RTEC R3800-F is a high-performance all-in-one UHF RFID reading and writing
equipment, support ISO18000-6C protocol, working frequency band contains the
national standard: FCC: 902.75MHz ~ 927.25MHz with recognition distance, fast
speed, high accuracy, strong anti-interference ability, excellent protection performance
and easy to install and use characteristics.
1.2 Main functions and technical performance parameters
Device size
156x130x39mm
Output Power
21.5dBm(max)
Package size
285x265x80mm
Receive
<-85dBm
Total mass
of
equipment
500g
Reading Rate
>tags/s
Total mass
1150g
Tag buffer
200tags@96bit EPC
Body material
Aluminum alloy
Tags RSSI
Support
Input voltage
DC 12~24V
Standby current
<10mA
Antenna
connection
protection
protection
Antenna
connection
Support
Support
Max work current
Host Communication
RS-232、TCP/IP
1000mA ±5%@DC 12V
Input
Operating Temp
-20℃~+65℃
GPI0
2 input optical coupling
2 output coupling
Storage Temp.
-40℃~+85℃
Band Rate
115200bps(by default)
Humidity
Cooling method
Air cooling
Air Protocol
Accessories
Serial port
line: one;
5%RH~95%RH(no
condensation)
EPC global UHF Cass 1
Gen 2
SMA Female
seat
of
external thread(16pcs)
RF Interface
Work frequency range
( Other frequency bands
12V/3APower cord: one;
warranty card: one
902~928MHz
can be customized)
2、Schematic diagram
2.1 Structure size
2.2 Interface diagram
Interface name ( left to
Function description
right)
POWER
Power indicator (blue, always on after power on)
DC12~24V
Power input port, input voltage range: 12~24V;
RUN
Card reader indicator (blue, it will flash after
(Default: 12V/3A)
reading the label)
12VOUT
DC12 Output
GND
Ground [can be used as a trigger signal]
IN1
IN2
Trigger input 1
Trigger input 2
OUT1-1
relay1-On
OUT1-2
relay1-COM
OUT2-1
relay2-On
OUT2-2
relay2-COM(cid:13)
COM
Serial port
NET
Network port (supports 10/100M Ethernet
communication)
16 ways SMA external thread female head
2.3 Network application connection diagram
The network interface is used for long-distance high-speed connection (not more than
80 m), and can be connected to a switch or router through a network cable, or directly
to a PC network interface, as shown in the following figure.
3. Installation Instruction
3.1 precautions
In order to ensure the normal and stable work of the equipment and the safety of
your personal and property, please read the following precautions carefully before
installing the RTEC R3800-F reading and writing equipment:
1.First check whether the ground terminal of the power socket is connected to the
ground, and check whether the local power supply voltage meets the applicable
voltage range of the reader;
2.Check that the device is tightly connected to the outside;
3.Pay attention to the type selection and length limitation of the network cable and
serial cable:
meters
The network cable adopts direct connection, the length does not exceed 80
The Serial cable adopts direct connection, the length does not exceed 10 meters
When installing multiple readers, the antenna placement method and antenna spacing
should be appropriate to avoid mutual interference.
Before installing the reader, please carefully check whether the product is in good
condition and whether the accessories are complete. If there is damage or shortage,
3.2 Installation conditions
please contact the supplier in time。
3.3 Device connection
3.3.1 Connect to power adapter
☆ Plug the power cord into the AC power supply socket, and then plug the other
end of the power cord into the power interface of the reader and fasten it.
3.3.2 Connect to PC
☆ The RS232 interface is used for short-distance communication (not greater than
10m), and it can be connected to the PC serial port through the DB9 connector to
realize the communication between the PC and the device;;
☆The RJ45 network port is used for long-distance communication (not greater than
80m), and an extended network cable can be used to connect to the PC。
According to the on-site application, install the reader in the cabinet or box for easy
The acceptance criteria are given mainly from two aspects: structure and
3.4 Install device
maintenance.
3.5 Acceptance
performance.
3.5.1 Structural acceptance
☆ Whether the reader is firmly fixed and not loose;
☆ Whether the cable is firmly connected;
☆ Whether the screw is tightened.
3.5.2 Performance acceptance
☆ whether reader working properly;
☆ Whether the read/write range is reasonable。
4. Operation Instruction
4.1 Demo Software Description
The demonstration software mainly carries out system control, communication
mode selection, parameter setting and query, tag reading and writing and data display
functions for the RTEC R3800-F reader.
Before using the demo software, please check whether the hardware connection
of the reader is complete, focusing on ensuring the following points:
1、The reader is properly connected to the serial port (network or RS232) of the
computer
4.2 Demo software application environment
Software environment
Windows 2000 Service Pack 3、 Windows Server 2003、Windows XP Service
Pack 2、Windows 7
Hardware environment
P4/1.7GHz or above PC, 512M or above RAM, 40G hard drive
4.6 Demo software operation
All functions can be operated only after successful connection. Double click on
the Demo application
4.7. Software
Instructions for use:
Please refer to the documentation for all Demo procedures and processes:
【SingleReaderTest_C#_Software operation instruction_20190822】
The demo software is only used for configuration parameters and debugging
demonstration, not for other commercial purposes.
This software is not the final version and will be updated continuously in the
future. If there is a bug, please give feedback. If it brings you bad experience, we
are sorry.
flashing blue.)
