream content to device If you are using a Bright Sign box youll need to refer to their manual. If you are using a PC you can use the VLC media player as an example. The application can be found here: http://www.videolan.org/vlc/index.html. If you are unfamiliar with VLC media player follow the instructions below. We are currently using VLC for streaming (www.videolan.org). This configuration has been tested using version 1.0.5 and 1.1.11. We suggest you download the latest version, its free. For more information go to www.meldtech.com/support Setting up the PC In a DOS window type IPCONFIG to view the PC IP address. Note: When using direct connection, make sure the PC and MT300 are in the same IP domain. Set the computers IP Address to a static address on the same subnet as the MT300 (e.g., 192.168.1.100) in a DOS window type ping 192.168.1.193 If properly working the ping command will return Request timed out as shown in Fig 1.0. This means the Ping command properly saw the MT300 but the MT300 did not respond back, which is to be expected as the MT300 is a one-way streamer and cannot reply. If it says not connected, check physical connection and power MT300. Make sure ARP table registry is correct In a DOS window type type Arp a __ 14 MT-300 Pico Broadcaster Operator Manual You should see the device Internet Address: 192.168.1.193 If using VLC GUI Streamer Configuration Set to RTP streaming mode Address:
Port:
192.168.1.193 5002 Using VLC Streamer Command line Easy streaming If you find the navigating the VLC GUI a little tedious we suggest we set up some batch files. (Some examples are provided below.) You could also use VLC with a command line interface via DOS window for streaming; it is easier than the GUI interface. Creating a batch file is a good way to easily and simply broadcast demo content. Of course file locations and stream names may change depending on your computer configuration. Sample Batch files Streaming an DVD What you are doing: Sending DVD stream to 192.168.1.193, port=5002
*** Sample Batch file 1: Broadcasts a DVD ***
Note: It is very easy and convenient to stream DVDs using VLC. (DVDs are a great source for TS material). We suggest you start with this Using notepad editor to create BroadcastDVD.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe" dvdsimple://D:\
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 Streaming an MPEG2 file What you are doing: Sending an MPEG2 transport stream to 192.168.1.193, port=5002 How to do it: Creating a batch file is a good way to easily and simply broadcast demo content.
*** Sample Batch file 2: Broadcast a few HD files in a loop ***
NOTE! The file MUST be MPEG2 format. __ 15 MT-300 Pico Broadcaster Operator Manual BroadcastHD.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe"
"C:\Control\worktestvideo\Shuttle.trp" loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 "C:\Control\worktestvideo\Clip4.trp" --loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 "C:\Control\worktestvideo\Thunderbirds 480I.mpg" --loop
:sout=#rtp{dst=192.168.1.193,port=5002,mux=ts} :no-sout-rtp-sap :no-sout-standard-sap
:ttl=1 Streaming your PC screen What you are doing: Sending your PC screen to 192.168.1.193, port=5002
*** Sample Batch file 3: Broadcasts whats on your PC screen. ***
Note: First set your screen resolution to 1480x720p Screencast.bat
"C:\Program Files (x86)\VideoLAN\VLC\vlc.exe" screen://
:sout=#transcode{vcodec=mp2v,vb=2000,scale=1}:rtp{dst=192.168.1.193,port=5002,mu x=ts} :no-sout-rtp-sap :no-sout-standard-sap :ttl=1 5.2 Tune the TV Receiver Select antenna in on your TV. Make sure you have an antenna attached. Using the keypad, type in the preferred channel selected during the device setup. Example: 23.1. If the TV does not allow you to directly type in a channel, execute a channel scan and then type your preferred channel. Example 23.1 __ 16 MT-300 Pico Broadcaster Operator Manual 6. Trouble Shooting Hardware Setup 6.1 If the MT300 is not transmitting the supplied content, the device may be unable to contact the database or the media server may not be configured correctly. You must connect the MT300 to an internet accessible network in order to access the internet for database services. The media providing streaming content to the MT300 must be configured correctly and the TV tuner must be tuned to the correct channel to receive the transmitted content. Refer to the following steps:
Set up and test Ethernet connection. 6.2 If the power LED is not illuminated on the MT300 front panel:
