VL3000 Manager Tool User Guide V1.05 Smart Machine Smart Decision Document Title VL3000 Manager Tool User Guide Version Date Status 1.00 2013-07-11 Release Document Control ID General Notes SIMCom offers this information as a service to its customers, to support application and engineering efforts that use the products designed by SIMCom. The information provided is based upon requirements specifically provided to SIMCom by the customers. SIMCom has not undertaken any independent search for additional relevant information, including any information that may be in the customers possession. Furthermore, system validation of this product designed by SIMCom within a larger electronic system remains the responsibility of the customer or the customers system integrator. All specifications supplied herein are subject to change. Copyright This document contains proprietary technical information which is the property of SIMCom Limited., copying of this document and giving it to others and the using or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. All rights reserved in the event of grant of a patent or the registration of a utility model or design. All specification supplied herein are subject to change without notice at any time. Copyright SIMCom Wireless Solutions Co., Ltd, 2012 VL3000 Manager Tool User Guide_V1.05 2 2012.05.08 Smart Machine Smart Decision CONTENTS 1. VL3000 Manager Guide ...........................................................................................................5 1.1 Description..........................................................................................................................5 1.2 Terms and Abbreviations...............................................................................................5 2. Main Setting..............................................................................................................................6 3. The Main Window ....................................................................................................................6 4. An Example to Configure VL3000 ...........................................................................................8 Set the Parameters of Base Setting................................................................................8 4.1 Set the Parameters of Global Configure........................................................................9 4.2 Set the Parameters of Function Key............................................................................11 4.3 Set the Parameters of Geo-Fence ................................................................................12 4.4 Set the Parameters of Motion Sensor Setting..............................................................13 4.5 Set the Parameters of Google Link .............................................................................14 4.6 Set the Parameters of Fixed Report Information.........................................................15 4.7 Set the Parameters of Speed Alarm.............................................................................16 4.8 Set the Parameters of AGPS Setting ...........................................................................17 4.9 4.10 Set the Parameters of Free Fall Detect........................................................................18 4.11 Set the Parameters of Acceptable Incoming White List Number................................19 4.12 Set the Parameters of GPS on Need............................................................................20 4.13 Set the Parameters of Password Change .....................................................................26 4.14 Reading .......................................................................................................................27 4.15 History Logs................................................................................................................28 5. Operation Menu ......................................................................................................................29 Read All.......................................................................................................................29 Download All ..............................................................................................................29 Export Config..............................................................................................................29 Import Config..............................................................................................................30 Unlock PIN .................................................................................................................30 AT Setting ...................................................................................................................30 View Log.....................................................................................................................31 AT Debugging .............................................................................................................31 Exit..............................................................................................................................31 6. Operation Attention.................................................................................................................31 VL3000 Manager Tool User Guide_V1.05 3 2012.05.08 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 Smart Machine Smart Decision Revision history Revision V1.00 Date 2013-07-11 Description of change Initial Author Zhaolei.yang VL3000 Manager Tool User Guide_V1.05 4 2012.05.08 Smart Machine Smart Decision 1. VL3000 Manager Guide 1.1 Description VL3000 manager tool is a PC software which can be used to configure VL3000 through "Data and Charge Cable" interface. It is easy for the backend server developers to configure VL3000 with the manager tool, which has user-friendly interface. The correct command messages sent to VL3000 will be displayed on the management tool. (These messages can also be sent by SMS or GPRS). Follow the steps below to start:
1. 2. Power on VL3000. 3. Connect VL3000 to PC. 4. Run "VL3000 Manager.exe". Install the data cable driver "PL-2303 driver Installer.exe". 1.2 Terms and Abbreviations Table 1: Terms and abbreviations Abbreviation APN GPRS GSM IMEI IP SMS TCP GPS HPA VPA DOP MCC MNC LAC TA Description Access Point Name General Packet Radio Service Global System for Mobile Communications International Mobile Equipment Identity Internet Protocol Short Messaging Service Transmission Control Protocol Global Positioning System Horizontal Position Accuracy Vertical Position Accuracy Dilution of Precision Mobile Country Code Mobile Country Code Location Area Code Timing Advance VL3000 Manager Tool User Guide_V1.05 5 2012.05.08 Smart Machine Smart Decision 2. Simtech HS-USB Modem Setting Select the correct com port from the port list, which is displayed in user PCs "Device Manager"
and input the password, with the default value "VL3000". If the password is incorrect, the parameter that users set will not be downloaded to the terminal. 3. The Main Window Function setting AT Command Operations Status VL3000 Manager Tool User Guide_V1.05 6 2012.05.08 Smart Machine Smart Decision
Function setting The function setting zone is used to set and view the parameters of the function.
AT Command This column shows the command message which will be sent to the terminal. The command message can also be sent to the terminal through SMS or GPRS. Note: The last parameter of AT command (the parameter before $ character) is the sequence number for command. It will be invoked in the ACK message of the command.
Operations
[Read]: Import the setting from the local configuration.
[Download]: Download the settings to the terminal via AT command.
Status Display the status of operation, including the serial port status. VL3000 Manager Tool User Guide_V1.05 7 2012.05.08 Smart Machine Smart Decision 4. An Example to Configure VL3000 The manager tool is developed based on the VL3000 Air Interface Protocol. Refer to VL3000 Air Interface Protocol for detailed references. Following is a general procedure to configure VL3000 with manager tool. 4.1 Set the Parameters of Base Setting Step_1 Step_2 Step_3 Step_4 Step_5 Step_6 Step_7 Step_8 Step_1: Select Base Setting option. Step_2: Select Report Mode. There are six modes to be selected 0 - 6. If the settings are 1, 2, 3, 4, 5, then Main Server input is mandatory. If the setting is 1, 3, 6, then SMS Number input is mandatory. Step_3: Get the APN, APN User Name and APN Password information from your telecom operator. Input them in the corresponding fields. If APN is null, the module will use the last value. Step_4: Input IP Address and Port of main server, backup server input is optional. Step_5: Edit the Heartbeat Interval, Default value is 30 seconds. Step_6: Input SMS Number. It is the number ofmobile device to which SMS will be sent. The SMS contains AT response or event report. VL3000 Manager Tool User Guide_V1.05 8 2012.05.08 Smart Machine Smart Decision Step_7: Set Short TCP Hold Time. It can be set only when Report Mode is set to 1 or 2. Step_8: Download the base setting. The parameters of GTQSS are changed. 4.2 Set the Parameters of Global Configure Step_1 Step_2 Step_3 Step_4 Step_5 Step_1: Select Global Configure option. Step_2: Set a group of parameters:
Set Device Name. Set the device name, the length of string is 3-10 bytes. Null input means it is the current value without change.
Set Satellite Number. Normally, 4 satellites are relatively reasonable value. Default value is 0.
Set GPS Fix Delay Time. After successful fix, the position information is deemed valid only when the consecutive positioning seconds are not smaller than the set value. Default value is 0 second.
Set Battery Report Interval. It is the time interval for periodically reporting battery level. Default value is 5 minutes.
Set Power Down Delay. The terminal will send data to server after user presses power key for more than 3 seconds to power off the terminal. The power delay time is the maximum time to complete data transmission, after which the terminal will be shut down completely. Default value is 6 seconds. VL3000 Manager Tool User Guide_V1.05 9 2012.05.08 Smart Machine Smart Decision
Set Geofence Check Interval. Location interval for geofence evaluation, if any geofences are provisioned. Each geofence is evaluated against the location returned at this interval. 0 means no check.
Set SSM2 battery percentage threshold: Under the premise of setting the Super sleep mode parameter to automobile mode (value 2), if the battery percentage is lower than this value, the terminal will enter super sleep mode unconditionally. Note: It is editable only when Super sleep mode parameter is set to 2. Step_3: Set Button Mask. 0000: Not close TCP/IP connection when GTNMR happens. (default) 0010: Close TCP/IP connection when GTNMR happens. Step_4: Set Event Mask. Totally nine events are listed. If the event is chosen, the corresponding report message can be sent to the backend server when that event happens. Otherwise, it will not send the report message to the backend server.
+RESP:GTBAT Real time battery level report
+RESP:GTINF Device information report. It is reported when the terminal is powered on.
+RESP:GTPWD Device power down report. It is reported when the terminal is powered down.
+RESP:GTBCI Report illegal incoming call if the incoming call number is not in the white list set in Google link function.
+RESP:GTCEP Connect to external power supply report
+RESP:GTDEP Disconnect from external power supply report
+RESP:GTMOV Movement detected by motion sensor report
+RESP:GTNMR Non movement detected by motion sensor report.
+RESP:GTPKS Power Key Short Press Event Report. Step_5: Download global configuration. The parameters of GTCFG are changed. VL3000 Manager Tool User Guide_V1.05 10 2012.05.08 Smart Machine Smart Decision 4.3 Set the Parameters of Function Key Step_1 Step_2 Step_3 Step_4 Step_5 Step_6 Step_7 Step_8 Step_1: Select Function Key option. Step_2: Set Power Key function. Default value is 1. Step_3: Set SOS Key Function. Default value is 0. Step_4: Set Disconnect call function. Default value is 0. Step_5: Set SOS Report Interval. It indicates the interval of GPS information report. Default value is 10 seconds. Step_6: Set SOS Number. It is the number to which voice communication connects. Step_7: Set Power Key Interval. Minimum power key report Step_7: Download function key settings. The parameters of GTFKS are changed. VL3000 Manager Tool User Guide_V1.05 11 2012.05.08 Smart Machine Smart Decision 4.4 Set the Parameters of Geo-Fence Step_1 Step_2 Step_3 Step_4 Step_5 Step_6 Step_1: Select Geo-Fence option. Step_2: Set the parameter Confirming Retries. When a geofence violation is first detected, there shall be this many position retries which attempt to confirm that the position is consistently in violation. The retries shall occur 10 seconds apart. If any of the retries return a position that does not qualify, then the GTGEO report will not be sent. Failure to get some or all of the retry fixes shall not prevent the alarm. 0 means no retry. Step_3: Select Mode. 0: disable the fence 1: report when it enters the Geo-Fence range. 2: report when it leaves the Geo-Fence range. 3: report when it enters or leaves the Geo-Fence range. Step_4: Select Figure. 1: circularity with center and radius 2: circularity with center and one point on the circle 3: triangle 4: quadrangle Note: It can be selected only when Mode is not 0. Step_5: Set the graphic parameter. Step_6: Download Geo fence setting. The parameters of GTGEO are changed. Note: Maximum five fences can be set. After the fences settings are completed, the terminal will calculate and set the entire fence based on input parameters. VL3000 Manager Tool User Guide_V1.05 12 2012.05.08 Smart Machine Smart Decision 4.5 Set the Parameters of Motion Sensor Setting Step_2 Step_1 Step_3 Step_4 Step_5 Step_6 Step_7 Step_8 Step_1: Select Motion Sensor Setting option. Step_2: Set M-threshold parameter.
<M-threshold>: M-threshold is a parameter to decide the threshold of Movement Event Report. The movement is judged when terminal detects that its acceleration exceeds the preset acceleration threshold and movement time exceeds the preset movement cycle. Then it will report these events to GPS module. GPS module will process the request and follow the requirement whether to report the data to the server.
<M-threshold> = Acceleration value (g)/0.063 0 means to use the default value1. Step_3: Set M-delay-time parameter. It is the time that the terminals acceleration maintains. The range is 0-255. The measure unit is 10 milliseconds. 0 means to use the default parameter 2 (*10 millisecond). Step_4: Set Static arbitration time parameter. When terminal enters still from movement, the still status will be judged if the still time exceeds that parameter. 0 means to use the default parameter 120 seconds. Step_5: Set Axis parameter. 2: only enable x axis acceleration 4: only enable y axis acceleration VL3000 Manager Tool User Guide_V1.05 13 2012.05.08 Smart Machine Smart Decision 6: enable both x and y axes acceleration Step_6: Set Motion Sensor Enable parameter. 0: disable motion sensor function. 1: enable motion sensor function. Step_7: Select Super Sleep Mode parameter. 0: disable 1: normal mode 2: automobile mode Step_8: Download motion sensor setting. The parameters of GTMSS are changed. 4.6 Set the Parameters of Google Link Step_1 Step_2 Step_3 Step_1: Select Google Link option. Step_2: Set the number in White Call List. Once incoming call is from white call list, terminal will terminate the call, and send a SMS to that number which contains a web link leads to current location of terminal. User can click the link to get the terminals current location. Step_3: Download Google Link setting. The parameters of GTGMP are changed. VL3000 Manager Tool User Guide_V1.05 14 2012.05.08 Smart Machine Smart Decision 4.7 Set the Parameters of Fixed Report Information Step_2 Step_1 Step_3 Step_4 Step_5 Step_6 Step_1: Select Fixed Report Information option. Step_2: Select Mode. 0: disable Fixed Report Function. 1: enable Fixed Report Function. Step_3: Select Discard no fix. 0 to report last known GPS position if there is no GPS fix;
1 to send nothing if there is no GPS fix. Step_4: Set a group of parameters:
Set Begin Time and End Time. The start time and end time of scheduled fixed report. It is noticed to use UTC time here.
Set Check Interval 1. The time interval to fix GPS when the terminal is in motion state. 0 means no check. Default value is 120 seconds.
Set Send Interval 1. The period to send the position information when the terminal is in motion state. 0 means not to send. Default value is 360 seconds.
Set Check Interval 2. The time interval to fix GPS when the terminal is in motionless state. 0 means no check. Default value is 120 seconds.
Set Send Interval 2. The period to send the position information when the terminal is in motionless state. 0 means not to send. Default value is 360 seconds.
Select Movement Detect Mode. 0: disable (default) VL3000 Manager Tool User Guide_V1.05 15 2012.05.08 Smart Machine Smart Decision 1: enable
Set Movement Speed. The speed threshold of movement detection. 0 means not to detect speed.
Set Movement Distance. The distance threshold of movement detection. 0 means not to detect distance. Step_5: Configure the composition of GPS position information for fixed report.
<Veloctiy>
<Azimuth>
<Altitude>
GSM Information including: GSM LAI and CI, including <MCC>, <MNC>, <LAC>,
<CELLID>,<CSQ RSSI>,<TA>.
<Send Time>
Step_6: Download fixed report information setting. The parameters of GTFRI are changed. 4.8 Set the Parameters of Speed Alarm Step_2 Step_1 Step_3 Step_4 Step_1: Select Speed Alarm option. Step_2: Select the Mode
0: disable speed alarm VL3000 Manager Tool User Guide_V1.05 16 2012.05.08 Smart Machine Smart Decision
1: enable when current speed is in the range.
2: enable when current speed is out of the range. Step_3: Set a group of parameters.
Set Min Speed .The lower limit of the speed range.
Set Max Speed .The upper limit of the speed range.
Set Speed Check Interval. Location interval for speed check purpose. If motion sensor is enabled and no motion is detected then location interval is skipped. 0 means not to check.
Set Speed Send Interval. After the speed alarm is triggered, the GTSPD report is sent every time interval with the latest speed. Speed alarm reports shall not be sent more often than this interval.
Set Confirming Retries. When the speed is first detected in the range for speed alarm, there shall be this many position retries attempt to confirm that the speed is consistently in the alarm range. The retries shall occur 10 seconds apart. If any of the retries returns a speed that does not qualify, then the GTSPD report will not be sent. Failure to get some or all of the retry fixes shall not prevent the alarm. 0 means no retry. Step_4: Download the change of user password. The parameters of GTSPD are changed. 4.9 Set the Parameters of AGPS Setting Step_2 Step_3 Step_1 Step_4 Step_5 Step_6 Step_7 Step_1: Select AGPS Setting option. Step_2: Select the AGPS Used 0: not to use AGPS 1: use AssistNow online AGPS VL3000 Manager Tool User Guide_V1.05 17 2012.05.08 Smart Machine Smart Decision 2: use AssistNow offline AGPS 3: use both AssistNow online and offline AGPS Step_3: Select the Autonomous control Step_4: Set a group of online parameters.
Set Online Address. AssistNow online server Address
Set Online User. AssistNow online server User Name
Set Online Password. AssistNow online server password
Set Online Retry Times. AssistNow online server connect retry times limit
Set Online Update Interval. Update local online data from AssistNow online server time interval. Step_5: Set a group of offline parameters.