1.Function
Tip: before running the software, please check the following steps。
1、Whether the power supply of the equipment is normal (stable power supply 12V ~ 24V / 3a)
2、Whether the data cable connection is normal (serial port cable and network cable)
3、Whether the antenna connection is normal (feeder and antenna port)
4、Whether the working indicator of the device is normal (the four channel reader is in red when it is powered
on; When the 16 channel reader / writer is powered on, the display is blue, and the card readers are all
This software does not need to install, after decompression can run
2. Interface description
This software provides two connection modes: serial port (RS232) and network port
3.Connection
(RJ45)
serial port (RS232):
The serial port connection only needs to configure the following parameters
1. Select in communication【RS232】
2. click【Connect】,A small box will pop up as shown in the figure below
3. Select the correct serial port number, and then select the baud rate【Baud rate is
115200 by default】(If the parameter has been modified, you need to select the
corresponding parameter, otherwise it cannot be connected)
4. click【Connect】,If the connection is successful, you will be prompted at the bottom
left of the software interface:Connect succeed,The corresponding version number
will be displayed at the bottom right of the interface,The current version number is:
2.0;1.10(The version number will be updated at any time)As shown in the figure
below:
If the display version number is: 1.0.0, the connection fails;
Network port (RJ45)
The network port connection only needs to configure the following parameters
1. Select in communication【NET(UDP)】
2. click【Connect】,A small box will pop up as shown in the figure below
3. 【 Reader IP Add/Port 】 Enter the IP address of the reader, the default is
192.168.0.188, and the port is 4001;
4. 【local IP Add/Port】 Enter local IP address,【Note: to connect to the network
port, you need to change the local IP address to 192.168.0.xxx, the IP address of
the same network segment as the device, XXX is between 1-255, and cannot be
188】
5. click【Connect】,If the connection is successful, you will be prompted at the bottom
left of the software interface:Connect succeed,The corresponding version number
will be displayed at the bottom right of the interface,The current version number is:
2.0;1.10(The version number will be updated at any time)As shown in the figure
below:
Tips:
If the display version number is: 1.0.0, the connection fails;
Connection failure, please check :
1、Are the connections normal
2、Whether the power supply is normal and the voltage is stable (12V ~ 24V / 3A)
3、Does demo open repeatedly;
4、If you have opened demo before and are still occupying the process, you need
to open the process first and close the demo;
If you still can't connect successfully, you can contact the corresponding salesman or
after-sales technology in time
4.Parameter setting
Reader Setup
figure below:
Without reading tag data,click【Setup】,and click【Reader Setup】,As shown in the
click 【GET】 to get the result. There is a corresponding prompt and the current
function configuration of the device will be displayed
【ANT Inventory Time】:Default value:0ms,
(Parameter Description: this time represents the dwell time of each antenna. When the
time arrives, the next antenna will be switched to start inventory. 0 means that the time
limit is not enabled. If it needs to be enabled, it is recommended to set it to at least
50ms and increase it by 10ms)
【Antenna Inventory Times】:Default value:1,
(Parameter Description: this parameter indicates the inventory times of each antenna.
After one inventory, the next inventory will be switched. After all times of inventory,
the next antenna inventory will be switched. By default, it must be at least once.
Usually, it is enough to set only once. This parameter and 【ANT Inventory Time】 are
double values, which will take effect at the same time, At the same time, switch to the
next antenna according to the effective parameters)
【Repeat Times】:Default value:0,
(Parameter Description: all antennas will automatically enter the next cycle after
polling for one cycle. The default value of 0 is invalid, which means infinite cycles)
【Antenna Interval time】:Default value:0ms,
(Parameter Description: after the inventory of each antenna is finished, the next
antenna is switched to start inventory. This parameter indicates whether to wait for
time before switching to the second antenna after the inventory of one antenna is
finished. The default value of 0 means no waiting. If this parameter is enabled, it is
recommended to set it to at least 10ms increment)
【Repeat Interval time】:Default value:0ms,
(Parameter Description: after the end of each cycle, it will enter the next cycle. This
parameter indicates whether to wait for time to enter the next cycle after the end of one
cycle. The default value is 0, which means no need to wait. If this parameter is enabled,
it is recommended to set it to at least 10ms increment)
【Heartbeat Pack】:Default value:Not checked. Check if you need a heartbeat pack
(Parameter Description: the heartbeat packet can prompt whether the connection
status of the device is healthy or not. Generally, it is not enabled and can be checked
selectively,
【SESSION】Default value:S1;
【TARGET】Default value:A;
【TAGFOCUS】Default value:Not checked;As shown in the figure below::
【Antenna Parameter】:Select the antenna number corresponding to the hardware, and
set the power, power range:21.5dBm MAX;
Note: after the parameters are configured, click 【SET】 to take effect
After setting【Reader Setup】,card reading demonstration, click【EPC】, taking the
Reading demonstration
following parameters as an example:
Click [SET], after setting successfully, click [OK]
again, and then close [reader function setting] interface
Then click【EPC】
To stop, click【STOP】
After reading the Tags, as shown in the figure below:
FCC Warning
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the
—Consult the dealer or an experienced radio/TV technician for help.
receiver is connected.
FCC Caution
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
The user manual or instruction manual for an intentional or unintentional radiator
shall caution the user that changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate the
equipment. In cases where the manual is provided only in a form other than paper,
such as on a computer disk or over the Internet, the information required by this
section may be included in the manual in that alternative form, provided the user can
reasonably be expected to have the capability to access information in that form.
RF Exposure Statement
This equipment must be installed and operated in accordance with provide
instructions and the antenna used for this transmitter must be installed to provide a
separation distance of at least 20 cm from all persons and must not be co-located or
operation in conjunction with any other antenna or transmitter. End-users and
installers must be provided with antenna installation instructions and transmitter
operating conditions for satisfying RF exposure compliance.