Verify the power connection is securely plug in on the back panel Verify the A/C power outlet that power supply is plugged into. Check the static address setting on the PC or media delivering the content. In a DOS window type IPCONFIG to view the PC IP address. Note: When using direct connection, make sure the PC and MT300 are in the same IP domain: Set the computers IP Address to a static address on the same subnet as the MT300 (e.g., 192.168.1.100) If the transmit or On Air light is not illuminated on the front panel, verify the MT300 network connection to the TVWS database service. Connect a PC to the same local network connection that the MT300 is using Verify a successful reply from the TVWS service:
In a DOS window Type ping www.tvws.spectrumbridge.com ping tvws.spectrumbridge.com Pinging tvws.spectrumbridge.com [204.51.99.33] with 32 bytes of data:
Reply from 204.51.99.33: bytes=32 time=27ms TTL=242 __ 17 MT-300 Pico Broadcaster Operator Manual Check Ethernet connection to the MT300 in a DOS window type ping 192.168.1.193 If properly working the ping command will return Request timed out as shown in Fig 1.0. This means the Ping command properly saw the MT300 but the MT300 did not respond back, which is to be expected as the MT300 is a one-way streamer and can not reply. If it says not connected, check physical connection and power MT300. Make sure ARP table registry is correct In a DOS window type type Arp a You should see the device Internet Address: 192.168.1.193 Note: If you do NOT see the device youll need to force the ARP table to map to the IP address to the physical address of the MT300 (i.e. 00 02 03 04 05 06.) ARP command to set ARP TABLE in a DOS window type arp -s 192.168.1.193 00-02-03-04-05-06 Tuning the TV Receiver 6.3 If you are confident that you have correctly set up the media server and the transmit light on the MT300 is illuminated you may need to repeat the channel scan on you TV receiver. Select antenna in on your TV. Make sure you have an antenna attached. Using the keypad, type in the preferred channel selected during the device setup. Example: 23.1. If the TV does not allow you to directly type in a channel, execute a channel scan and then type your preferred channel. Example 23.1 __ 18
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2012-11-28 | 623 ~ 695 | WGF - White Space Device with Geo-location- Fixed | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2012-11-28
|
||||
1 | Applicant's complete, legal business name |
Meld Technology, Inc.
|
||||
1 | FCC Registration Number (FRN) |
0016920720
|
||||
1 | Physical Address |
1642 Canary Drive
|
||||
1 |
Sunnyvale, California 94087
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
n/a | ||||||
app s | FCC ID | |||||
1 | Grantee Code |
OKV
|
||||
1 | Equipment Product Code |
MT300
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
J**** D******
|
||||
1 | Title |
President/CEO
|
||||
1 | Telephone Number |
408-2********
|
||||
1 | Fax Number |
407-8********
|
||||
1 |
j******@meldtech.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Meld Technologies, Inc.
|
||||
1 | Name |
J**** D********
|
||||
1 | Physical Address |
1645 Canary Drive
|
||||
1 |
Sunnyvale, California 94087
|
|||||
1 |
United States
|
|||||
1 | Telephone Number |
408-2********
|
||||
1 | Fax Number |
360-2********
|
||||
1 |
j******@meldtech.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Meld Technologies, Inc.
|
||||
1 | Name |
J****** D******
|
||||
1 | Physical Address |
1645 Canary Drive
|
||||
1 |
Sunnyvale, California 94087
|
|||||
1 |
United States
|
|||||
1 | Telephone Number |
408-2********
|
||||
1 | Fax Number |
360-2********
|
||||
1 |
j******@meldtech.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | WGF - White Space Device with Geo-location- Fixed | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Low Power Fixed TVBD | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power is conducted. The device is approved with the following use conditions: 1. This device must be professionally installed by an installer authorized by the grantee and installed in a permanent manner, such as a locked enclosure or secure fastening, which prevents the device from being readily moved. 2. This device is only authorized to transmit on TV Channels 21-34 (512-596 MHz) and Channels 39-51 (620-698 MHz). 3. This device is approved for operation with the Spectrum Bridge TVWS database. 4. The use of a directional antenna or antenna gain higher than 2 dBi is prohibited. 5. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. A minimum separation distance of 40 cm should be maintained between the device and any human body. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Timco Engineering, Inc.
|
||||
1 | Name |
B**** C****
|
||||
1 | Telephone Number |
352-4********
|
||||
1 | Fax Number |
352 4********
|
||||
1 |
b******@timcoengr.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15H | TP | 515 | 593 | 0.014 | 50 ppm | C1F | ViXS 4208 | ||||||||||||||||||||||||||||||||
1 | 2 | 15H | TP | 623 | 695 | 0.014 | 50 ppm | C1F | ViXS 4208 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC