MEMS EVOLUTION3 SENSOR PRODUCT NOTICE Product name MEMS EVOLUTION3 SENSOR CAI TBA PRODUCT NAME MEMS Sensor PRODUCT DESCRIPTION The MEMS EVOLUTION3 SENSOR is a battery powered air pressure and air temperature sensor designed to operate inside tubeless earthmover tires. This information is sent, via a radio transmitter, to a MEMS EVOLUTION3 TRANSCEIVER unit, which is usually mounted in the cab of the vehicle.
: RV1.30
: FI5-RV1-30F
: 5056A-RV130F FCC / IC CERTIFICATION Model FCC ID IC This device complies with part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following 2 conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Le Prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est authorise aux deux conditions suivantes: (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Warning! Changes or modifications not explicitly approved by Michelin will invalidate the authorization of this device. Operation of an unauthorized device is prohibited under section 302 of the communications act of 1934, as amended, and Subpart1 of Part 2 of chapter 47 of the code of Federal Regulations PRODUCT SPECIFICATION Performance Characteristics Normal transmission period: 60 seconds + 10 seconds Fast transmission period 16 seconds Tire compatibility: 49'' to 63'' earthmover tubeless tires Pressure resolution: 1kPa Typical pressure accuracy:
30kPa, 0.3 bar, 4,35 psi (-20 to + 90C, -4 to + 194F ) Temperature resolution: 1C - 1.8F Typical temperature accuracy:
2 C, 1.8F (- 20 to + 90C, - 4 to + 194F ) RF Performance TX frequency: 433.92MHz ISM band RF output power: <72.9 dBuV/m @ 3m as per FCC 15.231 (e) *
RF data rate 5kHz Antenna: Internal helical
* With duty cycle correction as per FCC part 15.35 Electrical Performance Batteries: 1 x Li-ion Operating Conditions Operating temperature range: -40C to +125C; -40F to + 257F Operating pressure range: 100kPa to 1400kPa Absolute; 1 bar to 14 bar Absolute; 14.51 psi to 203.14 psi Absolute Storage Conditions Storage temperature: -40C to +60C, -40F to + 140F Physical Characteristics Approximate dimensions: L= 78mm. W= 70mm. H=46mm Approximate weight: 110g DISPOSAL The MEMS SENSOR must not be disposed of in landfill. At the end of its life, the MEMS SENSOR must be removed from the tire and deposited in a container dedicated to the recycling of electronic equipment that contains batteries. If users do not have access to the appropriate recycling facility, your local Michelin MEMS representative is able to provide a container dedicated to the purpose of collecting MEMS equipment. CONTACT DETAILS For more information or assistance, please contact your Michelin MEMS representative. MFP MICHELIN 2012 All rights reserved. Exclusive property of Manufacture Franaise des Pneumatiques Michelin. Any reproduction or utilization prohibited without the consent of Michelin