Set Offline Address. AssistNow offline server Address
Set Offline Retry Times. AssistNow offline server connect retry times limit
Set Offline Almanac Age. It indicates the period exceeds which the almanac will be invalid. It is recommended to set it to be more than 4 hours. 0 means no update. Step_6: Select the AGPS Event Mask to configure which AGPS event will be reported to the backend server. Step_7: Download the change of AssistNow Online/Offline Server information. The parameters of GTAGP are changed. 4.10 Set the Parameters of Free Fall Detect Step_2 Step_1 Step_3 Step_4 VL3000 Manager Tool User Guide_V1.05 18 2012.05.08 Smart Machine Smart Decision Step_1: Select FreeFall Detect option. Step_2: Select Mode to disable/enable freefall detection. Step_2: Set F-count, the time that the terminals acceleration maintains. Step_3: Download the change of freefall detection. The parameters of GTFFA are changed. 4.11 Set the Parameters of Acceptable Incoming White List Number Step_1 Step_2 Step_3 Step_1: Select Acceptable Incoming White List Number option. Step_2: Set the number in Acceptable White Call List column. The two adjacent phone numbers are separated with a comma. Once there is an incoming call from this call list, the terminal will answer the call automatically. Step_3: Download the setting. The parameters of GTSNUM are changed. VL3000 Manager Tool User Guide_V1.05 19 2012.05.08 Smart Machine Smart Decision Set the Parameters of GPS on Need 4.12 Step_2 Step_1 Step_3 Step_4 Step_1: Select GPS on Need option. Step_2: Select the mode. 0: normal mode 1: always on mode Step_3: Set GPS parameters.
<GPS in view>: minimum numbers of GPS in View that SNR is larger than 0
<GPS SNR>: minimum sum limit of GPS Satellites SNR
<Searching seconds>:
If <mode> equals to 0, AfterGPShaveworkedfor<Searchingseconds>,ifthenumbersofGPSislessthan<GPS inview>,atthesametime,GPSsignalsumvalueislessthan<GPSSNR>,GPSwillbe poweredoffforthisround. Step_4: Download the change of GPS power characteristics. The parameters of GTGON are changed. VL3000 Manager Tool User Guide_V1.05 20 2012.05.08 Smart Machine Smart Decision Set the Parameters of Extend Setting 4.13 Step_2 Step_1 Step_3 Step_4 Step_1: Select Extend Setting option. Step_2: Select the Accuracy Parameter. 0: use accuracy parameter Dop for each GTFRI report 1: use accuracy parameter Satellite number used for each GTFRI report Step_3: Extend Setting.
<Power Button Press Time>: configure how many seconds the power button needs to be depressed prior to powering off the unit.
<SOS Button Press Time>: configure how many seconds the SOS button needs to be depressed prior to triggering the SOS.
<Max SOS Reports>: specify the maximum number of SOS reports (+RESP:GTSOS) are sent from the device to the server after the SOS event has been triggered. If the parameter is set to 0, it will keep SOS reports in accordance with the parameter <SOS key> of command.
<Lights Lit Time>: configure how long all of the device lights remain lit after an SOS event is triggered. If the parameter is set to 0, the device lights will stay on.
<Talking Time>: configure the maximum length of time that a single call to or from the device can last. If the parameter is set to 0, talking time will be unlimited. Step_4: Download the Extend Setting. The parameters of GTAEX are changed. VL3000 Manager Tool User Guide_V1.05 21 2012.05.08 Smart Machine Smart Decision 4.14 Set the Renamed Device with the Last 10 Digits of SIM Card(ICCID) Step_2 Step_1 Step_3 Step_1: Select RenamedDevicewiththeLast10DigitsofSIMCard(ICCID) option. Step_2: Select the mode. 0: Restore the device name to original default value DevName. 1: Renamed device with the last 10 digits of the SIM card (ICCID) if SIM card is then in existence. Step_3: Download the setting. The parameters of DevName are changed. VL3000 Manager Tool User Guide_V1.05 22 2012.05.08 Smart Machine Smart Decision Set the Parameters of Protocol Watchdog 4.15 Step_2 Step_3 Step_1 Step_4 Step_5 Step_1: Select Protocol Watchdog option. Step_2: Select the mode. 0: Disable this function. 1: Reboot periodically according to the <Interval> and <Time> setting. Step_3: Set Interval: The interval to reboot the device in day. Set Time: At what time to perform the reboot operation when <Interval> is set. Step_4: Select Report Before Reboot. 0: no report. 1: to report. Whether to report the +RESP:GTDOG message before reboot.0 means no report, 1 to report. Step_5: Download the setting. The parameters of GTDOG are changed. VL3000 Manager Tool User Guide_V1.05 23 2012.05.08 Smart Machine Smart Decision Set the Parameters of Time Adjustment 4.16 Step_2 Step_3 Step_1 Step_4 Step_5 Step_1: Select Time Adjustment option. Step_2: Select the Sign.
+: positive of the local time offset to UTC.
positive of the local time offset to UTC. Step_2: Select the Daylight Saving. 0: disable daylight saving time. 1:
enable daylight saving time. Step_4: Set Hour Offset: UTC offset in hour. Set UTC Time: The configuration UTC time. Step_5: Download the setting. The parameters of GTTMA are changed. VL3000 Manager Tool User Guide_V1.05 24 2012.05.08 Smart Machine Smart Decision Set the Reset 4.17 Step_2 Step_3 Step_1 Step_1: Select Reset option. Step_2: AT Command Step_3: Download the setting. Reset all the protocol command parameter to factory setting, the terminal will restart itself after resetting VL3000 Manager Tool User Guide_V1.05 25 2012.05.08 Smart Machine Smart Decision Set the Parameters of Password Change 4.18 Step_2 Step_3 Step_1 Step_1: Select Password Change option. Step_2: Change the user password
Enter current password in User Password.
Enter new user password in New User Password. Step_3: Download the change of user password. The parameters of GTCFG are changed. VL3000 Manager Tool User Guide_V1.05 26 2012.05.08 Smart Machine Smart Decision Reading 4.19 Step_2 Step_1 Step_3 Step_4 Step_1: Select Reading option. Step_2: Click Read Events Information, the information will show below. Step_3: Click Read GPS Information, the information will show below. Step_4: Click Read Firmware Version, the information will show below. VL3000 Manager Tool User Guide_V1.05 27 2012.05.08 Smart Machine Smart Decision 4.20 History Logs Step_2 Step_1 Step_1: Select History Logs option. Step_2: The history logs will be shown. VL3000 Manager Tool User Guide_V1.05 28 2012.05.08 Smart Machine Smart Decision 5. Operation Menu The operation menu supports Read All, Download All, Export Config, Import Config, Unlock PIN, AT Setting, View Log, AT Debugging, and Exit functions. 5.1 Read All Read all parameters of VL3000 and list them in the corresponding fields. 5.2 Download All Download all settings to VL3000. 5.3 Export Config Export Config exports the current configuration to a new *.ini file. VL3000 Manager Tool User Guide_V1.05 29 2012.05.08 Smart Machine Smart Decision 5.4 Import Config Import Config imports a configuration file. 5.5 Unlock PIN Unlock PIN unlocks the PIN of SIM card. 5.6 AT Setting Set the password of AT command. VL3000 Manager Tool User Guide_V1.05 30 2012.05.08 Smart Machine Smart Decision 5.7 View Log The document of AT log will pop up. 5.8 AT Debugging User can test AT command through this window. 5.9 Exit Exit the PC Tools. 6. Operation Attention When accomplishing the operation with VL3000 by PC manager tools, exit the tools first then plug out the cable from VL3000. Otherwise the power saving algorithm cannot work. VL3000 Manager Tool User Guide_V1.05 31 2012.05.08 Smart Machine Smart Decision Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received,including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant toPart 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. VL3000 Manager Tool User Guide_V1.05 32 2012.05.08 Smart Machine Smart Decision Contact us:
Shanghai SIMCom Wireless Solutions Ltd. Address: Building A, SIM Technology Building, No. 633 Jinzhong Road, Shanghai, P. R. China 200335 Tel: +86 21 3252 3300 Fax: +86 21 3252 3020 URL: www.sim.com/wm VL3000 Manager Tool User Guide_V1.05 33 2012.05.08